T520 Catalog

KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Overview
The KEMET Organic Capacitor (KO-CAP) is a solid electrolytic
capacitor with a conductive polymer cathode capable of
delivering very low ESR and improved capacitance retention at
high frequencies. KO-CAP combines the low ESR of multilayer
ceramic, the high capacitance of aluminum electrolytic and the
volumetric efficiency of tantalum into a single surface mount
package. Unlike liquid electrolyte-based capacitors, KO-CAP has
a very long operational life and high ripple current capabilities.
The T520 Low ESR Polymer Electrolytic provides the widest range
of voltage, capacitance and case size options in the KO-CAP
family. Suitable for general purpose DC applications up to 12.8
volts, the T520 is ideal for DC-to-DC converters, bulk decoupling
and hold-up.
Benefits
•
•
•
•
•
•
•
Extremely low ESR
Volumetrically efficient
High frequency capacitance retention
100% accelerated steady state aging
100% surge current tested
EIA standard case sizes
Halogen-Free Epoxy/RoHS Compliant
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
Applications
Typical applications include DC/DC converters, notebook PCs, portable electronics, telecommunications (mobile phone and base
station), displays, SSD, HDD and USB.
Environmental Compliance
RoHS Compliant (6/6) according to Directive 2002/95/EC when ordered with 100% Sn , Ni-Pd-Au or Non-magnetic 100% Sn solder.
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
1
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
K-SIM
For a detailed analysis of specific part numbers, please visit ksim.kemet.com to access KEMET’s K-SIM software. KEMET K-SIM is
designed to simulate behavior of components with respect to frequency, ambient temperature, and DC bias levels. Ordering Information
Ordering Information
T
520
V
157
Capacitor
Class
Series
Case
Size
Capacitance
Code (pF)
T=
Tantalum
520 =
Polymer
A, B,
C, D,
H, L,
M, Q,
T, U,
V, W,
X, Y
First two digits
represent
significant
figures. Third digit
specifies number
of zeros.
M
006
A
Capacitance Rated Voltage Failure Rate/
Tolerance
(VDC)
Design
M = ±20%
2R5 = 2.5
003 = 3
004 = 4
006 = 6.3
008 = 8
010 = 10
011 = 11
12R = 12.5
016 = 16
020 = 20
025 = 25
A = N/A
T
E045
Termination Finish
ESR Code
T = 100% Matte Tin
(Sn) plated
H = Tin/Lead (SnPb)
solder coated (5% Pb
minimum)
P* = Ni-Pd-Au plated
N = Non-magnetic
100% Tin (Sn)
M = Non-magnetic
(SnPb)
E = ESR
Last three digits
specify ESR in
mΩ. (045 = 45
mΩ)
Packaging
(C-Spec)
Blank = 7"
Reel
7280 = 13"
Reel
* P termination only available on select part numbers. Contact KEMET for details.
Performance Characteristics
Item
Performance Characteristics
Operating Temperature
Rated Capacitance Range
Capacitance Tolerance
Rated Voltage Range
DF (120 Hz)
ESR (100 kHz)
Leakage Current
-55°C to 105°C
10 – 1,500 µF at 120 Hz/25°C
M Tolerance (20%)
2.5 – 25 V
≤ 10%
Refer to Part Number Electrical Specification Table
≤ 0.1 CV (μA) at rated voltage after 5 minutes
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
2
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Qualification
Test
Condition
Characteristics
Δ C/C
Endurance
Storage Life
Humidity
Temperature Stability
105°C at rated voltage, 2,000 hours
105°C at 0 volts, 2,000 hours
60°C, 90% RH, 500 hours, No Load
Extreme temperature exposure at a
succession of continuous steps at +25ºC,
-55ºC, +25ºC, +85ºC, +105ºC, +25ºC
Δ C/C
Within -20%/+10% of initial value
DF
Within initial limits
DCL
Within 1.25 x initial limit
ESR
Within 2.0 x initial limit
Δ C/C
Within -20%/+10% of initial value
DF
Within initial limits
DCL
Within 1.25 x initial limit
ESR
Within 2.0 x initial limit
Δ C/C
Within -5%/+35% of initial value
DF
Within initial limits
DCL
Within 5.0 x initial limit
ESR
Within 2.0 x initial limit
+25°C
-55°C
+85°C
+105°C
IL*
±20%
±20%
±30%
DF
IL
IL
1.2 x IL
1.5 x IL
DCL
IL
N/A
10 x IL
10 x IL
Δ C/C
Surge Voltage
Mechanical Shock/Vibration
105°C, 1.32 x rated voltage, 1,000 cycles
MIL–STD–202, Method 213, Condition I, 100 G peak.
MIL–STD–202, Method 204, Condition D, 10 Hz to 2,000 Hz,
20 G peak
Within -20%/+10% of initial value
DF
Within initial limits
DCL
Within initial limits
ESR
Within initial limits
Δ C/C
Within ±10% of initial value
DF
Within initial limits
DCL
Within initial limits
*IL = Initial limit
Electrical Characteristics
Capacitance vs. Frequency
ESR vs. Frequency
100
T520B157M006ATE035_Imp
1000
T520V337M006ATE015_Imp
10
T520D337M006ATE009_Imp
T520B157M006ATE035_ESR
T520C227M006ATE025_ESR
T520V337M006ATE015_ESR
1
T520D337M006ATE009_ESR
0.1
Capacitance (µF)
Impedance,ESR (Ohms)
T520C227M006ATE025_Imp
100
10
T520B157M006ATE035
T520C227M006ATE025
T520V337M006ATE015
T520D337M006ATE009
0.01
0.001
100
1
1,000
10,000
100,000
Frequency (Hz)
1,000,000
10,000,000
100
1,000
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
10,000
100,000
Frequency (Hz)
1,000,000
10,000,000
T2015_T520 • 4/4/2016
3
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Dimensions – Millimeters (Inches)
Metric will govern
CATHODE (-) END VIEW
SIDE VIEW
ANODE (+) END VIEW
BOTTOM VIEW
A
B
W
B
Glue pad
shape/design at
KEMET's option
H
X
T
S
S
Case Size
KEMET
EIA
A
3216–18
B
3528–21
C
6032–28
D
7343–31
H
7360–20
L
6032–19
M
3528–15
Q
7343-12
T
3528–12
U
6032–15
V
7343–19
W
7343–15
X
7343–43
Y
7343–40
P
Termination cutout
at KEMET's option,
either end
R
L
Total
Weight
Component Dimensions
L
W
H
3.2 ±0.2
(0.126 ±0.008)
3.5 ±0.2
(0.138 ±0.008)
6.0 ±0.3
(0.236 ±0.012)
7.3 ±0.3
(0.287 ±0.012)
7.3 ±0.3
(0.287 ±0.012)
6.0 ±0.3
(0.236 ±0.012)
3.5 ±0.2
(0.138 ±0.008)
7.3 ±0.3
(0.287 ±0.012)
3.5 ±0.2
(0.138 ±0.008)
6.0 ±0.3
(0.236 ±0.012)
7.3 ±0.3
(0.287 ±0.012)
7.3 ±0.3
(0.287 ±0.012)
7.3 ±0.3
(0.287 ±0.012)
7.3 ±0.3
(0.287 ±0.012)
1.6 ±0.2
(0.063 ±0.008)
2.8 ±0.2
(0.110 ±0.008)
3.2 ±0.3
(0.126 ±0.012)
4.3 ±0.3
(0.169 ±0.012)
6.0±0.3
(0.236 ±0.012)
3.2 ±0.2
(0.110 ±0.008)
2.8 ±0.2
(0.110 ±0.008)
4.3 ±0.3
(0.169 ±0.012)
2.8 ±0.2
(0.110 ±0.008)
3.2 ±0.2
(0.110 ±0.008)
4.3 ±0.3
(0.169 ±0.012)
4.3 ±0.3
(0.169 ±0.012)
4.3 ±0.3
(0.169 ±0.012)
4.3 ±0.3
(0.169 ±0.012)
1.6 ±0.2
(0.063 ±0.008)
1.9 ± 0.1
(0.075 ±0.004)
2.5 ±0.3
(0.098 ±0.012)
2.8 ±0.3
(0.110 ±0.012)
1.9 ±0.1
(0.075 ±0.004)
1.8 ±0.1
(0.071 ±0.004)
1.4 ±0.1
(0.055 ±0.004)
1.1 ±0.1
(0.043 ±0.004)
1.1 ±0.1
(0.043 ±0.004)
1.4 ±0.1
(0.055 ±0.004)
1.8 ±0.1
(0.071 ±0.004)
1.4 ±0.1
(0.055 ±0.004)
4.0 ±0.3
(0.157 ±0.012)
3.8 ±0.2
(0.150 ±0.008)
F ±0.1
S ±0.3 B ±0.15 (Ref)
±(0.004) ±(0.012)
±0.006
1.2 (0.047) 0.80 (0.032)
N/A
2.2 (0.087) 0.80 (0.032)
0.4 (0.016)
2.2 (0.087) 1.30 (0.051)
0.5 (0.020)
2.4 (0.094) 1.30 (0.051)
0.5 (0.020)
F
X (Ref)
P (Ref)
0.10 ±0.10
N/A
(0.004 ±0.004)
0.10 ±0.10
0.5 (0.020)
(0.004 ±0.004)
0.10 ±0.10
0.9 (0.035)
(0.004 ±0.004)
0.10 ±0.10
0.9 (0.035)
(0.004 ±0.004)
0.10 ±0.10
N/A
(0.004 ±0.004)
4.1 (0.161)
1.3 (0.051)
N/A
2.2 (0.087)
1.3 (0.051)
N/A
0.05 (0.002)
2.2 (0.087)
0.8 (0.031)
N/A
2.4 (0.094)
1.3 (0.051)
R (Ref)
N/A
T (Ref)
A
(Minimum)
0.13 (0.005) 1.2 (0.047)
(mg)
53.16
1.0 (0.039) 0.13 (0.005)
1.9 (0.075)
94.85
1.0 (0.039) 0.13 (0.005)
2.9 (0.114)
184.14
1.0 (0.039) 0.13 (0.005)
3.6 (0.142)
434.83
N/A
0.13 (0.005)
3.3 (0.130)
384.64
N/A
N/A
0.13 (0.005)
2.5(0.098)
186.68
0.05 (0.002)
N/A
N/A
0.13 (0.005)
1.1 (0.043)
97.99
N/A
0.05 (0.002)
N/A
N/A
0.13 (0.005)
3.8 (0.150)
170.35
2.2 (0.087) 0.80 (0.032)
N/A
0.05 (0.002)
N/A
N/A
0.13 (0.005) 1.9 (0.075)
54.84
2.2 (0.087) 1.30 (0.051)
N/A
0.05 (0.002)
N/A
N/A
0.13 (0.005)
2.9 (0.114)
117.36
2.4 (0.094) 1.30 (0.051)
N/A
0.05 (0.002)
N/A
N/A
0.13 (0.005)
3.6 (0.142)
274.30
2.4 (0.094) 1.30 (0.051)
N/A
0.05 (0.002)
N/A
N/A
0.13 (0.005)
3.6 (0.142)
222.95
1.0 (0.039) 0.13 (0.005)
3.6 (0.142)
553.96
1.0 (0.039) 0.13 (0.005)
3.8 (0.150)
493.99
2.4 (0.094) 1.30 (0.051)
0.5 (0.020)
2.4 (0.094)
0.5 (0.020)
1.3 (.051)
0.10 ±0.10
1.7 (0.067)
(0.004 ±0.004)
0.10 ±0.10
1.7 (0.067)
(0.004 ±0.004)
Notes: (Ref) – Dimensions provided for reference only. For low profile cases, no dimensions are provided for B, P or R because these cases do not have a bevel or a notch.
These weights are provided as reference. If exact weights are needed, please contact your KEMET Sales Representative
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
4
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
mΩ at 25°C
100 kHz
Maximum
40
90
70
80
40
70
25
35
40
70
55
25
35
15
18
21
25
30
35
55
70
70
55
25
45
25
6
7
9
12
15
25
45
7
40
9
12
15
18
35
45
70
15
18
25
45
9
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
2200
1100
1300
1200
1600
1200
2300
1900
1800
1300
1600
1732
1500
2900
2700
2500
2300
2100
1900
1500
1300
1225
1600
2600
1900
2700
5600
5200
4600
3900
3500
2700
2000
5700
2400
3073
2700
2900
2700
1900
1700
1300
3300
3000
2600
1900
4100
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
10
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
10
8
8
8
10
10
10
10
10
10
10
10
10
10
8
8
8
8
8
8
8
8
8
8
8
8
Maximum
Operating
Temp
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
2
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
470
47
68
68
100
100
100
100
100
100
150
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
330
330
330
330
330
330
330
330
330
330
330
330
V/7343-19
A/3216-18
A/3216-18
A/3216-18
T/3528-12
T/3528-12
B/3528-21
B/3528-21
B/3528-21
B/3528-21
U/6032-15
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
T/3528-12
U/6032-15
C/6032-28
C/6032-28
W/7343-15
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
D/7343-31
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
C/6032-28
C/6032-28
C/6032-28
C/6032-28
L/6032-19
T520V477M002A(1)E040
T520A476M2R5A(1)E090
T520A686M2R5A(1)E070
T520A686M2R5A(1)E080
T520T107M2R5A(1)E040
T520T107M2R5A(1)E070
T520B107M2R5A(1)E025
T520B107M2R5A(1)E035
T520B107M2R5A(1)E040
T520B107M2R5A(1)E070
T520U157M2R5A(1)E055
T520A227M2R5A(1)E025
T520A227M2R5A(1)E035
T520B227M2R5A(1)E015
T520B227M2R5A(1)E018
T520B227M2R5A(1)E021
T520B227M2R5A(1)E025
T520B227M2R5A(1)E030
T520B227M2R5A(1)E035
T520B227M2R5A(1)E055
T520B227M2R5A(1)E070
T520T227M2R5A(1)E070
T520U227M2R5A(1)E055
T520C227M2R5A(1)E025
T520C227M2R5A(1)E045
T520W227M2R5A(1)E025
T520V227M2R5A(1)E006
T520V227M2R5A(1)E007
T520V227M2R5A(1)E009
T520V227M2R5A(1)E012
T520V227M2R5A(1)E015
T520V227M2R5A(1)E025
T520V227M2R5A(1)E045
T520D227M2R5A(1)E007
T520D227M2R5A(1)E040
T520B337M2R5A(1)E009
T520B337M2R5A(1)E012
T520B337M2R5A(1)E015
T520B337M2R5A(1)E018
T520B337M2R5A(1)E035
T520B337M2R5A(1)E045
T520B337M2R5A(1)E070
T520C337M2R5A(1)E015
T520C337M2R5A(1)E018
T520C337M2R5A(1)E025
T520C337M2R5A(1)E045
T520L337M2R5A(1)E009
µA at 25°C
Maximum/5
Minutes
94
12
17
17
25
25
25
25
25
25
38
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
83
83
83
83
83
83
83
83
83
83
83
83
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
5
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
mΩ at 25°C
100 kHz
Maximum
12
25
15
25
40
6
7
9
12
15
18
25
40
6
7
6
7
9
12
15
18
25
45
6
7
9
10
15
40
15
25
4.5
6
7
9
10
15
30
10
15
25
10
15
25
35
40
70
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
3500
2400
3500
2700
2100
5600
5200
4600
3900
3500
3200
2700
2200
6100
5700
5600
5200
4600
3900
3500
3200
2600
1900
6100
5700
5000
4700
3900
2400
4000
3100
7100
6100
5700
5000
4700
3900
2700
4900
4000
3100
5000
4100
2300
1900
1800
1300
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
8
8
8
8
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3
3
3
3
330
330
330
330
330
330
330
330
330
330
330
330
330
330
330
470
470
470
470
470
470
470
470
470
470
470
680
680
680
680
680
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1500
100
100
100
100
L/6032-19
L/6032-19
W/7343-15
W/7343-15
W/7343-15
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
D/7343-31
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
C/6032-28
C/6032-28
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
Y/7343-40
Y/7343-40
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
Y/7343-40
Y/7343-40
Y/7343-40
X/7343-43
X/7343-43
B/3528-21
B/3528-21
B/3528-21
B/3528-21
T520L337M2R5A(1)E012
T520L337M2R5A(1)E025
T520W337M2R5A(1)E015
T520W337M2R5A(1)E025
T520W337M2R5A(1)E040
T520V337M2R5A(1)E006
T520V337M2R5A(1)E007
T520V337M2R5A(1)E009
T520V337M2R5A(1)E012
T520V337M2R5A(1)E015
T520V337M2R5A(1)E018
T520V337M2R5A(1)E025
T520V337M2R5A(1)E040
T520D337M2R5A(1)E006
T520D337M2R5A(1)E007
T520V477M2R5A(1)E006
T520V477M2R5A(1)E007
T520V477M2R5A(1)E009
T520V477M2R5A(1)E012
T520V477M2R5A(1)E015
T520V477M2R5A(1)E018
T520C477M2R5A(1)E025
T520C477M2R5A(1)E045
T520D477M2R5A(1)E006
T520D477M2R5A(1)E007
T520D477M2R5A(1)E009
T520D687M2R5A(1)E010
T520D687M2R5A(1)E015
T520D687M2R5A(1)E040
T520Y687M2R5A(1)E015
T520Y687M2R5A(1)E025
T520D108M2R5A(1)E4R5
T520D108M2R5A(1)E006
T520D108M2R5A(1)E007
T520D108M2R5A(1)E009
T520D108M2R5A(1)E010
T520D108M2R5A(1)E015
T520D108M2R5A(1)E030
T520Y108M2R5A(1)E010
T520Y108M2R5A(1)E015
T520Y108M2R5A(1)E025
T520X108M2R5A(1)E010
T520X158M2R5A(1)E015
T520B107M003A(1)E025
T520B107M003A(1)E035
T520B107M003A(1)E040
T520B107M003A(1)E070
µA at 25°C
Maximum/5
Minutes
83
83
83
83
83
83
83
83
83
83
83
83
83
83
83
118
118
118
118
118
118
118
118
118
118
118
170
170
170
170
170
250
250
250
250
250
250
250
250
250
250
250
375
30
30
30
30
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
6
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
mΩ at 25°C
100 kHz
Maximum
25
35
40
70
9
12
15
25
15
40
15
30
100
70
80
70
80
70
180
70
25
35
40
70
55
150
200
70
150
25
35
40
70
55
15
18
25
30
35
40
70
55
15
25
45
100
7
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
2300
1900
1800
1300
4600
3900
3500
2700
3900
2400
4100
2900
1000
1300
1200
1300
1200
1200
800
1200
2300
1900
1800
1300
1600
900
700
1200
800
2300
1900
1800
1300
1600
2900
2700
2300
2100
1900
1800
1300
1600
3300
2600
1900
1300
5200
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
8
8
8
8
10
10
10
10
10
10
10
10
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
10
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
150
150
150
150
330
330
330
330
680
680
1000
1000
15
33
33
47
47
47
68
68
68
68
68
68
68
100
100
100
100
100
100
100
100
100
150
150
150
150
150
150
150
150
150
150
150
150
150
B/3528-21
B/3528-21
B/3528-21
B/3528-21
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
D/7343-31
X/7343-43
X/7343-43
T/3528-12
A/3216-18
A/3216-18
A/3216-18
A/3216-18
T/3528-12
A/3216-18
T/3528-12
B/3528-21
B/3528-21
B/3528-21
B/3528-21
U/6032-15
A/3216-18
A/3216-18
T/3528-12
T/3528-12
B/3528-21
B/3528-21
B/3528-21
B/3528-21
U/6032-15
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
U/6032-15
C/6032-28
C/6032-28
C/6032-28
C/6032-28
V/7343-19
T520B157M003A(1)E025
T520B157M003A(1)E035
T520B157M003A(1)E040
T520B157M003A(1)E070
T520V337M003A(1)E009
T520V337M003A(1)E012
T520V337M003A(1)E015
T520V337M003A(1)E025
T520D687M003A(1)E015
T520D687M003A(1)E040
T520X108M003A(1)E015
T520X108M003A(1)E030
T520T156M004A(1)E100
T520A336M004A(1)E070
T520A336M004A(1)E080
T520A476M004A(1)E070
T520A476M004A(1)E080
T520T476M004A(1)E070
T520A686M004A(1)E180
T520T686M004A(1)E070
T520B686M004A(1)E025
T520B686M004A(1)E035
T520B686M004A(1)E040
T520B686M004A(1)E070
T520U686M004A(1)E055
T520A107M004A(1)E150
T520A107M004A(1)E200
T520T107M004A(1)E070
T520T107M004A(1)E150
T520B107M004A(1)E025
T520B107M004A(1)E035
T520B107M004A(1)E040
T520B107M004A(1)E070
T520U107M004A(1)E055
T520B157M004A(1)E015
T520B157M004A(1)E018
T520B157M004A(1)E025
T520B157M004A(1)E030
T520B157M004A(1)E035
T520B157M004A(1)E040
T520B157M004A(1)E070
T520U157M004A(1)E055
T520C157M004A(1)E015
T520C157M004A(1)E025
T520C157M004A(1)E045
T520C157M004A(1)E100
T520V157M004A(1)E007
µA at 25°C
Maximum/5
Minutes
45
45
45
45
99
99
99
99
204
204
300
300
6
13
13
19
19
19
27
27
27
27
27
27
27
40
40
40
40
40
40
40
40
40
60
60
60
60
60
60
60
60
60
60
60
60
60
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
7
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
mΩ at 25°C
100 kHz
Maximum
9
12
15
25
7
35
45
70
15
18
25
45
55
12
25
25
40
6
7
9
12
15
18
25
40
45
6
7
12
65
25
45
7
9
12
18
25
40
6
7
9
12
15
40
45
10
12
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
4600
3900
3500
2700
5700
1900
1700
1300
3300
3000
2600
1900
1700
3500
2400
2700
2100
5600
5200
4600
3900
3500
3200
2700
2200
2000
6100
5700
4300
1900
2600
1900
5200
4600
3900
3200
2700
2200
6100
5700
5000
4300
3900
2400
2200
4700
4300
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
10
10
10
10
10
8
8
8
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
150
150
150
150
150
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
330
330
330
330
330
330
330
330
330
330
330
330
330
330
330
470
470
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
B/3528-21
B/3528-21
B/3528-21
C/6032-28
C/6032-28
C/6032-28
C/6032-28
C/6032-28
L/6032-19
L/6032-19
W/7343-15
W/7343-15
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
D/7343-31
D/7343-31
D/7343-31
C/6032-28
C/6032-28
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
T520V157M004A(1)E009
T520V157M004A(1)E012
T520V157M004A(1)E015
T520V157M004A(1)E025
T520D157M004A(1)E007
T520B227M004A(1)E035
T520B227M004A(1)E045
T520B227M004A(1)E070
T520C227M004A(1)E015
T520C227M004A(1)E018
T520C227M004A(1)E025
T520C227M004A(1)E045
T520C227M004A(1)E055
T520L227M004A(1)E012
T520L227M004A(1)E025
T520W227M004A(1)E025
T520W227M004A(1)E040
T520V227M004A(1)E006
T520V227M004A(1)E007
T520V227M004A(1)E009
T520V227M004A(1)E012
T520V227M004A(1)E015
T520V227M004A(1)E018
T520V227M004A(1)E025
T520V227M004A(1)E040
T520V227M004A(1)E045
T520D227M004A(1)E006
T520D227M004A(1)E007
T520D227M004A(1)E012
T520D227M004A(1)E065
T520C337M004A(1)E025
T520C337M004A(1)E045
T520V337M004A(1)E007
T520V337M004A(1)E009
T520V337M004A(1)E012
T520V337M004A(1)E018
T520V337M004A(1)E025
T520V337M004A(1)E040
T520D337M004A(1)E006
T520D337M004A(1)E007
T520D337M004A(1)E009
T520D337M004A(1)E012
T520D337M004A(1)E015
T520D337M004A(1)E040
T520D337M004A(1)E045
T520D477M004A(1)E010
T520D477M004A(1)E012
µA at 25°C
Maximum/5
Minutes
60
60
60
60
60
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
88
132
132
132
132
132
132
132
132
132
132
132
132
132
132
132
188
188
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
8
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
mΩ at 25°C
100 kHz
Maximum
15
18
25
40
12
15
25
10
15
25
10
15
35
100
90
100
100
70
80
120
70
25
35
40
70
100
150
40
70
25
35
40
70
150
70
150
25
35
40
70
55
70
100
70
45
35
70
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
3900
3500
3000
2400
4300
3900
3000
4900
4000
3100
5000
4100
2700
1000
1100
1100
1000
1300
1200
1000
1200
2300
1900
1800
1300
1300
900
1600
1200
2300
1900
1800
1300
900
1200
800
2300
1900
1800
1300
1600
1400
1300
1035
1600
1500
1200
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
10
10
10
10
10
10
10
10
10
10
10
10
10
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
4
4
4
4
4
4
4
4
4
4
4
4
4
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
470
470
470
470
680
680
680
680
680
680
680
680
680
15
22
22
22
33
33
33
33
33
33
33
33
33
47
47
47
47
47
47
47
68
68
68
68
68
68
68
68
68
68
100
100
100
100
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
Y/7343-40
Y/7343-40
Y/7343-40
X/7343-43
X/7343-43
X/7343-43
T/3528-12
A/3216-18
A/3216-18
T/3528-12
A/3216-18
A/3216-18
A/3216-18
T/3528-12
B/3528-21
B/3528-21
B/3528-21
B/3528-21
C/6032-28
A/3216-18
T/3528-12
T/3528-12
B/3528-21
B/3528-21
B/3528-21
B/3528-21
A/3216-18
T/3528-12
T/3528-12
B/3528-21
B/3528-21
B/3528-21
B/3528-21
U/6032-15
U/6032-15
C/6032-28
A/3216-18
A/3216-18
A/3216-18
T/3528-12
T520D477M004A(1)E015
T520D477M004A(1)E018
T520D477M004A(1)E025
T520D477M004A(1)E040
T520D687M004A(1)E012
T520D687M004A(1)E015
T520D687M004A(1)E025
T520Y687M004A(1)E010
T520Y687M004A(1)E015
T520Y687M004A(1)E025
T520X687M004A(1)E010
T520X687M004A(1)E015
T520X687M004A(1)E035
T520T156M006A(1)E100
T520A226M006A(1)E090
T520A226M006A(1)E100
T520T226M006A(1)E100
T520A336M006A(1)E070
T520A336M006A(1)E080
T520A336M006A(1)E120
T520T336M006A(1)E070
T520B336M006A(1)E025
T520B336M006A(1)E035
T520B336M006A(1)E040
T520B336M006A(1)E070
T520C336M006A(1)E100
T520A476M006A(1)E150
T520T476M006A(1)E040
T520T476M006A(1)E070
T520B476M006A(1)E025
T520B476M006A(1)E035
T520B476M006A(1)E040
T520B476M006A(1)E070
T520A686M006A(1)E150
T520T686M006A(1)E070
T520T686M006A(1)E150
T520B686M006A(1)E025
T520B686M006A(1)E035
T520B686M006A(1)E040
T520B686M006A(1)E070
T520U686M006A(1)E055
T520U686M006A(1)E070
T520C686M006A(1)E100
T520A107M006ATE070
T520A107M006ATE045
T520A107M006ATE035
T520T107M006APE070
µA at 25°C
Maximum/5
Minutes
188
188
188
188
272
272
272
272
272
272
272
272
272
9
14
14
14
21
21
21
21
21
21
21
21
21
30
30
30
30
30
30
30
43
43
43
43
43
43
43
43
43
43
63
63
63
63
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
9
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
mΩ at 25°C
100 kHz
Maximum
55
15
18
25
35
40
45
70
55
40
7
9
12
15
45
25
45
35
35
70
150
200
25
35
45
70
35
15
25
45
55
45
55
12
25
25
40
6
7
9
12
15
18
25
40
45
6
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
1200
2900
2700
2300
1900
1800
1700
1300
1600
2100
5200
4600
3900
3500
2000
2600
1900
1900
1900
1300
900
800
2300
1900
1700
1300
1700
3300
2600
1900
1700
1700
1600
3500
2400
2700
2100
5600
5200
4600
3900
3500
3200
2700
2200
2000
6100
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
8
8
8
8
8
8
8
8
8
10
10
10
10
10
10
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
120
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
T/3528-12
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
B/3528-21
U/6032-15
W/7343-15
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
C/6032-28
C/6032-28
B/3528-21
M/3528-15
M/3528-15
M/3528-15
M/3528-15
B/3528-21
B/3528-21
B/3528-21
B/3528-21
T/3528-12
C/6032-28
C/6032-28
C/6032-28
C/6032-28
U/6032-15
U/6032-15
L/6032-19
L/6032-19
W/7343-15
W/7343-15
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
T520T107M006APE055
T520B107M006A(1)E015
T520B107M006A(1)E018
T520B107M006A(1)E025
T520B107M006A(1)E035
T520B107M006A(1)E040
T520B107M006A(1)E045
T520B107M006A(1)E070
T520U107M006A(1)E055
T520W107M006A(1)E040
T520V107M006A(1)E007
T520V107M006A(1)E009
T520V107M006A(1)E012
T520V107M006A(1)E015
T520V107M006A(1)E045
T520C107M006A(1)E025
T520C107M006A(1)E045
T520B127M006A(1)E035
T520M157M006A(1)E035
T520M157M006A(1)E070
T520M157M006A(1)E150
T520M157M006A(1)E200
T520B157M006A(1)E025
T520B157M006A(1)E035
T520B157M006A(1)E045
T520B157M006A(1)E070
T520T157M006A(1)E035
T520C157M006A(1)E015
T520C157M006A(1)E025
T520C157M006A(1)E045
T520C157M006A(1)E055
T520U157M006A(1)E045
T520U157M006A(1)E055
T520L157M006A(1)E012
T520L157M006A(1)E025
T520W157M006A(1)E025
T520W157M006A(1)E040
T520V157M006A(1)E006
T520V157M006A(1)E007
T520V157M006A(1)E009
T520V157M006A(1)E012
T520V157M006A(1)E015
T520V157M006A(1)E018
T520V157M006A(1)E025
T520V157M006A(1)E040
T520V157M006A(1)E045
T520D157M006A(1)E006
µA at 25°C
Maximum/5
Minutes
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
76
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
10
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
mΩ at 25°C
100 kHz
Maximum
7
15
25
55
25
35
45
70
15
18
25
45
7
9
12
15
18
25
40
6
7
9
15
18
25
40
50
40
70
15
18
25
40
45
9
10
15
18
25
40
45
10
15
25
40
55
35
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
5700
3900
3000
2000
2300
1900
1700
1300
3300
3000
2600
1900
5200
4600
3900
3500
3200
2700
2200
6100
5700
5000
3900
3500
3000
2400
2100
1800
1300
3500
3200
2700
2200
2000
5000
4700
3900
3500
3000
2400
2200
4900
4000
3100
2500
1800
2300
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
85
85
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
85
85
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
10
10
10
10
8
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
9
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
150
150
150
150
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
220
330
330
330
330
330
330
330
330
330
330
330
330
330
330
330
330
330
330
470
470
D/7343-31
D/7343-31
D/7343-31
D/7343-31
B/3528-21
B/3528-21
B/3528-21
B/3528-21
C/6032-28
C/6032-28
C/6032-28
C/6032-28
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
B/3528-21
B/3528-21
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
Y/7343-40
Y/7343-40
Y/7343-40
Y/7343-40
W/7343-15
W/7343-15
T520D157M006A(1)E007
T520D157M006A(1)E015
T520D157M006A(1)E025
T520D157M006A(1)E055
T520B227M006A(1)E025
T520B227M006A(1)E035
T520B227M006A(1)E045
T520B227M006A(1)E070
T520C227M006A(1)E015
T520C227M006A(1)E018
T520C227M006A(1)E025
T520C227M006A(1)E045
T520V227M006A(1)E007
T520V227M006A(1)E009
T520V227M006A(1)E012
T520V227M006A(1)E015
T520V227M006A(1)E018
T520V227M006A(1)E025
T520V227M006A(1)E040
T520D227M006A(1)E006
T520D227M006A(1)E007
T520D227M006A(1)E009
T520D227M006A(1)E015
T520D227M006A(1)E018
T520D227M006A(1)E025
T520D227M006A(1)E040
T520D227M006A(1)E050
T520B337M006A(1)E040
T520B337M006A(1)E070
T520V337M006A(1)E015
T520V337M006A(1)E018
T520V337M006A(1)E025
T520V337M006A(1)E040
T520V337M006A(1)E045
T520D337M006A(1)E009
T520D337M006A(1)E010
T520D337M006A(1)E015
T520D337M006A(1)E018
T520D337M006A(1)E025
T520D337M006A(1)E040
T520D337M006A(1)E045
T520Y337M006A(1)E010
T520Y337M006A(1)E015
T520Y337M006A(1)E025
T520Y337M006A(1)E040
T520W477M006A(1)E055
T520W477M006A(1)E035
µA at 25°C
Maximum/5
Minutes
95
95
95
95
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
139
208
208
208
208
208
208
208
208
208
208
208
208
208
208
208
208
208
208
296
296
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
11
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
mΩ at 25°C
100 kHz
Maximum
55
35
10
15
18
25
35
15
25
30
10
18
35
40
25
18
55
55
70
70
80
25
35
40
70
70
35
70
25
45
25
40
55
40
80
80
80
40
70
80
25
35
40
70
70
35
70
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
1800
2300
4900
4000
3700
3100
2600
3900
3000
2700
5000
3700
2700
2500
3100
3700
1800
1800
1200
1200
1100
2300
1900
1800
1300
1400
1900
1300
2600
1900
3000
2400
2000
2200
1200
1200
1200
1600
1200
1100
2300
1900
1800
1300
1400
1900
1300
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
85
85
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
20
20
8
8
8
8
8
8
8
8
8
8
8
8
10
10
10
10
8
8
8
8
8
8
8
8
8
8
8
8
8
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
470
470
470
470
470
470
470
470
470
470
470
470
470
470
680
680
1000
1500
22
33
33
33
33
33
33
33
47
47
82
82
150
150
150
150
10
15
22
33
33
33
33
33
33
33
33
47
47
V/7343-19
V/7343-19
Y/7343-40
Y/7343-40
Y/7343-40
Y/7343-40
Y/7343-40
D/7343-31
D/7343-31
D/7343-31
X/7343-43
X/7343-43
X/7343-43
X/7343-43
X/7343-43
X/7343-43
H/7260-20
H/7260-20
T/3528-12
T/3528-12
T/3528-12
B/3528-21
B/3528-21
B/3528-21
B/3528-21
U/6032-15
B/3528-21
B/3528-21
C/6032-28
C/6032-28
D/7343-31
D/7343-31
D/7343-31
V/7343-19
A/3216-18
A/3216-18
A/3216-18
T/3528-12
T/3528-12
T/3528-12
B/3528-21
B/3528-21
B/3528-21
B/3528-21
U/6032-15
B/3528-21
B/3528-21
T520V477M006A(1)E055
T520V477M006A(1)E035
T520Y477M006A(1)E010
T520Y477M006A(1)E015
T520Y477M006A(1)E018
T520Y477M006A(1)E025
T520Y477M006A(1)E035
T520D477M006A(1)E015
T520D477M006A(1)E025
T520D477M006A(1)E030
T520X477M006A(1)E010
T520X477M006A(1)E018
T520X477M006A(1)E035
T520X477M006A(1)E040
T520X687M006A(1)E025
T520X687M006A(1)E018
T520H108M006A(1)E055
T520H158M006A(1)E055
T520T226M008A(1)E070
T520T336M008A(1)E070
T520T336M008A(1)E080
T520B336M008A(1)E025
T520B336M008A(1)E035
T520B336M008A(1)E040
T520B336M008A(1)E070
T520U336M008A(1)E070
T520B476M008A(1)E035
T520B476M008A(1)E070
T520C826M008A(1)E025
T520C826M008A(1)E045
T520D157M008A(1)E025
T520D157M008A(1)E040
T520D157M008A(1)E055
T520V157M008A(1)E040
T520A106M010A(1)E080
T520A156M010A(1)E080
T520A226M010A(1)E080
T520T336M010A(1)E040
T520T336M010A(1)E070
T520T336M010A(1)E080
T520B336M010A(1)E025
T520B336M010A(1)E035
T520B336M010A(1)E040
T520B336M010A(1)E070
T520U336M010A(1)E070
T520B476M010A(1)E035
T520B476M010A(1)E070
µA at 25°C
Maximum/5
Minutes
296
296
296
296
296
296
296
296
296
296
296
296
296
296
428
428
630
945
18
26
26
26
26
26
26
26
38
38
66
66
120
120
120
120
10
15
22
33
33
33
33
33
33
33
33
47
47
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
12
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
mΩ at 25°C
100 kHz
Maximum
55
100
55
25
40
45
25
40
45
60
100
100
70
25
45
25
40
18
25
45
50
55
18
55
80
55
18
25
40
15
18
25
40
55
15
18
25
45
25
18
25
40
40
15
25
35
10
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
1600
1300
1600
2700
2100
1900
2700
2200
2000
1800
1400
1500
1300
2600
1900
2400
2100
3200
2700
2000
1900
1800
3500
2000
1700
1700
3200
2700
2200
3900
3500
3000
2400
2000
4000
3700
3100
2000
2700
3500
3000
2400
2500
4000
3100
2600
5000
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
8
8
8
10
10
8
10
10
10
10
10
10
8
8
8
8
10
10
10
10
10
10
10
10
10
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
47
47
68
68
68
68
68
68
68
68
68
68
100
100
100
100
100
100
100
100
100
100
100
100
100
150
150
150
150
150
150
150
150
150
150
150
150
220
220
220
220
220
220
330
330
330
330
U/6032-15
C/6032-28
U/6032-15
W/7343-15
W/7343-15
C/6032-28
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
B/3528-21
C/6032-28
C/6032-28
L/6032-19
W/7343-15
V/7343-19
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
D/7343-31
D/7343-31
C/6032-28
V/7343-19
V/7343-19
V/7343-19
D/7343-31
D/7343-31
D/7343-31
D/7343-31
D/7343-31
Y/7343-40
Y/7343-40
Y/7343-40
V/7343-19
V/7343-19
D/7343-31
D/7343-31
D/7343-31
Y/7343-40
Y/7343-40
Y/7343-40
Y/7343-40
X/7343-43
T520U476M010A(1)E055
T520C476M010A(1)E100
T520U686M010A(1)E055
T520W686M010A(1)E025
T520W686M010A(1)E040
T520C686M010A(1)E045
T520V686M010A(1)E025
T520V686M010A(1)E040
T520V686M010A(1)E045
T520V686M010A(1)E060
T520V686M010A(1)E100
T520D686M010A(1)E100
T520B107M010A(1)E070
T520C107M010A(1)E025
T520C107M010A(1)E045
T520L107M010A(1)E025
T520W107M010A(1)E040
T520V107M010A(1)E018
T520V107M010A(1)E025
T520V107M010A(1)E045
T520V107M010A(1)E050
T520V107M010A(1)E055
T520D107M010A(1)E018
T520D107M010A(1)E055
T520D107M010A(1)E080
T520C157M010A(1)E055
T520V157M010A(1)E018
T520V157M010A(1)E025
T520V157M010A(1)E040
T520D157M010A(1)E015
T520D157M010A(1)E018
T520D157M010A(1)E025
T520D157M010A(1)E040
T520D157M010A(1)E055
T520Y157M010A(1)E015
T520Y157M010A(1)E018
T520Y157M010A(1)E025
T520V227M010A(1)E045
T520V227M010A(1)E025
T520D227M010A(1)E018
T520D227M010A(1)E025
T520D227M010A(1)E040
T520Y227M010A(1)E040
T520Y337M010A(1)E015
T520Y337M010A(1)E025
T520Y337M010A(1)E035
T520X337M010A(1)E010
µA at 25°C
Maximum/5
Minutes
47
47
68
68
68
68
68
68
68
68
68
68
100
100
100
100
100
100
100
100
100
100
100
100
100
150
150
150
150
150
150
150
150
150
150
150
150
220
220
220
220
220
220
330
330
330
330
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
13
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Table 1 – Ratings & Part Number Reference cont'd
Rated
Voltage
Rated Case Code/
Cap
Case Size
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
mΩ at 25°C
100 kHz
Maximum
25
35
40
40
150
80
100
80
45
45
60
70
45
45
70
35
70
50
40
40
45
90
90
60
mA at 45°C
100 kHz
Reflow Temp
≤ 260ºC
ºC
3100
2700
2500
4500
800
1100
1100
1400
2000
2000
1800
1600
2000
2000
1600
2500
1800
2100
2500
2200
2000
1400
1400
1900
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
105
KEMET Part
Number
DC
Leakage
DF
ESR
% at 25°C
120 Hz
Maximum
10
10
10
10
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
VDC at 105°C
µF
KEMET/EIA
(See below for
part options)
10
10
10
11
12.5
12.5
16
16
16
16
16
16
16
16
16
16
16
16
16
20
20
20
25
25
330
330
330
47
10
15
10
22
33
33
33
33
47
47
47
47
47
68
150
22
22
22
15
15
X/7343-43
X/7343-43
X/7343-43
Q/7343-12
T/3528-12
T/3528-12
B/3528-21
C/6032-28
W/7343-15
V/7343-19
V/7343-19
V/7343-19
W/7343-15
V/7343-19
V/7343-19
D/7343-31
D/7343-31
D/7343-31
X/7343-43
V/7343-19
V/7343-19
V/7343-19
V/7343-19
D/7343-31
T520X337M010A(1)E025
T520X337M010A(1)E035
T520X337M010A(1)E040
T520Q476M011A(1)E040
T520T106M12RA(1)E150
T520T156M12RA(1)E080
T520B106M016A(1)E100 *
T520C226M016A(1)E080
T520W336M016A(1)E045
T520V336M016A(1)E045
T520V336M016A(1)E060
T520V336M016A(1)E070
T520W476M016A(1)E045 *
T520V476M016A(1)E045
T520V476M016A(1)E070 *
T520D476M016A(1)E035
T520D476M016A(1)E070 *
T520D686M016A(1)E050
T520X157M016A(1)E040
T520V226M020A(1)E040
T520V226M020A(1)E045
T520V226M020A(1)E090 *
T520V156M025A(1)E090 *
T520D156M025A(1)E060
µA at 25°C
Maximum/5
Minutes
330
330
330
52
13
19
16
35
53
53
53
53
75
75
75
75
75
109
240
44
44
44
38
38
25
15
D/7343-31
T520D156M025A(1)E080
38
10
80
1700
3
105
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
DC
Leakage
DF
ESR
Maximum
Allowable
Ripple Current
MSL
Maximum
Operating
Temp
(1) To complete KEMET part number, insert T = 100% Matte Tin (Sn) Plated, H = Standard Solder coated (SnPb 5% Pb minimum), N = Non-Magnetic 100% Tin
(Sn), M = Non-Magnetic (SnPb). Refer to Ordering Information for additional detail.
Also available on large (13 inch) reels. Add 7280 to the end of the part number.
Higher voltage ratings and tighter tolerance product including ESR may be substituted within the same size at KEMET's option. Voltage substitutions will be marked
with the higher voltage rating. Substitutions can include better than series.
* Part numbers with an asterisk are not recommended for new designs. Please use the T521 version of these part numbers.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
14
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Derating Guidelines
100%
Maximum
Recommended
Transient Voltage
(1 ms – 1 µs)
90%
90% of VR
VR
12.5 V ≤ VR ≤ 25 V
80% of VR
VR
Recommended
Application Voltage
< = 10 V
85%
-55°C to 105°C
2. V ≤ VR ≤ 10 V
Maximum
Transient
Voltage
95%
% Rated Voltage
Voltage Rating
Maximum
Recommended
Steady State
Voltage
80%
Recommended
Application
Voltage > 10 V
75%
70%
65%
60%
VR= Rated Voltage
55%
50%
-55
25
85
105
Temperature (°C)
Ripple Current/Ripple Voltage
Permissible AC ripple voltage and current are related to equivalent
series resistance (ESR) and the power dissipation capabilities of
the device. Permissible AC ripple voltage which may be applied is
limited by two criteria:
1. The positive peak AC voltage plus the DC bias voltage, if any,
must not exceed the DC voltage rating of the capacitor.
2. The negative peak AC voltage in combination with bias
voltage, if any, must not exceed the allowable limits specified for
reverse voltage. See the Reverse Voltage section for allowable
limits.
The maximum power dissipation by case size can be determined
using the table at right. The maximum power dissipation rating
stated in the table must be reduced with increasing environmental
operating temperatures. Refer to the table below for temperature
compensation requirements.
Temperature Compensation Multipliers
for Maximum Ripple Current
T ≤ 45°C
1.00
45° C < T ≤ 85°C
0.70
85°C < T ≤ 125°C
0.25
KEMET Case
Code
EIA
Case Code
T
M
A
B
U
L
C
W
V
Q
D
Y
X
H
3528–12
3528–15
3216–18
3528–21
6032–15
6032–19
6032–28
7343–15
7343–19
7343-12
7343–31
7343–40
7343–43
7360–20
Maximum Power
Dissipation (P max)
mWatts at 45°C with
+30°C Rise
105
120
112
127
135
150
165
180
187
170
225
241
247
187
The maximum power dissipation rating must be reduced with increasing
environmental operating temperatures. Refer to the Temperature
Compensation Multiplier table for details.
T= Environmental Temperature
Using the P max of the device, the maximum allowable rms ripple
current or voltage may be determined.
I(max) = √P max/R
E(max) = Z √P max/R
I = rms ripple current (amperes)
E = rms ripple voltage (volts)
P max = maximum power dissipation(watts)
R = ESR at specified frequency (ohms)
Z = Impedance at specified frequency (ohms)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
15
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Reverse Voltage
Polymer electrolytic capacitors are polar devices and may be permanently damaged or destroyed if connected in the wrong polarity.
These devices will withstand a small degree of transient voltage reversal for short periods as shown in the below table.
Temperature
Permissible Transient Reverse Voltage
25°C
55°C
85°C
105°C
125°C*
15% of Rated Voltage
10% of Rated Voltage
5% of Rated Voltage
3% of Rated Voltage
1% of Rated Voltage
*For series rated to 125°C
Table 2 – Land Dimensions/Courtyard
KEMET
Metric
Size
Code
Case
A
B
C
D
L
M
H
Q
T
U
V
W
X1
Y1
EIA
3216–18
3528–21
6032–25
7343–31
6032–19
3528–15
7360–20
7343–12
3528–12
6032–15
7343–20
7343–15
7343–43
7343–40
Density Level A:
Maximum (Most)
Land Protrusion (mm)
W
1.35
2.35
2.35
2.55
2.35
2.35
4.25
2.55
2.35
2.35
2.55
2.55
2.55
2.55
L
2.20
2.21
2.77
2.77
2.77
2.20
2.77
2.77
2.20
2.77
2.77
2.77
2.77
2.77
S
0.62
0.92
2.37
3.67
2.37
0.92
3.67
3.67
0.92
2.37
3.67
3.67
3.67
3.67
V1
6.02
6.32
8.92
10.22
8.92
6.32
10.22
10.22
6.32
8.92
10.22
10.22
10.22
10.22
Density Level B:
Median (Nominal)
Land Protrusion (mm)
V2
2.80
4.00
4.50
5.60
4.50
4.00
7.30
5.60
4.00
4.50
5.60
5.60
5.60
5.60
W
1.23
2.23
2.23
2.43
2.23
2.23
4.13
2.43
2.23
2.23
2.43
2.43
2.43
2.43
L
1.80
1.80
2.37
2.37
2.37
1.80
2.37
2.37
1.80
2.37
2.37
2.37
2.37
2.37
S
0.82
1.12
2.57
3.87
2.57
1.12
3.87
3.87
1.12
2.57
3.87
3.87
3.87
3.87
V1
4.92
5.22
7.82
9.12
7.82
5.22
9.12
9.12
5.22
7.82
9.12
9.12
9.12
9.12
Density Level C:
Minimum (Least)
Land Protrusion (mm)
V2
2.30
3.50
4.00
5.10
4.00
3.50
6.80
5.10
3.50
4.00
5.10
5.10
5.10
5.10
W
1.13
2.13
2.13
2.33
2.13
2.13
4.03
2.33
2.13
2.13
2.33
2.33
2.33
2.33
L
1.42
1.42
1.99
1.99
1.99
1.42
1.99
1.99
1.42
1.99
1.99
1.99
1.99
1.99
S
0.98
1.28
2.73
4.03
2.73
1.28
4.03
4.03
1.28
2.73
4.03
4.03
4.03
4.03
V1
4.06
4.36
6.96
8.26
6.96
4.36
8.26
8.26
4.36
6.96
8.26
8.26
8.26
8.26
V2
2.04
3.24
3.74
4.84
3.74
3.24
6.54
4.84
3.24
3.74
4.84
4.84
4.84
4.84
Density Level A: For low-density product applications. Recommended for wave solder applications and provides a wider process window for reflow solder processes.
Density Level B: For products with a moderate level of component density. Provides a robust solder attachment condition for reflow solder processes.
Density Level C: For high component desity product applications. Before adapting the minimum land pattern variations the user should perform qualification
testing based on the conditions outlined in IPC standard 7351 (IPC–7351).
1
Height of these chips may create problems in wave soldering.
2
Land pattern geometry is too small for silkscreen outline.
V1
L
L
W
W
V2
S
Grid Placement Courtyard
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
16
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Soldering Process
KEMET’s families of surface mount capacitors are compatible
with wave (single or dual), convection, IR, or vapor phase reflow
techniques. Preheating of these components is recommended
to avoid extreme thermal stress. KEMET's recommended profile
conditions for convection and IR reflow reflect the profile conditions
of the IPC/J–STD–020D standard for moisture sensitivity testing.
The devices can safely withstand a maximum of three reflow
passes at these conditions.
Please note that although the X/7343–43 case size can withstand
wave soldering, the tall profile (4.3 mm maximum) dictates care in
wave process development.
SnPb Assembly Pb-Free Assembly
Preheat/Soak
Temperature Minimum (TSmin)
100°C
150°C
Temperature Maximum (TSmax)
150°C
200°C
Time (ts) from Tsmin to Tsmax)
60 – 120 seconds
60 – 120 seconds
Ramp-up Rate (TL to TP)
3°C/seconds maximum
3°C/seconds maximum
Liquidous Temperature (TL)
183°C
217°C
Time Above Liquidous (tL)
60 – 150 seconds
220°C*
235°C**
60 – 150 seconds
250°C*
260°C**
Peak Temperature (TP)
Time within 5°C of Maximum
Peak Temperature (tP)
Ramp-down Rate (TP to TL)
20 seconds maximum
30 seconds maximum
6°C/seconds maximum
6°C/seconds maximum
Time 25°C to Peak Temperature
6 minutes maximum
8 minutes maximum
Note: All temperatures refer to the center of the package, measured on the
package body surface that is facing up during assembly reflow.
*Case Size D, E, P, Y, and X
**Case Size A, B, C, H, I, K, M, R, S, T, U, V, W, and Z
TP
TL
Temperature
Hand soldering should be performed with care due to the difficulty
in process control. If performed, care should be taken to avoid
contact of the soldering iron to the molded case. The iron should
be used to heat the solder pad, applying solder between the pad
and the termination, until reflow occurs. Once reflow occurs, the
iron should be removed immediately. “Wiping” the edges of a chip
and heating the top surface is not recommended.
Profile Feature
tP
Maximum Ramp Up Rate = 3ºC/seconds
Maximum Ramp Down Rate = 6ºC/seconds
tL
Tsmax
Tsmin
25
tS
25ºC to Peak
Time
Storage
All KO-CAP series are shipped in moisture barrier bags with a desiccant and moisture indicator card. These series are classified
as MSL3 (Moisture Sensitivity Level 3). Product contained within the moisture barrier bags should be stored in normal working
environments with temperatures not to exceed 40°C and humidity not in excess of 90% RH.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
17
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Construction
Polarity Stripe (+)
Molded Epoxy
Case
Detailed Cross Section
Silver Paint
(Fourth Layer)
Polarity
Bevel (+)
Wire
Leadframe
(- Cathode)
Wire
Weld
(to attach wire)
Carbon
(Third Layer)
Silver Adhesive
Leadframe
(+ Anode)
Molded Epoxy
Case
Polymer
(Second Layer)
Ta2O5 Dielectric
(First Layer)
Tantalum
Capacitor Marking
Version 1
Date Code *
KEMET
Organic
Polymer
Polarity
Indicator (+)
1 digit = Last number of Year
2 = 2012
3 = 2013
4 = 2014
5 = 2015
6 = 2016
7 = 2017
2nd and 3rd digit = Week of the Year
01 = 1st week of the Year to
52 = 52nd week of the Year
st
Picofarad
Code
KEMET
ID
Rated
Voltage
Date
Code*
* 230 = 30th week of 2012
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
18
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Capacitor Marking cont'd
Version 2
Date Code *
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Polarity
Indicator (+)
Date
Code
Voltage and
Capacitance
Code
2013
A
B
C
D
E
F
G
H
J
K
L
M
2014
N
P
Q
R
S
T
U
V
W
X
Y
Z
2015
a
b
c
d
e
f
g
h
j
k
l
m
2016
n
p
q
r
s
t
u
v
w
x
y
z
Code
e
g
j
A
Rated Voltage
2.5 V
4V
6V
10 V
Code
J7
N7
S7
W7
A8
E8
J8
N8
Capacitance
22
33
47
68
100
150
220
330
Version 3
Polarity
Indicator (+)
Voltage and
Capacitance
Code
ID Code
Date Code
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
19
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Tape & Reel Packaging Information
KEMET’smoldedchipcapacitorfamiliesarepackagedin8and12mmplastictapeon7"and13"reelsinaccordancewithEIA
Standard 481: Embossed Carrier Taping of Surface Mount Components for Automatic Handling. This packaging system is compatible
with all tape-fed automatic pick-and-place systems.
8 mm (0.315")
or
12 mm (0.472")
Top Tape Thickness
0.10 mm (0.004")
Maximum Thickness
180 mm (7.0")
or
330 mm (13.0")
Table 3 – Packaging Quantity
Case Code
KEMET
R
I
S
T
M
U
L
W
Z
Q
V
A
B
C
D
Y
X
E/T428P
H
EIA
2012-12
3216-10
3216-12
3528-12
3528-15
6032-15
6032-19
7343-15
7343-17
7343-12
7343-19
3216-18
3528-21
6032-28
7343-31
7343-40
7343-43
7360-38
7360-20
Tape Width
(mm)
7" Reel*
13" Reel*
8
8
8
8
8
12
12
12
12
12
12
8
8
12
12
12
12
12
12
2,500
3,000
2,500
2,500
2,000
1,000
1,000
1,000
1,000
1,000
1,000
2,000
2,000
500
500
500
500
500
1,000
10,000
12,000
10,000
10,000
8,000
5,000
3,000
3,000
3,000
3,000
3,000
9,000
8,000
3,000
2,500
2,000
2,000
2,000
3,000
* No C-Spec required for 7" reel packaging. C-7280 required for 13" reel packaging.
* A case with black epoxy only available in 7" reel
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
20
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Figure 1 – Embossed (Plastic) Carrier Tape Dimensions
P2
T
T2
ØDo
Po
[10 pitches cumulative
tolerance on tape ± 0.2 mm]
E1
Ao
F
Ko
B1
S1
W
E2
Bo
P1
T1
Center Lines of Cavity
B 1 is for tape feeder reference only,
including draft concentric about B o.
Embossment
For cavity size,
see Note 1 Table 4
ØD 1
Cover Tape
User Direction of Unreeling
Table 4 – Embossed (Plastic) Carrier Tape Dimensions
Metric will govern
Constant Dimensions — Millimeters (Inches)
Tape Size
D0
8 mm
12 mm
1.5 +0.10/-0.0
(0.059 +0.004/-0.0)
16 mm
D1 Minimum
Note 1
1.0
(0.039)
1.5
(0.059)
B1 Maximum
Note 4
4.35
(0.171)
E1
P0
1.75 ±0.10
(0.069 ±0.004)
4.0 ±0.10
(0.157 ±0.004)
P2
2.0 ±0.05
(0.079 ±0.002)
2.0 ±0.1
(0.079 ±0.059)
R Reference
Note 2
25.0
(0.984)
30
(1.181)
S1 Minimum
T Maximum T1 Maximum
Note 3
0.600
(0.024)
0.600
(0.024)
0.100
(0.004)
Variable Dimensions — Millimeters (Inches)
Tape Size
Pitch
E2 Minimum
F
8 mm
Single (4 mm)
6.25
(0.246)
3.5 ±0.05
(0.138 ±0.002)
12 mm
Single (4 mm) &
Double (8 mm)
8.2
(0.323)
10.25
(0.404)
16 mm
Triple (12 mm)
12.1
(0.476)
14.25
(0.561)
P1
2.0 ±0.05 or 4.0 ±0.10
(0.079 ±0.002 or 0.157 ±0.004)
2.0 ±0.05 (0.079 ±0.002) or 4.0
5.5 ±0.05
±0.10 (0.157 ±0.004) or 8.0 ±0.10
(0.217 ±0.002)
(0.315 ±0.004)
7.5±0.10
4.0 ±0.10 (0.157 ±0.004) to 12.0
(0.295 ±0.004)
±0.10 (0.472 ±0.004)
T2 Maximum
W Maximum A0, B0 & K0
2.5
(0.098)
8.3
(0.327)
4.6
(0.181)
12.3
(0.484)
8.0 (0.315)
16.3
(0.642)
Note 5
1. The embossment hole location shall be measured from the sprocket hole controlling the location of the embossment. Dimensions of embossment location and
hole location shall be applied independent of each other.
2. The tape, with or without components, shall pass around R without damage (see Figure 4).
3. If S1 < 1.0 mm, there may not be enough area for cover tape to be properly applied (see EIA Standard 481–D, paragraph 4.3, section b).
4. B1 dimension is a reference dimension for tape feeder clearance only.
5. The cavity defined by A0, B0 and K0 shall surround the component with sufficient clearance that:
(a) the component does not protrude above the top surface of the carrier tape.
(b) the component can be removed from the cavity in a vertical direction without mechanical restriction, after the top cover tape has been removed.
(c) rotation of the component is limited to 20° maximum for 8 and 12 mm tapes and 10° maximum for 16 mm tapes (see Figure 2).
(d) lateral movement of the component is restricted to 0.5 mm maximum for 8 mm and 12 mm wide tape and to 1.0 mm maximum for 16 mm tape (see Figure 3).
(e) see Addendum in EIA Standard 481–D for standards relating to more precise taping requirements.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
21
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Packaging Information Performance Notes
1. Cover Tape Break Force: 1.0 Kg minimum.
2. Cover Tape Peel Strength: The total peel strength of the cover tape from the carrier tape shall be:
Tape Width
Peel Strength
8 mm
0.1 to 1.0 Newton (10 to 100 gf)
12 and 16 mm
0.1 to 1.3 Newton (10 to 130 gf)
The direction of the pull shall be opposite the direction of the carrier tape travel. The pull angle of the carrier tape shall be 165° to 180°
from the plane of the carrier tape. During peeling, the carrier and/or cover tape shall be pulled at a velocity of 300 ±10 mm/minute.
3. Labeling: Bar code labeling (standard or custom) shall be on the side of the reel opposite the sprocket holes. Refer to EIA
Standards 556 and 624.
Figure 2 – Maximum Component Rotation
°
T
Maximum Component Rotation
Top View
Maximum Component Rotation
Side View
Typical Pocket Centerline
Tape
Width (mm)
8,12
16 – 200
Bo
Maximum
Rotation (
20
10
°
T)
Typical Component Centerline
Ao
Figure 3 – Maximum Lateral Movement
8 mm & 12 mm Tape
0.5 mm maximum
0.5 mm maximum
16 mm Tape
°
s
Tape
Maximum
Width (mm) Rotation (
8,12
20
16 – 56
10
72 – 200
5
°
S)
Figure 4 – Bending Radius
Embossed
Carrier
Punched
Carrier
1.0 mm maximum
1.0 mm maximum
R
Bending
Radius
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
R
T2015_T520 • 4/4/2016
22
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Figure 5 – Reel Dimensions
Full Radius,
See Note
W3 (Includes
Access Hole at
Slot Location
(Ø 40 mm minimum)
flange distortion
at outer edge)
W2 (Measured at hub)
D
A
(See Note)
N
C
(Arbor hole
diameter)
B
(see Note)
W1 (Measured at hub)
If present,
tape slot in core
for tape start:
2.5 mm minimum width x
10.0 mm minimum depth
Note: Drive spokes optional; if used, dimensions B and D shall apply.
Table 5 – Reel Dimensions
Metric will govern
Constant Dimensions — Millimeters (Inches)
Tape Size
A
B Minimum
C
D Minimum
8 mm
178 ±0.20
(7.008 ±0.008)
or
330 ±0.20
(13.000 ±0.008)
1.5
(0.059)
13.0 +0.5/-0.2
(0.521 +0.02/-0.008)
20.2
(0.795)
12 mm
16 mm
Variable Dimensions — Millimeters (Inches)
Tape Size
N Minimum
W1
W2 Maximum
W3
50
(1.969)
8.4 +1.5/-0.0
(0.331 +0.059/-0.0)
12.4 +2.0/-0.0
(0.488 +0.078/-0.0)
16.4 +2.0/-0.0
(0.646 +0.078/-0.0)
14.4
(0.567)
18.4
(0.724)
22.4
(0.882)
Shall accommodate tape width
without interference
8 mm
12 mm
16 mm
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
23
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Figure 6 – Tape Leader & Trailer Dimensions
Embossed Carrier
Carrier Tape
Punched Carrier
8 mm & 12 mm only
END
Round Sprocket Holes
START
Top Cover Tape
Elongated Sprocket Holes
(32 mm tape and wider)
Trailer
160 mm Minimum
Components
100 mm
Minimum Leader
400 mm Minimum
Top Cover Tape
Figure 7 – Maximum Camber
Elongated sprocket holes
(32 mm & wider tapes)
Carrier Tape
Round Sprocket Holes
1 mm Maximum, either direction
Straight Edge
250 mm
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
24
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Sasso Marconi, Italy
Tel: 39-051-939111
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
Skopje, Macedonia
Tel: 389-2-55-14-623
Shenzhen, China
Tel: 86-755-2518-1306
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Corporate Offices
Fort Lauderdale, FL
Tel: 954-766-2800
Kamen, Germany
Tel: 49-2307-438110
North America
Northern Europe
Wyboston, United Kingdom
Tel: 44-1480-273082
Taipei, Taiwan
Tel: 886-2-27528585
Espoo, Finland
Tel: 358-9-5406-5000
Southeast Asia
Singapore
Tel: 65-6701-8033
2835 KEMET Way
Simpsonville, SC 29681
Northeast
Wilmington, MA
Tel: 978-658-1663
Southeast
Lake Mary, FL
Tel: 407-855-8886
Central
Novi, MI
Tel: 248-994-1030
Beijing, China
Tel: 86-10-5877-1075
Shanghai, China
Tel: 86-21-6447-0707
Seoul, South Korea
Tel: 82-2-6294-0550
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Irving, TX
Tel: 972-915-6041
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
25
KEMET Organic Capacitor (KO-CAP®) – Industrial
T520 Low ESR Polymer Electrolytic, 2 – 25 VDC
Disclaimer
Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare
notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
providedbyKEMETwithreferencetotheuseofKEMET’sproductsisgivengratis,andKEMETassumesnoobligationorliabilityfortheadvicegivenorresultsobtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2015_T520 • 4/4/2016
26