RHOMBUS-IND T

*T3 INTERFACE TRANSFORMER
Turns Ratio ( + 2% )
1 : 1CT
PARAMETER
MIN.
Inductance
160
TYP.
MAX.
µHy
Leakage Inductance
1.2
µHy
Capacitance (CW/W)
5.0
pF
Primary DC Resistance
1
Isolation
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
UNITS
0.6
3000
Parts shipped in anti-static
tubes. 44 pieces per tube
ohms
VRMS
Tape & Reel
Available
Reinforced insulation
* Also suitable for DS3, E3 and STS-1 interfaces
Dimensions in inches (mm)
.260
(6.60)
MAX.
SCHEMATIC DIAGRAM
6
3
4
1
2
.410
(10.41)
MAX.
.410
(10.41)
MAX.
.020
(0.51)
TYP.
5
.300
(7.62)
MAX.
.010
(0.25)
TYP.
.100
(2.54)
TYP.
.040
(1.02)
TYP.
.510 (12.95)
.480 (12.19)
RHOMBUS P/N: T-13111
CUST P/N:
NAME:
DATE: 6/04/99
SHEET:
Rhombus
Industries Inc.
Transformers & Magnetic Products
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com