Errata: CS5371/72

Errata: CS5371/72 Errata
(Reference CS5371/72 data sheet revision DS255F2 dated SEP ’05)
Erratum #1 : THD for ±5% tolerance unipolar power supplies.
Description:
Characterization testing shows degraded total harmonic distortion performance for
certain unipolar power supply conditions.
Modulator does not meet -112 dB maximum THD performance for the following power
supply configurations:
Test Conditions
VA+
VA-
VD
Max THD
-5% Unipolar Analog / -5% Digital
+4.75 V
0V
+3.135 V
-100 dB
-5% Unipolar Analog / +5% Digital
+4.75 V
0V
+5.25 V
-100 dB
+5% Unipolar Analog / -5% Digital
+5.25 V
0V
+3.135 V
-100 dB
+5% Unipolar Analog / +5% Digital
+5.25 V
0V
+5.25 V
-100 dB
Work Around:
Use of a unipolar analog power supply (VA+ = +5 V, VA- = GND) is not recommended.
If unipolar operation is required, use a nominal +5.00 V analog power supply to
achieve data sheet performance.
Erratum #2 : CS5371 DC input glitch.
Description:
Applying a large DC input to the CS5371 device will sometimes show a 1 to 3 second
glitch in the conversion output. This glitch is not present over short time scales or with
a terminated input.
Work Around:
Connect pin 13 to GND. Power consumption will increase by 2x.
CONTACTING CIRRUS LOGIC SUPPORT
For a complete listing of direct Distributor, Sales, and Sales Representative contacts, visit the
Cirrus Logic website at http://www.cirrus.com.
http://www.cirrus.com
Copyright © Cirrus Logic, Inc. 2005
(All Rights Reserved)
ER255D2
SEP ‘05
Erratum #3 : CS5372 power down behavior.
Description:
Powering down only one channel of CS5372 can cause a 1 to 3 second glitch in the
conversion output when measuring large DC signals. This glitch is not present over
short time scales or with a terminated input.
Work Around:
Power down both PWDN1 and PWDN2 together when powering down the device.
2
ER255D2