IB

I/SPE/IBxxx2/A/02/03/2010
page 1 /1 GB
IBxxxx2
DETECTEUR DE POSITION ANGULAIRE SANS MERCURE
TIP OVER SWITCH- NO MERCURY CONTACTS
"Opened" (1)
10°
DIMENSIONS : mm (inches)
Differential
Angle 15° Max
10°
Ø 5,940
(0,234)
22,1
(0,870)
"Closed" (1)
Remarks: These switches operate when
tilted from the horizontal position. The
switch movement required to cause
contact change (ex OFF to ON) is called
the differential angle.
It is very important when the designing
a tilt switch to allow for the differential
angle and understand that when in the
horizontal position the switch contact
may be open or closed.
2,9 (0,115)
10,2
(0,400)
2x0,50
(0,020)
Ø 4,7
(0,185)
HORIZONTAL
CARACTERISTIQUES PHYSIQUES et ELECTRIQUES / ELECTRICAL & PHYSICAL DATA
CONTACT FORM (TYPE)
SWITCHING VOLTAGE
SWITCHING CURRENT
SWITCHING CAPACITY
OPERATING ANGLE / HORIZONTAL (Opened/Closed)
DIFFERENTIAL ANGLE
CONTACT RESISTANCE
OPERATING TEMPERATURE
STORAGE TEMPERATURE
CASE MATERIAL
CABLE / TERMINATION
(1) Dependent of mounting
60
250
3
± 10°
15
30
-35° / +100°C
-40° / +100°C
Tin plated
Pin
Max. Vac
Max. mA
Max. VA
Max. Deg°
Max. Deg°
Max. Ω
Deg° C
Deg° C
Remarks: When cutting or bending switch leads it is important that the glass seal is not damaged.
The cutting or bending point should be no closer than 3mm to the glass seal and the lead should be
supported between the cutting or bending point an glass to metal seal.
Proud to serve you

celduc
r
e
l
a
i
www.celduc.com
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19