Dielectric Withstanding Voltage Ratings

DIELECTRIC WITHSTANDING VOLTAGE RATINGS
FOR 90 SERIES, ICON, AND I2 MODULE TYPES
Table of Contents
SECTION 1 QUADRAPADDLE IN ICON SERIES
SECTION 2 QUADRAPADDLE IN 90 SERIES
SECTION 3 QUADRAPADDLE IN I2 SERIES
SECTION 4 TRIPADDLE IN ICON SERIES
SECTION 5 TRIPADDLE IN 90 SERIES
SECTION 6 MINI POWER IN 90 SERIES
DIELECTRIC WITHSTANDING VOLTAGE RATINGS
VIRGINIA PANEL CORPORATION
QUADRAPADDLE IN ICON SERIES MODULE
PART # 610 138 116 610 138 109 510 160 101 510 161 101
SPECIFICATIONS
CONTACT ARRANGEMENT
Available contact positions
160
Typical Breakdown Voltage
2.2 kVDC
1.3 kVAC
Dielectric Withstanding
Voltage (DWV)
1.5 kVDC
1.0 kVAC
Available contact positions
80
Typical Breakdown Voltage
3.5 kVDC
2.3 kVAC
Dielectric Withstanding
Voltage (DWV)
2.6 kVDC
1.7 kVAC
Available contact positions
ITA
Receiver
ITA
Receiver
40
Typical Breakdown Voltage
6.0 kVDC
4.2 kVAC
Dielectric Withstanding
Voltage (DWV)
4.5 kVDC
3.15 kVAC
NOTE: Maximum voltage applied during test was 6.0 kVDC
ITA
STANDARD VPC WIRE IS RATED TO A MAXIMUM OF 600
VDC. HIGHER RATED WIRE IS AVAILABLE UPON REQUEST.
USE CAUTION WHEN TESTING AT VOLTAGES HIGHER THAN
THE WIRE RATING FOR RISK OF ELECTRIC SHOCK.
For more information visit vpc.com
Receiver
Terminated Position
Unterminated Position
8/24/15
DIELECTRIC WITHSTANDING VOLTAGE RATINGS
VIRGINIA PANEL CORPORATION
QUADRAPADDLE IN 90 SERIES MODULE
PART # 610 138 116 610 138 109 510 150 115 510 151 105
SPECIFICATIONS
CONTACT ARRANGEMENT
Available contact positions
192
Typical Breakdown Voltage
2.1 kVDC
1.4 kVAC
Dielectric Withstanding
Voltage (DWV)
1.5 kVDC
1.0 kVAC
ITA
Receiver
Available contact positions
96
Typical Breakdown Voltage
3.3 kVDC
2.0 kVAC
Dielectric Withstanding
Voltage (DWV)
2.4 kVDC
1.5 kVAC
ITA
Receiver
Available contact positions
48
Typical Breakdown Voltage
5.8 kVDC
3.6 kVAC
Dielectric Withstanding
Voltage (DWV)
4.4 kVDC
2.7 kVAC
ITA
NOTE: Maximum voltage applied during test was 6.0 kVDC
Receiver
STANDARD VPC WIRE IS RATED TO A MAXIMUM OF 600
VDC. HIGHER RATED WIRE IS AVAILABLE UPON REQUEST.
USE CAUTION WHEN TESTING AT VOLTAGES HIGHER THAN
THE WIRE RATING FOR RISK OF ELECTRIC SHOCK.
For more information visit vpc.com
Terminated Position
Unterminated Position
8/24/15
DIELECTRIC WITHSTANDING VOLTAGE RATINGS
VIRGINIA PANEL CORPORATION
QUADRAPADDLE IN I2 SERIES MODULE
PART # 610 138 116 610 138 109 310 130 XXX 410 130 101
SPECIFICATIONS
CONTACT ARRANGEMENT
Available contact positions
168
Typical Breakdown Voltage
2.6 kVDC
1.6 kVAC
Dielectric Withstanding
Voltage (DWV)
1.5 kVDC
1.0 kVAC
ITA
Receiver
Available contact positions
84
Typical Breakdown Voltage
3.9 kVDC
2.3 kVAC
Dielectric Withstanding
Voltage (DWV)
2.9 kVDC
1.7 kVAC
ITA
Receiver
Available contact positions
42
Typical Breakdown Voltage
5.7 kVDC
3.6 kVAC
Dielectric Withstanding
Voltage (DWV)
4.3 kVDC
2.7 kVAC
ITA
NOTE: Maximum voltage applied during test was 6.0 kVDC
Receiver
STANDARD VPC WIRE IS RATED TO A MAXIMUM OF 600
VDC. HIGHER RATED WIRE IS AVAILABLE UPON REQUEST.
USE CAUTION WHEN TESTING AT VOLTAGES HIGHER THAN
THE WIRE RATING FOR RISK OF ELECTRIC SHOCK.
For more information visit vpc.com
Terminated Position
Unterminated Position
8/24/15
DIELECTRIC WITHSTANDING VOLTAGE RATINGS
VIRGINIA PANEL CORPORATION
TRIPADDLE IN ICON SERIES MODULE
PART # 610 110 101 610 110 108 510 160 108 510 161 108
SPECIFICATIONS
CONTACT ARRANGEMENT
Available contact positions
96
Typical Breakdown Voltage
3.0 kVDC
1.8 kVAC
Dielectric Withstanding
Voltage (DWV)
1.5 kVDC
1.0 kVAC
Available contact positions
48
Typical Breakdown Voltage
5.2 kVDC
2.7 kVAC
Dielectric Withstanding
Voltage (DWV)
3.9 kVDC
2.0 kVAC
Available contact positions
18
Typical Breakdown Voltage
6.0 kVDC
4.6 kVAC
Dielectric Withstanding
Voltage (DWV)
4.5 kVDC
3.5 kVAC
ITA
Receiver
ITA
Receiver
NOTE: Maximum voltage applied during test was 6.0 kVDC
ITA
STANDARD VPC WIRE IS RATED TO A MAXIMUM OF 600
VDC. HIGHER RATED WIRE IS AVAILABLE UPON REQUEST.
USE CAUTION WHEN TESTING AT VOLTAGES HIGHER THAN
THE WIRE RATING FOR RISK OF ELECTRIC SHOCK.
For more information visit vpc.com
Receiver
Terminated Position
Unterminated Position
8/24/15
DIELECTRIC WITHSTANDING VOLTAGE RATINGS
VIRGINIA PANEL CORPORATION
TRIPADDLE IN 90 SERIES MODULE
PART # 610 110 101 610 110 108 510 104 136 510 108 126
SPECIFICATIONS
CONTACT ARRANGEMENT
Available contact positions
96
Typical Breakdown Voltage
2.7 kVDC
1.5 kVAC
Dielectric Withstanding
Voltage (DWV)
1.5 kVDC
1.0 kVAC
ITA
Receiver
Available contact positions
32
Typical Breakdown Voltage
6.0 kVDC
3.7 kVAC
Dielectric Withstanding
Voltage (DWV)
4.5 kVDC
2.8 kVAC
ITA
NOTE: Maximum voltage applied during test was 6.0 kVDC
Receiver
STANDARD VPC WIRE IS RATED TO A MAXIMUM OF 600
VDC. HIGHER RATED WIRE IS AVAILABLE UPON REQUEST.
USE CAUTION WHEN TESTING AT VOLTAGES HIGHER THAN
THE WIRE RATING FOR RISK OF ELECTRIC SHOCK.
For more information visit vpc.com
Terminated Position
Unterminated Position
8/24/15
DIELECTRIC WITHSTANDING VOLTAGE RATINGS
VIRGINIA PANEL CORPORATION
MINI POWER IN 90 SERIES MODULE
PART # 610 116 112 610 115 125 510 104 123 510 108 115
SPECIFICATIONS
CONTACT ARRANGEMENT
Available contact positions
19
Typical Breakdown Voltage
2.4 kVDC
1.9 kVAC
Dielectric Withstanding
Voltage (DWV)
1.5 kVDC
1.0 kVAC
ITA
Receiver
Available contact positions
10
Typical Breakdown Voltage
6.0 kVDC
5.0 kVAC
Dielectric Withstanding
Voltage (DWV)
4.5 kVDC
3.7 kVAC
ITA
NOTE: Maximum voltage applied during test was 6.0 kVDC
Receiver
Test Conditions were as follows
Date: 5/11/2011
Temperature: 23°C (74°F)
Humidity: 40%
Pressure: 1017 hPa (30.03 inHg)
STANDARD VPC WIRE IS RATED TO A MAXIMUM OF 600
VDC. HIGHER RATED WIRE IS AVAILABLE UPON REQUEST.
USE CAUTION WHEN TESTING AT VOLTAGES HIGHER THAN
THE WIRE RATING FOR RISK OF ELECTRIC SHOCK.
For more information visit vpc.com
Terminated Position
Unterminated Position
8/24/15