Test Report No. CANEC0902652802 Date: 03 Jun 2009 Page 1 of 6 KINGTRONICS INTERNATIONAL COMPANY UNIT I,4/F DORMIND INDUSTRIAL BUILDING 13 YIP FUNG STREET FANLING N.T. HONG KONG The following sample(s) was/were submitted and identified on behalf of the clients as : CA42 EPOXY-COATED SOLID DIP TANTALUM ELECTROLYTC CAPACITOR SGS Job No. Date of Sample Received Testing Period : : : 11733815 - SZ 20 May 2009 20 May 2009 - 03 Jun 2009 Test Requested : Selected test(s) as requested by client. Test Method : Please refer to next page(s). Test Results : Please refer to next page(s). Conclusion : Based on the performed tests on submitted sample(s), the results comply with the RoHS Directive 2002/95/EC and its subsequent amendments. Signed for and on behalf of SGS-CSTC Ltd. Sunny Huang Lab Sr. Supervisor Test Report No. CANEC0902652802 Date: 03 Jun 2009 Page 2 of 6 Test Results: ID for specimen 1 Description for specimen 1 : CAN09-026528.001 : Brown body w/ dk-brown printing RoHS Directive 2002/95/EC Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium (CrVI) by alkaline extraction Sum of PBBs Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl Pentabromobiphenyl Hexabromobiphenyl Heptabromobiphenyl Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Sum of PBDEs Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether Pentabromodiphenyl ether Hexabromodiphenyl ether Heptabromodiphenyl ether Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether ## Unit mg/kg mg/kg mg/kg mg/kg Test Method (Reference) IEC 62321:2008, ICP-OES IEC 62321:2008, ICP-OES IEC 62321:2008, ICP-OES IEC 62321:2008, UV-Vis Result N.D. N.D. N.D. N.D. MDL 2 2 2 2 Limit 100 1000 1000 1000 mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg mg/kg IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS IEC 62321:2008, GC-MS N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. N.D. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 1000 Note: 1. mg/kg = ppm 2. N.D. = Not Detected (< MDL) 3. MDL = Method Detection Limit 4. ## = The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled by the European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE is included in the sum of PBDE after 01.07.2008 5. "-" = Not regulated 1000 Test Report ID for specimen 2 Description for specimen 2 No. CANEC0902652802 Date: 03 Jun 2009 Page 3 of 6 : CAN09-026528.002 : Silvery metal pin RoHS Directive 2002/95/EC Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium (CrVI) by boiling water extraction Unit mg/kg mg/kg mg/kg - Test Method (Reference) IEC 62321:2008, ICP-OES IEC 62321:2008, ICP-OES IEC 62321:2008, ICP-OES IEC 62321:2008, UV-Vis Result N.D. N.D. N.D. Negative MDL 2 2 2 ♢ Limit 100 1000 1000 # Note: 1. mg/kg = ppm 2. N.D. = Not Detected (< MDL) 3. MDL = Method Detection Limit 4. ◇= Spot test: Negative = Absence of CrVI coating, Positive = Presence of CrVI coating; (The tested sample should be further verified by boiling water extraction method if the spot test result is negative or cannot be confirmed.) Boiling water extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling water extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area. Storage conditions and production date of the tested sample are unavailable and thus results of Cr(VI) represent status of the sample at the time of testing. 5. # = Positive indicates the presence of CrVI on the tested area. Negative indicates the absence of CrVI on the tested area. 6. " " = Not regulated Remark 1:As requested by client, the test was conducted as whole / part sample, for the specimen 1 can’t be disjointed. Remark 2:Results & photo(s) of this report refer to test report CANEC0902652801. Test Report No. CANEC0902652802 Date: 03 Jun 2009 Page 4 of 6 Test Report No. CANEC0902652802 Date: 03 Jun 2009 Page 5 of 6 Test Report No. CANEC0902652802 Date: 03 Jun 2009 Sample photo: CANEC0902652802 CAN09-026528.001 CANEC0902652802 CAN09-026528.002 SGS authenticate the photo on original report only *** End of Report *** Page 6 of 6