Three Phase Filters F.LL.D3 series – SC type Residential / Light industrial environments High performance, slim, compact design This wide range of compact, three phase multistage filters offer a high level of attenuation performance across a broad frequency range for the suppression of inverters and power drive applications. Universal voltage and technical specifications ensure the range meets the needs of world-wide power drive systems and are ideally suited for long motor cable runs. • Current ratings from 8A to 130A • High attenuation performance • High voltage 520Vac design for worldwide applications • Multi-stage circuitry • Space saving, slim, lightweight enclosure • Safety block or cable output termination options Mechanical specifications Manufacture: aluminium enclosure Connections: R1 - safety terminal block 2 2 10mm solid wire, 6mm flex wire - 8A, 16A 2 2 16mm solid wire, 10mm flex wire - 30A, 42A 2 2 35mm solid wire, 25mm flex wire - 55A, 75A 2 50mm solid wire and flex wire - 100A, 130A Electrical specifications Cy (nF) 6x110 6x110 6x110 6x110 6x110 6x110 6x110 6x110 R (MΩ) 3x0.33 + 1x0.62 3x0.33 + 1x0.62 3x0.33 + 1x0.62 3x0.33 + 1x0.62 3x0.33 + 1x0.62 3x0.33 + 1x0.62 3x0.33 + 1x0.62 3x0.33 + 1x0.62 Circ Diag A A A A B B B C Circuit diagrams Load Cx (µF) 9x1 9x1 9x1 9x1 9x2.2 9x2.2 9x2.2 3x1.5 + 6x3.7 Load L (mH) 0.5 0.5 0.5 0.5 0.27 0.27 0.27 0.27 Load F.LL.D3.008A.SC. *1 F.LL.D3.016A.SC. *1 F.LL.D3.030A.SC. *1 F.LL.D3.042A.SC. *1 F.LL.D3.055A.SC. *1 F.LL.D3.075A.SC.R1 F.LL.D3.100A.SC.R1 F.LL.D3.130A.SC.R1 IR (A) 8 16 30 42 55 75 100 130 A Line Code B Line Filter range C Line W1 - output cable (8A - 55A only) Rated voltage (VR): 520Vac, 50/60 Hz Rated current (IR): referred to 50°C Leakage current (IL): normal condition: <3mA fault condition: 82mA max @ 520Vac 50 Hz Voltage test (2S.): line to ground 3470 Vdc line to line 1700 Vdc Climatic category: HMF (25/100/21): temperature range: -25°C to +100°C * = R - Safety Terminal Block or W - Output Cable Dimensions Code A B C D E F G H J L 0 PN N AWG 8A 255 126 50 225 240 25 6.5 300 2 9 M5 16 30A 335 150 60 305 320 35 6.5 400 2 9 M5 10 42A 329 185 70 300 314 45 6.5 500 3 12 M6 8 55A 329 185 80 300 314 55 6.5 500 3 12 M6 6 75A 329 220 80 300 314 55 6.5 100A 379 220 90 350 364 65 6.5 130A 439 240 110 400 414 80 6.5 3 3 6 M6 M10 M10 sizes, tri-rated cable Approvals 20 16A 305 142 55 275 290 30 6.5 300 2 9 M5 14 Made in accordance to VDE, UL and CSA requirements Three Phase Filters F.LL.D3 series – SC type Residential / Light industrial environments Dimensions (mm) and connections dB 100 90 80 70 60 50 40 30 20 10 0 Insertion loss (Typical) dB 100 .01 .1 .15 – – – Symmetrical (line to line) –––– Asymmetrical (line to ground) 1 10 30 90 80 70 60 50 40 30 20 10 0 .01 .1 .15 1 10 30 100 MHz dB 100 80 60 40 20 0 .01 100 MHz ...F.LL.D3.008A.SC.*1 dB 100 90 80 70 60 50 40 30 20 10 0 .1 .15 1 10 30 100 MHz ...F.LL.D3.016A.SC.*1 -20 .01 dB 100 dB 100 90 80 70 60 50 40 30 20 10 0 90 80 70 60 50 40 30 20 10 0 90 80 70 60 50 40 30 20 10 0 .1 .15 1 10 30 .01 100 MHz ...F.LL.D3.042A.SC.*1 dB 100 90 80 70 60 50 40 30 20 10 0 90 80 70 60 50 40 30 20 10 0 .1 .15 ...F.LL.D3.100A.SC.*1 .15 1 10 30 100 MHz ...F.LL.D3.055A.SC.*1 dB 100 .01 .1 1 10 30 100 MHz .01 .1 .15 .15 1 10 30 100 MHz 10 30 100 MHz ...F.LL.D3.030A.SC.*1 dB 100 .01 .1 .01 .1 .15 1 ...F.LL.D3.075A.SC.*1 1 10 30 100 MHz ...F.LL.D3.130A.SC.*1 21