DT10S/D Series DC/DC CONVERTER 10W, Reinforced Insulation, Medical Safety FEATURES Efficiency up to 82% I/O Isolation 4200VAC with Reinforced Insulation, rated for 300VAC Working Voltage Medical Safety to UL/CSA/EN/IEC 60601-1 3rd Edition 2 MOOP rated Wide 2:1 Input Voltage Range Fully regulated Output Voltage Low Leakage Current Operating Temp. Range –40°C to +75 °C Input Filter meets EN 55022,class A and FCC, level A Overload Protection 2”x 1” Plastic Package 3 Years Product Warranty The DT10S/D series is a new range of high performance DC/DC converter modules with a reinforced insulation system .The I/Oisolation voltage is specified for 4200VACrms.The product comes in a compact 2”x1” industry standard package. All 15 models features wide 2:1 input voltage range and fully regulated output voltage.The DT10S/D DC/DC converters offer an economical solution for demanding applications in industrial and medical instrumentation requesting a certified supplementary or reinforced insulation system to comply with industrial or latest medical safety standards. Model List Model Input Output Number Voltage Voltage (Range) VDC DT10S1205A DT10S12051A DT10S1212A 12 Output Current Input Current Ripple Max. @Max. Load @No Load VDC mA mA(typ.) 5 1600 877 5.1 1600 907 12 835 1044 ±12 ±417 1042 ±15 ±333 1028 DT10S2405A 5 2000 541 DT10S24051A 5.1 2000 559 12 835 516 DT10D1212A (9 ~ 18) DT10D1215A DT10S2412A DT10D2412A 24 (18 ~ 36) ±12 ±417 516 DT10D2415A ±15 ±333 508 DT10S4805A 5 2000 271 5.1 2000 280 12 835 258 ±12 ±417 258 ±15 ±333 254 DT10S48051A DT10S4812A DT10D4812A DT10D4815A 48 (36 ~ 75) Reflected Max. capacitive mA (typ.) Load Current mA(typ.) 100 μF 470 220# 1000 20 50 470 220# 1000 10 25 (typ.) @Max. Load 1000 30 Efficiency 470 220# % 76 75 80 80 81 77 76 81 81 82 77 76 81 81 82 # For each output DS_DT10S/D_12092015 E-mail: [email protected] http://www.deltaww.com/dcdc P1 Input Specifications Parameter Input Surge Voltage (1 sec. max.) Start-Up Threshold Voltage Under Voltage Shutdown Short Circuit Input Power Internal Power Dissipation Conducted EMI Model 12V Input Models 24V Input Models 48V Input Models Min. -0.7 -0.7 -0.7 Typ. Max. Unit 25 --50 --100 --7 8 9 13 15 18 VDC 30 33 36 ----8.5 ----16 ----34 ----3000 mW ----4000 mW Compliance to EN 55022,class A and FCC part 15,class A 12V Input Models 24V Input Models 48V Input Models 12V Input Models 24V Input Models 48V Input Models All Models Output Specifications Conditions Min. Typ. Max. Unit Output Voltage Setting Accuracy Parameter At 50% Load and Nominal Vin --- --- ±1.0 %Vnom. Output Voltage Balance Dual Output, Balanced Loads --- ±0.5 ±2.0 % Vin=Min. to Max. --- ±0.3 ±0.5 % Io=15% to 100% --- ±0.5 ±1.0 % Io=5% to 100% --- ±0.6 ±1.2 % 5V & 5.1V Output Models --- 75 100 mV P-P --- 100 150 mV P-P Line Regulation Load Regulation Ripple & Noise (20MHz) Other Output Models Min.Load No minimum Load Requirement Over Load Protection Transient Recovery Time Transient Response Deviation 25% Load Step Change Temperature Coefficient 120 150 --- % --- 300 600 μsec --- ±3 ±5 % --- ±0.02 ±0.05 %/℃ Short Circuit Protection Continuous Isolation, Safety Standards Parameter Conditions Min. Typ. Max. Unit 60 Seconds 4200 --- --- VACrms Flash tested for 1 Second 6000 --- --- VPK 240VAC, 60Hz --- --- 10 μA I/O Isolation Resistance 500 VDC 10 --- --- GΩ I/O Isolation Capacitance 100KHz, 1V --60 80 cUL/UL60950-1, CSA C22.2 No. 60950-1-03 UL60601-1,CSA C22.2 No.601-1, IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition, 2 MOOP IEC60950-1 CB report, cUL/UL 60950-1 certificate UL60601-1 UL certificate pF I/O Isolation Voltage (reinforced) I/O Isolation Test Voltage Leakage Current Safety Standards Approvals(Pending) General Specifications Parameter Conditions Switching Frequency MTBF(calculated) MIL-HDBK-217F@25℃, Ground Benign Min. Typ. Max. Unit 120 150 180 KHz 1,000,000 --- --- Hours Input Fuse 12V Input Models 24V Input Models 48V Input Models 3000mA Slow-Blow Type 1500mA Slow-Blow Type 750mA Slow-Blow Type DS_DT10S/D_12092015 E-mail: [email protected] http://www.deltaww.com/dcdc P2 Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Case Temperature Storage Temperature Range Humidity (non condensing) Altitude Cooling Lead Temperature (1.5mm from case for 10Sec.) Conditions Natural Convection Min. -40 Max. +75 --+95 -50 +125 --95 --4000 Free-Air convection --260 Unit ℃ ℃ ℃ % rel. H m ℃ Power Derating Curve 100 Output Power (%) 80 Natural Convection 20LFM 60 40 20 0 ~ -40 0 20 40 60 80 100 110 Ambient Temperature C Notes 1 2 3 4 5 6 7 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. Ripple & Noise measurement bandwidth is 0-20MHz. All DC/DC converters should be externally fused at the front end for protection. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. DS_DT10S/D_12092015 E-mail: [email protected] http://www.deltaww.com/dcdc P3 Mechancial Drawing Mechanical Dimensions Pin Connections 5.08 [0.20] 5.08 [0.20] Bottom View 5 4 Pin Single Output Dual Output 1 +Vin +Vin 2 -Vin -Vin 3 +Vout +Vout 4 No Pin Common 5 -Vout -Vout 50.8 [2.00] 1.00 [ 0.04] 1 45.72 [1.80] 2 12.0 [0.47] ►All dimensions in mm (inches) 3 ►Tolerance: X.X±0.25 (X.XX±0.01) 10.16 [0.40] 10.16 [0.40] 2.54 [0.10] X.XX±0.13 ( X.XXX±0.005) ►Pin diameter 1.0 ±0.05 (0.04±0.002) 25.4 [1.00] Physical Outline Case Size : 50.8x25.4x12.0mm (2.0x1.0x0.47 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 24.5g DS_DT10S/D_12092015 E-mail: [email protected] http://www.deltaww.com/dcdc P4 Part Numbering System D T 10 S 12 05 A Form factor Family series Watt Number of Outputs Input Voltage Output Voltage Option Code D - DIP P - SIP S - SMD A~Z 10 - 10W 12 - 12V 24 - 24V 48 - 48V 05 - 5V 051 - 5.1V 12 - 12V 15 - 15V A - Std. Functions S - Single D - Dual WARRANTY Delta offers a three(3) years limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. DS_DT10S/D_12092015 E-mail: [email protected] http://www.deltaww.com/dcdc P5