CUI CDM

date
11/15/2011
page
1 of 4
MODEL: CDM-15008 │ DESCRIPTION: SPEAKER
FEATURES
•metal frame
•mylar cone
•spring contacts
RoHS
SPECIFICATIONS
parameter
conditions/description
min
diameter
typ
depth
max. power: IEC-60268-5, filter 60 s on / 120 s
off, 10 cycles at room temp
impedance
at 1.2 kHz, 1 V
resonant frequency
at 1 V
sound pressure level
0.25 W, 10 cm ave. at 1, 1.2, 1.5, 2.0 kHz
1 W, 1 m ave. at 1, 1.2, 1.5, 2.0 kHz
at 1.2 kHz, 0.25 W
buzz, rattle, etc.
must be normal at sine wave 1.41 V
operating temperature
0.5
W
6.8
8
9.2
Ω
720
900
1,080
Hz
84
71
87
74
90
77
dB
dB
20,000
Hz
10
%
55
°C
-20
weight
1.2
material
metal
RoHS
yes
MECHANICAL DRAWING
3.5 0.138
3.2 0.126
0.95 0.037
0.2
3.6 0.142
DATE STAMP
01(MONTH)
11(YEAR)
+
11.15 0.439
15.0 0.591
0.2
MAX 3.0
NON-WOVEN
FABRIC
4.3 0.169
0.2
(working height)
5.1 0.201
0.3
(free height)
1.0 0.039
3.0 0.118
4.5 0.177
PAD LAYOUT
cui.com
mm
0.25
response
distortion
units
mm
5.1
input power
units: mm
tolerance: ± 0.5mm
max
15
BLACK
POLYESTER
g
CUI Inc │ MODEL: CDM-15008 │ DESCRIPTION: SPEAKER
date 11/15/2011 │ page 2 of 4
FREQUENCY RESPONSE CURVE
cui.com
CUI Inc │ MODEL: CDM-15008 │ DESCRIPTION: SPEAKER
date 11/15/2011 │ page 3 of 4
PACKAGING
cui.com
CUI Inc │ MODEL: CDM-15008 │ DESCRIPTION: SPEAKER
date 11/15/2011 │ page 4 of 4
REVISION HISTORY
rev.
1.0
description
date
initial release
11/15/2011
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.