Technical Data

D600
Diaphragm seal with extended process flange
Main Features
„„
Pressure range from 160 mbar
to 160 bar
„„
Temperature -60 °C … 200 °C
„„
Class 150 to 900
„„
NPS 1/2" to 2"1/2
„„
PN10 to PN160
„„
DN10 to DN65
Applications
„„Oil & Gas / Chemical
„„Water / Waste water
„„Energy
„„Process technic
Technical Data
Min.pressure ranges See table on page 2
The design of the extended process flange allows direct mounting on
standardized flange connections of pipes or tanks. The process flange
has through holes.
Different diaphragm materials can be selected to adapt the seal to
various applications and process fluids.
The diaphragm seals can be mounted to pressure gauges or pressure
switches directly or with a flexible capillary. For use with electronic
transmitters for pressure and differential pressure the product series
D9xx is recommended, especially for low pressure ranges.
Temperature
-60 °C ... +200 °C
Filling liquids
LRS1: -15 °C ... +150 °C
LRS9: -40 °C ... +200 °C high temperature oil
Other liquids on request
Mounting
Direct
Process flange
Stainless steel 1.4404 (AISI 316L) (1) with
extension
ASME B16.5 / EN1759-1:
class 150 to 900, NPS 1/2" to 2"1/2
EN1092-1:
PN 10 to 160, DN 10 to 65.
Available flange faces see table on page 4.
Other flange types on request.
Stainless steel 1.4435 (AISI 316L)
Option: Hastelloy, Uranus, Tantalum and Monel
400 (see ordering details on page 5)
Flange types
The filling fluid of the measuring system has to be choosen compatible
to the application.
Diaphragm
Maximum pressure
According to the PN or the class of the flange and
its standardized pressure temperature relation
Materials

N°




D621
Upper part

Stainless steel 1.4404
Process flange with
extension

Stainless steel 1.4404 (1)
Diaphragm




Stainless steel 1.4435 (1)
Gasket

D611
Fixing flanges (3)
Screws / nuts
D631
PTFE
_ (4)
Stainless steel 1.4301 (2)
Stainless steel 1.4301 (2)
Others materials see ordering details on page 5
1.4404 (316L) with option 1999
Stamped parts for D611 and D621
(4)
The upper part of the D631 is a flange directly mounted on the process flange
Design and specifications subject to change without notice
This diaphragm seals with flanged process connection are used
to protect pressure gauges from high temperatures, aggressive or
corrosive fluids.
(2)
(3)
www.baumer.com
Data sheet A42.23
Page 1 / 5
2015-11-10
(1)
D600
Diaphragm seal with extended process flange
Dimensions (mm)
Pressure limitations and dimensions of the upper part
ØB
100 to 150
Min. pressure ranges (1)
Type
Gauge
Compound
Pmax (2)
ØB
D611
0 ... 10 bar
-1 ... 9 bar
160 bar
85
D621
0 ... 1 bar
-1 ... 3 bar
40 bar
85
D631
0 ... 0.16 bar
-1 ... 0 bar
25 bar
120
N x ØL
C
(1)
Fluid temperature -20 ... 100 °C, ambiant temperature -10 ... 50 °C for pressure
gauges DN100/150/160, others on request.
The maximum pressure is also limited by the process flange.
f1
(2)
Ød1
ØK
ØD
Flange dimensions (mm) ANSI B16-5 / EN 1759-1
1/2"
3/4"
1"
1"1/4
(1)
ØD
ØK
ØL
N
EN1759-1
C (2)
f1 (2)
ANSI B16-5
C (2)
f1 (2)
Ø d1 (2)
Weight in kg (1)
D611
150
89
60.3
15.9
4
11.1
1.6
13.2
2
35.1
300
95
66.7
15.9
4
14.3
1.6
14.7
2
35.1
1.9
600
95
66.7
15.9
4
20.7
6.4
21.3
7
35.1
2.1
900
121
150
82.6
22.2
4
28.6
6.4
29.3
7
35.1
42.9
99
69.8
15.8
4
12.7
1.6
14.7
2
117
82.6
19
4
15.9
1.6
16.3
2
42.9
2.4
600
117
82.6
19
4
22.3
6.4
22.9
7
42.9
2.6
900
130
88.9
22.2
4
31.8
6.4
32.4
7
42.9
150
108
79.4
15.9
4
14.3
1.6
16.3
2
50.8
2.7
_
300
124
88.9
19
4
17.5
1.6
17.9
2
50.8
2.7
600
124
88.9
19
4
23.9
6.4
24.5
7
50.8
2.9
900
149
101.6
25.4
4
35
6.4
35.6
7
50.8
150
117
88.9
15.9
4
15.9
1.6
17.9
2
63.5
4.9
_
150
127
98.4
15.9
4
17.5
1.6
19.5
2
73.2
2"
150
152
120.6
19
4
19
1.6
21.1
2
91.9
2"1/2
150
178
139.7
19
4
22.2
1.6
24.3
2
104.6
D631
1.6
_
1.9
_
_
_
_
_
1.8
_
2.1
_
_
_
_
_
2.1
_
1.4
_
_
_
_
_
2.4
2.7
3
_
300
1"1/2
D621
_
_
_
2.7
_
_
_
3
3.9
5.5
Versions with "-" are not available.
For raised faces, codes G, R.
2015-11-10
(2)
Class
Design and specifications subject to change without notice
DN
www.baumer.com
Data sheet A42.23
Page 2 / 5
D600
Diaphragm seal with extended process flange
Flange dimensions (mm) EN 1092-1
PN
10
10
15
25
40
50
65
(1)
14
N
4
C (2)
16
f1 (2)
2
Ø d1 (2)
Weight in kg (1)
D611
D621
D631
40
_
1.9
2.2
90
60
14
4
16
2
40
1.9
2.2
25
90
60
14
4
16
2
40
_
1.9
2.2
1.9
_
40
90
60
14
4
16
2
40
_
10
95
65
14
4
16
2
45
_
2
2.3
16
95
65
14
4
16
2
45
_
2
2.3
25
95
65
14
4
16
2
45
_
2
2.3
2
_
40
95
65
14
4
16
2
45
_
63
105
75
14
4
20
2
45
2.5
_
_
_
100
105
75
14
4
20
2
45
2.5
_
160
105
75
14
4
20
2
45
3.5
_
_
58
_
2.3
2.6
105
75
14
4
18
2
16
105
75
14
4
18
2
58
_
2.3
2.6
25
105
75
14
4
18
2
58
_
2.3
2.6
2.3
_
40
105
75
14
4
18
2
58
_
63
130
90
18
4
22
2
58
3.3
_
_
_
100
130
90
18
4
22
2
58
3.3
_
10
115
85
14
4
18
2
68
_
2.6
2.9
16
115
85
14
4
18
2
68
_
2.6
2.9
25
115
85
14
4
18
2
68
_
2.6
2.9
2.6
_
40
115
85
14
4
18
2
68
_
63
140
85
18
4
24
2
68
3.8
_
_
_
100
140
100
18
4
24
2
68
3.8
_
160
140
100
18
4
24
2
68
4
_
_
78
_
3.2
3.5
140
100
18
4
18
2
16
140
100
18
4
18
2
78
_
3.2
3.5
25
140
100
18
4
18
2
78
_
3.2
3.5
3.2
_
40
140
100
18
4
18
2
78
_
10
150
110
18
4
18
3
88
_
3.6
3.9
16
150
110
18
4
18
3
88
_
3.6
3.9
25
150
110
18
4
18
3
88
_
3.6
3.9
3.6
_
40
150
110
18
4
18
3
88
_
10
165
125
18
4
18
3
102
_
_
4.4
102
_
_
4.4
_
4.7
5
165
125
25
185
135
10
185
145
16
4
18
18
4
20
3
102
_
18
8
18
3
122
_
_
_
5
_
5.8
18
3
16
185
145
18
8
18
3
122
_
25
185
145
18
8
22
3
122
_
Versions with "-" are not available.
For raised faces, code B.
2015-11-10
(2)
60
ØL
16
10
32
90
ØK
_
10
20
ØD
Design and specifications subject to change without notice
DN
www.baumer.com
Data sheet A42.23
Page 3 / 5
D600
Diaphragm seal with extended process flange
Ordering codes for flange faces
Face Type
Flat face
Drawing
ANSI B16-5
Codes
A
Flat face
Ra = 3.2...6.3 µm
Raised face (2)
Raised face (7) (3)
G
R
Ra = 3.2...6.3 µm
Male tongue large
Male tongue small (1)
H
I
Ra = 0.8...3.2 µm
Female groove
A
Type A
Type B (1.6)
Type B (6.4) (3)
(2)
Female groove large
Female groove small
G
R
K
L
Type DL
Type DS
H
I
Type E
A
Type A
Type B1
B
C
Type C
Ra = 0.8...3.2 µm
K
L
Ra = 0.8...3.2 µm
M
Codes
Ra = 3.2...12.5 µm
Ra = 0.8...3.2 µm
Ra = 0.8...3.2 µm
Male spigot large
Type CL
Type CS (1)
(1)
EN 1092-1
Ra = 3.2...6.3 µm
Ra = 3.2...6.3 µm
(1)
Male tongue
Codes
Ra = 3.2...6.3 µm
(2)
Raised face
EN 1759-1
D
Type D
Ra = 0.8...3.2 µm
M
Type E
E
Male Spigot
Ra = 3.2...6.3 µm
Female spigot large
Ra = 3.2...6.3 µm
O
Type FC
Ra = 3.2...12.5 µm
O
F
Type F
Female Spigot
Ra = 3.2...6.3 µm
Ring joint face
Ring joint face
Ra = 0.4...1.6 µm
(1)
(2)
Q
Type J
Ra = 3.2...12.5 µm
Q
N/A
Ra = 0.4...1.6 µm
Not applicable for 1"1/4 and 1"1/2
Class 150 and 300
Class 600 and 900
2015-11-10
Design and specifications subject to change without notice
(3)
Ra = 3.2...6.3 µm
www.baumer.com
Data sheet A42.23
Page 4 / 5
D600
Diaphragm seal with extended process flange
Ordering details D600
D6xx
–
.
.
Model
High pressure type
Medium pressure type
Low pressure type
Upper part
St. steel 1.4404 (316L)
Instrument connection
G1/2 female
G1/4 female
1/2 NPT female
1/4 NPT female
Diaphragm material
St. steel 316L (1.4435)
Uranus B6 (1.4539)
Hastelloy B2 (2.4617)
Hastelloy C276 (2.4819)
Tantalum
Monel 400
D611
D621
D631
Process flange coating (1)
0
1
3
4
–
2
1
2
3
5
6
9
C
D
E
F
L
H
N
8
2
3
5
6
7
9
Diaphragm coating
Without
PTFE 0.02 mm
HALAR 0.2 mm
Adhesive PTFE lining 0.25 mm (3)
Gold 15 µm
Process flange standard
ANSI B16-5
EN 1092-1
EN 1759-1
PN/Class
ANSI B16-5 / EN 1759-1
Class 150
Class 300
Class 600
Class 900
EN 1092-1
PN10
PN16
PN25
PN40
PN63
PN100
PN160
.
.
(2)
x
No coating
PTFE 0.02 mm
PTFE 2 mm (4)
HALAR 0.2 mm
Process flange material
Steel
St. steel 1.4404 (316L)
Uranus B6 (1.4539)
Hastelloy B6 (2.4617)
Hastelloy C276 (2.4819)
Monel 400 (2.4360)
PVC (5) max.10 bar/40 °C
PVDF (5) max.10 bar/80 °C or 16 bar / 40 °C
PPH (5) max.10 bar/60 °C
PTFE (5) max. 6 bar/80 °C
Flange face type
See table page 4 (codes)
DN
0
1
4
2
7
2
4
6
2
3
4
5
6
7
8
A
C
1 D
2 E
3 F
4 G
H
C J
D
F
G
N
J
P
ANSI B16-5 / EN 1759-1
1/2"
3/4"
1"
1"1/4
1"1/2
2"
2"1/2
EN 1092-1
10
15
20
25
32
40
50
65
No coating for flange facing types with groove, codes H, I, K, L, O, P, Q, C, D, F.
No diaphragm coatings on Tantalum diaphragms available.
(3)
Not for vacuum and compound pressure ranges.
(4)
Not for D611, max. 10 bar, max. 100 °C, only flange face A, B, G and R, DN ≤ 40 (1"1/2).
(5)
Only for D621 and D631.
(1)
2015-11-10
Design and specifications subject to change without notice
(2)
www.baumer.com
Data sheet A42.23