D1U4CS-W-2200-12-HxxC Series www.murata-ps.com AC/DC Front End Power Supply PRODUCT OVERVIEW The D1U4CS-W-2200-12-HxxC is a 2200 Watt, power-factor-corrected (PFC) front-end power supply for hot-swapping redundant systems. The main output is 12V with a standby output of 5V or 3.3V. Packaged in a 1U low profile enclosure, it is designed to deliver reliable bulk power to servers, workstations, storage systems or any 12V distributed power architecture systems requiring high power density. The highly efficient electrical and thermal design with internal cooling fans supports reliable operation conditions. The D1U4CS-W-2200-12-HxxC is designed to autorecover from overtemperature fault. Status information is provided with front panel LEDs, logic signals and an I2C management interface. Four units can be packaged into an optional 19" 1U power shelf to provide up to 8.8kW of power. ORDERING GUIDE Power Output High Line AC Model Number FEATURES 2200W (220Vac), 1100W (110Vac) Output Power Certified to Climate Savers Computing InitiativeSM and 80 PLUS® Gold efficiency 12V Main Output, 3.3V or 5V Standby Output 1U height: 4.0" x 14.0" x 1.6" 24.5 Watts per cubic inch density N+1 redundancy capable, including hot plugging (up to 4 in parallel) Active Current Sharing on main output; ORing FET Overvoltage, Overcurrent, Overtemperature protection Internal cooling fans (variable speed) I²C Bus Interface, PSMI compliant RoHS compliant D1U4CS-W-2200-12-HC4C D1U4CS-W-2200-12-HC3C D1U4CS-W-2200-12-HA4C D1U4CS-W-2200-12-HA3C 2200W 2200W 2200W 2200W Power Output Low Line AC 1100W 1100W 1100W 1100W Main Output 12.12V 12.12V 12.12V 12.12V Standby Output 3.3V 3.3V 5V 5V Airflow Back to front Front to back Back to front Front to back INPUT CHARACTERISTICS Parameter Input Voltage Operating Range Input Frequency Turn-on Input Voltage Turn-off Input Voltage Maximum Input Current Inrush Current Power Factor Conditions Ramp up Ramp down Low Line AC 90Vac High Line AC 180Vac Cold start between 0-1msec Output load >90% Output load >50% Min. Typ. 90 47 81 70.5 115/230 60 Max. Units 264 63 89 78 13 13 16.5 Vac Hz Vac Arms Apk 0.95 0.95 OUTPUT VOLTAGE CHARACTERISTICS Output Voltage Optional 1U x 19" Power-Shelf 12V 5Vsb 3.3Vsb Parameter Voltage Set Point Accuracy Line and Load Regulation Ripple Voltage & Noise1 Output Current Load Capacitance Voltage Set Point Accuracy Line and Load Regulation Ripple Voltage & Noise1 Operating Range Load Capacitance Voltage Set Point Accuracy Line and Load Regulation Ripple Voltage & Noise1 Operating Range Load Capacitance Conditions Min. Typ. Max. 12.12 11.76 12.48 120 180 30000 20MHz Bandwidth 9 5 20MHz Bandwidth 4.85 5.15 50 5 10000 0 3.3 20MHz Bandwidth 3.2 0 3.4 50 6 10000 Units Vdc mV p-p A μF Vdc mV p-p A μF Vdc mV p-p A μF 1 Ripple and noise are measured with 0.1 uF of ceramic capacitance and 10 uF of tantalum capacitance on each of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial cable with 50ohm scope termination is used. For full details go to www.murata-ps.com/rohs CB Test Certificate and Test Report www.murata-ps.com/support CPS_D1U4CS-W-2200-12-HxxC.A09 Page 1 of 6 D1U4CS-W-2200-12-HxxC Series AC/DC Front End Power Supply OUTPUT CHARACTERISTICS Parameter Remote Sense Efficiency (230V) excluding fan load Output Rise Monotonicity Startup Time Transient Response Conditions Typ. Max. Units 120 mV 20% load 88 89.1 50% load 92 93.0 % 100% load 88 92.2 Overshoot less than 10% for all outputs, no voltage negative between 10% to 95% during ramp up AC ramp up 1.5 s PS_On activated 150 ms 12V Ramp 1A/μs ±360 5Vsb Ramp 1A/μs ±150 mV 3.3Vsb Ramp 1A/μs ±100 Current sharing accuracy (up to 4 in parallel) At 100% load Hot Swap Transients Holdup Time All outputs remain in regulation 100% load Min. ±7 % 5 % ms Max. 70 Units 12 ENVIRONMENTAL CHARACTERISTICS Parameter Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity Shock Sinusoidal Vibration MTBF Acoustic Safety Approvals Input Fuse Material Flammability Switching Frequency Weight Conditions Non-condensing Min. -40 Typ. D1U4CS-W-2200-12-HC4C and D1U4CSW-2200-12-HA4C models 0 50 D1U4CS-W-2200-12-HC3C and D1U4CSW-2200-12-HA3C models 0 40 10 5 90 90 Non-condensing 30G non operating 0.5G, 5 – 500 Hz operating Calculated per Bellcore at Ta=30°C 400K Demonstrated 400K ISO 7779-1999 60 CAN/CSA C22.2 No 60950-1-07, Am.1:2011 UL 60950-1-2011, 2nd Ed. UL 60950-1, 2nd Ed. IEC60950-1:2005 (2nd Ed.) w A1:2009, EN 60950-1:2006+A11:2009 +A1:2010 +A12:2011 Power Supply has internal 20A/250V fast blow fuse on the AC line input UL 94V-0 TBD 4.5lbs (2.1kg) °C % hrs hrs dB LpAm PROTECTION CHARACTERISTICS Output Voltage 12V 5Vsb 3.3Vsb Parameter Conditions Min. Overtemperature Overvoltage Overcurrent Overvoltage Overcurrent Overvoltage Overcurrent Autorestart Latching Latching Latching Brick wall, autorecovery Latching Brick wall, autorecovery 55 13.1 197 5.6 5.5 3.5 6.5 Typ. Max. Units 65 14.1 225 6.2 6.2 4.0 8.0 °C V A V A V A www.murata-ps.com/support CPS_D1U4CS-W-2200-12-HxxC.A09 Page 2 of 6 D1U4CS-W-2200-12-HxxC Series AC/DC Front End Power Supply ISOLATION CHARACTERISTICS Parameter Insulation Safety Rating / Test Voltage Isolation Grounding Conditions Min. Typ. Max. Units Input to Output - Reinforced 3000 Vrms Input to Chassis - Basic 1500 Vrms Output to Chassis Output to Output Main Output Return and Standby Output Return are connected internally. 100kΩ resistor parallel with 100nF capacitor is connected between Return and power supply chassis. Main Output Return should be connected to the System Chassis STATUS INDICATORS AND CONTROL SIGNALS Status Conditions Off Flashing Green Flashing Amber LEDs Solid Amber I2C Registers Solid Green Refer to Application Note #ACAN-33 Description No AC to all Power Supply Main Output Absent Calibration Mode; not a normal operating condition PW Fail or PWOK Low. Note: The LED will also show Solid Amber if the power module is: 1. Not correctly installed within its slot (in the host system shelf) with PS_KILL (Pin B5) correctly terminated. 2. Operated externally (as a standalone power module) and is not connected to an Output Connector Card ACAN-32 (see Optional Accessories) that correctly terminates PS_KILL (Pin B5). Power Supply Good EMISSIONS AND IMMUNITY Characteristic Input Current Harmonics Voltage Fluctuation and Flicker Conducted Emissions Radiated Emissions Standard IEC/EN 61000-3-2 IEC/EN 61000-3-3 FCC 47 CFR Part 15/CISPR 22/EN55022 FCC 47 CFR Part 15/CISPR 22/EN55022 ESD Immunity IEC/EN 61000-4-2 Radiated Field Immunity Electrical Fast Transients/Burst Immunity Surge Immunity RF Conducted Immunity Magnetic Field Immunity Voltage dips, interruptions IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 IEC/EN 61000-4-11 Compliance Complies Complies Class A, 6dB margin Class A, 6dB margin 4kV contact discharge 8kV operational air discharge 15kV non-operational air discharge Complies Complies 1kV/2kV, Performance Criteria A 3 Vac, 80% AM, 1kHz, Performance Criteria A 3 A/m Complies www.murata-ps.com/support CPS_D1U4CS-W-2200-12-HxxC.A09 Page 3 of 6 D1U4CS-W-2200-12-HxxC Series AC/DC Front End Power Supply OUTPUT CONNECTOR AND SIGNAL SPECIFICATION DC and Signal Connector: FCI PowerBlade # 51732-048LF P1 VOUT P2 VOUT P3 VOUT P4 VOUT P5 VOUT P6 P7 VRTN VRTN P8 VRTN P9 VRTN P10 x1 x2 x3 x4 x5 x6 AC_OK/H PW_OK/H Vsb RETURN Vsb RETURN Vsb +OUT Vsb +OUT D SPARE SMB/ Alert Vsb RETURN Vsb RETURN Vsb +OUT Vsb +OUT C I_SHARE I2C ADR0 I2C ADR1 I2C ADR2 PS_KILL PS_ PRESENT B SENSE + SENSE - I2C DATA I2C CLOCK SPARE PS_ON/L A VRTN mate-last pins High Level Low Level Pin Assignment Signal Name Description I Max P1 to P5 P6 to P10 VOUT VRTN Main output voltage Main output voltage, return A1 Sense + VOUT remote sense, positive node input, connected to the +ve load point A2 Sense - VOUT remote sense, negative node input, connected to the -ve load point C5, C6, D5, D6 C3, C4, D3, D4 B1 Vsb Vsb Return I_Share Standby voltage output Standby voltage, return, tied internally to Output Return Active load sharing bus 0 – 8V -4 mA / +5 mA D1 AC_OK/H Input AC Voltage “OK” signal output (Internal pull up is 10kΩ to Vsb) >2.1V <0.8V +4 mA -2 mA D2 PW_OK/H Internal pull up of 10KΩ to Vsb >2.1V <0.8V +4 mA -2 mA C2 SMB/Alert SMB/Alert signal output (open collector) B5 PS_Kill Floating pin will turn off P/S (shorter pin, last-make and first-break contact for hot plugging). This signal overrides PS-On in disabling the Main Output >2.1V (open) <0.8V (active, PS:On) N/A B6 PS_Present Internally tied to Vsb Return 0V A6 PS_On/L Internal 3.3KΩ pull-up to Vsb (accepts open collector/ drain drive). This signal to be pulled low to turn-on power supply A3 A4 I2C Data I2C Clock I2C serial data bus; internal 4.64KΩ pull-up to Vsb I2C serial clock bus; internal 4.64KΩ pull-up to Vsb B2 I2C Adr0 Address input 0, internal 10KΩ pull-up to Vsb >2.1V <0.8V ±1 mA B3 I2C Adr1 Address input 1, internal 10KΩ pull-up to Vsb >2.1V <0.8V ±1 mA B4 I2C Adr2 Address input 2, internal 10KΩ pull-up to Vsb >2.1V <0.8V ±1 mA >2.1V (open, or 3.3V) <0.8V (active, PS:On) D1U4CS MATING CONNECTORS 12V D1U4 mating connector Solder 1 Press Fit Straight Murata-PS FCI N/A 51742-11002400AALF Right Angle 4321-01454-0 51762-11002400ABLF Straight N/A N/A Right Angle N/A N/A 1 Solder connector recommended for board thickness of <0.090 www.murata-ps.com/support CPS_D1U4CS-W-2200-12-HxxC.A09 Page 4 of 6 D1U4CS-W-2200-12-HxxC Series AC/DC Front End Power Supply WIRING DIAGRAM FOR OUTPUT Dotted lines show optional remote sense connections. Optional remote sense lines can be attached to a load that is a distance away from the power supply to improve regulation at the load. Sense + (Main Output Remote Sense) A1 P1-P5 Sense + (Main Output Remote Sense) VOUT VOUT P1-P5 A1 D1U4CS 12V load D1U4CS P6-P10 VRTN VRTN P6-P10 A2 Sense – Sense – A2 B1 I_Share I_Share B1 C5,C6,D5,D6 A6 Vsb Vsb PS_On PS_On Close switch (or FET, BJT, or wire) to turn on +12V OUT C3,C4,D3,D4 B5 Vsb Return C5,C6,D5,D6 A6 Vsb logic circuitry Vsb Return C3,C4,D3,D4 PS_Kill PS_Kill B5 CURRENT SHARING NOTES 12V Output: Current sharing is achieved using the active current share method. (See wiring diagram for connection details.) The total combined load must be below 2200W at startup. Current sharing can be achieved with or without remote sense connected to the common load. VSB outputs can be tied together for redundancy but total combined output power must not exceed 25W. The VSB output has internal ORing MOSFET for additional redundancy / internal short protection. The current share pin B1 is a connection between the two units. It is input and/or output as the voltage on the line controls the current share. A power supply will respond to a change in this voltage but a power supply can also change the voltage depending on the load drawn from it. On a single unit this would read 8V at 100% load. For two units sharing load then this should read 4V for perfect current sharing. Up to 6 units can be paralleled together. Please consult your Murata sales representative if operation with more than six units in parallel is needed. www.murata-ps.com/support CPS_D1U4CS-W-2200-12-HxxC.A09 Page 5 of 6 D1U4CS-W-2200-12-HxxC Series AC/DC Front End Power Supply 41.00 1.614 ±0.40 Airflow Front to Back ±0.016 ±0.40 ±0.016 ±0.016 ±0.25 muRata Ps ±0.012 2.40 0.094 BARCODE ±0.30 ±0.012 ±0.30 8.89 0.350 101.60 ±0.50 4.000 ±0.020 12.63 0.497 13.25 0.522 10.75 0.423 ±0.40 ±0.010 7.62 0.300 ±0.40 Airflow Back to Front 349.60 13.764 ±0.016 MECHANICAL DIMENSIONS - D1U4CS-W-2200-12-HxxC ±0.25 ±0.010 355.60 14.000 ±0.65 ±0.026 AC Input Connector: The AC input connector is standard IEC C20 20A. Dimensions: 4.00" x 14.00"x 1.61" [101.6mm x 355.6mm x 41.0mm] OPTIONAL ACCESSORIES Description Part Number 12V D1U4CS-12 output connector card D1U4CS-12-CONC APPLICATION NOTES Document Number Description Link ACAN-32 D1U4CS-12-CONC Output Connector Card www.murata-ps.com/data/apnotes/acan-32.pdf ACAN-33 D1U4CS-W Communication Protocol www.murata-ps.com/data/apnotes/acan-33.pdf ACAN-37 D1U4CS-x EEPROM Specification www.murata-ps.com/data/apnotes/acan-37.pdf Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2015 Murata Power Solutions, Inc. www.murata-ps.com/support CPS_D1U4CS-W-2200-12-HxxC.A09 Page 6 of 6