201261516454361469

Test Report.
No. SHAEC1119944335
Date: 23 Mar 2012 .
Page 1 of 5.
JIANGSU CHANGJIANG ELECTRONICS TECHNOLOGY CO., LTD. .
78, CHANGSHAN RD, JIANGYIN, JIANGSU CHINA
.
.
The following sample(s) was/were submitted and identified on behalf of the clients as : SOP8 GREEN
PRODUCT-LEAD PART .
SGS Job No. :
SP11-037041 - SH .
Model No. :.
SOP8.
Sample May Cover : .
SOP16/20/24/28/30,HSOP28/34/38,SOP8/PP,SSOP10/16/20/24,MSOP8,MSOP
10,MSOP8/PP,MSOP10/PP,TSSOP8/14/16/20/24/28,TSSOP16/PP,TSSOP20/P
P,TSSOP24/PP,TSSOP24/PP-A,TSSOP28/PP .
Date of Sample Received : .
09 Dec 2011.
Testing Period : .
09 Dec 2011 - 23 Mar 2012 .
Test Requested : .
Selected test(s) as requested by client. .
Test Method : .
Please refer to next page(s). .
Test Results :.
Please refer to next page(s). .
Conclusion :.
Based on the performed tests on submitted samples, the results of Lead,
Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBB),
Polybrominated diphenyl ethers (PBDE) comply with the limits as set by RoHS
Directive 2011/65/EU Annex II; recasting 2002/95/EC. .
Signed for and on behalf of
SGS-CSTC Ltd. .
Fan Jingjie, JJ.
Approved Signatory .
0000655823
Test Report.
No. SHAEC1119944335
Date: 23 Mar 2012 .
Page 2 of 5.
Test Results :.
Test Part Description : .
Specimen No..
1.
SGS Sample ID.
SHA11-199443.006
Description.
Silvery metal pin part .
Remarks :.
(1) 1 mg/kg = 1 ppm = 0.0001% .
(2) MDL = Method Detection Limit .
(3) ND = Not Detected ( < MDL ) .
(4) "-" = Not Regulated .
RoHS Directive 2011/65/EU.
Test Method : . With reference to IEC 62321:2008
(1) Determination of Cadmium by ICP-OES.
(2) Determination of Lead by ICP-OES.
(3) Determination of Mercury by ICP-OES.
(4) Determination of Hexavalent Chromium by Spot test / Colorimetric Method using UV-Vis.
(5) Determination of PBBs / PBDEs by GC-MS. .
Test Item(s).
Limit.
Unit.
MDL.
006.
Cadmium (Cd) .
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
10
Mercury (Hg).
1,000
mg/kg.
2
ND
-
-
♢
Negative
1,000
mg/kg.
-
ND
Monobromobiphenyl .
-
mg/kg.
5
ND
Dibromobiphenyl .
-
mg/kg.
5
ND
Tribromobiphenyl .
-
mg/kg.
5
ND
Tetrabromobiphenyl .
-
mg/kg.
5
ND
Pentabromobiphenyl .
-
mg/kg.
5
ND
Hexabromobiphenyl .
-
mg/kg.
5
ND
Heptabromobiphenyl .
-
mg/kg.
5
ND
Octabromobiphenyl .
-
mg/kg.
5
ND
Nonabromobiphenyl .
-
mg/kg.
5
ND
Decabromobiphenyl .
-
mg/kg.
5
ND
1,000
mg/kg.
-
ND
-
mg/kg.
5
ND
Hexavalent Chromium (Cr(VI)) .
Sum of PBBs .
Sum of PBDEs .
Monobromodiphenyl ether .
0000655823
Test Report.
No. SHAEC1119944335
Date: 23 Mar 2012 .
Limit.
Unit.
MDL.
006.
Dibromodiphenyl ether .
-
mg/kg.
5
ND
Tribromodiphenyl ether .
-
mg/kg.
5
ND
Tetrabromodiphenyl ether .
-
mg/kg.
5
ND
Pentabromodiphenyl ether .
-
mg/kg.
5
ND
Hexabromodiphenyl ether .
-
mg/kg.
5
ND
Heptabromodiphenyl ether .
-
mg/kg.
5
ND
Octabromodiphenyl ether .
-
mg/kg.
5
ND
Nonabromodiphenyl ether .
-
mg/kg.
5
ND
Decabromodiphenyl ether .
-
mg/kg.
5
ND
Test Item(s).
Page 3 of 5.
Notes :.
(1) The maximum permissible limit is quoted from directive 2011/65/EU, Annex II
(2) ◇Spot-test:
Negative = Absence of CrVI coating, Positive = Presence of CrVI coating;
(The tested sample should be further verified by boiling-water-extraction method if the spot test result is
Negative or cannot be confirmed.)
◇Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is
equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
For corrosion protection coatings on metals: Information on storage conditions and production date of the
tested sample is unavailable and thus results of Cr(VI) represent status of the sample at the time of
testing..
0000655823
Test Report.
No. SHAEC1119944335
Date: 23 Mar 2012 .
Page 4 of 5.
ATTACHMENTS
RoHS Testing Flow Chart
1) Name of the person who made testing: Jan Shi/Yoyo Wang/Allen Xiao/Gary Xu
2) Name of the person in charge of testing: Jeff Zhang/George Xu/ Elim Lin
3) These samples were dissolved totally by pre-conditioning method according to below flow chart.
(Cr6+ and PBBs/PBDEs test method excluded)
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
Sample solvent
extraction
Filtration
Concentration/
Dilution of extraction
solution
Solution
+
Cr6
PBBs/PBDEs
Nonmetallic
material
Adding digestion
reagent
Residue
Positive
Spot test
Negative
Filtration
1) Alkali Fusion /
Dry Ashing
2) Acid to dissolve
Metallic
material
GC/MS
Heating to 90~95℃
for extraction
Filtration and pH
adjustment
DATA
ICP-OES
Adding 1,5diphenylcarbazide
for color
development
DATA
UV-Vis
DATA
0000655823
Boiling water
extraction
Adding 1,5diphenylcarbazide
for color
development
A red color
indicates the
6+
presence of Cr . If
necessary,
confirm with
UV-Vis.
DATA
Test Report.
No. SHAEC1119944335
Date: 23 Mar 2012 .
Sample photo: .
SHAEC1119944335
SHA11-199443.006 .
SGS authenticate the photo on original report only .
*** End of Report *** .
0000655823