Chemical seals for hygienic pressure applications DAxx series All stainless steel, flush diaphragm Rapid assembly and disassembly Fluid temperature up to 150°C depending on pressure, measuring device or mounting. 3-A authorization (N°1118) : - DANC, sterilization in place (SIP), cleaning in place (CIP) - DAEF, DAEL, DADF, DADL cleaning out of place Complies with FDA and EHEDG recommendations Wetted surface roughness: arithmetic average surface roughness Ra ≤ 32 µ inch (≤ 0.8 µm) Electropolishing option: housing and diaphragm arithmetic average surface roughness Ra ≤ 16 µ inch (≤ 0.4 µm), laser weld Ra ≤ 32 µ inch (≤ 0.8 µm) Diaphragm material : 1.4435 - Hastelloy option C276/2.4819 Hygienic seals are designed for systems needing contact surfaces that are rigorously clean and totally safe. The function of the chemical seal is to isolate the pressure gauge from the process fluid, preventing bacteria developing inside the pressure gauge’s sensing element. The fluid pressure being measured acts on the diaphragm and is transmitted to the pressure gauge by a neutral transmitting liquid. The quick release coupling and flush diaphragm facilitates easy cleaning. The following connection systems are offered : CLAMP system to NF E 29521, ISO 2852 and DIN 32676 standards NUT system to SMS 1145 standard NUT system to DIN 11 851 standard NUT system according to BS 4825 (RJT-IDF) CLAMP system compatible with VARIVENT® model Specifications Compatibility table of hygienic seals with pressure gauges (direct mounting) Fluid temperature: -20 ...100°C Range in bar according to the temperature Ambient temperature: -10 ... 50°C MEX2 (Ø50) - MEX3 (Ø63) DN25 (DANC/DADL/DAEL) 1"1/2 / DN32 - DN38 - DN40 + DAVA DN25 2"/ DN50 - DN51 + DAVA DN40/125 1"1/2 / DN32 - DN38 - DN40 + DAVA DN25 2"/ DN50 - DN51 + DAVA DN40/125 DN25 (1) MX35 (Ø100)** MEX5 (Ø100) 0 ... 4 to 0 ... 25 0 ... 4 to 0 ... 25 Not available 0 ... 2,5 to 0 ... 40 0 ... 2,5 to 0 ... 4 0 ... 6 to 0 ... 40 0 ... 1 to 0 ... 40 0 ... 1 (*) 0 ... 1,6 to 0 ... 40 -1 ... 3 to -1 ... 39 -1 ... 3 -1 ... 5 to -1 ... 39 -1 ... 1,5 to -1 ... 39 -1 ... 1,5 -1...3 to -1 ... 39 -1 ... 3 to -1+24 -1 ... 3 to -1 ... 24 Not available (*) class 2.5 (1) Fluid : -10°C + 100°C Fluid temperature: -20 ... 150°C Range in bar according to the temperature Ambient temperature: -10 ... 70°C MEX2 (Ø50) - MEX3 (Ø63) MX35 (Ø100)** DN25 (DANC/DADL/DAEL) 0 ... 6 to 0 ... 25 0 ... 6 to 0 ... 25 Not available 1"1/2 / DN32 - DN38 - DN40 + DAVA DN25 0 ... 4 to 0 ... 40 0 ... 4 to 0 ... 6 0 ... 10 to 0 ... 40 2" / DN50 - DN51 + DAVA DN40/125 0 ... 1,6 to 0 ... 40 0 ... 1,6 0 ... 2,5 to 0 ... 40 1"1/2 / DN32 - DN38 - DN40 + DAVA DN25 -1... 5 to -1 ... 39 -1 ... 5 -1 ... 9 to -1 ... 39 2" / DN50 - DN51 + DAVA DN40/125 -1 ... 3 to -1 ... 39 Not available -1 ... 3 to -1 ... 39 DN25 -1 ... 5 to -1 ... 24 -1 ... 5 to -1 ... 24 Not available (2) MEX5 (Ø100) (2) Fluid : -10°C + 120°C Note**: The MX35 is a pressure gauge DN100 stainless steel, class 1.6 specially designed to be mounted on seals only in the range above. D type and G½ connection exclusively. This pressure gauge is not available separately. Pressure gauge MEX2 (Ø50) - MEX3 (Ø63) : class 1.6 accuracy (20°C)MX35 (Ø100) : class 1.6 except 0+1 bar (class 2.5) (the MX35 has an MEX3 tube and block mounted in an MEX5 case) MEX5 (Ø100) : class 1 Max. range 0+40 bar or -1+39 bar www.baumer.com/process Design and specifications subject to change without notice Data sheet A43.01 Page 1 Range of hygienic seals, dimensions DANC (CLAMP according to NF E 29521 / ISO 2852 / DIN 32676 standards DAVA - VARIVENT® ØD ØB A 1 H Seal (EPDM) C Housing 1 Housing 2 Collar (option) 4 Endpiece (option) 3 DN Dimensions mm Dimensions mm DN to NF E 29521 ISO 2852 std DN to DIN 32676 std DN25 & 38 DN51 DN25 & 40 DN50 A ØB G½ ou or G¼ 50.5 G½ ou or G¼ 64 H 66 79 ~60 0.200 ~65 0.320 C 32 1) 32 1) 1) Other nominal diameters on request D Weight Kg ➀ +➁ DAVA VARIVENT DN A D S /Flats Weight Kg 25 40/125 G½ ou G¼ 50 27 0.200 G½ ou G¼ 68 27 0.320 ➀ for G¼, C = 30 DAEF (SMS 1145 with threaded housing DAEL (SMS 1145 with smooth housing) ØD ØB A 4 Nut S C A Housing 1 C Housing 1 2 Seal EPDM 3 Endpiece (option) 2 Seal EPDM 4 Nut (option) 3 Endpiece (option) ØB ØD Dimensions mm Model DN38 (1"½) DN51 (2") DN25 (1") DAEL (SMS 1145) DN38 (1"½) DN51 (2") DAEF (SMS 1145) A DN mm or in. ØB to SMS std dimensions Weight Kg C D ➀+➁+➂+➃ ➀+ ➁ Weight Kg ➀ + ➁ +➃ G½ or G¼ G½ or G¼ 60 x 1/6 70 x 1/6 32 32 74 84 ~55 ~55 0.400 G½ or G¼ 40 x 1/6 60 x 1/6 32 1) 33 1) 51 74 ~50 ~55 0.160 G½ or G¼ 0.300 0.540 G½ or G¼ 70 x 1/6 331) 84 ~60 0.420 0.730 Other nominal diameters on request www.baumer.com/process Design and specifications subject to change without notice 1) S 27 27 0.480 0.310 for G¼, C = 28 Data sheet A43.01 Page 2 DADF (DIN 11851 with threaded housing) DADL (DIN 11851 with smooth housing) ØD ØB A 4 Nut A C Housing 1 1 C Housing 2 Seal EPDM 2 Seal EPDM 3 Endpiece (option) 3 Endpiece (option) 4 Nut (option) ØB ØD Dimensions mm Model DN mm ØB A DN32 DN40 (DIN 11851) DN50 DN25 DN32 DADL (DIN 11851) DN40 DN50 to DIN std D ➀+➁+➂+➃ dimensions Weight Kg 0.360 ➀+ ➁ Weight Kg ➀+➁ + ➃ 58 x 1/6 65 x 1/6 40 2) 40 2) 70 78 ~58 G½ or G¼ ~59 0.460 G½ or G¼ 78 x 1/6 42 2) 92 ~63 0.580 0.230 0.420 0.290 0.500 G½ or G¼ DADF C 3) G½ or G¼ 52 x 1/6 G½ or G¼ G½ or G¼ 58 x 1/6 65 x 1/6 37 1) 37 1) 37 1) 63 70 78 ~59 ~62 ~63 0.360 0.610 G½ or G¼ 78 x 1/6 37 1) 92 ~65 0.530 0.880 Other nominal diameters on request 1) 2) 3) for G¼, C = 31 for G¼, C = 35 Reduced height option DARL (RJT according to BS 4825 part 5) DAIL (IDF according to BS 4825 part 4) ØD ØD 4 Nut 4 Nut S S A 1 Housing C C A 1 Housing 2 Seal EPDM DARL (RTJ) DN 3 Endpiece (option) 3 Endpiece (option) ØB Modèles DAIL (IDF) DAIL (IDF) 2 Seal EPDM ØB A B C D S /plats Hexagonal /flats Dimensions Encombrement Weight MassekgKg ➀+➁+➃ 1"½ 2" G½ ou or G¼ 50.7 8x1 64.2 8x1 35 27 60 75 27 27 60 52 540 G½ ou or G¼ 1"½ G½ ou or G¼ 58.4 8x1 38 65 27 60 440 2" G½ ou or G¼ 72.7 6x1 33 79 27 55 590 www.baumer.com/process Design and specifications subject to change without notice 700 Data sheet A43.01 Page 3 Limits of use If the temperature of the process fluid exceeds 150°C, a type ASIP D or equivalent cooling element needs to be fitted between the diaphragm seal and the measuring device. To keep 3-A requirements : • gaskets must be self centering and in accordance to 3-A material requirements • the fittings must be self draining and as short as possible (see drawings) • the weldings of fitting shall have a roughness Ra ≤ 0.8 µm (≤ 32 µ inch) • the pressure gauge mounted with the hygienic seal shall not have a window in standard glass 3° min. ok No acceptable no Ordering 1´ ... 2´ digit Model CLAMP SMS FF (6) SMS FL (6) DIN FF (6) DIN FL (6) IDF (1) RJT (1) VARIVENT® (1) 3´ ... 4´ digit Dimensions and types of top housing DN25 according to NF E 29521 ISO2852 DN38 according to NF E 29521 ISO2852 DN51 according to NF E 29521 ISO2852 DN25 according to DIN 32676 DN40 according to DIN 32676 DN50 according to DIN 32676 5´ ... 6´ digit DANC DAxxxxxxxx DA NC EF EL DF DL IL RL VA DN25 according to SMS 1145 DN38 according to SMS 1145 DN51 according to SMS 1145 DAEF/DAEL DN25 according to DIN 11851 DN32 according to DIN 11851 DN40 according to DIN 11851 DN50 according to DIN 11851 DADF/DADL 07 01 02 08 10 13 09 11 14 06 03 04 05 DN 1”1/2 IDF according to BS 4825 part 4 (1) DN 2” IDF according to BS 4825 part 4 (1) DAIL 15 16 DN 1”1/2 RJT according to BS 4825 part 5 (1) DN 2” RJT according to BS 4825 part 5 (1) DARL 17 18 DN 25 (1) DN 40/125 (1) DAVA 19 20 Top housing material Stainless steel 316L 7´ digit Top housing thread G1/2 female G1/4 female 1/2 NPT female 1/4 NPT female 8´digit Diaphragm material Stainless steel 316L Hastelloy C276 (please call our sales office) 9´ digit Type of assembly Complete assembly with collar and seal endpiece (1) (5) Upper housing alone (4) Upper housing with seal and nut or collar (2) Electropolished upper housing (4) Electropolished upper housing with seal (2) (4) Upper housing with seal (2) (4) Filling fluid (3) Code ** Operating temperature LRS 0 No filling LRS 1 -15° ... 150°C Application Application food and industry CODEX (FDA approved) LRS 2 -60° ... 150°C LRS 3 -20° ... 300°C Other applications LRS 4 -15° ... 150°C Oxygen–chlorinated products Max. P = 150 bar LRS7 -20° ... 80°C Paint application No vacuum scale available Filling under vacuum LRS10 -20° ... 225°C Food processing High temperature (FDA approved) 3-A Authorization DAxx mounted on pressure gauges MEX, MIX, MMX, MEP or transmitters E930/Y930 and TED/YTED pressure swichtches. Note: The "3-A" marking is applied on the associated device: (1) Codes incompatible with 3-A option (2) As standard, the EPDM seal is not compatible with option 3-A. Gaskets according to 3-A requirements on request for DANC ISO DN38 and DN51. Code : D ANC 01 2 x 2 x DANC 02 2 x 2 x (3) 3-A option only with filling fluids : LRS 1 and LRS 10 (4) Except for DADL, DAEL, DAIL and DARL. Use exclusively the models fitted with nuts (codes 1 or 3). (5) Except DANC according to DIN 32676. (6) 3A marked models only for cleaning out of place. 2 L H N 8 2 6 10´ digit 1 2 3 5 6 7 3-A Approval codification (option 1985) : please call our sales office www.baumer.com/process Design and specifications subject to change without notice Data sheet A43.01 Page 4 UK/12-2014 This data sheet may only be reproduced in full Family Chemical seal