LANEUW SERIES
4:1 Ultra Wide Input Voltage Ranges
Single & Dual Outputs
High Power Density in 9-Pin SIP Package
2 Watt DC/DC Power Converters
FEATURES
• RoHS Compliant
• Single & Dual Fully Regulated Outputs
• UL 94V-0 Compliant
• Remote ON/OFF Control
• High Power Density in 9-Pin SIP Package
• 1500VDC I/O Isolation
• 2 Watts Output Power
• High Efficiency up to 80%
• Small Footprint: 1.02” x 0.36” x 0.49”
• -40°C to +85°C Operating Temperature Range
• 4:1 Ultra Wide Input Voltage Ranges
• Over Load Protection
DESCRIPTION
The LANEUW series consists of isolated 2 Watt DC/DC power converters with fully regulated single and dual
outputs and ultra wide 4:1 input voltage ranges of 9~36VDC and 18~75VDC. These converters operate over a
temperature range of -40°C to +85°C while maintaining all specifications. The LANEUW series is RoHS
compliant and includes remote on/off control, 1500VDC I/O isolation, and over load protection. These converters
are housed in a 9-pin SIP package with a very small footprint occupying only 0.36in2 on the PCB. The very
compact dimensions of these DC/DC converters make them an ideal solution for many space critical applications
in battery-powered equipment and instrumentation.
04/16/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 1 of 7
LANEUW Series
Single and Dual Outputs
4:1 Ultra Wide Input Range
2 Watt DC/DC Power Converters
Rev. B
SPECIFICATIONS: LANEUW SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
9
18
-0.7
-0.7
4.5
8.5
24
48
36
75
50
100
8.5
17
8
16
Unit
INPUT SPECIFICATIONS
Input Voltage Range
Input Surge Voltage (1s max.)
Start-up Voltage
Under Voltage Shutdown
24VDC nominal input models
48VDC nominal input models
24VDC nominal input models
48VDC nominal input models
24VDC nominal input models
48VDC nominal input models
24VDC nominal input models
48VDC nominal input models
6
12
Input Current
Reflected Ripple Current (Page 5)
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
Internal Power Dissipation
OUTPUT SPECIFICATIONS
Output Voltage
Line Regulation
Load Regulation
Output Voltage Accuracy
Output Voltage Balance
Output Power
Output Current
Minimum Load (Note 1)
Ripple & Noise (20MHz) (Page 5)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
PROTECTION
Short Circuit Protection
Input Fuse (Note 2)
GENERAL SPECIFICATIONS
Efficiency
Switching Frequency
Isolation Voltage (Input to Output)
Isolation Resistance
Isolation Capacitance
Maximum Capacitive Load
REMOTE ON/OFF (Page 5)
Converter On
Negative Logic
Converter Off
Stand-by Input Current
On
Control Input Current
Off
Control Common
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature Range (with derating)
Case Temperature
Storage Temperature
Humidity (non-condensing)
Cooling
Lead Temperature
MTBF (calculated)
PHYSICAL SPECIFICATIONS
Weight
Dimensions (L x W x H)
Case Material
Flammability
04/16/2012
VDC
VDC
VDC
VDC
See Table
24VDC nominal input models
48VDC nominal input models
300
600
mA
0.5
1500
Capacitor Type
2500
See Table
±0.3
±0.5
±0.5
±0.75
±1.0
±2.0
±1.0
±2.0
2
See Table
See Table
30
50
75
15
Low line to high line at full load
25% to 100% full load
Full load an nominal Vin
Dual Outputs, Balanced loads
Over line, load, and temperature
Measured to within 1% error band for a step change in output
load from 75% to 100%
25% load step change
mW
%
%
%
%
W
mVp-p
mVp-p
mVrms
100
300
µs
±3
±0.01
±5
±0.02
%
%/°C
continuous
350mA slow-blow type
135mA slow-blow type
24VDC nominal input models
48VDC nominal input models
Nominal input voltage and full load
See Table
300
60 seconds
500VDC
A
mW
1500
1000
250
500
KHz
VDC
MΩ
pF
See Table
Nominal Vin
Vin = 0V
Vin = 5.0V
ambient
Under 6.0VDC or open circuit, drops down to 0VDC by 2mV/°C
2.9 to 15VDC
1
3
mA
-1
mA
1
Referenced to negative input
-40
-55
1.5mm from case for 10 seconds
MIL-HDBK-217F at 25°C, Ground Benign
1,000,000
+85
+90
+105
95
Free air convection
260
°C
°C
°C
% RH
°C
hours
0.23oz (6.5g)
1.02 x 0.36 x 0.49 inches (25.95 x 9.25 x 12.45 mm)
Non-conductive black plastic
UL 94V-0 rated
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 2 of 7
LANEUW Series
Single and Dual Outputs
4:1 Ultra Wide Input Range
2 Watt DC/DC Power Converters
Rev. B
MODEL SELECTION TABLES
SINGLE OUTPUT MODELS
Model Number
Input Voltage
LANEUW2433R
LANEUW2405R
24 VDC
(9 – 36 VDC)
Output Current
Output
Voltage
Min
3.3 VDC
125mA
500mA
5 VDC
100mA
400mA
(1)
Max
Input Current
No Load Max Load
Reflected Ripple
Current (Typ)
97mA
110mA
20mA
Output
Power
Efficiency
Max Capacitive
Load
1.65W
71%
2200μF
2W
76%
1000μF
300mA
12 VDC
42mA
167mA
106mA
2W
79%
170μF
LANEUW2415R
15 VDC
33mA
134mA
105mA
2W
80%
110μF
LANEUW4833R
3.3 VDC
125mA
500mA
49mA
1.65W
70%
2200μF
5 VDC
100mA
400mA
2W
72%
1000μF
LANEUW2412R
LANEUW4805R
LANEUW4812R
48 VDC
(18 – 75 VDC)
LANEUW4815R
58mA
15mA
600mA
12 VDC
42mA
167mA
54mA
2W
78%
170μF
15 VDC
33mA
134mA
54mA
2W
78%
110μF
Output
Power
Efficiency
Max Capacitive
Load
2W
73%
±470μF
2W
77%
±100μF
DUAL OUTPUT MODELS
Output Current
Input Current
Output
Voltage
Min(1)
Max
±5 VDC
±50mA
±200mA
±12 VDC
±21mA
±83mA
LANEUW2415RD
±15 VDC
±17mA
±67mA
106mA
2W
79%
±47μF
LANEUW4805RD
±5 VDC
±50mA
±200mA
60mA
2W
70%
±470μF
±12 VDC
±21mA
±83mA
2W
76%
±100μF
±15 VDC
±17mA
±67mA
2W
76%
±47μF
Model Number
Input Voltage
LANEUW2405RD
LANEUW2412RD
LANEUW4812RD
LANEUW4815RD
24 VDC
(9 – 36 VDC)
48 VDC
(18 – 75 VDC)
No Load Max Load
Reflected Ripple
Current (Typ)
114mA
20mA
15mA
108mA
55mA
300mA
600mA
55mA
NOTES
1. These power converters require a minimum output loading to maintain all specified regulations. Operation under no-load
conditions will not damage these devices; however, they may not meet all the listed specifications.
2. All DC/DC converters should be externally fused at the front end for protection.
*Due to advances in technology, specifications are subject to change without notice.
04/16/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 3 of 7
Rev. B
LANEUW Series
Single and Dual Outputs
4:1 Ultra Wide Input Range
2 Watt DC/DC Power Converters
DERATING CURVE
MECHANICAL DRAWING
04/16/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 4 of 7
Rev. B
LANEUW Series
Single and Dual Outputs
4:1 Ultra Wide Input Range
2 Watt DC/DC Power Converters
TEST CONFIGURATIONS
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with an inductor Lin (4.7µH) and Cin (220µF, ESR < 1.0Ω at 100 KHz)
to simulate source impedance. Capacitor Cin offsets possible battery impedance.
Current ripple is measured at the input terminals of the module. Measurement bandwidth is 0-500 KHz.
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement
bandwidth is 0-20MHz. Position the load between 50mm and 75mm from the DC/DC Converter.
DESIGN & FEATURE CONSIDERATIONS
Remote On/Off
Negative logic remote on/off turns the module OFF during a logic high voltage on the remote on/off pin and ON
during a logic low. To turn the module ON and OFF, the user must supply a switch to control the voltage between
the on/off terminal and the –Vin terminal. The switch can be an open collector or equivalent. A logic high is 2.9V
to 15V. A logic low is under 0.6VDC or open circuit, drops down to 0VDC by 2mV/°C. The maximum sink current
at on/off terminal during a logic low is 1mA. The maximum allowable leakage current of the switch at on/off
terminal = (under 0.6VDC or open circuit) is 1mA.
Maximum Capacitive Load
The LANEUW series has a limitation of maximum connected capacitance on the output. The power module may
be operated in current limiting mode during start-up, affecting the ramp-up and the start-up time. The maximum
capacitance can be found in the model selection tables.
Over Current Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting
circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit
shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
04/16/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 5 of 7
Rev. B
LANEUW Series
Single and Dual Outputs
4:1 Ultra Wide Input Range
2 Watt DC/DC Power Converters
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances
can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a
capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good
quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of 1.5µF for the 24V and 48V input
devices.
Output Ripple Reduction
A good quality low ESR capacitor placed as close as possible across the load will give the best ripple and noise
performance. To reduce output ripple, it is recommended to use 3.3µF capacitors at the output.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module,
and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power
module, the case temperature must be kept below 90°C. The derating curves are determined from measurements
obtained in a test setup.
04/16/2012
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 6 of 7
Rev. B
LANEUW Series
Single and Dual Outputs
4:1 Ultra Wide Input Range
2 Watt DC/DC Power Converters
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working
closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to
provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss
your future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
04/16/2012
(603)778-2300
(888)587-9255
(603)778-9797
[email protected]
www.wallindustries.com
5 Watson Brook Rd.
Exeter, NH 03833
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797