canec0902652802

Test Report
No. CANEC0902652802
Date: 03 Jun 2009
Page 1 of 6
KINGTRONICS INTERNATIONAL COMPANY
UNIT I,4/F DORMIND INDUSTRIAL BUILDING
13 YIP FUNG STREET
FANLING
N.T. HONG KONG
The following sample(s) was/were submitted and identified on behalf of the clients as :
CA42 EPOXY-COATED SOLID DIP TANTALUM ELECTROLYTC CAPACITOR
SGS Job No.
Date of Sample Received
Testing Period
:
:
:
11733815 - SZ
20 May 2009
20 May 2009 - 03 Jun 2009
Test Requested
:
Selected test(s) as requested by client.
Test Method
:
Please refer to next page(s).
Test Results
:
Please refer to next page(s).
Conclusion
:
Based on the performed tests on submitted sample(s), the results comply
with the RoHS Directive 2002/95/EC and its subsequent amendments.
Signed for and on behalf of
SGS-CSTC Ltd.
Sunny Huang
Lab Sr. Supervisor
Test Report
No. CANEC0902652802
Date: 03 Jun 2009
Page 2 of 6
Test Results:
ID for specimen 1
Description for specimen 1
: CAN09-026528.001
: Brown body w/ dk-brown printing
RoHS Directive 2002/95/EC
Test Item(s)
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
Hexavalent Chromium (CrVI) by
alkaline extraction
Sum of PBBs
Monobromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Tetrabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
Sum of PBDEs
Monobromodiphenyl ether
Dibromodiphenyl ether
Tribromodiphenyl ether
Tetrabromodiphenyl ether
Pentabromodiphenyl ether
Hexabromodiphenyl ether
Heptabromodiphenyl ether
Octabromodiphenyl ether
Nonabromodiphenyl ether
Decabromodiphenyl ether ##
Unit
mg/kg
mg/kg
mg/kg
mg/kg
Test Method (Reference)
IEC 62321:2008, ICP-OES
IEC 62321:2008, ICP-OES
IEC 62321:2008, ICP-OES
IEC 62321:2008, UV-Vis
Result
N.D.
N.D.
N.D.
N.D.
MDL
2
2
2
2
Limit
100
1000
1000
1000
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
IEC 62321:2008, GC-MS
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
1000
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
4. ## = The exemption of DecaBDE in polymeric application according 2005/717/EC was overruled by the
European Court of Justice by its decision of 01.04.2008. Subsequently DecaBDE is included in the sum of
PBDE after 01.07.2008
5. "-" = Not regulated
1000
Test Report
ID for specimen 2
Description for specimen 2
No. CANEC0902652802
Date: 03 Jun 2009
Page 3 of 6
: CAN09-026528.002
: Silvery metal pin
RoHS Directive 2002/95/EC
Test Item(s)
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
Hexavalent Chromium (CrVI) by
boiling water extraction
Unit
mg/kg
mg/kg
mg/kg
-
Test Method (Reference)
IEC 62321:2008, ICP-OES
IEC 62321:2008, ICP-OES
IEC 62321:2008, ICP-OES
IEC 62321:2008, UV-Vis
Result
N.D.
N.D.
N.D.
Negative
MDL
2
2
2
♢
Limit
100
1000
1000
#
Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
4. ◇= Spot test:
Negative = Absence of CrVI coating, Positive = Presence of CrVI coating;
(The tested sample should be further verified by boiling water extraction method if the spot test result is
negative or cannot be confirmed.)
Boiling water extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling water extraction solution is equal
or greater than 0.02 mg/kg with 50 cm2 sample surface area.
Storage conditions and production date of the tested sample are unavailable and thus results of Cr(VI)
represent status of the sample at the time of testing.
5. # = Positive indicates the presence of CrVI on the tested area.
Negative indicates the absence of CrVI on the tested area.
6. " " = Not regulated
Remark 1:As requested by client, the test was conducted as whole / part sample, for the specimen 1 can’t be
disjointed.
Remark 2:Results & photo(s) of this report refer to test report CANEC0902652801.
Test Report
No. CANEC0902652802
Date: 03 Jun 2009
Page 4 of 6
Test Report
No. CANEC0902652802
Date: 03 Jun 2009
Page 5 of 6
Test Report
No. CANEC0902652802
Date: 03 Jun 2009
Sample photo:
CANEC0902652802
CAN09-026528.001
CANEC0902652802
CAN09-026528.002
SGS authenticate the photo on original report only
*** End of Report ***