*T3 INTERFACE TRANSFORMER Turns Ratio ( + 2% ) 1:2CT PARAMETER MIN. Inductance 19 MAX. µHy Rise Time 3.00 nS Leakage Inductance 0.06 µHy Capacitance (CW/W) 10 pF Primary DC Resistance 0.3 ohms 1 Isolation Flammability: Materials used in the production of these units meet requirements of UL94-VO and IEC 695-2-2 needle flame test. UNITS 3000 Parts shipped in anti-static tubes. 44 pieces per tube Tape & Reel Available VRMS 3 dB Bandwidth is .200 - 340 (MHz) typical, tested in a 75 ohm system 1 Reinforced insulation * Also suitable for DS3, E3 and STS-1 interfaces PHYSICAL DIMENSIONS All dimensions in inches (mm): .260 (6.60) MAX. SCHEMATIC DIAGRAM 6 3 4 1 2 .410 (10.41) MAX. .410 (10.41) MAX. .020 (0.51) TYP. 5 .300 (7.62) MAX. .010 (0.25) TYP. .100 (2.54) TYP. .040 (1.02) TYP. .510 (12.95) .480 (12.19) RHOMBUS INDUSTRIES INC. FSCM NO. 16714 RHOMBUS P/N: T-13109G CUST P/N: NAME: DATE: 7/25/97 SHEET: Rhombus Industries Inc. Transformers & Magnetic Products 1 OF 1 15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 FAX: (714) 896-0971 www.rhombus-ind.com