Bolt-in Rear Terminals - 10-BPF Series - For General Purpose Applications

Power Entry Modules
Bolt-in
Rear Terminals
For General Purpose Applications
10-BPF Series
Features
■
■
■
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Operating temperature: -25°C to +70°C
Compact configuration
Circuit Diagram
CX
CY
Applications
■
■
■
■
CY
L1
1
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CX
CY
L1
CX
CY
2
CX
CX
L1
CY
CY
3
Specifications
Model
10-BPF-001-5-A
Rated
Rated
Voltage
Current
(@ 50/60Hz)
Leakage
Current
(Max.)
Inductance Circuit
(L1)
Diagram
1
1.5mH
3A
120/250VAC
0.50mA
10-BPF-006-5-A
6A
4700pF
10A
10-BPF-010-5-D
Temperature
Rise
(Max.)
C
A
C
2
B
A
0.5mH
1
3300pF & 0.01uF
1.5mH
2
B
3300pF
0.01uF
0.5mH
1
A
3300pF & 0.01uF
3300pF & 0.01uF
1.5mH
3
B
3300pF
3300pF & 0.01uF
10-BPF-006-5-D
0.01uF
Figure
A
3.0mH
3300pF
10-BPF-003-5-C
10-BPF-010-5-A
CX
2200pF
10-BPF-003-5-A
10-BPF-006-5-C
Capacitance
1A
10-BPF-001-5-C
10-BPF-003-5-D
CY
30°C
C
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF22
Figure B
Power Entry Modules
Bolt-in
Rear Terminals
For General Purpose Applications
10-BPF Series
M3 (2X)
1.6
(40)
M3 (2X)
2.0 (52)
2.0 (52)
1.1 (28.5)
+.01 -0.0
1.6 (40)
±.007
Figure A
1.4 (37)
2.8 (72)
Figure C
.80 (20.5)
+.01 -0.0
1.25 (32)
1.4 (3.5) (2X)
2.3 (62)
1.9 1.6 1.2
(50) (40) (30)
.13 (3.5 (2X)
1.1 (28)
.62 (16)
.82 (21)
.25
(6.5)
1.8 (46)
1.5 (37.5)
1.6 (40)
2.0 (51)
1.9 (50)
1.1 (27)
.07 (2)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
80
70
70
Insertion Loss (dB)
Insertion Loss (dB)
10-BPF-001-5-A
10-BPF-001-5-C
50
40
10-BPF-003-5-A
30
10-BPF-003-5-C
20
60
10-BPF-001-5-A
50
10-BPF-001-5-C
40
30
10-BPF-003-5-A
20
10-BPF-003-5-C
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
5
10
50
80
10-BPF-006-5-D
70
70
Insertion Loss (dB)
60
10-BPF-006-5-A
10-BPF-006-5-C
40
30
20
10-BPF-006-5-D
60
50
40
10-BPF-010-5-A
1
10-BPF-010-5-D
30
10-BPF-006-5-A
20
10-BPF-006-5-C
10-BPF-010-5-A
10
10
0
0.1
20
10-BPF-006;-010
10-BPF-006;-010
80
Insertion Loss (dB)
2
Frequency (MHz)
Frequency (MHz)
50
50Ω
Level
Meter
50Ω
10-BPF-001;-003
10-BPF-001;-003
80
60
50Ω
10-BPF-010-5-D
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF23