TECHNICAL DATASHEET Rev. G XAIS3656 280W AC/DC High Efficiency Power Supply 207~294 VAC Input 28VDC Output at 10A Small 3.5” x 5” x 2” Aluminum Case FEATURES 92% Efficient at Full Load ISO9001 Compliant Active Power Factor Correction UL 1029 R/C Low THD EN55022 Class A Emissions Output Short Circuit and Over Current EN 61000-4-5 Surge Immunity Protection EN 61000-3-2 Harmonic Currents Conformal Coated 100% Burn-in DESCRIPTION The XAIS3656 AC/DC power supply provides 280 watts of output power and has an input voltage range of 207-294VAC with a 28VDC single output. This supply is housed in a small 3.5” x 5” x 2” aluminum case and features 1600VAC I/O isolation, high efficiency up to 92% at full load, and active power factor correction. This model also has over current and short circuit protection and is 100% burned-in. The XAIS3656 series was designed to be used in the industrial or commercial, indoor and outdoor lighting market. Some applications include lighting for parking lots, roadways, tunnels, warehouses, walkways, billboards, and garages. It can also be used for entertainment lighting applications such as moving heads, scanners, spot and wash lights, and digital projection. 04/06/2011 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Page 1 of 7 WALL INDUSTRIES, INC. Rev. G TECHNICAL DATASHEET XAIS3656 TECHNICAL SPECIFICATIONS MODEL NO. XAIS3656 All specifications are based on 25°C, Nominal Input Voltage and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. Related condition Min Nom Max Specification Switching Frequency 100 INPUT (Vin) Operating Voltage Range Frequency No Load Input Power (Graph 3) Power Factor (Graph 4) Vin = 250 Vac; Io = 11 A Total Harmonic Distortion (Graph 4) Inrush Current Vin = 294 Vac; cold start Vin = 260 – 294 Vac; Io = 11A Vin = 230 – 260 Vac; Io = 11A Vin = 207 – 230 Vac; Io = 11A EFFICIENCY (Graph 1) OUTPUT (Vo) Irms - I 1rms 240Vac Vin Irms 240Vac Unit kHz 207 0.96 250 60 7 0.98 294 9 - Vac Hz W - 5.3 10 % 91.0 90.5 89.5 20 92.0 91.5 91.0 - A - % 28.041 -1.4 28.447 28.856 +1.4 Vdc % Voltage Set Point at 25 °C – see Temperature Drift for Set Point at other Temperatures Load Regulation (Graph 5) Vo(Full Load) - Vo(Min. Load) Vin Nominal Line Vo(Min. Load) - 0.6 1.2 % Line Regulation (Graph 6) Vo( Low Line) - Vo(High Line) Io 100% Load Vo(Low Line) - 0.1 0.2 % Temperature Drift (Graph 7) Vo(25C) - Vo(-40C or 85C) Io 50% Load Vo(25C) - 0.01 0.02 % / °C Ripple – Switching Frequency Ripple – 60 Hz Current Current Limit (Graph 8) Over Voltage Limit 20 MHz BW 20 MHz BW Average Total Power Limited 0 14 33.6 100 700 18 34.9 200 900 10.0 22 36.3 mVpk-pk mVpk-pk A A Vdc - 1.2 0.5 700 - 2.0 1 1000 4 0 V ms ms V mS 1600 1600 1000 - 730 - Vac Vac Vdc µA -40 -40 -40 25 25 - 75 75 85 °C °C °C DYNAMIC RESPONSE Load step V Recovery Time Turn On Delay Turn On Overshoot Hold Up Time ISOLATION Input - Output Input - Chassis Output - Chassis Leakage Current THERMAL Ambient Operating Temperature Maximum Case Temperature Storage Temperature MTBF 25% to 75% Io, di/dt=0.25A/μS Recovery to within 1% VO Full Load Resistive Vin = 294 Vac Limited by Case Temperature See Figure 1 for Thermal Measurement Point MIL-HDBK-217F Notice 2; Tamb=25°C; Io = 11A MECHANICAL Weight 04/06/2011 162,059 See Figure 1 1.19 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 hours lbs Page 2 of 7 WALL INDUSTRIES, INC. Rev. G TECHNICAL DATASHEET XAIS3656 Figure 1: Mechanical Dimensions Unit: inches [mm] 04/06/2011 Thermal Measurement Point Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Page 3 of 7 WALL INDUSTRIES, INC. TECHNICAL DATASHEET Rev. G XAIS3656 DESIGN CONSIDERATIONS Over Current Protection The converter is protected from short circuit and over current conditions. Upon sensing a short circuit or an over current condition the converter will immediately shut off, and after a short delay try to restart. This is called a ‘hiccup’ mode and this mode will persist until the short circuit or over current condition is removed. Over Temperature Protection The converter is NOT protected from over temperature conditions. Exceeding the maximum rated case temperature may cause permanent damage to the unit. Fusing The input to the converter is protected with a UL R/C fuse. This fuse is NOT user replaceable. UL Recognition UL R/C FNFT2.E330012 (Electric Discharge Lamp Control Equipment, Specialty – Component) - UL Standard for Electric Discharge Lamp Control Equipment, Miscellaneous, UL 1029 and Electronic Ballasts UL 935. UL R/C FNFT8.E330012 (Electric Discharge Lamp Control Equipment, Specialty Certified for Canada – Component) - CSA Standard for Equipment for Use With Electric Discharge Lamps, C22.2, No. 74. For use in permanently connected (fixed) equipment only within a Grounded Electrical Enclosure. Input wiring must use 18 AWG copper wire. Emissions Accordance - CFR Title 47 FCC Part 15 Subpart B, Class A - ICES-003, Issue 4, Class A - CNS 13438, Class A - VCCI V-3/2005.04 and V-4/2003.04 - EN55022:2006+A1:2007, Class A - ACMA AS/NZS CISPR22 2006, Class A - EN 61000-3-2 Limits for Harmonic Current Emissions (Class C) - EN61000-4-5 (1995-02) A1 (2001) 2 KV Line-Line, 4 KV Line-Neutral Graph 1: Efficiency vs. Output Current 94% 92% 90% 88% 86% 290 Vac 260 Vac 230 Vac 210 Vac Efficiency (%) 84% 82% 80% 78% 76% 74% 72% 70% 68% 66% 64% 0 1 2 3 4 5 6 7 8 9 10 11 Io (A) 04/06/2011 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Page 4 of 7 WALL INDUSTRIES, INC. TECHNICAL DATASHEET Rev. G XAIS3656 Graph 2: Efficiency vs. Temperature (Io=11A) 94% 93% Efficiency (%) 92% 91% 90% 290 Vac 250 Vac 210 Vac 89% 88% 87% 86% -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 10 11 Case Temperature (°C) Graph 3: Power Dissipation vs. Output Current 35 210 Vac 230 Vac 260 Vac 290 Vac 30 P diss (W) 25 20 15 10 5 0 0 1 2 3 4 5 6 7 8 9 Io (A) Graph 4: Input Power Factor and THD 1.00 40 0.95 PF - 210 Vac PF - 260 Vac THD - 210 Vac THD - 260 Vac 0.85 PF - 230 Vac PF - 290 Vac THD - 230 Vac THD - 290 Vac 30 0.80 0.75 20 0.70 0.65 THD (%) Power Factor 0.90 10 0.60 0.55 0.50 0 1 04/06/2011 2 3 4 5 6 I o (A) 7 8 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 9 10 11 Page 5 of 7 WALL INDUSTRIES, INC. Rev. G Graph 5: Load Regulation XAIS3656 Graph 6: Line Regulation 0.20% 1.00% 0.80% 0.15% 0.60% 200 Vac 230 Vac 260 Vac 290 Vac 0.10% Regulation (%) 0.40% Regulation (%) TECHNICAL DATASHEET 0.20% 0.00% -0.20% 0.05% 0.00% Io=0A Io=2A Io=5A Io=8A Io=11A -0.05% -0.40% -0.10% -0.60% -0.15% -0.80% -1.00% 0 1 2 3 4 5 6 7 8 9 10 -0.20% 200 11 230 260 Io (A) 290 Vin (V) Graph 8: Over Current vs. Temperature Graph 7: Output Temperature Drift (Vin = 250 Vac; Io=11 A) 18 1.0% 0.8% 15 0.6% 0.4% 12 Iop (A) %Vo 0.2% 0.0% 9 -0.2% 6 -0.4% -0.6% 3 -0.8% -1.0% 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 -40 -30 -20 -10 Tcase (°C) 04/06/2011 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 0 10 20 30 40 50 60 70 80 Tcase (°C) Page 6 of 7 WALL INDUSTRIES, INC. Rev. G TECHNICAL DATASHEET XAIS3656 COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 04/06/2011 (603)778-2300 (888)587-9255 (603)778-9797 [email protected] www.wallindustries.com 5 Watson Brook Rd. Exeter, NH 03833 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Page 7 of 7