AZ DISPLAYS SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY CUSTOMER APPROVAL ※ PART NO. : ATM0280B44B(AZ DISPLAYS) SPECV1.0 APPROVAL COMPANY CHOP CUSTOMER COMMENTS AZ DISPLAYS ENGINEERING APPROVAL DESIGNED BY Herbert CHECKED BY APPROVED BY ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 REVISION RECORD REVISION REVISION DATE VER1.0 AZ DISPLAYS 2015-11-25 PAGE CONTENTS FIRST ISSUE 1 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 ※ CONTENTS 1. GENERAL SPECIFICATIONS 2. PIN ASSIGNMENT 3. OPERATING SPECIFICATIONS 4. OPTICAL SPECIFICATIONS 5. RELIABILITY TEST 6. PRECAUTION FOR USING LCM 7. MECHANICAL DRAWING 8. PACKAGE DRAWING 9. INSPECTION SPECIFICATION AZ DISPLAYS 2 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 1. GENERAL SPECIFICATIONS Item Specification 1. LCD size 2.8 inch(Diagonal) 2. Driver element a-Si TFT active matrix 3. Resolution 240x(RGB)x320 4. Display mode Normally white,Transmissive 5. Dot Pitch (W*H) 0.18mm(W) x 0.18mm(H) 6. Active Area(W*H) 43.2mm(W) x 57.6mm(H) 7. Module size (W*H) 50.0mm(W) x 69.2mm(H) x 2.7mm(D) 8. Surface treatment Anit-Glare 9. Color arrangement RGB-stripe 10. Driver IC Remark Note 1 ILI9341 11. MPU interface 8/16-bit Parallel 8080 interface 12. Backlight power consumption 0.248W(Typ.) 13. Panel power consumption TBD 14. Weight TBD 15. RoHS RoHS compliant Note 1: Please refer to mechanical drawing. AZ DISPLAYS 3 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 2. PIN ASSIGNMENT Pin No. Symbol Function 1~4 5 6 7 8 9 10 DB1~DB4 GND VCC CS RS WR RD 11 IM0 12 13 14 15 16 17 18 19 20 21 22 23~30 31 NC NC NC NC LED_A LED_K1 LED_K2 LED_K3 LED_K4 NC DB5 DB10~DB17 RESET No connection Data bus Data bus Reset signal 32~33 34 35~37 VCC GND DB6~DB8 Power supply Ground Data bus Data bus Ground Power supply Chip select Register select signal Writer operation signal Read operation signal Model selection: 0: 16bit DB(15:0) 1: 8bit DB(15:8) Level Note I/O P P I I I I --- No connection ---- Power supply for backlight P P The backlight ground P P P -I/O I/O I P P I/O I: input, O: output, P: Power AZ DISPLAYS 4 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 3. Operating Specification 3.1 ABSOLUTE MAXIMUM RATINGS Item Symbol Values Unit Remark Min. Max. VCI/IOVCC -0.3 4.6 V Operation Temperature TOP -20 70 ºC Storage Temperature TST -30 80 ºC LED Reverse Voltage VR - 1.2 V Each LED Note 2 LED Forward Current IF 25 mA Each LED Power Voltage Note 1: The absolute maximum rating values of this product are not allowed to be exceeded at any times. Should a module be used with any of the absolute maximum ratings exceeded, the characteristics of the module may not be recovered, or in an extreme case, the module may be permanently destroyed. Note 2: VR Conditions: Zener Diode 20mA 3.2 Typical Operation Conditions Item Symbol Values Unit Min. Typ. Max. VCC 2.5 2.8 3.3 V Input Logic High Voltage VIH 0.7IOVCC -- IOVCC V Input Logic Low Voltage VIL Vss -- 0.3IOVCC V Operating voltage AZ DISPLAYS Remark 5 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 3.3 Backlight driving conditions Item Symbol Voltage for LED Backlight Values Unit Remark 3.4 V Note 1 60 -- mA -- -- Hr Min. Typ. Max. VL 3.0 3.1 Current for LED Backlight IL -- LED life time -- 30000 Note 2 Note 1: The LED Supply Voltage is defined by the number of LED at Ta=25℃ and IL =60mA. Note 2: The “LED life time” is defined as the module brightness decrease to 50% original brightness at Ta=25℃ and IL =60mA. AZ DISPLAYS 6 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 3.4 Timing Characteristics Please refer to IC specification for detailed information. AZ DISPLAYS 7 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 4.0 OPTICAL SPECIFICATIONS Item Viewing Angle (CR≥10) Symbol Condition θL Φ=180o(9 O'CLOCK) θR Values Min. Typ. Max. -- 45 -- o -- 45 -- o Φ=0 (3 O'CLOCK) θT Φ=90 (12 O'CLOCK) -- 50 -- θB Φ=270o(6 O'CLOCK) -- 20 -- Unit Remark degree Note 1 Response Time TON + TOFF -- 16 -- msec Note 3 Contrast Ratio CR -- 480 -- -- Note 4 -- 0.307 -- -- Note 2 -- 0.329 -- -- WX Color Chromaticity Luminance Luminance Uniformity Normal Θ=Φ=0o WY L 180 240 -- cd/m YU 75 80 -- % Note 5 Note 6 2 Note 6 Note 7 Test Conditions: 1. VCI=3.1V, IL=60mA (Backlight current), the ambient temperature is 25℃. 2. The test systems refer to Note 2. Note 1: Definition of viewing angle range Figure 4.1 Definition of viewing angle. AZ DISPLAYS 8 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 Note 2: Definition of optical measurement system. The optical characteristics should be measured in dark room. After 30 minutes operation, the optical properties are measured at the center point of the LCD screen. (Response time is measured by Photo detector TOPCON Figure 4.2 Optical measurement system setup Note 3: Definition of Response time The response time is defined as the LCD optical switching time interval between “White” state and “Black” state. Rise time (TON) is the time between photo detector output intensity changed from 90% to 10%. And fall time (TOFF) is the time between photo detector output intensity changed from 10% to 90%. Figure 4.3 Definition of response. AZ DISPLAYS 9 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 Note 4: Definition of contrast ratio Note 5: Definition of color chromaticity (CIE1931) Color coordinates measured at center point of LCD. Note 6: All input terminals LCD panel must be ground while measuring the center area of the panel. The LED driving condition is IL=80mA . Note 7: Definition of Luminance Uniformity Active area is divided into 9 measuring areas (Refer to Fig. 4-4 ).Every measuring point is placed at the center of each measuring area. Figure 4.3 Definition of measuring points. Bmax: The measured maximum luminance of all measurement position. Bmin: The measured minimum luminance of all measurement position. AZ DISPLAYS 10 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 5. RELIABILITY TEST NO.. 1 2 3 4 5 6 Test Item Description High temperature storage Endurance test applying the high storage temperature for a long time Low temperature Endurance test applying the storage low storage temperature for a long time High temperature Endurance test applying the operation electric stress under high temperature for a long time Low temperature Endurance test applying the operation electric stress under low temperature for a long time High temperature Endurance test applying the /humidity storage high temperature and high humidity storage for a long time High temperature Endurance test applying /humidity operation electric stress under high temperature and high humidity for a long time 7 Temperature Cycle 8 Vibration test 9 Fall test 10 Static electricity test Endurance test applying the low and high temperature cycle -20℃ → 25℃ → 70℃ →25℃ 30min 5min 30min 5min one cycle Endurance test applying the vibration during transportation and using Endurance test dropping the LCM from a high place Endurance test applying static electric stress to terminal Test Condition Remark 80℃,240 H Note 1 Note 4 -30℃,240H Note 1 Note 4 70℃,96H Note 2 Note 4 -20℃,96H Note 1 Note 4 50℃,90% R.H 240H Note 4 40℃ 90% R.H 96H Note 4 -20℃/70℃ 10 cycles 10Hz~50Hz Swing:0.75mm time:30min 600mm height Contact discharge: ±2KV~4KV Air discharge: ±2KV~10KV Note 1: Ta is the ambient temperature of samples. Note 2: Ts is the temperature of panel’s surface. Note 3: In the standard condition, there shall be no practical problem that may affect the display function. After the reliability test, the product only guarantees operation, but don’t guarantee all of the cosmetic specification. Note 4: Before cosmetic and function test, the product must have enough recovery time, at least 2 hours at room temperature. AZ DISPLAYS 11 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 6. PRECAUTION FOR USING LCM 1. When design the product with this LCD Module, make sure the viewing angle matches to its purpose of usage. 2. As LCD panel is made of glass substrate, Dropping the LCD module or banging it against hard objects may cause cracking or fragmentation. Especially at corners and edges. 3. Although the polarizer of this LCD Module has the anti-glare coating, always be careful not to scratch its surface. Use of a plastic cover is recommended to protect the surface of polarizer. 4. If the LCD module is stored at below specified temperature, the LC material may freeze and be deteriorated. If it is stored at above specified temperature, the molecular orientation of the LC material may change to Liquid state and it may not revert to its original state. Excessive temperature and humidity could cause polarizer peel off or bubble. Therefore, the LCD module should always be stored within specified temperature range. 5. Saliva or water droplets must be wiped off immediately as those may leave stains or cause color changes if remained for a long time. Water vapor will cause corrosion of ITO electrodes. 6. If the surface of LCD panel needs to be cleaned, wipe it swiftly with cotton or other soft cloth. If it is not still clean enough, blow a breath on the surface and wipe again. 7. The module should be driven according to the specified ratings to avoid malfunction and permanent damage. Applying DC voltage cause a rapid deterioration of LC material. Make sure to apply alternating waveform by continuous application of the M signal. Especially the power ON/OFF sequence should be kept to avoid latch-up of driver LSIs and DC charge up to LCD panel. 8. Mechanical Considerations a) LCM are assembled and adjusted with a high degree of precision. Avoid excessive shocks and do not make any alterations or modifications. The following should be noted. b) Do not tamper in any way with the tabs on the metal frame. c) Do not modify the PCB by drilling extra holes, changing its outline, moving its components or modifying its pattern. d) Do not touch the elastomer connector; especially insert a backlight panel (for example, EL). e) When mounting a LCM makes sure that the PCB is not under any stress such as bending or twisting. Elastomer contacts are very delicate and missing pixels could result from slight dislocation of any of the elements. f) Avoid pressing on the metal bezel, otherwise the elastomer connector could be deformed and lose contact, resulting in missing pixels. 9. Static Electricity a) Operator Wear the electrostatics shielded clothes because human body may be statically charged if not ware shielded clothes. Never touch any of the conductive parts such as the LSI pads; the copper leads on the PCB and the interface terminals with any parts of the human body. b) Equipment There is a possibility that the static electricity is charged to the equipment, which has a function of peeling or friction action (ex: conveyer, soldering iron, working table). Earth the equipment through proper resistance (electrostatic earth: 1x108 ohm). Only properly grounded soldering irons should be used. If an electric screwdriver is used, it should be well grounded and shielded from commutator sparks. The normal static prevention measures should be observed for work clothes and working benches; for the latter conductive (rubber) mat is recommended. c) Floor Floor is the important part to drain static electricity, which is generated by operators or equipment. There is a possibility that charged static electricity is not properly drained in case of insulating floor. Set the electrostatic earth (electrostatic earth: 1x108 ohm). d) Humidity Proper humidity helps in reducing the chance of generating electrostatic charges. Humidity should be kept over 50%RH. e) Transportation/storage The storage materials also need to be anti-static treated because there is a possibility that the human body or storage materials such as containers may be statically charged by friction or peeling. The modules should be kept in antistatic bags or other containers resistant to static for storage. f) Soldering Solder only to the I/O terminals. Use only soldering irons with proper grounding and no leakage. Soldering temperature : 280°C ± 10°C Soldering time: 3 to 4 sec. Use eutectic solder with resin flux fill. If flux is used, the LCD surface should be covered to avoid flux spatters. Flux residue should be removed afterwards. g) Others AZ DISPLAYS 12 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 The laminator (protective film) is attached on the surface of LCD panel to prevent it from scratches or stains. It should be peeled off slowly using static eliminator. Static eliminator should also be installed to the workbench to prevent LCD module from static charge. 10. Operation a) Driving voltage should be kept within specified range; excess voltage shortens display life. b) Response time increases with decrease in temperature. c) Display may turn black or dark blue at temperatures above its operational range; this is (however not pressing on the viewing area) may cause the segments to appear “fractured”. d) Mechanical disturbance during operation (such as pressing on the viewing area) may cause the segments to appear “fractured”. 11. If any fluid leaks out of a damaged glass cell, wash off any human part that comes into contact with soap and water. The toxicity is extremely low but caution should be exercised at all the time. 12. Disassembling the LCD module can cause permanent damage and it should be strictly avoided. 13. LCD retains the display pattern when it is applied for long time (Image retention). To prevent image retention, do not apply the fixed pattern for a long time. Image retention is not a deterioration of LCD. It will be removed after display pattern is changed. 14. Do not use any materials, which emit gas from epoxy resin (hardener for amine) and silicone adhesive agent (dealcohol or deoxym) to prevent discoloration of polarizer due to gas. 15. Avoid the exposure of the module to the direct sunlight or strong ultraviolet light for a long time. The brightness of LCD module may be affected by the routing of CCFL cables due to leakage to the chassis through coupling effect. The inverter circuit needs to be designed taking the level of leakage current into consideration. Thorough evaluation is needed for LCD module and inverter built into its host equipment to ensure specified brightness. AZ DISPLAYS 13 (3.00) (2.00) (1.40) (31.80) 57.60(A.A) 60.00(UP POL.) 64.95±0.1 69.20±0.15 Conductor 3.5±0.3 (2.0) 0.3±0.05 Stiffener 5 .9 ?0 4- (4.5) 37 Component area 55 Max0.5 IF=60mA,U=3.1V(typ.) K1 K2 K3 K4 Kapton tape 68.25 W:0.35±0.05 P0.5*36=18.0±0.1 19.0±0.1 (41.0) 0.35 4?0. 49.05±0.1 (26.61) 0.5±0.1 (15.5) 1 Remove Tape 2.70 4-0.80 3.00±0.1 0.48±0.15 K1 K3 A K2 K4 240(RGB)X320 DOTS see detail A 50.00±0.15 46.40±0.1 45.00(UP POL.) 43.20(A.A) (25.00) Front AZ DISPLAYS Rear (1.80) (2.50) (3.40) A 1 K4 K2 A K3 K1 Diagram of bending FPC not attached to backlight T=0.8MAX Include tape&tin 37 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 7. MECHANICAL DRAWING 5.0±0.5 (13.6) 28.5±0.5 14 ATM0280B44B (AZ DISPLAYS) TFT MODULE V1.0 8. PACKAGE DRAWING T.B.D. 9. INSPECTION SPECIFICATION T.B.D. AZ DISPLAYS 15