RoHS EP5 Power Transformer AEP5-3932I Operating temperature range: -40ºC to +85ºC Reflow Condition: Maximum reflow temperature is 250ºC/-5ºC time is 20~40 sec. (Refer to IPC/JEDECJ-STD-020 standard Meets the specifications for supplementary insulation per UL60950-1, CSA60950-1, EN60950-1, IEC60950-1 with working voltage of 250V. Turns Ratio (1-4) / (8-5), (tie 2+3,6+7) Inductance Ls @100KHz,0.1V (1-4), (2+3 short) Leakage Inductance Ls @100KHz,0.1V (1-4), (2+3,5+6+7+8) 1.4:1 (±1%) 430uH (±10%) 1.0uH Max Surge Test 10/700 between primary windings Surge Test 2/10 between primary and secondary windings 1.5KV 2.5KV DCR (1 – 4) (tie 2+3) DCR (8 – 5) (tie 6+7) 47dB Min 44dB Min 30dB Min 1.0Ω Max 1.0Ω Max Longitudinal Balance 1-4:8-5(tie 2+3,6+7) 12MHz 17MHz 30MHz Interwinding THD Capacitance @30KHz, 3 Vrms/100:51Ω Cs @100 KHz, 0.1V 1-4:8-5 (tie 2+3,6+7) (1-8), (tie 2+3. 6+7) -60dB Max 50pF Max. HI-POT (1-8), (tie 2+3, 6+7) 1874VAC/1sec/0.5mA All specifications subject to change without notice. MECHANICAL Unit mm inch A 10.2 max. 0.401 max. B 5.5 REF 0.216 REF C 8.0 max. 0.314 max. D 7.9 max. 0.311 max. E 1.9 0.074 F SQ 0.4 SQ 0.015 PAD A 4.5 0.177 PAD B 8.6 0.338 PAD C 0.9 0.0.5 PAD D 1.9 0.074 Unless otherwise specified, all tolerances are 0.25 mm ± 0.01 inch SCHEMATICS Line 949-356-1780 Chip ALLIED COMPONENTS INTERNATIONAL REVISED 15 03/28/14 www.alliedcomponents.com