IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes Version 3.8.20 / 3.9.7 April 2015 www.sixnet.com IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes No part of this publication, or any software included with it, may be reproduced, stored in a retrieval system or transmitted in any form or by any means, including photocopying, electronic, mechanical, recording or otherwise, without the prior written permission of the copyright holder. Sixnet, Inc. (Sixnet) provides this document as is, without warranty of any kind either expressed or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Sixnet may make changes of improvements in the equipment, software or specifications described in this document at any time and without notice. These changes may be incorporated in new releases of this document. This document may contain technical inaccuracies or typographical errors. Sixnet and its subsidiaries waive responsibility for any labor, materials or costs incurred by any person or party as a result of using this document. Sixnet and any of its subsidiaries or other affiliates shall not be liable for any damages (including, but not limited to, consequential, indirect or incidental, special damages, or loss of profits or data) even if they were foreseeable and Sixnet has been informed of their potential occurrence arising out of or in connection with this document or its use. Computer Software Copyrights The Sixnet products described in this manual include copyrighted Sixnet computer programs stored in semi-conductor memories or other media. Laws in Canada, the United States and other countries preserve for Sixnet certain rights for copyrighted computer programs, including the exclusive right to copy or reproduce in any form the copyrighted computer program. Accordingly, any copyrighted Sixnet computer programs contained in the Sixnet products described in this manual may not be copied without the express written permission of Sixnet. Furthermore, the purchase of Sixnet products shall not be deemed to grant either directly or by implication, estoppels, or otherwise, any license under the copyrights, patents or patent applications of Sixnet, except for the normal nonexclusive, royalty-free license to use that arises by operation of laws in the sale of a product. Sixnet, Inc. 331 Ushers Road Ballston Lake, NY 12019 T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 2 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes TABLE OF CONTENTS 1 2 Related Products .................................................................................................................................................4 Upgrade Instructions ...........................................................................................................................................5 2.1 Normal Update .......................................................................................................................................................... 5 2.2 Advanced Update....................................................................................................................................................... 5 3 Release Notes .....................................................................................................................................................6 3.1 Version 3.8.20/3.9.7 – Release Notes – Apr 8, 2015 ................................................................................................. 6 3.2 Version 3.8.19/3.9.6 – Release Notes – Nov 15, 2013............................................................................................... 7 3.3 Version 3.8.18/3.9.5 – Release Notes – Oct 30, 2013 ............................................................................................... 8 3.4 Version 3.9.4 – Release Notes – Oct 12, 2013 ........................................................................................................... 9 3.5 Version 3.8.17 – Release Notes – Oct 12, 2013 ....................................................................................................... 10 3.6 Version 3.9.3 – Release Notes – June 14, 2013 ....................................................................................................... 11 3.7 Version 3.8.16 – Release Notes – June 14, 2012 ..................................................................................................... 12 3.8 Version 3.9.2 – Release Notes – October 17, 2012 ................................................................................................. 14 3.9 Version 3.8.15 – Release Notes – October 10, 2012 ............................................................................................... 15 3.10 Version 3.8.14 – Release Notes – August 24, 2012 ............................................................................................. 16 3.11 Version 3.8.13 – Release Notes – June 29, 2012 ................................................................................................. 17 3.12 Version 3.8.12 – Release Notes – April 04, 2012 ................................................................................................. 18 3.13 Version 3.9.1 – Release Notes – February 9, 2012 .............................................................................................. 19 3.14 Version 3.8.11 – Release Notes – July 07, 2011 .................................................................................................. 20 3.15 Version 3.8.10 – Release Notes – June 20, 2011 ................................................................................................. 21 3.16 Version 3.8.9 – Release Notes – February 15, 2011 ............................................................................................ 22 3.17 Version 3.8.8 – Release Notes – December 14, 2010.......................................................................................... 23 3.18 Version 3.8.7 – Release Notes – September 28, 2010 ........................................................................................ 25 3.19 Version 3.8.6 – Release Notes – September 17, 2010 ........................................................................................ 26 3.20 Version 3.8.5 – Release Notes – September 9, 2010........................................................................................... 27 3.21 Version 3.8.4 – Release Notes – June 7, 2010 ..................................................................................................... 29 3.22 Version 3.8.3 – Release Notes – February 18, 2010 ............................................................................................ 30 3.23 Version 3.8.2 – Release Notes – February 12, 2010 ............................................................................................ 31 3.24 Version 3.8.1 – Release Notes – January 11, 2010 .............................................................................................. 32 3.25 Version 3.8.0 – Release Notes – December 18, 2009.......................................................................................... 33 4 Support Information.......................................................................................................................................... 35 Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 3 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 1 Related Products This release applies to the following products: IndustrialPro™ Gateway wireless modems (BT-6X00 Series): – GSM/EDGE: BT-6401, BT-6401EB, BT-6421 – CDMA EvDO A: BT-6600, BT-6601, BT-6601EB, BT-6621 – GSM/HSPA: BT-6800, BT-6801, BT-6801EB, BT-6821 MobilityPro™ Gateway wireless modems with GPS (BT-5X00v2 Series): – CDMA EvDO A with GPS: BT-5600v2 – GSM/HSPA with GPS: BT-5800v2 MobilityPro™ Gateway wireless modems with GPS and Wi-Fi (BT-5X30v2 Series): – CDMA EvDO A with GPS and Wi-Fi: BT-5630v2 – GSM/HSPA with GPS and Wi-Fi: BT-5830v2 Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 4 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 2 Upgrade Instructions Table 1, below, provides a summary of the update procedure to follow depending on the firmware which currently resides in the modem (i.e. is being upgraded from). Model Advanced update required <= 2.x <= 3.4.9 Normal update BT-4000 or BT-5000 series BT-6000 or BT-5000v2 series >= 3.x >= 3.6.0 Advanced update for IPSec support1 N/A <= 3.6.1 Table 1 - Upgrade Process Matrix 2.1 Normal Update *When upgrading from 3.9.1 on the Wi-Fi units you must use the Advanced Update procedure for the initial update from 3.9.1. 1. Use an Ethernet crossover cable (BT-4000/BT-5000), an Ethernet straight or crossover cable (BT-6000/BT5000v2) or USB cable to connect modem and PC 2. Start BlueVue Device Manager (BVDM) and Click Change connection type and select Modem IP. 3. Type the modem IP address in the related field if needed a. For Ethernet connection the default Modem IP is 192.168.0.1 b. For USB connection, the default Modem IP is 192.168.111.1 4. After the modem is detected, click File > Configuration and click on the Firmware tab 5. Click Browse and Select the upd (update) file you want to use, then click Upgrade 6. Wait for the firmware update to end and the modem to restart 2.2 Advanced Upgrade *When upgrading from 3.9.1 on the Wi-Fi units you must use the Advanced Update procedure for the initial update from 3.9.1. Download the Advanced Upgrade Package from the Red Lion Controls website under Sixnet BT Series and follow the instructions in the "Advanced Firmware Update Procedure" (BT-6000 and BT-5000v2). 1 In this case, an advanced upgrade is necessary to gain IPsec support. IPsec functionality is optional, so if IPsec support is not required, a basic upgrade can be performed instead, assuming that the minimum release is met as per the “Advanced update required” column. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 5 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3 3.1 Release Notes Version 3.8.20/3.9.7 – Release Notes – Apr 8, 2015 The 3.8.20 release is intended for Industrial Pro™ Gateway (BT-6XXX) and MobilityPro™ Gateway (BT-5XXXv2) wireless modems with or without the USB Host extension. The 3.9.7 release is intended for MobilityPro™ Gateway (BT-5630v2 and BT-5830v2) wireless modems New Features & Improvements BLUEX-58 BLUEX-61 BLUEX-62 BLUEX-63 BLUEX-69 BLUEX-71 BLUEX-78 BLUEX-79 BLUEX-80 BLUEX-82 BLUEX-84 BLUEX-85 BLUEX-86 BLUEX-87 BLUEX-92 BLUEX-94 BLUEX-100 BLUEX-103 BLUEX-107 BLUEX-108 BLUEX-110 BLUEX-113 BLUEX-115 BLUEX-116 BLUEX-121 BLUEX-124 Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware RF Service type fixed to report correctly for MC8705 Added +BRFRST command to control RF module resets #18759, #36187 Kernel partition reflashing from kbt improved - #20098 Prevent sfm.bin from growing too large – #20463 Fix improper start of FTP Server on Wi-Fi Modems Fix IPREG incorrect string contents – #21611 Change PID/VID from BlueTree unique ID (170c/0001) to Windows RNDIS Generic (0525/a4a2) Update ATI1 Response for Wi-Fi Modems Update BT Log to reflect all new AT Commands bxgps Memory Leak fixed Shorten Ethernet autonegotiation time in Wi-Fi unit bootup Stuck SFM fixed when accepting 0 length ACK messages - #30779 Add Support for AT+BGPSMTN Add Support for AT+BGPSACCF Update MC8705 Power Status control NMEA ZDA Messages truncated when all GPS Messages enabled. Use +BSFMBS=136 Preventative Fix for inconsistent BEP node packets - #30779 Updated USB Power Down sequence to handle pl2303 - #39596 Shellshock vulnerability patch Added support for domain names in +BPNGKA - #46482 Fixed incorrect +BSIMNUM responses #41778 AT Command processor crash resets DO to off. #48413 MOM Checkin issue resolved - #54862 Prevent gps.log from filling /var - #57501 Additional preventions of AT Command Processor crash - #52090 Allow +BGETLG to exclude GPS data with +BGETLG=1 - #45027 Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 6 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.2 Version 3.8.19/3.9.6 – Release Notes – Nov 15, 2013 The 3.8.19 release is intended for Industrial Pro™ Gateway (BT-6XXX) and MobilityPro™ Gateway (BT-5XXXv2) wireless modems with or without the USB Host extension. The 3.9.6 release is intended for MobilityPro™ Gateway (BT-5630v2 and BT-5830v2) wireless modems New Features & Improvements BLUEX-45 BLUEX-54 Firmware Firmware 3.8.19 only: Updated 2.6.21 #btw12 FTDI Kernel Drivers (to 1.5.0). UDP packet of raw GPS data saved on SFM could not be sent out after reboot Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 7 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.3 Version 3.8.18/3.9.5 – Release Notes – Oct 30, 2013 The 3.8.18 release is intended for Industrial Pro™ Gateway (BT-6XXX) and MobilityPro™ Gateway (BT-5XXXv2) wireless modems with or without the USB Host extension. The 3.9.5 release is intended for MobilityPro™ Gateway (BT-5630v2 and BT-5830v2) wireless modems New Features & Improvements BLUEX-47 Firmware All non-BEP GPS messages in 3.8.17 were corrupted. Multiple issues appeared as a result. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 8 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.4 Version 3.9.4 – Release Notes – Oct 12, 2013 The 3.9.4 release is intended for MobilityPro™ Gateway (BT-5630v2 and BT-5830v2) wireless modems Dependencies IndustrialPro™ and MobilityPro™ Gateway BT-5x30v2 Series Current Version Minimum Version 2.6.27 #1 2.6.27 #1 2009.01-btw02 2009.01-btw02 3.0.0 3.0.0 Kernel Boot Loader File System Important Notes BT-5x30v2 modems require kernel 2.6.27 #1 or later and U-Boot 2009.01-btw02 or later. When upgrading from 3.9.1 on Wi-Fi units (BT-5630v2 / BT-5830v2) you MUST USE the Advanced Update procedure for the initial update from 3.9.1. New Features & Improvements ALL BLUEX-35 Firmware Firmware Same list as 3.8.17 WiFi AP mode compatibility fix with MC8705 HSPA+ on AT&T Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 9 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.5 Version 3.8.17 – Release Notes – Oct 12, 2013 The 3.8.17 release is intended for Industrial Pro™ Gateway (BT-6XXX) and MobilityPro™ Gateway (BT-5XXXv2) wireless modems with or without the USB Host extension. Dependencies Legacy modems BT-4000 / BT-5000 Series Current Version Minimum Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 Kernel Boot Loader File System IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version Minimum Version 2.6.21 #btw10/#btw11 2.6.21 #btw03 1.2.0-btw11 1.2.0-btw02 3.0.0 3.0.0 Important Notes BT-5x30v2 modems require kernel 2.6.27 #1 or later and U-Boot 2009.01-btw02 or later. BT-6400 series modems require kernel 2.6.21 #btw03 or later. IPSEC support is provided on BT-5000v2 and BT-6000 series with kernel 2.6.21 #btw04. BT-5600v2 and BT-5800 require U-Boot 1.2.0-btw03 (fix LED inversion during reset) or 1.2.0-btw04 (CPU boards with Atmel rev. B chip). BT-6000 and BT-5000v2 series needs kernel 2.6.21 #btw06 to support multicast forwarding on GRE tunnels. USB Host on BT-5000v2 requires kernel 2.6.21 #btw09 and u-boot 1.2.0-btw06. New Features & Improvements MS-399 Kernel WS-24 BLUEX-22 BLUEX-24 BLUEX-25 BLUEX-27 BLUEX-29 BLUEX-30 Firmware Firmware Firmware Firmware Firmware Firmware Firmware BLUEX-31 BLUEX-34 BLUEX-37 Firmware Firmware Firmware BLUEX-41 Firmware Updated 2.6.21 #btw10 (and #btw11) JFFS2 Kernel Drivers (from 2.6.22) to prevent boot lock conditions. GPS Filter Updated to ignore SBAS correction status for 3 or less satellites in a fix. BEP Distance reporting did not work properly with TAIP Non-BEP GPS Messages could not be transmitted on UDP BT6800/5800 HSPA MC8790 could get stuck on “Failed to get registration status” Report timer does not work. Affects AT+BEVRPR Duplicated TAIP messages caused early and often GPS chipset resets. Fix AT+BEVRPR Reports to local destination, with ACK flag disabled, get queued up and generated irregularly. HSPA+ MC8705 Reset fix for firmware T1_0_3_2AP. Switching between TAIP and NMEA reporting formats can become locked and reset the modem. Update default tcp_retries2 parameter (5 instead of 15) to more rapidly discover nonresponding servers. Fix missing SIGTERM messages on 3.8.16 to partner apps after +BIGNIT timeout Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 10 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.6 Version 3.9.3 – Release Notes – June 14, 2013 The 3.9.3 release is intended for MobilityPro™ Gateway (BT-5630v2 and BT-5830v2) wireless modems Dependencies Kernel Boot Loader File System IndustrialPro™ and MobilityPro™ Gateway BT-5x30v2 Series Current Version Minimum Version 2.6.27 #1 2.6.27 #1 2009.01-btw02 2009.01-btw02 3.0.0 3.0.0 Important Notes BT-5x30v2 modems require kernel 2.6.27 #1 or later and U-Boot 2009.01-btw02 or later. When upgrading from 3.9.1 on Wi-Fi units (BT-5630v2 / BT-5830v2) you MUST USE the Advanced Update procedure for the initial update from 3.9.1. New Features & Improvements 10853 10931 11145 11146 11163 11379 11596 11671 Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware MC8705 Support on 3.9.3 GPS Engine monitoring offers better GPS response +BWIFIMD return codes improved Wi-Fi Password handling improved for +BWIFIAPM Stability upgrades on Wi-Fi AP Performance +BWANDT race condition fixed against +BMTIME=Cell Firewall rules refined RF Module information missing from some BEP Payloads Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 11 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.7 Version 3.8.16 – Release Notes – June 14, 2012 The 3.8.16 release is intended for Industrial Pro™ Gateway (BT-6XXX) and MobilityPro™ Gateway (BT-5XXXv2) wireless modems with or without the USB Host extension. Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Version Minimum Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version Minimum Version 2.6.21 #btw09 2.6.21 #btw03 1.2.0-btw08 1.2.0-btw02 3.0.0 3.0.0 Important Notes BT-5x30v2 modems require kernel 2.6.27 #1 or later and U-Boot 2009.01-btw02 or later. BT-6400 series modems require kernel 2.6.21 #btw03 or later. IPSEC support is provided on BT-5000v2 and BT-6000 series with kernel 2.6.21 #btw04. BT-5600v2 and BT-5800 require U-Boot 1.2.0-btw03 (fix LED inversion during reset) or 1.2.0-btw04 (CPU boards with Atmel rev. B chip). BT-6000 and BT-5000v2 series needs kernel 2.6.21 #btw06 to support multicast forwarding on GRE tunnels. USB Host on BT-5000v2 requires kernel 2.6.21 #btw09 and u-boot 1.2.0-btw06. New Features & Improvements ID 9849 10044 10086 10413 10799 10926 10931 11058 11143 11150 11150 11186 11201 11201 Subject Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Description AT+BINITS allows multiple module AT commands in a single command. Sierra MC8705 Support Fixed - BCMODE=0 getting stuck while disabling PPP on IGN down New AT command AT+BIGNEN to enable/disable the ignition feature Partner App auto-recover race condition - Improved backup manifest handling. DHCP Server watcher added for compatibility with Embedded WinXP GPS Engine restart if unresponsive Revert to NMEA on unknown format with +BGPSPR=0,1,1 Log partition added, restart procedure unified Additional file synchronization after writes reviewed Kernel vm.dirty parameters reduced to prevent long write caching Default config file backups were missing CRC after AT&F, causing extra NAND writes NAND corruption prevention options +GPSFIL SOG LOG behavior and odometer saving updated Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 12 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes ID 11233 11242 11244 11264 11309 11310 11346 11354 11362 11379 11380 11397 11431 11472 11480 11529 11535 11640 BLUEX-7 9621 11054 11057 11292 11235 11238 11245 11293 11644 11402 Subject Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware Firmware SFM / BEP SFM / BEP SFM / BEP SFM / BEP SFM / BEP SFM / BEP SFM / BEP SFM / BEP SFM / BEP SFM / BEP Description Disabled Stored System Time option from AT+BMTIME AT+BDOSET. New optional parameter allows setting Digital Out without saving state AT+BIGNNET added to control PPP disconnect after IGN shutdown. BCMODE=0 prevented Fixed issue where Bluex fails to start multiple partner applications High CPU utilization fixed while FTP server is enabled Unfunctional downgrade prevented for units with MC8705 DCTM Optimization for loss of signal events Enhanced ping pattern for PNGKA to optimize RF de-idling on 2G Fixed - IPREG can report wrong IP after race condition reconnect Fixed - BWANDT can disconnect when BMTIME updates from cellular late Improved I/O Event (DI/DO) handling Protection of BGETLG to prevent excessively large log captures High CPU Utilization resolved under loss of signal FTDI device 6011 added for USB Serial +BSECUR=x at off-line/on-line mode RFPWRON improved across old and new firmwares of MC8790 Excessive Speeding with no GPS signal resolved with additional valid NMEA checks +BMTIME Offset fixed for GPS Mode, and reverts to archaic time when cell unavailable GPS Drift compensation in odometer Detect and prevent unconfigured events - Event 42/86 issue BEP messages with RSSI of 0 altered to 125 Oversize SFM file prevented Stuck SFM Queue prevented with Bad Header detection and removal Invalid response of +BSFMST fixed Improved AT+BSFMRM=1 to erase SFM queue Wrong BEP packet sequence number - Fixed Bad Index message BEP UDP packet fails due to network unreachable. Invalid Destination should not block Queue BEP message with zero length GP1 payload prevented +BEVCMD supports new AT+BDOSET save option Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 13 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.8 Version 3.9.2 – Release Notes – October 17, 2012 The 3.9.2 release is intended for MobilityPro™ Gateway (BT-5630v2 and BT-5830v2) wireless modems Dependencies Kernel Boot Loader File System IndustrialPro™ and MobilityPro™ Gateway BT-5x30v2 Series Current Version Minimum Version 2.6.27 #1 2.6.27 #1 2009.01-btw02 2009.01-btw02 3.0.0 3.0.0 Important Notes BT-5x30v2 modems require kernel 2.6.27 #1 or later and U-Boot 2009.01-btw02 or later. When upgrading from 3.9.1 on Wi-Fi units (BT-5630v2 / BT-5830v2) you must use the Advanced Update procedure for the initial update from 3.9.1. New Features & Improvements 10228 10213 Wi-Fi Wi-Fi AT+BIFCON supports Wi-Fi interfaces rd Supports BlueTree SDK and 3 party applications Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 14 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.9 Version 3.8.15 – Release Notes – October 10, 2012 The 3.8.15 release is intended for Industrial Pro™ Gateway (BT-6XXX) and MobilityPro™ Gateway (BT-5XXXv2) wireless modems with or without the USB Host extension. Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Version Minimum Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version Minimum Version 2.6.21 #btw09 2.6.21 #btw03 1.2.0-btw08 1.2.0-btw02 3.0.0 3.0.0 Important Notes BT-5x30v2 modems require kernel 2.6.27 #1 or later and U-Boot 2009.01-btw02 or later. BT-6400 series modems require kernel 2.6.21 #btw03 or later. IPSEC support is provided on BT-5000v2 and BT-6000 series with kernel 2.6.21 #btw04. BT-5600v2 and BT-5800 require U-Boot 1.2.0-btw03 (fix LED inversion during reset) or 1.2.0-btw04 (CPU boards with Atmel rev. B chip). BT-6000 and BT-5000v2 series needs kernel 2.6.21 #btw06 to support multicast forwarding on GRE tunnels. USB Host on BT-5000v2 requires kernel 2.6.21 #btw09 and u-boot 1.2.0-btw06. New Features & Improvements ID 10423 10447 10447 10088 Subject GPS Firmware Firmware Firmware Firmware Description Improved GPS odometer accuracy Update to read HEX ESN from MC5728V Sprint RF Logs exclude GPS logs in /nvlog/gps Limit for on-board GPS logs based on total disk usage +BDOSET: Do not persist option implemented with downward compatibility Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 15 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.10 Version 3.8.14 – Release Notes – August 24, 2012 The 3.8.14 release is intended for MobilityPro™ Gateway (BT-5600v2 and BT-5800v2) wireless modems with or without the USB Host extension. Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Version Minimum Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version Minimum Version 2.6.21 #btw09 2.6.21 #btw03 1.2.0-btw07 1.2.0-btw02 3.0.0 3.0.0 Important Notes BT-5x30v2 modems require kernel 2.6.27 #1 or later and U-Boot 2009.01-btw02 or later. BT-6400 series modems require kernel 2.6.21 #btw03 or later. IPSEC support is provided on BT-5000v2 and BT-6000 series with kernel 2.6.21 #btw04. BT-5600v2 and BT-5800 require U-Boot 1.2.0-btw03 (fix LED inversion during reset) or 1.2.0-btw04 (CPU boards with Atmel rev. B chip). BT-6000 and BT-5000v2 series needs kernel 2.6.21 #btw06 to support multicast forwarding on GRE tunnels. USB Host on BT-5000v2 requires kernel 2.6.21 #btw09 and u-boot 1.2.0-btw06. New Features & Improvements ID N/A 10134 Subject GPS GPS 10015 10015 10015 10015 10134 9841 9788 9817 10086 GPS GPS GPS GPS Firmware Firmware Firmware Firmware Firmware Description Kalman 1D filter implemented and is enabled by default. Device logging instantiated with AT+BGPSFIL=4/6 now includes compression archiving and more descriptive file names RMC Status "F" points are now considered valid and BEP-reportable. SOG is modified in the raw NMEA message for BEP-facing logs. CRC is updated. SOG is updated using 1 or 2 decimals of precision to match what the chip reports. Fixed precision issue of Copernicus I vs. II NMEA truncation Fixed ability to retrieve large device logs Fixed ability to delete GPS SOG logs (AT+BGPSFIL=0) Lost Partner Application fixed with manifest backup method RF Powerdown state saved prior to shutdown Improved cellular deregistration of connection upon IGN drop on BT5K Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 16 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.11 Version 3.8.13 – Release Notes – June 29, 2012 The 3.8.13 release is intended for MobilityPro™ Gateway (BT-5600v2 and BT-5800v2) wireless modems with or without the USB Host extension. Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Version Minimum Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version Minimum Version 2.6.21 #btw09 2.6.21 #btw03 1.2.0-btw07 1.2.0-btw02 3.0.0 3.0.0 Important Notes BT-5x30v2 modems require kernel 2.6.27 #1 or later and U-Boot 2009.01-btw02 or later. BT-6400 series modems require kernel 2.6.21 #btw03 or later. IPSEC support is provided on BT-5000v2 and BT-6000 series with kernel 2.6.21 #btw04. BT-5600v2 and BT-5800 require U-Boot 1.2.0-btw03 (fix LED inversion during reset) or 1.2.0-btw04 (CPU boards with Atmel rev. B chip). BT-6000 and BT-5000v2 series needs kernel 2.6.21 #btw06 to support multicast forwarding on GRE tunnels. USB Host on BT-5000v2 requires kernel 2.6.21 #btw09 and u-boot 1.2.0-btw06. New Features & Improvements ID 9771 9843 9841 9822 9787 9748 Subject Firmware GPS GPS Kernel Kernel Logging Description Fixed 3.8.12 downgrading issue Added new AT+BGPSKAL command for Kalman filter (GPS) Added AT+BGPSFIL and new GPS filter Turn on overcommit of system memory in Linux kernel SIP: scrolling issue in Cisco router console Updated Sog.log messages Refs Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 17 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.12 Version 3.8.12 – Release Notes – April 04, 2012 The 3.8.12 release is intended for MobilityPro™ Gateway (BT-5600v2 and BT-5800v2) wireless modems with or without the USB Host extension. Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Version Minimum Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version Minimum Version 2.6.21 #btw09 2.6.21 #btw03 1.2.0-btw07 1.2.0-btw02 3.0.0 3.0.0 Important Notes IPsec support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw04 or above. GRE tunnel support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw06 or above. USB Host support (MobilityPro™ Gateway only) requires kernel 2.6.21 #btw09 and u-boot 1.2.0-btw06. New Features & Improvements ID 1256 1255 1252 1251 1250 1249 1248 1243 8558 1241 1223 Subject Network RF Serial IP BEP BEP BEP AT Events Factory Tests Fire Wall RF Description Implemented TCP poll for Rastrac HSPA RF hangs in IP Pass-thru mode at Telus lab tests AT&C3 -- DCD signal is decided by SIP TCP connection status BEP events not sent while the server is available ignition status is falsely reported on IO1 payload +BEVENT? not working in BEP MOM Missing line feed character via serial port Local Event Going to Wrong Destination Expand the length for AT+BFACTINF command IP source violation in IP pass-through mode AT+BMDIAG to show override SPN name instead of network name Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 18 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.13 Version 3.9.1 – Release Notes – February 9, 2012 The 3.9.1 release is intended for MobilityPro™ Gateway (BT-5630v2 and BT-5830v2) wireless modems. Dependencies Kernel Boot Loader File System IndustrialPro™ and MobilityPro™ Gateway BT-5x30v2 Series Current Version Minimum Version 2.6.27 #1 2.6.27 #1 2009.01-btw02 2009.01-btw02 3.0.0 3.0.0 Important Notes BT-5x30v2 modems require kernel 2.6.27 #1 or later and U-Boot 2009.01-btw02 or later. When upgrading from 3.9.1 on Wi-Fi units (BT-5630v2 / BT-5830v2) you must use the Advanced Update procedure for the initial update from 3.9.1. New Features & Improvements 1173 1177 1187 1192 1193 1196 1198 1204 1205 1206 Wi-Fi Wi-Fi Wi-Fi Wi-Fi Wi-Fi Wi-Fi Wi-Fi Wi-Fi Wi-Fi Wi-Fi Update linux kernel to 2.6.27 Add Wi-Fi control to bthw Add support for BT-5630v2 and BT-5830v2 Add support for the BT-Wi-FiCARD-A AT+BWI-FIMD Control Wi-Fi Mode GPS serial port not configured su (root) login iptables warnings Configure AP mode Configure AP mode specific parameters Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 19 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.14 Version 3.8.11 – Release Notes – July 07, 2011 The 3.8.11 release is intended for MobilityPro™ Gateway (BT-5600v2 and BT-5800v2) wireless modems with or without the USB Host extension. Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Version Minimum Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version Minimum Version 2.6.21 #btw09 2.6.21 #btw03 1.2.0-btw07 1.2.0-btw02 3.0.0 3.0.0 Important Notes IPsec support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw04 or above. GRE tunnel support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw06 or above. USB Host support (MobilityPro™ Gateway only) requires kernel 2.6.21 #btw09 and u-boot 1.2.0-btw06. New Features & Improvements ID 1240 Subject BEP Description Wrong RSSI value reported in BEP events Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 20 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.15 Version 3.8.10 – Release Notes – June 20, 2011 The 3.8.10 release is intended for MobilityPro™ Gateway (BT-5600v2 and BT-5800v2) wireless modems with or without the USB Host extension. Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Version Minimum Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version Minimum Version 2.6.21 #btw09 2.6.21 #btw03 1.2.0-btw06 1.2.0-btw02 3.0.0 3.0.0 Important Notes IPsec support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw04 or above. GRE tunnel support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw06 or above. USB Host support (MobilityPro™ Gateway only) requires kernel 2.6.21 #btw09 and u-boot 1.2.0-btw06. New Features & Improvements ID 1212 1223 Subject Serial IP RF 1219 DNS 1233 1225 1235 Embedded APP GPS IO 1215 RF 1213 RF 1218 GPS 1224 1222 1228 GPS RF RF 1231 Serial IP 1234 1236 RF BEP Description Mobile Originated SIP :Add a modem ID(ESN/IMEI) as a header for each outgoing UDP packets AT+BMDIAG and AT+BNSTAT to show override SPN name instead of network name for HSPA Added framework for DNS resolving, implemented for AT+BGPSDS, AT+BRPRDS, AT+BSIPDS, and AT+BIPREG DNS support for embedded applications Add a new AT command for GPS elevation angle mask Add a new AT command to adjust IO sampling interval BT6400 Ping-keep-alive reset may keep the modem offline Add RF module reset as part of soft reset process AT+BRFPON=0 takes too long to complete for CDMA during data session No GPS fix after intensive Ignition resets Added GPS module reset process in modem warm-reset process Losing GPS UDP report to local destination at ignition start-up HSPA and CDMA RF power mode switched on/off multiple times causing modem reset Turning off HSPA modem RF power causing long delay on RF event reporting Configuring the Serial IP on poll and push mode simultaneously may cause SIP to switch to command mode WAN led remains on after Radio Power is turn off when using CDMA RF version MC5727 1.49 BEP packets to local host stopped when RF is powered off Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 21 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.16 Version 3.8.9 – Release Notes – February 15, 2011 The 3.8.9 release is intended for MobilityPro™ Gateway (BT-5600v2 and BT-5800v2) wireless modems with or without the USB Host extension. Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Version Minimum Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version Minimum Version 2.6.21 #btw09 2.6.21 #btw03 1.2.0-btw06 1.2.0-btw02 3.0.0 3.0.0 Important Notes IPsec support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw04 or above. GRE tunnel support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw06 or above. USB Host support (MobilityPro™ Gateway only) requires kernel 2.6.21 #btw09 and u-boot 1.2.0-btw06. New Features & Improvements ID Subject 1191 USB Host 1203 USB Host 1210 USB Host 1211 RF Description Add USB Host to BT-5000v2 series. The feature requires the addition of a daughter card in the modem and of a USB Type A receptacle. Add the AT+BUSBHOST=<mode> command to enable/disable and query the USB Host power Add support for USB to Serial adapters. Include drivers for the two main devices: FTDI (ftdi_sio) and Prolific (pl2303) Added workaround for Bell CDMA 01.67.01 call hangs on cold-start Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 22 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.17 Version 3.8.8 – Release Notes – December 14, 2010 Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Minimum Version Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version 2.6.21 #btw08 1.2.0-btw05 3.0.0 Minimum Version 2.6.21 #btw03 1.2.0-btw02 3.0.0 Important Notes IPsec support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw04 or above. GRE tunnel support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw06 or above. New Features & Improvements ID 646 Subject IP routing 1071 1178 Serial IP 1185 BEP 1189 IP Forwarding Description Double the number of IP forwarding ports to 40 ports (AT+BIPFWD) Add the AT+BSIPMO (Serial IP Mobile Originated settings) command to allow setting up a timer used for keeping the Serial IP connection alive. The timer is used for TCP KeepAlive timer setting or for periodically sending an empty UDP packet to keep firewalls open. When configured with a non-null timer value the modem is not waiting for data to be present on the serial port to establish a connection. Add network information to RF2 payload for GSM modems The BEP RF2 Carrier information now contains the GSM operator name (see AT+BMDIAG?) for GSM modems (GPRS/EDGE/HSPA). For CDMA modems, the field contains the programmed carrier name. Add the AT+BIPFWDI=<index>,<interface> command to set/query the interface of the incoming IP packets to forward. With this command, the modem can now perform IP forwarding on packets arriving on the Ethernet(1), USB(2) or WAN(3 - default) interface. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 23 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes Fixed Issues ID Subject 1179 LAN 1182 RF 1184 BEP 1190 RF Description DNS settings are now updated into the DHCP configuration even when it changes during a connection. DHCP lease time shall be configured for the DHCP client to get the updated DNS settings. The RF power off state (available via AT+BRFPON=0 on BT-4600A/BT-5600A, BT-6000 series, and BT-5000v2 series) is now persistent after a reboot (broken in 3.8.5). The MI3 payload was missing RF and GPS information when associated with the IGN ON trigger. RF Tx power can now be disabled via AT+BRFPON=0 on BT-6600 series and BT-5600v2 without triggering a modem reset. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 24 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.18 Version 3.8.7 – Release Notes – September 28, 2010 Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Minimum Version Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version 2.6.21 #btw07 1.2.0-btw04 3.0.0 Minimum Version 2.6.21 #btw03 1.2.0-btw02 3.0.0 Important Notes IPsec support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw04 or above. GRE tunnel support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw06 or above. Fixed Issues ID Subject 1180 WAN 1181 Events Description EvDO Rel. 0: Cannot connect in Always-on The RF Power status test intended for EvDO A modems was preventing BT-4600 and BT5600 modems to connect when in Always-on mode. Modem fails to send raw NMEA GPS using AT+BEVRPR. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 25 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.19 Version 3.8.6 – Release Notes – September 17, 2010 Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Minimum Version Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version 2.6.21 #btw07 1.2.0-btw04 3.0.0 Minimum Version 2.6.21 #btw03 1.2.0-btw02 3.0.0 Important Notes IPsec support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw04 or above. GRE tunnel support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw06 or above. Fixed Issues ID Subject 1176 AT Description In on-demand mode, requesting a manual disconnection while the modem is being disconnected due to RF conditions may cause a modem restart. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 26 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.20 Version 3.8.5 – Release Notes – September 9, 2010 Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Minimum Version Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version 2.6.21 #btw07 1.2.0-btw04 3.0.0 Minimum Version 2.6.21 #btw03 1.2.0-btw02 3.0.0 Important Notes IPsec support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw04 or above. GRE tunnel support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw06 or above. New Features & Improvements ID 956 Subject Events 1157 GPS 1161 GPS 1158 RF 1150 RF (EVDO.A) 1160 1169 RF (HSPA) Description Increase the number of configurable events (AT+BEVENT) to 63. Add the capability to log received GPS fixes (AT+BGPSLOG). When enabled, the GPS logs are part of the modem log files. Periodically save GPS odometer value in non-volatile memory independently of IGN state. Report the RF module type in ATI1. Report PRI (CDMA EvDO.A and HSPA) and PRL Region (HSPA) in ATI1. Add support for MC5728V RF module Add Sasktel and MTS to automatic HSPA configuration. Automatic GSM/EDGE/HSPA configuration occurs when the modem is reset to its factory configuration (AT&F) according to the installed SIM card. This feature may be restricted on some modems. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 27 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes Fixed Issues ID 1155 Subject AT 1156 AT 1159 AT 1162 AT 1151 1153 1165 Events Events Events 1167 Events 1154 1166 1152 1164 IP Registration IP Routing Partner Apps RF 1048 RF (HSPA) 1103 RF (HSPA) 1163 RF (HSPA) Description An incorrect IP settings in AT+BIPREG was crashing the modem Modem failed to properly close the telnet to ports 5070/6070 when the peer terminates the connection. AT+COPN? was returning ERROR since the response is too long to fit in the AT command response buffer. The results may now be obtained by issuing successive AT+COPN commands. Modem may restart randomly when AT+BMDIAG? is automatically issued at very high frequency. Legacy modems (BT-4000/BT-5000) had an invalid device ID in BEP messages. AT command response was restricted to short strings. Reduce latency to send first BEP message IMOM (Initial Mobile Originated Management) Server errors are logged too frequently. IMOM connection to a remote server is now only attempted every 30 minutes. The IP registration message sent by GSM modems had an extra white space. Incorrect LAN routing when in On-Demand mode and not connected to WAN. The application was occasionally failing to start. Add WD to recover from a failure to connect in on-demand mode. Show the HSPA packet session status in the RF state of AT+BMDIAG? and AT+BNSTAT? of HSPA modems. Re-enabling the HSPA RF module transmit (AT+BRFPON=1) is no longer triggering a modem reset. Modem to report only the RSSI of the active cell (HSPA). Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 28 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.21 Version 3.8.4 – Release Notes – June 7, 2010 Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Minimum Version Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version 2.6.21 #btw07 1.2.0-btw04 3.0.0 Minimum Version 2.6.21 #btw03 1.2.0-btw02 3.0.0 Important Notes IPsec support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw04 or above. GRE tunnel support (IndustrialPro™ and MobilityPro™ Gateway only) requires kernel 2.6.21 #btw06 or above. New Features & Improvements ID Subject 1023 Modem Time 1042 GRE Tunnels 1043 GPS 1044 GPS 1116 Events 1117 Events 1118 Events 1142 Security Description Synchronize modem time on NTP, GPS or CELL Add the AT+BMTIME command to select the time source, the AT+BNTP to select NTP servers and the AT+BNTPST command to monitor the NTP client. GRE Tunnel support Add the AT+BGRETUN, AT+BGREOPT, AT+BGREKEY, AT+BGREMR, AT+BGREDI, AT+BMCASTR, AT+BSROUTE AT commands to support GRE tunneling. This feature is available on BT-6000 and BT-5600v2/BT-5800v2 only with kernel 2.6.21 btw#06 or above. Specific NMEA sentence mask per destination The AT+BGPSRP allows to set a specific NMEA message mask per GPS destination (IP1, IP2 and Serial). Specific reporting timer per destination The AT+BGPSRP allows to set a specific reporting timer per GPS destination (IP1, IP2 and Serial). Add capability to log BEP events (AT+BEVLOG). Add capability to purge stored BEP events (AT+BSFMRM=1) Note: The modem needs to be reset once the command is issued. Report Store and Forward memory status (AT+BSFMST?) The AT+BSFMST? command reports the number of used and free memory blocks as well as the number of stored events per BEP destination. Serial port AT command protection Access to AT command can now be password protected the same way as access from LAN and/or WAN with the AT+BRPSWD command. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 29 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.22 Version 3.8.3 – Release Notes – February 18, 2010 Dependencies Unchanged from 3.8.0, see below. Fixed Issues ID Subject 1113 IP pass-through Description Occasionally, when first acquiring the WAN IP address or when the WAN IP address gets re-negotiated, the modem may fail to configure the interface assigned to IP passthrough with the WAN IP until the modem resets. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 30 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.23 Version 3.8.2 – Release Notes – February 12, 2010 Dependencies Unchanged from 3.8.0, see below. New Features & Improvements ID Subject 1053 HSPA Description HSPA automatic configuration When the modem is reset to factory configuration (AT&F or Action > Reset Modem in BVDM), the connection dial string, username, password and APN are automatically set according to the SIM card settings. Fixed Issues ID 1032 1037 1039 1092 1097 1098 1099 1102 1107 1108 Subject Serial port Events Serial IP RF RF RF Configuration RF AT Configuration Description Serial port not reset to configuration settings after BVDM disconnects. AT+BEVGSS syntax should be verified IP->Serial and Serial->IP values inverted in SIP diag EVDO A modems may fail to connect (Verizon and Sprint only). WAN LED does not blink to indicate WAN activity Modem failed to log RF Diagnostic information (DM) in QxDM Modem looses its password after upgrade HSPA: Manual network selection (+COPS) is missing parameter Frequent +BMDIAG/+BNSTAT resets modem Firmware upgrade sets MTU to zero Known issues Unchanged from 3.8.0, see below. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 31 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.24 Version 3.8.1 – Release Notes – January 11, 2010 Dependencies Unchanged from 3.8.0, see below. Fixed Issues ID 1082 1087 1089 1088 1092 1090 1100 Subject AT Events Events RF RF Startup Startup Description Frequent connections/disconnections from telnet AT commands reset modem. MI2 and MI3 PRL and GPS version fields are missing for some modem models. Information is missing in initial ignition ON BEP message. BT-6400 series modems fail to report EDGE service when available. EVDO A modems may fail to connect (Verizon and Sprint only). Improve hardware verification (Ethernet and USB) at modem startup. Improve cold weather modem startup. Known issues Unchanged from 3.8.0, see below. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 32 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 3.25 Version 3.8.0 – Release Notes – December 18, 2009 Dependencies Kernel Boot Loader File System Legacy modems BT-4000 / BT-5000 Series Current Minimum Version Version 2.6.15.1bt5 2.6.15.1bt5 1.1.3bt10 1.1.3bt8 3.0.0 2.0.0 IndustrialPro™ and MobilityPro™ Gateway BT-5000v2 / BT-6000 Series Current Version 2.6.21 #btw06 1.2.0-btw04 3.0.0 Minimum Version 2.6.21 #btw022 1.2.0-btw02 3.0.0 Important Notes Release 3.6.2 added IPsec functionality to the BT-5000v2 and BT-6000 series modems. If upgrading from a version prior to 3.6.2, an advanced upgrade is necessary to enable IPsec support. New Features & Improvements ID 674 Subject Firmware upgrade 1014 Events 1015 Events 1017 Events 1018 Events 1019 Events 1027 GPS Description Modem initiated upgrade package download The AT+BWGET can be used to download an upgrade package from an FTP or HTTP site. WAN event added to BEP The WAN event (see AT+BEVENT) can be used to signal when the modem has a WAN IP address and when it changes. Modem Originated Management Destination type 3 (MOM) can now be used to initiate management action from the modem. See AT+BRPRDS/AT+BEVRPR/AT+BEVENT. This feature is meant to operate with BlueVue Group (release 2.1.80) Add new BEP payloads: MI2, MI3, RF2, IP1 Those new message payloads can be used to report status information to a management server. Add new BEP payload: AU1 This new BEP payload can be used authenticate BEP messages. Add new BEP payload: AC1 This new BEP payload can be used to exchange AT commands and responses between a management server (BVG) and the modem. Synchronize modem time on GPS: AT+BGPSDT 2 The “minimum” kernel version of 2.6.21 #btw02 does not support IPsec. If IPsec is required, an advanced upgrade should be performed to upgrade the kernel to 2.6.21 #btw04 or above. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 33 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes Fixed Issues ID 1028 1035 1040 1054 1055 Subject Serial IP IPSEC RF FTP DHCP 1056 GPS/Events 1057 1073 1077 1079 1080 RF AT GPS UDP RF Description Modem fails to transfer files via Serial IP AT+BIPSSN? does not display the remote subnet configuration RF diagnostic pass-through via serial fails The FTP server was failing when enabled multiple times. In IP pass-through, the DHCP lease time is reduced to 30 seconds until the WAN IP is available and assigned to the local interface. The configured DHCP lease time is then used. GPS/BEP UDP destinations connects/disconnects every 30 seconds This occurred when +BSYNC was used and no ACK messages were received. HSPA: Intermittent high latency and ping packet loss AT+BIPINF returns ERROR GPS fix not reported Intermittent high latency and loss of UDP packets HSPA: MCC reported instead of MNC Known Issues ID 917 Subject Activation 880 Activation 966 WAN LED Description New modems on Sprint now utilize OMA-DM instead of IOTA for provisioning, resulting in an error when the AT!IOTASTART command is issued. OMA-DM can be started with AT!dmdc=2 instead. This change requires BlueVue Device Manager 1.7.9 for automatic activation. A bug in the Sierra Wireless MC5727 module returns ERROR during activation when in fact the activation may have been successful. A workaround is available in BlueVue Device Manager 1.7.9. The WAN LED on BT-5800v2 and BT-6800 series may not indicate the connection status when the RF Transmit has been disabled and then re-enabled using AT+BRFPON. This issue only exists with RF module firmware: K1_0_2_8AP. Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 34 IndustrialPro™ and MobilityPro™ Gateway Wireless Modems BT Series Firmware Release Notes 4 Support Information Visit the Industrial Wireless Product Support section of Sixnet website to download product manuals, software updates and modem firmware updates. US & Canada +1-877-432-9908 International +1-518-877-5173 Email [email protected] http://www.redlion.net Website Sixnet, Inc. 331 Ushers Road, Ballston Lake, NY 12019 FLEXIBLE. RELIABLE. POWERFUL. T +1 518 877 5173 F +1 518 877 8346 www.sixnet.com Version 3.8.20 / 3.9.7 © 2015. Sixnet. All Rights Reserved. 35