*T3 INTERFACE TRANSFORMER Turns Ratio ( + 2% ) 1:2CT PARAMETER MIN. Inductance 19 MAX. UNITS µHy Rise Time 3.00 nS Leakage Inductance 0.6 µHy Capacitance (CW/W) 10 pF Primary DC Resistance 0.3 ohms 1 Isolation 3000 VRMS Flammability: Materials used in the production of these units meet requirements of UL94-VO and IEC 695-2-2 needle flame test. Parts shipped in anti-static tubes. 50 pieces per tube A Surface Mount Version of this product is Available 3 dB Bandwidth is .200 - 340 (MHz) typical, tested in a 75 ohm system 1 Reinforced insulation * Also suitable for DS3, E3 and STS-1 interfaces Operating Temperature Range: -400C to +850C Dimensions in inches (mm): UNUSED PINS NOT PROVIDED SCHEMATIC DIAGRAM: RHOMBUS INDUSTRIES INC. FSCM NO. 16714 RHOMBUS P/N: T-13109 CUST P/N: NAME: DATE: 12/3/99 SHEET: Rhombus Industries Inc. Transformers & Magnetic Products 1 OF 1 15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 FAX: (714) 896-0971 www.rhombus-ind.com