Click Here to download this file: /data/acdcsupplies/cps_d1u4cs-w-2200-12.pdf

D1U4CS-W-2200-12-HxxC Series
www.murata-ps.com
AC/DC Front End Power Supply
PRODUCT OVERVIEW
The D1U4CS-W-2200-12-HxxC is a 2200 Watt, power-factor-corrected (PFC) front-end power supply for hot-swapping redundant systems. The main output is 12V with a standby output of 5V or 3.3V. Packaged in a 1U low profile
enclosure, it is designed to deliver reliable bulk power to servers, workstations, storage systems or any 12V distributed power architecture systems requiring high power density. The highly efficient electrical and thermal design with
internal cooling fans supports reliable operation conditions. The D1U4CS-W-2200-12-HxxC is designed to autorecover
from overtemperature fault. Status information is provided with front panel LEDs, logic signals and an I2C management interface. Four units can be packaged into an optional 19" 1U power shelf to provide up to 8.8kW of power.
ORDERING GUIDE
Power Output
High Line AC
Model Number
FEATURES

2200W (220Vac), 1100W (110Vac)
Output Power

Certified to Climate Savers Computing InitiativeSM
and 80 PLUS® Gold efficiency

12V Main Output, 3.3V or 5V Standby Output

1U height: 4.0" x 14.0" x 1.6"

24.5 Watts per cubic inch density

N+1 redundancy capable, including hot plugging
(up to 4 in parallel)

Active Current Sharing on main output; ORing FET

Overvoltage, Overcurrent,
Overtemperature protection

Internal cooling fans (variable speed)

I²C Bus Interface, PSMI compliant

RoHS compliant
D1U4CS-W-2200-12-HC4C
D1U4CS-W-2200-12-HC3C
D1U4CS-W-2200-12-HA4C
D1U4CS-W-2200-12-HA3C
2200W
2200W
2200W
2200W
Power Output
Low Line AC
1100W
1100W
1100W
1100W
Main
Output
12.12V
12.12V
12.12V
12.12V
Standby
Output
3.3V
3.3V
5V
5V
Airflow
Back to front
Front to back
Back to front
Front to back
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Input Current
Inrush Current
Power Factor
Conditions
Ramp up
Ramp down
Low Line AC 90Vac
High Line AC 180Vac
Cold start between 0-1msec
Output load >90%
Output load >50%
Min.
Typ.
90
47
81
70.5
115/230
60
Max.
Units
264
63
89
78
13
13
16.5
Vac
Hz
Vac
Arms
Apk
0.95
0.95
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage

Optional 1U x 19" Power-Shelf
12V
5Vsb
3.3Vsb
Parameter
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Output Current
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise1
Operating Range
Load Capacitance
Conditions
Min.
Typ.
Max.
12.12
11.76
12.48
120
180
30000
20MHz Bandwidth
9
5
20MHz Bandwidth
4.85
5.15
50
5
10000
0
3.3
20MHz Bandwidth
3.2
0
3.4
50
6
10000
Units
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
Vdc
mV p-p
A
μF
1 Ripple and noise are measured with 0.1 uF of ceramic capacitance and 10 uF of tantalum capacitance on each of the power supply outputs. The output
noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial cable with 50ohm scope termination is used.
For full details go to
www.murata-ps.com/rohs
CB
Test Certificate
and Test Report
www.murata-ps.com/support
CPS_D1U4CS-W-2200-12-HxxC.A09 Page 1 of 6
D1U4CS-W-2200-12-HxxC Series
AC/DC Front End Power Supply
OUTPUT CHARACTERISTICS
Parameter
Remote Sense
Efficiency (230V) excluding fan load
Output Rise Monotonicity
Startup Time
Transient Response
Conditions
Typ.
Max.
Units
120
mV
20% load
88
89.1
50% load
92
93.0
%
100% load
88
92.2
Overshoot less than 10% for all outputs, no voltage negative between 10% to 95% during ramp up
AC ramp up
1.5
s
PS_On activated
150
ms
12V Ramp 1A/μs
±360
5Vsb Ramp 1A/μs
±150
mV
3.3Vsb Ramp 1A/μs
±100
Current sharing accuracy (up to 4 in parallel)
At 100% load
Hot Swap Transients
Holdup Time
All outputs remain in regulation
100% load
Min.
±7
%
5
%
ms
Max.
70
Units
12
ENVIRONMENTAL CHARACTERISTICS
Parameter
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Storage Humidity
Shock
Sinusoidal Vibration
MTBF
Acoustic
Safety Approvals
Input Fuse
Material Flammability
Switching Frequency
Weight
Conditions
Non-condensing
Min.
-40
Typ.
D1U4CS-W-2200-12-HC4C and D1U4CSW-2200-12-HA4C models
0
50
D1U4CS-W-2200-12-HC3C and D1U4CSW-2200-12-HA3C models
0
40
10
5
90
90
Non-condensing
30G non operating
0.5G, 5 – 500 Hz operating
Calculated per Bellcore at Ta=30°C
400K
Demonstrated
400K
ISO 7779-1999
60
CAN/CSA C22.2 No 60950-1-07, Am.1:2011
UL 60950-1-2011, 2nd Ed.
UL 60950-1, 2nd Ed.
IEC60950-1:2005 (2nd Ed.) w A1:2009, EN 60950-1:2006+A11:2009 +A1:2010 +A12:2011
Power Supply has internal 20A/250V fast blow fuse on the AC line input
UL 94V-0
TBD
4.5lbs (2.1kg)
°C
%
hrs
hrs
dB LpAm
PROTECTION CHARACTERISTICS
Output
Voltage
12V
5Vsb
3.3Vsb
Parameter
Conditions
Min.
Overtemperature
Overvoltage
Overcurrent
Overvoltage
Overcurrent
Overvoltage
Overcurrent
Autorestart
Latching
Latching
Latching
Brick wall, autorecovery
Latching
Brick wall, autorecovery
55
13.1
197
5.6
5.5
3.5
6.5
Typ.
Max.
Units
65
14.1
225
6.2
6.2
4.0
8.0
°C
V
A
V
A
V
A
www.murata-ps.com/support
CPS_D1U4CS-W-2200-12-HxxC.A09 Page 2 of 6
D1U4CS-W-2200-12-HxxC Series
AC/DC Front End Power Supply
ISOLATION CHARACTERISTICS
Parameter
Insulation Safety Rating / Test Voltage
Isolation
Grounding
Conditions
Min.
Typ.
Max.
Units
Input to Output - Reinforced
3000
Vrms
Input to Chassis - Basic
1500
Vrms
Output to Chassis
Output to Output
Main Output Return and Standby Output Return are connected internally. 100kΩ resistor parallel with 100nF
capacitor is connected between Return and power supply chassis. Main Output Return should be connected to
the System Chassis
STATUS INDICATORS AND CONTROL SIGNALS
Status
Conditions
Off
Flashing Green
Flashing Amber
LEDs
Solid Amber
I2C Registers
Solid Green
Refer to Application Note #ACAN-33
Description
No AC to all Power Supply
Main Output Absent
Calibration Mode; not a normal operating condition
PW Fail or PWOK Low.
Note: The LED will also show Solid Amber if the power module is:
1. Not correctly installed within its slot (in the host system shelf)
with PS_KILL (Pin B5) correctly terminated.
2. Operated externally (as a standalone power module) and is not
connected to an Output Connector Card ACAN-32 (see Optional
Accessories) that correctly terminates PS_KILL (Pin B5).
Power Supply Good
EMISSIONS AND IMMUNITY
Characteristic
Input Current Harmonics
Voltage Fluctuation and Flicker
Conducted Emissions
Radiated Emissions
Standard
IEC/EN 61000-3-2
IEC/EN 61000-3-3
FCC 47 CFR Part 15/CISPR 22/EN55022
FCC 47 CFR Part 15/CISPR 22/EN55022
ESD Immunity
IEC/EN 61000-4-2
Radiated Field Immunity
Electrical Fast Transients/Burst Immunity
Surge Immunity
RF Conducted Immunity
Magnetic Field Immunity
Voltage dips, interruptions
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
Compliance
Complies
Complies
Class A, 6dB margin
Class A, 6dB margin
4kV contact discharge
8kV operational air discharge
15kV non-operational air discharge
Complies
Complies
1kV/2kV, Performance Criteria A
3 Vac, 80% AM, 1kHz, Performance Criteria A
3 A/m
Complies
www.murata-ps.com/support
CPS_D1U4CS-W-2200-12-HxxC.A09 Page 3 of 6
D1U4CS-W-2200-12-HxxC Series
AC/DC Front End Power Supply
OUTPUT CONNECTOR AND SIGNAL SPECIFICATION
DC and Signal Connector: FCI PowerBlade # 51732-048LF
P1
VOUT
P2
VOUT
P3
VOUT
P4
VOUT
P5
VOUT
P6
P7
VRTN
VRTN
P8
VRTN
P9
VRTN
P10
x1
x2
x3
x4
x5
x6
AC_OK/H
PW_OK/H
Vsb
RETURN
Vsb
RETURN
Vsb
+OUT
Vsb
+OUT
D
SPARE
SMB/
Alert
Vsb
RETURN
Vsb
RETURN
Vsb
+OUT
Vsb
+OUT
C
I_SHARE
I2C ADR0
I2C ADR1
I2C ADR2
PS_KILL
PS_
PRESENT
B
SENSE +
SENSE -
I2C DATA
I2C
CLOCK
SPARE
PS_ON/L
A
VRTN
mate-last pins
High Level
Low Level
Pin Assignment
Signal Name
Description
I Max
P1 to P5
P6 to P10
VOUT
VRTN
Main output voltage
Main output voltage, return
A1
Sense +
VOUT remote sense, positive node input, connected to the
+ve load point
A2
Sense -
VOUT remote sense, negative node input, connected to the
-ve load point
C5, C6, D5, D6
C3, C4, D3, D4
B1
Vsb
Vsb Return
I_Share
Standby voltage output
Standby voltage, return, tied internally to Output Return
Active load sharing bus
0 – 8V
-4 mA / +5 mA
D1
AC_OK/H
Input AC Voltage “OK” signal output (Internal pull up is
10kΩ to Vsb)
>2.1V
<0.8V
+4 mA
-2 mA
D2
PW_OK/H
Internal pull up of 10KΩ to Vsb
>2.1V
<0.8V
+4 mA
-2 mA
C2
SMB/Alert
SMB/Alert signal output (open collector)
B5
PS_Kill
Floating pin will turn off P/S (shorter pin, last-make and
first-break contact for hot plugging). This signal overrides
PS-On in disabling the Main Output
>2.1V (open)
<0.8V (active, PS:On)
N/A
B6
PS_Present
Internally tied to Vsb Return
0V
A6
PS_On/L
Internal 3.3KΩ pull-up to Vsb (accepts open collector/ drain
drive). This signal to be pulled low to turn-on power supply
A3
A4
I2C Data
I2C Clock
I2C serial data bus; internal 4.64KΩ pull-up to Vsb
I2C serial clock bus; internal 4.64KΩ pull-up to Vsb
B2
I2C Adr0
Address input 0, internal 10KΩ pull-up to Vsb
>2.1V
<0.8V
±1 mA
B3
I2C Adr1
Address input 1, internal 10KΩ pull-up to Vsb
>2.1V
<0.8V
±1 mA
B4
I2C Adr2
Address input 2, internal 10KΩ pull-up to Vsb
>2.1V
<0.8V
±1 mA
>2.1V (open, or 3.3V)
<0.8V (active, PS:On)
D1U4CS MATING CONNECTORS
12V D1U4 mating connector
Solder 1
Press Fit
Straight
Murata-PS
FCI
N/A
51742-11002400AALF
Right Angle
4321-01454-0
51762-11002400ABLF
Straight
N/A
N/A
Right Angle
N/A
N/A
1 Solder connector recommended for board thickness of <0.090
www.murata-ps.com/support
CPS_D1U4CS-W-2200-12-HxxC.A09 Page 4 of 6
D1U4CS-W-2200-12-HxxC Series
AC/DC Front End Power Supply
WIRING DIAGRAM FOR OUTPUT
Dotted lines show optional remote sense connections.
Optional remote sense lines can be attached to a load that is a distance
away from the power supply to improve regulation at the load.
Sense + (Main Output Remote Sense)
A1
P1-P5
Sense + (Main Output Remote Sense)
VOUT
VOUT
P1-P5 A1
D1U4CS
12V load
D1U4CS
P6-P10
VRTN
VRTN
P6-P10
A2
Sense –
Sense –
A2
B1
I_Share
I_Share
B1
C5,C6,D5,D6
A6
Vsb
Vsb
PS_On
PS_On
Close switch (or FET, BJT, or wire)
to turn on +12V OUT
C3,C4,D3,D4
B5
Vsb Return
C5,C6,D5,D6
A6
Vsb logic circuitry
Vsb Return
C3,C4,D3,D4
PS_Kill
PS_Kill
B5
CURRENT SHARING NOTES
12V Output: Current sharing is achieved using the active current share method. (See wiring diagram for connection details.)
The total combined load must be below 2200W at startup. Current sharing can be achieved with or without remote sense connected to the common load.
VSB outputs can be tied together for redundancy but total combined output power must not exceed 25W. The VSB output has internal ORing MOSFET for additional redundancy /
internal short protection.
The current share pin B1 is a connection between the two units. It is input and/or output as the voltage on the line controls the current share. A power supply will respond to a
change in this voltage but a power supply can also change the voltage depending on the load drawn from it. On a single unit this would read 8V at 100% load. For two units sharing load then this should read 4V for perfect current sharing.
Up to 6 units can be paralleled together. Please consult your Murata sales representative if operation with more than six units in parallel is needed.
www.murata-ps.com/support
CPS_D1U4CS-W-2200-12-HxxC.A09 Page 5 of 6
D1U4CS-W-2200-12-HxxC Series
AC/DC Front End Power Supply
41.00
1.614
±0.40
Airflow Front to Back
±0.016
±0.40
±0.016
±0.016
±0.25
muRata Ps
±0.012
2.40
0.094
BARCODE
±0.30
±0.012
±0.30
8.89
0.350
101.60 ±0.50
4.000 ±0.020
12.63
0.497
13.25
0.522
10.75
0.423
±0.40
±0.010
7.62
0.300
±0.40
Airflow Back to Front
349.60
13.764
±0.016
MECHANICAL DIMENSIONS - D1U4CS-W-2200-12-HxxC
±0.25
±0.010
355.60
14.000
±0.65
±0.026
AC Input Connector: The AC input connector is standard IEC C20 20A.
Dimensions: 4.00" x 14.00"x 1.61" [101.6mm x 355.6mm x 41.0mm]
OPTIONAL ACCESSORIES
Description
Part Number
12V D1U4CS-12 output connector card
D1U4CS-12-CONC
APPLICATION NOTES
Document Number
Description
Link
ACAN-32
D1U4CS-12-CONC Output Connector Card
www.murata-ps.com/data/apnotes/acan-32.pdf
ACAN-33
D1U4CS-W Communication Protocol
www.murata-ps.com/data/apnotes/acan-33.pdf
ACAN-37
D1U4CS-x EEPROM Specification
www.murata-ps.com/data/apnotes/acan-37.pdf
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2015 Murata Power Solutions, Inc.
www.murata-ps.com/support
CPS_D1U4CS-W-2200-12-HxxC.A09 Page 6 of 6