s 148T

Panel Mount
Datasheet
Series 1T 480 VAC
• Ratings from 25A to 90A @ 48-530 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC or DC control
• Direct Bond Copper substrate
• Direct Power Lead Frame
• Epoxy Free Design
For Generation 3 datasheet click here
PRODUCT SELECTION
Control Voltage
3-32 VDC
90-280 VAC
AVAILABLE OPTIONS
48
50A
75A
90A
D4850T
A4850T
D4875T
A4875T
D4890T
A4890T
Rated Load Current
25: 25 Amps
50: 50 Amps
75: 75 Amps
90: 90 Amps
Control Voltage
A: 90-280 VAC
D: 3-32 VDC
A
25A
D4825T
A4825T
25
Operating
Voltage
48: 48-530 VAC
K
Thermal Pad
Blank: Not Included
H: Included
T
H
Termination
Blank: Screw
F: Quick Connect (1)
(Up to 50 Amps)
K: Hex standoffs (2)
Switching Type
Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On (3)
-10
Trigger Circuit
T: Phototransistor
Required for valid part number
For options only and not required for valid part number
* Not all part number combinations are available.
Contact Crydom Technical support for information on
the availability of a specific part number.
OUTPUT SPECIFICATIONS (4)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Maximum Load Current [Arms] (2)(5)
Minimum Load Current [mArms]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vrms] (6)
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]
Minimum Power Factor (at Maximum Load)
25A
50A
75A
90A
48-530
1200
10
500
25
40
239/250
1.15
0.8
285/259
0.5
48-530
1200
10
500
50
40
597/625
1.15
0.45
1779/1621
0.5
48-530
1200
10
500
75
40
954/1000
1.15
0.3
4555/4150
0.5
48-530
1200
10
500
90
40
1145/1200
1.15
0.27
6560/5976
0.5
INPUT SPECIFICATIONS (4)
Description
Control Voltage Range
Minimum Turn-On Voltage
Must Turn-Off Voltage
Minimum Input Current
Maximum Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
Do not forget to visit us at: www.crydom.com
D48xxT
A48xxT
3-32 VDC
3.0 VDC (7)
1.0 VDC
2.0 mA
2.5 mA
Current Regulated
1/2 Cycle (8)
1/2 Cycle
90-280 Vrms
90 Vrms
10 Vrms
2.0 mA
4.9 mA
60K
10
40
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
GENERAL SPECIFICATIONS (4)
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
4000 Vrms
109 Ohm
8 pF
-40 to 80 °C
-40 to 125 °C
2.6 oz (74.9 g)
94 V-0
Aluminum
13-15 / 1.5-1.7
18-20 / 2.0-2.2
18-20 / 2.0-2.2
w/”K” option 8-10 / 0.9-1.13
#6-32 UNC / #8-32 UNC
93% non-condensing
11,641,553 hours (1,328 years)
7,210,376 hours (823 years)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Housing Material
Baseplate Material
Input Terminal Screw Torque Range [in-lb/Nm]
Load Terminal Screw Torque Range [in-lb/Nm]
SSR Mounting Screw Torque Range [in-lb/Nm]
Input/Load Terminal Screw Torque Range [in-lb/Nm] (2)
Input/Output Terminal Screw Thread Size
Humidity per IEC60068-2-78
MTBF (Mean Time Between Failures) at 40°C ambient temperature (9)
MTBF (Mean Time Between Failures) at 60°C ambient temperature (9)
WIRING DIAGRAM
AC
1
2 ( )
2
OUTPUT
INPUT
Wire Pull-Out
Strength (lb)[N]
24 AWG (0.2 mm2) / 0.2 [minimum]
Input
2 x 12 AWG (3.3
Output
S O L I D S TAT E R E L AY
4
Wire Size
(Solid / Stranded)
Terminals
mm2)
10 [44.5]
/ 3.3 [maximum]
90 [400]
20 AWG (0.5 mm2) / 0.518 [minimum]
30 [133]
2 x 10 AWG (5.3 mm2) / 5.3
110 [490]
2 x 8 AWG (8.4 mm2) / 8.4 [maximum]
90 [400]
3
2.5
Input Current (mA)
Load (10)
1 ( )
Input Current vs Input Voltage
“T” Option - High Voltage Output
Recommended Wire Sizes
V
2
1.5
1
0.5
0
0
5
10
15
20
25
DC Input Voltage
4 (– / )
3 (+ / )
EQUIVALENT CIRCUIT BLOCK DIAGRAMS
Diagram: A48xxT
AC 4
1 AC
AC/DC
Converter
AC 3
Diagram: D48xxT
-DC 4
1 AC
Trigger
Circuit
Trigger
Circuit
2 AC
Do not forget to visit us at: www.crydom.com
+DC 3
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Current
Limiter
2 AC
30
Panel Mount
Datasheet
MECHANICAL SPECIFICATIONS (4)
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
Screw Termination
1.1
[27.9]
0.49
[12.4]
1
1.88
[47.6]
OUTPUT
INPUT
1.1
[27.9]
0.49
[12.4]
0.89
[22.6]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
1
2
2.25
[57.3]
1.7
[43.2]
S O L I D S TAT E R E L AY
4
Hex Standoff Termination (“K” Option) (2)
1.88
[47.6]
OUTPUT
INPUT
1.58
[40.2]
0.49
[12.4]
1
1.88
[47.6]
OUTPUT
Faston Terminal(11)
0.25 x 0.032
INPUT
1.40
[35.6]
1.75
[44.5]
(4 places)
1.0
[25.4]
Quick Connect Termination (“F” Option) - Up to 50 Amp (1)
1.31
[33.4]
2
2.25
[57.3]
1.88
[47.6]
3
OUTPUT
(2 places)
1.25
[31.8]
GENERAL NOTES
1.31
[33.4]
0.45
[11.4]
2
INPUT
0.49
[12.4]
1.40
[35.6]
1.75
[44.5]
2.25
[57.3]
1.7
[43.2]
S O L I D S TAT E R E L AY
4
Faston Terminal(11)
0.187 x 0.020
(4 places)
(2 places)
1
1.7
[43.2]
Faston Terminal(11)
0.25 x 0.032
1.58
[40.2]
0.63
[16.0]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
(2 places)
S O L I D S TAT E R E L AY
4
0.93
[23.6]
(2 places)
Quick Connect Termination (“F” Option) - Up to 25 Amp (1)
Mounting
Hole/Slot
0.19 [4.9]
DIA.
3
1.75
[44.5]
1.75
[44.5]
2.25
[57.3]
1.70
[43.2]
1.0
[25.4]
1.0
[25.4]
1.04
[26.4]
2
S O L I D S TAT E R E L AY
4
3
Mounting
Hole/Slot
0.19 [4.9]
DIA.
3
Faston Terminal(11)
0.187 x 0.020
(2 places)
1.25
[31.8]
(1) Single pair (up to 25A) Double pair* (50A model only). *Caution: User must connect to both pairs.
(2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps.
For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support.
(3) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only.
(4) All parameters at 25°C unless otherwise specified.
(5) Heat sinking required, see derating curves
(6) For 40mA minimum current, the voltage drop increases over maximum rated.
(7) For relays with option “G” minimum control voltage is 4.5VDC.
(8) Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models).
(9) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(10) Load can be wired to either SSR output terminal 1 or 2.
(11) Mechanical dimensions vary from G3 models.
For additional information or specific questions, contact Crydom Technical Support.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
SURGE CURRENT INFORMATION
50 A
600
200
500
Surge Current (Amp)
Surge Current (Amp)
25 A
250
150
100
50
0
0.01
0.1
1
400
300
200
100
0
0.01
10
0.1
Surge Duration (Secs)
1
90 A
Surge Current (Amp)
Surge Current (Amp)
75 A
900
800
700
600
500
400
300
200
100
0
0.01
10
Surge Duration (Secs)
0.1
1
10
1200
1050
900
750
600
450
300
150
0
0.01
0.1
Surge Duration (Secs)
1
10
Surge Duration (Secs)
Non repetitive peak surge current at Tj initial 40ºC.
THERMAL DERATE INFORMATION
25 A
1.5ºC/W
50 A
2ºC/W
0.7ºC/W
3ºC/W
20
15
10
5
0
20
30
40
50
60
70
40
30
20
10
0
80
20
30
40
75 A
0.5ºC/W
0.7ºC/W
0.5ºC/W
1.5ºC/W
Load Current (Amps)
Load Current (Amps)
60
45
30
15
30
40
50
60
70
80
90 A
1ºC/W
75
20
50
Ambient Temperature (ºC)
Ambient Temperature (ºC)
0
2ºC/W
1.5ºC/W
50
Load Current (Amps)
Load Current (Amps)
25
1ºC/W
60
70
80
Ambient Temperature (ºC)
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
90
80
70
60
50
40
30
20
10
0
20
30
0.7ºC/W
40
50
1ºC/W
60
Ambient Temperature (ºC)
1.5ºC/W
70
80
Panel Mount
Datasheet
AGENCY APPROVALS
EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:
Designed in accordance with the requirements of IEC 62314
IEC 61000-4-2 : Electrostatic Discharge – Level 3
IEC 61000-4-4 : Electrically Fast Transients – Level 3
IEC 61000-4-5 : Electrical Surges – Level 3
IEC 60068-2-6 : Vibration 0.33mm and 0.75 mm Amplitude over 10-55 Hz
IEC 60068-2-27 : Shock Resistance 15g/11ms
E116949
LR81689
10143 UG
ACCESORIES
Recommended Accessories
New Accessories!
Protective Cover & Hardware Kits
Protective Cover
Part number: KS101
Clear plastic cover compatible with all new
S1 designs. Safety covers provide added
protection from electric shock when
installing or checking equipment.
Cover
Hardware
Kit
KS101
HK1
HS501DR
5.0
TRM1
HSP-1
HK4
HS301 / HS301DR
3.0
TRM6
HSP-2
HS251
2.5
HS202 / HS202DR
2.0
HS201 / HS201DR
2.0
HS172
1.7
HS151 / HS151DR
1.5
HS122 / HS122DR
1.2
HS103 / HS103DR
1.0
HS101
1.0
HS073
0.7
HS072
0.7
Hardware Kit
Part number: HK4
Bag with 2 square brass accessories and 2
screw 8-32 x 5/8 for output. Used to mount
TMR1 lug terminals.
Heat Sink
Part No.
Thermal Resistance Lug Terminal Thermal Pad
[ºC/W]
HS053
0.5
HS033
0.36
HS023
0.25
Rev. 041116
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Panel Mount
Datasheet
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险
HAZARD OF
ELECTRIC
SHOCK,
EXPLOSION,
OR ARC FLASH.
• Disconnect all
power before
installing or
working with
this equipment.
• Verify all
connections
and replace all
covers before
turning on
power.
Failure to follow
these
instructions will
result in death
or serious injury.
RIESGO DE
DESCARGA
ELECTRICA O
EXPLOSION.
• Desconectar
todos los
suministros de
energia a este
equipo antes
de trabajar
con este equipo.
• Verificar todas
las conexiones
y colocar todas
las tapas antes
de energizer
el equipo.
El
incumplimiento
de estas
instrucciones
puede provocar
la muerte o
lesiones serias.
RISQUE DE
DESCHARGE
ELECTRIQUE
OU EXPLOSION
• Eteindre
toutes les
sources
d'énergie de
cet appareil
avant de
travailler
dessus de cet
appareil
• Vérifier tous
connections, et
remettre tous
couverts en
olace avant de
mettre sous
De non-suivi de
ces instructions
provoquera la
mort ou des
lésions sérieuses
sérieuses.
GEFAHR EINES
ELEKTRISCHE
N SCHLAGES
ODER EINER
EXPLOSION.
• Stellen Sie
jeglichen
Strom ab, der
dieses Gerät
versorgt, bevor
Sie an dem
Gerät Arbeiten
durchführen
• Vor dem
Drehen auf
Energie alle
Anschlüsse
überprüfen
und alle
Abdeckungen
ersetzen.
Unterlassung
dieser
Anweisungen
können zum
Tode oder zu
schweren
Verletzungen
führen.
RISCHIO DI
SCOSSA
ELETTRICA O
DELL’ESPLOSIONE.
• Spenga tutta
l'alimentazione
che fornisce
questa
apparecchiatura
prima di lavorare
a questa
apparecchiatura
存在电击、
爆炸或电弧
闪烁危险
•
在操作此设
备之前请先
关闭电源。
若不遵守这些说明,
可能会导致严重的
人身伤害甚至死亡。
• Verificare tutti
i collegamenti
e sostituire
tutte le coperture
prima
dell’accensione
L'omissione di
queste istruzioni
provocherà la
morte o
lesioni serie
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告
RISK OF MATERIAL DAMAGE AND HOT
ENCLOSURE
RISQUE DE DOMMAGE MATERIEL ET DE
SURCHAUFFE DU BOITIER
GEFAHR VON MATERIALSCHÄDEN UND
GEHÄUSEERHITZUNG
• The product's side panels may be hot, allow
the product to cool before touching.
• Follow proper mounting instructions including
torque values.
• Do not allow liquids or foreign objects to enter
this product.
• Les panneaux latéraux du produit peuvent être
chauds. Laisser le produit refroidir avant de le
toucher.
• Respecter les consignes de montage, et
notamment les couples de serrage.
• Ne pas laisser pénétrer de liquide ni de corps
étrangers à l'intérieur du produit.
• Die Seitenwände können heiß sein. Lassen Sie
das Produkt abkühlen, bevor Sie es berühren.
• Beachten Sie die Montageanweisungen,
• Führen Sie keine Flüssigkeiten oder
Fremdkörper in das Produkt ein.
Le non-respect de cette directive peut entraîner,
Failure to follow these instructions can result in des lésions corporelles graves ou des
serious injury, or equipment damage.
dommages matériels.
Die Nichtbeachtung dieser Anweisung kann
Körperverletzung oder Materialschäden
zur Folge haben.
RIESGO DE DAÑOS MATERIALES Y DE
SOBRECALENTAMIENTO DE LA UNIDAD
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO
CALDO
材料损坏和高温外壳的危险性
• Los paneles laterales del producto pueden
estar calientes. Esperar que el producto se
enfríe antes de tocarlo.
• Respetar las instrucciones de montaje, y en
particular los pares de apretado.
• No dejar que penetren líquidos o cuerpos
extraños en el producto.
• I pannelli laterali dell'apparecchio possono
scottare; lasciar quindi raffreddare il prodotto
prima di toccarlo.
• Seguire le istruzioni di montaggio corrette.
• Non far entrare liquidi o oggetti estranei in questo
apparecchio.
Si no se respetan estas precauciones pueden
producirse graves lesiones, daños materiales.
La mancata osservanza di questa precauzione può
causare gravi rischi per l'incolumità personale o
danni alle apparecchiature.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
• 产品的一侧面板可能很热,在其冷却前请
不要触碰。
• 遵照正确的安装说明,包括扭矩值。
• 请勿让液体及其他异物进入本产品。
如不能正确执行这些操作说明,
极有可能造成严重人体伤害或者设备的损坏。
Panel Mount
Datasheet
ANNEX - ENVIROMENTAL INFORMATION
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.
Part
Name
Toxic or hazardous Substance and Elements
Lead
(Pb)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr (VI))
Polybrominated
biphenyls
(PBB)
Polybrominated
diphenyl ethers
(PBDE)
Semiconductor die
Solder
附件 - 环保信息
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,
电子信息产品污染控制标识要求。
部件
名称
铅
汞
镉
有毒有害物质或元素
六价铬
多溴联苯
(Pb)
(Hg)
(Cd)
(Cr (VI))
半导体芯片
焊接点
50
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
(PBB)
多溴二苯醚
(PBDE)