603 SERIES EMC PANEL INDICATOR LED FEATURES • • • • • • • Marl Part Number LED Colour 603-301-04-58 603-325-04-58 603-324-04-58 603-934-04-58 603-998-04-58 603-303-04-58 603-309-04-58 603-312-04-58 Red Yellow Green Blue Cool White Red (Standard Intensity) Yellow (Standard Intensity) Green (Standard Intensity) Typical Emission Colours Cool White LED X 0.296 Y 0.276 0.283 0.305 EMC mesh under lens Ø5.0mm mounting Bright nickel plated brass housing Sealed to IP67 - weatherproof Colour diffused lens Internal potting Range of LED colour options Typical Voltage DC Vf 1.85 2.0 3.2 3.2 3.2 2.0 2.1 2.2 Vdc 0.330 0.360 BENEFITS Typical Current If 20 20 20 20 20 20 20 20 mA • • • • • • • • • Typical LED Luminous Intensity 900 2800 36100 6550 12900 131 43 131 mcd Protects against EMI/RFI Standard industrial mounting size Suitable for harsh environments Suitable for external applications Wide viewing angle Suitable for high vibration applications Suitable for status panel indication Outstanding reliability Vandal resistant Typical LED Wavelength λp 660 590 525 465 See Below 627 590 565 nm Operating Temp Topr * -40 to +85 -40 to +85 -30 to +85 -30 to +85 -30 to +85 -40 to +85 -40 to +85 -40 to +85 °C Storage Temp Tstg -40 to +85 -40 to +85 -40 to +100 -40 to +100 -40 to +100 -40 to +85 -40 to +85 -40 to +85 °C 0.330 0.318 NOTES Intensities (lv) and colour shades of white (X-Y co-ordinates) may vary between LEDs within a batch. Additional LED Colours, Voltage Options and Flying Lead lengths available for semicustom projects. Please contact our Sales Team. All LED components are supplied in anti-static packaging. * Characteristics at Ta = 25°C. For operating temperature derating graphs, please refer to sheet 2. To order please contact us on +44 (0) 1229 582 430 F +44 (0) 1229 585 155 | E [email protected] | www.leds.co.uk marlleds marlinternationallimited company/marl-international-limited Q 05480 DSN 603EMC Version DS015/2016. Page 1 of 2 603 SERIES EMC PANEL INDICATOR LED TECHNICAL CHARACTERISTICS Series 603 Max. Power Dissipation Max. Reverse Voltage Panel Cutout Nut Mounting Torque Min. Mounting Centres Min. - Max. Panel Thickness mW Vdc mm Nm mm mm 425 5 5.0 0.35 10.0 1.5 - 8.0 TECHNICAL DRAWING Weight (g): 1.75 Dimensions in mm (typical). Not to scale. Mounting hole to be clean and burr free. Anode termination denoted by red indicator. 1.4 5 PUSH ON CONNECTOR + 0.1 0 11.8 5.1 7.9 0.45 Typ. 15.2 2.5 909-000-00 is gold plated, 910-000-00 is tim plated - for use with 603 series lamps. Dimensions in mm (typical). Not to scale. 2 12.0 Min. 1.2 Typ. Mounting hole DE-RATING GRAPHS Blue / Green High Intensity LED 40 30 20 10 40 30 20 10 0 20 40 60 80 0 100 40 30 20 10 0 20 40 60 80 60 80 Body Nut Panel Seal Fresnel Lens 0 100 40 30 20 0 20 40 60 80 100 Ambient Temperature Ta (°C) 50 Green Standard Intensity LED 50 40 30 20 10 0 Ambient Temperature Ta (°C) MATERIALS 20 0 100 10 40 30 8.5 Yellow Standard Intensity LED Forward Current If (mA) Forward Current If (mA) Red Standard Intensity LED 20 40 Ambient Temperature Ta (°C) 50 0 50 10 8.5 Ambient Temperature Ta (°C) 0 Cool White High Intensity LED Forward Current If (mA) 0 50 Forward Current If (mA) 50 Forward Current If (mA) Forward Current If (mA) Red / Yellow High Intensity LED 20 40 60 80 100 Ambient Temperature Ta (°C) Encapsulation Lock Washer EMC Mesh Termination Bright Nickel Plated Brass Bright Nickel Plated Brass Viton Polycarbonate 0 0 20 40 60 80 100 Ambient Temperature Ta (°C) Black Polyurethane Beryllium Copper Stainless Steel LED Leads DESIGN CONSIDERATIONS Electro-Static Discharge (ESD) Build up of electro-static discharge occurs in many situations involving people moving and handling products.The range of possible situations is very diverse but voltage levels as high as several thousand volts can and do arise in many individual situations. When an operator charged up to these levels handles a static sensitive device, there is a very probable likelihood that the device will be irreversibly damaged. It is essential that precautions are taken at all stages during manufacture and assembly of these products. Although LEDs were never considered to be static sensitive devices, changes in manufacturing technology and materials used to produce higher intensity products over a large range of the wavelength spectrum have changed this. Marl has an approved system of ESD control from goods in, through production and into final packing and despatch. Marl recommend all users of LED based products follow the guidelines of BS 100015. Voltage, Current and Temperature The forward voltage / current value of an LED is dependent upon the ambient temperature of the environment in which To order please contact us on +44 (0) 1229 582 430 F +44 (0) 1229 585 155 | E [email protected] | www.leds.co.uk marlleds marlinternationallimited company/marl-international-limited it is operated. Therefore, care must be taken to operate the LED at the correct voltage / current values, depending upon the ambient temperature. Marl should be contacted if the device is to be operated outside the temperature range specified. Marl accept no liability for any product that is operated outside the stated voltage or temperature range. Q 05480 DSN 603EMC Version DS015/2016. Page 2 of 2