Download Data Sheet

DATASHEET
Rev. C
LANEUW3 SERIES
4:1 Ultra Wide Input Voltage Range
Single and Dual Outputs
0.86” x 0.36” x 0.44” SIP Package
3 Watt DC/DC Power Converters
FEATURES
• 3 Watts Maximum Output Power
• Output Current up to 700mA
• Single and Dual Outputs
• 4:1 Ultra Wide Input Voltage Range
• 0.86 x 0.36 x 0.44 Inch SIP Package
• High Efficiency up to 82%
• 1600VDC I/O Isolation (3000VDC I/O Isolation Available)
APPLICATIONS
• Low Ripple & Noise
• Wireless Networks
• External ON/OFF Control
• Telecom / Datacom
• Switching Frequency (100KHz, min)
• Industry Control Systems
• Continuous Short Circuit Protection
• Measurement Equipment
• UL94V-V0 Case Potting Materials
• Semiconductor Equipment
• ISO9001 Certified Manufacturing Facilities
• CE Mark Meets 2006/95/EC, 93/68/EEC, and 2004/108/EC
OPTIONS
• 3000VDC I/O Isolation (Suffix “H”)
• UL60950-1, EN60950-1, and IEC60950-1 Safety Approvals
• Compliant to RoHS EU Directive 2002/95/EC
DESCRIPTION
The LANEUW3 series of DC/DC power converters provides 3 Watts of output power in a 0.86” x 0.36” x 0.44” SIP
package without derating up to 71°C. This series has single and dual output models with 4:1 ultra wide input voltage
ranges of 4.5-18VDC, 9-36VDC, and 18-75VDC. Some features include high efficiency, low ripple and noise, 1600VDC
(3000VDC optional) I/O isolation, remote ON/OFF, and continuous short circuit protection. All models are RoHS
compliant and have UL60950-1, EN60950-1, and IEC60950-1 safety approvals. These converters are ideally suited for
telecommunications, mobile telecom, test equipment, and industrial applications.
11/10/2010
Wall Industries, Inc. 37 Industrial Drive Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 1 of 5
LANEUW3 Series
Single & Dual Outputs
4:1 Input Voltage Range
3 Watt DC/DC Power Converters
Rev. C
SPECIFICATIONS: LANEUW3 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Nom
Max
12VDC nominal input models
24VDC nominal input models
48VDC nominal input models
12VDC nominal input models
24VDC nominal input models
48VDC nominal input models
12VDC nominal input models
24VDC nominal input models
48VDC nominal input models
4.5
9
18
12
24
48
18
36
75
36
50
100
Low line to high line at full load
No load to full load
5% load to 100% load
Asymmetrical load 25%/100% full load
Full load an nominal Vin
-0.2
-1.0
-0.5
-5
-1
Unit
INPUT SPECIFICATIONS
Input Voltage Range
Input Surge Voltage (100ms max)
Input Reflected Ripple Current (See Note 6)
Input Filter
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation
Load Regulation
Cross Regulation (Dual Output Models)
Voltage Accuracy
Output Power
Output Current
Ripple & Noise (20MHz Bandwidth)
Transient Response Recovery Time
Start-Up Time
Minimum Load
Temperature Coefficient
PROTECTION
Short Circuit Protection
GENERAL SPECIFICATIONS
Efficiency
Switching Frequency
Isolation Voltage (Input to Output)
VDC
25
10
8
Capacitor type
mAp-p
See Table
+0.2
+1.0
+0.5
+5
+1
3
%
%
%
%
W
See Table
Nominal Vin and full load
25% load step change
Nominal Vin and constant resistive load
30
250
30
30
Power Up
Remote ON/OFF
0
-0.02
mVp-p
µs
ms
%
%/°C
+0.02
continuous, automatic recovery
Nominal Vin and full load
Full load to minimum load
Standard
Suffix “H”
See Table
100
1600
3000
10
Isolation Resistance
Standard
Isolation Capacitance
Suffix “H” (See Note 9)
REMOTE ON/OFF (See Page 4 for application circuits)
DC/DC ON
Remote ON/OFF
DC/DC OFF
Remote Off State Input Current
Nominal Vin
ENVIRONMENTAL SPECIFICATIONS
Without derating
Operating Ambient Temperature
With derating
Storage Temperature
Relative Humidity
Thermal Shock
Vibration
BELLCORE TR-NWT-000332
MTBF (See Note 1)
MIL-HDBK-217F
PHYSICAL SPECIFICATIONS
Case Material
Base Material
Potting Material
Weight
Dimensions (L x W x H)
SAFETY & EMC CHARACTERISTICS
Safety Approvals
EMI (See Note 6)
EN55022
ESD
EN61000-4-2
Radiated Immunity
Fast Transient (See Note 7)
Surge (See Note 7)
Conducted Immunity
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
11/10/2010
VDC
KHz
VDC
GΩ
200
40
pF
Open or high impedance
Control pin applied current 2 ~ 4mA max. (via 1KΩ)
2.5
mA
-40
+71
-55
5
+71
+100
+125
95
MIL-STD-810F
MIL-STD-810F
3,963,000 hours
1,707,000 hours
°C
°C
% RH
Non-conductive black plastic
None
Silicon (UL94-V0)
0.17oz (4.8g)
0.86 x 0.36 x 0.44 inches (21.8 x 9.2 x 11.1 mm)
IEC60950-1, UL60950-1, EN60950-1
Class A
Air
Contact
±8KV
±6KV
10 V/m
±2KV
±1KV
10 Vrms
Wall Industries, Inc. 37 Industrial Drive Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Page 2 of 5
LANEUW3 Series
Single & Dual Outputs
4:1 Input Voltage Range
3 Watt DC/DC Power Converters
Rev. C
MODEL SELECTION TABLES
SINGLE OUTPUT MODELS
Model Number
LANEUW1233R3
LANEUW1205R3
LANEUW1209R3
LANEUW1212R3
LANEUW1215R3
LANEUW2433R3
LANEUW2405R3
LANEUW2409R3
LANEUW2412R3
LANEUW2415R3
LANEUW4833R3
LANEUW4805R3
LANEUW4809R3
LANEUW4812R3
LANEUW4815R3
Input Voltage
12 VDC
(4.5 – 18 VDC)
24 VDC
(9 – 36 VDC)
48 VDC
(18 – 75 VDC)
Output
Voltage
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
Output Current
Min Load Full Load
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
700mA
600mA
333mA
250mA
200mA
700mA
600mA
333mA
250mA
200mA
700mA
600mA
333mA
250mA
200mA
Input Current
(3)
(2)
No Load
Full Load
35mA
40mA
40mA
40mA
40mA
20mA
20mA
19mA
20mA
19mA
12mA
12mA
13mA
14mA
14mA
285mA
338mA
333mA
329mA
329mA
140mA
165mA
165mA
160mA
160mA
71mA
82mA
82mA
81mA
81mA
Output (4)
Maximum (5)
Efficiency(4)
Ripple & Noise
Capacitive Load
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
30mVp-p
74%
78%
79%
80%
80%
75%
80%
80%
82%
82%
74%
80%
80%
81%
81%
Output
Power
3300μF
1680μF
1000μF
820μF
680μF
3300μF
1680μF
1000μF
820μF
680μF
3300μF
1680μF
1000μF
820μF
680μF
2.3W
3W
3W
3W
3W
2.3W
3W
3W
3W
3W
2.3W
3W
3W
3W
3W
Maximum (5)
Capacitive Load
Output
Power
DUAL OUTPUT MODELS
Model Number
LANEUW1205RD3
LANEUW1212RD3
LANEUW1215RD3
LANEUW2405RD3
LANEUW2412RD3
LANEUW2415RD3
LANEUW4805RD3
LANEUW4812RD3
LANEUW4815RD3
Input Voltage
12 VDC
(4.5 – 18 VDC)
24 VDC
(9 – 36 VDC)
48 VDC
(18 – 75 VDC)
Output
Voltage
Output Current
Min Load Full Load
Input Current
(3)
(2)
No Load
Full Load
Output (4)
Efficiency(4)
Ripple & Noise
±5 VDC
0mA
±300mA
40mA
329mA
30mVp-p
80%
±1000μF
3W
±12 VDC
0mA
±125mA
40mA
329mA
30mVp-p
80%
±470μF
3W
±15 VDC
0mA
±100mA
40mA
329mA
30mVp-p
80%
±330μF
3W
±5 VDC
0mA
±300mA
25mA
167mA
30mVp-p
79%
±1000μF
3W
±12 VDC
0mA
±125mA
25mA
162mA
30mVp-p
81%
±470μF
3W
±15 VDC
0mA
±100mA
25mA
162mA
30mVp-p
81%
±330μF
3W
±5 VDC
0mA
±300mA
14mA
84mA
30mVp-p
79%
±1000μF
3W
±12 VDC
0mA
±125mA
14mA
81mA
30mVp-p
81%
±470μF
3W
±15 VDC
0mA
±100mA
14mA
81mA
30mVp-p
81%
±330μF
3W
NOTES
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40°C.
MIL-HDBK-217F Notice2 @Ta=25°C, Full load (Ground, Benign, controlled environment).
2. Maximum value at nominal input voltage and full load.
3. Typical value at nominal input voltage and no load.
4. Typical value at nominal input voltage and full load.
5. Test by minimum Vin and constant resistive load.
6. The LANEUW3 series meets EN55022 Class A and input reflected ripple current with an external L-C filter before the input pins to
the converter. (See Class B figure for connecting network)
Recommended: 12Vin: C1=4.7µF/25V 1812 MLCC L1=2.2µH 0504 SMD Inductor P/N: PMT-059
24Vin: C1=2.2µF/50V 1812 MLCC L1=10µH 0504 SMD Inductor P/N: PMT-047
48Vin: C1=2.2µF/100V 1812 MLCC L1=10µH 0504 SMD Inductor P/N: PMT-047
7. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor suggested is
Nippon chemi-con KY series, 100μF /100V, ESR 110mΩ.
8. To order 3000VDC I/O isolation version, add the suffix “H” to the model number (Ex: LANEUW2405R3H).
9. CAUTION: This power module is not internally fused. An input line fuse must always be used.
Due to advances in technology, specifications are subject to change without notice.
11/10/2010
Wall Industries, Inc. 37 Industrial Drive Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 3 of 5
LANEUW3 Series
Single & Dual Outputs
4:1 Input Voltage Range
3 Watt DC/DC Power Converters
Rev. C
REMOTE ON/OFF APPLICATION CIRCUITS
DC-DC OFF
DC-DC ON
+Input
1KΩ
3mA current
Source
+Input
Ctrl
1KΩ
3mA current
Source
-Input
Ctrl
-Input
CHARACTERISTICS
LANEUW2405R3 Derating Curve
LANEUW2405R3 Efficiency vs Input Voltage
Recommended Filter for EN55022 Class B Compliance
LANEUW2405R3 Efficiency vs Output Load
Recommended EN55022 Class B Filter Circuit Layout
L1
+INPUT
+Vin
+Vout
C1
LOAD
-INPUT
-Vin
-Vout
D/D Converter
The components used in the figure above are as follows
C1
L1
LANEUW12xxx
10μF/25V
1812 MLCC
2.2μH 0504 SMD Inductor
PMT-059
LANEUW24xxx
6.8μF/50V
1812 MLCC
18μH 0504 SMD Inductor
PMT-046
LANEUW48xxx
2.2μF/100V
1812 MLCC
18μH 0504 SMD Inductor
PMT-046
11/10/2010
Wall Industries, Inc. 37 Industrial Drive Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 4 of 5
LANEUW3 Series
Single & Dual Outputs
4:1 Input Voltage Range
3 Watt DC/DC Power Converters
Rev. C
MECHANICAL DRAWINGS
Unit: inches (mm)
PIN CONNECTIONS
Pin
Single
Dual
1
-Input
-Input
2
+Input
+Input
3
CTRL
CTRL
5
NC* / No Pin**
NC* / No Pin**
6
+Output
+Output
7
-Output
COM
8
NC
-Output
* NC pin for standard version
** No Pin for 3KV isolation version (suffix “H”)
1. Tolerance: x.xx±0.02 (x.x±0.5)
x.xxx±0.01 (x.xx±0.25)
2. Pin Pitch Tolerance: ±0.01 (0.25)
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will
provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one
example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its
customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for
your project above and beyond the design and production phases. Give us a call today to discuss your future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
11/10/2010
(603)778-2300
(888)587-9255
(603)778-9797
[email protected]
www.wallindustries.com
5 Watson Brook Rd.
Exeter, NH 03833
Wall Industries, Inc. 37 Industrial Drive Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797