Voltage protection for
DC Solid State Relays
When using DC Solid State Relays special precautions have to be taken, especially
the use of protective components against overvoltage :
-to protect the SSR against the voltage transients coming from the mains,
-to protect the SSR against voltage transients due to the inductive
effect of lines and loads.
Voltage protection can partially be incorporated into the SSR and additional
required protective components are mentionned in red in our technical datasheets : C1, D1 & D2.
C1 : Non polarized capacitor (ex : polypropylen) connected between positive
(+) and negative (-) of the power source. Its function is to compensate the line
inductance between the power source and the relay. Capacitors need time to
discharge so usually the capacitor is equipped with a discharging resistor.
D1 : Transient-voltage-suppression diode, VDR, ... Clamping function to limit
voltage transients across the power element of the DC solid state relay. This is
necessary for DC SSR not equipped built-in voltage clamp.
D2 : Diode ; diode + resistance ; diode + Transient-voltage-suppression diode.
Its function is to eliminate flyback, which is the sudden voltage spike seen accross
the inductive load (or load side line inductance) when its supply voltage is
suddenly reduced or removed.
Please do not hesitate to consult us to have our expertise and select the
right protective components C1, D1 & D2.
Here are the main technical information we need to have :
-Type of DC mains generator and nominal voltage,
-Type of load and load current transient & nominal,
-Requested switching frequency,
-Ambient temperature,
-Wire length between the power source / mains generator,
-Wire length between the SSR and the load.
In order to ease the implementation of these protective components,
celduc relais has developed "ready to use" solutions available in plastic
enclosure :
celduc relais offers 2 different modules :
-ESO01000 - protection against line inductance (C1, D2) - option for SOM (up to
130Vdc nominal)
-ESO02000 - protection against line inductance (C1, D2, D1) - option for SCM (up
to 40Vdc nominal)
http://www.celduc-relais.com/all/news/October/newsukv1015.html
01/03/2016
celduc relais Newsletter - October 2015
Page 2 sur 4
Mounting example SCM + ESO02000 + protection cover 1K470000, everything
mounted on heatsink WF121000.
XKLD0020 : DC solution having all protections included
This DC SSR is designed for inductive loads with high
switching frequency (as for example : valves control,
electro-magnets, ...).
XKLD0020 :
-Diagnostic status output (potential free),
-Control visualization by green LED,
-Output DC visualization by red LED,
-Built-in clamping voltage,
-Built-in free wheel diode,
-This product also includes a fuse on board to protect the
installation.
PXLA3010
New "Bistable" sensor
celduc relais has extended its range of bistable
magnetic proximity sensors with ref. PXLA3010.
PXLA3010 :
-Magnetic proximity sensor with reed switch
-1 bistable contact
-Switching power: 60W
Typical application : lifts
Sensors for lifts/elevators
http://www.celduc-relais.com/all/news/October/newsukv1015.html
01/03/2016
celduc relais Newsletter - October 2015
Page 3 sur 4
celduc relais offers different solutions which meet the lifts manufacturers
concerns, mainly safety. In fact, several types of controls must be done.
Locking and door position must be controlled accurately before authorizing
any movement of the cabin
Accurate checking of the position of the cabin compared to the « requested »
level asked by the user, to accept the opening of the lift in front of the floor
doors. The position of the floor doors must coincide exactly with the lift in order
to allow the door opening.
Accurate checking of the position of the cabin at the top or the botom of the
lift shaft.
Anytime, it is necessary to know the direction the cabin goes.
What type of products can celduc offer ?
PMG12802 - NO bistable
PMG13051 - NC
PMG13110 - NO
PXLA3010 - NO Bistable NEW
PMG12930 - NO
bistable
PCA22330 - NO
PCA36720 - NO
PCC12320 - Changeover
PCC26720 - Changeover
PCLA3030 - Bistable
PC2A2330 - 2xNO
PC3A2330 - 3xNO
Exhibitions - October 2015
http://www.celduc-relais.com/all/news/October/newsukv1015.html
01/03/2016
celduc relais Newsletter - October 2015
Page 4 sur 4
We are pleased to inform you that celduc products will be presented at the
following exhibitions :
-ELOSYS 2015 - TrenĨín - SLOVAKIA
From the 13th to 16th of October 2015
Exhibitor : Elmart s.r.o.
Website
-TransRail 2015 - Paris (Stade de France - St. Denis) - FRANCE
14th & 15th of October 2015
Exhibitor : celduc relais
Website
-HOST 2015 - Milan - ITALY
From the 23rd to 27th of October 2015
Exhibitor : celduc relais / Mechtex
Stand R22 & S21 Pavillon 24
Website
celduc relais
5 rue Ampère - BP30004
42290 SORBIERS France
Tel. Standard : +33 (0) 4 77 53 90 00
Tel. Sales department for France : +33 (0) 4 77 53 90 20
Tel. Sales department for Europe : +33 (0) 4 77 53 90 21
Tel. Sales department for Asia : + 33 (0) 4 77 53 90 19
Tel. Sales department for America : + 33 (0) 4 77 53 90 21
Tel. Purchasing department : +33 (0) 4 77 53 90 18
Tel. Financial and administrative : + 33 (0) 4 77 53 90 05
Fax : +33 (0) 4 77 53 85 51
E-mail : [email protected]
Website : www.celduc-relais.com
Google+
Community
You can delete your subscription at any time,
(according to the article 34 of the french law concerning the computer science laws).
To unsubscribe to the mailing list - click here
http://www.celduc-relais.com/all/news/October/newsukv1015.html
01/03/2016