Eclipse® Model 706 High Performance Guided Wave Radar Level Transmitter DESCRIPTION Measures Level, Interface, Volume, and Flow The Eclipse® Model 706 High Performance Transmitter is a loop-powered, 24 VDC level transmitter that is based upon the proven and accepted technology of Guided Wave Radar (GWR). Encompassing a number of significant engineering accomplishments, this leading edge level transmitter is designed to provide measurement performance well beyond that of many of the more traditional technologies. Utilizing “diode switching” technology, along with the most comprehensive probe offering on the market, this single transmitter can be used in a wide variety of applications ranging from very light hydrocarbons to waterbased media. The innovative angled, dual compartment enclosure is now a common sight in the industry. This enclosure, first brought to the industry by Magnetrol® in 1998, is angled to maximize ease of wiring, configuration, and viewing of the versatile graphic LCD display. One universal Model 706 transmitter can be used and interchanged with all probe types, and offers enhanced reliability as it is certified for use in critical SIL 2 hardware safety loops. The ECLIPSE Model 706 supports both the FDT/DTM and Enhanced DD (EDDL) standards, which allow viewing of valuable configuration and diagnostic information such as the echo curve in tools such as PACTware ™, AMS Device Manager, and various HART ® Field Communicators. APPLICATIONS MEDIA: Liquids, solids, or slurries; hydrocarbons to waterbased media (Dielectric Constant εr = 1.2–100) VESSELS: Most process or storage vessels up to rated probe temperature and pressure. Eclipse® Model 706 DTM CONDITIONS: All level measurement and control applications including process conditions exhibiting visible vapors, foam, surface agitation, bubbling or boiling, high fill/empty rates, low level and varying dielectric media or specific gravity. FEATURES • Multivariable, two-wire, 24 VDC loop-powered transmitter for level, interface, volume, or flow. • Diode switching technology offers best-in-class signal strength and signal-to-noise ratio (SNR) resulting in enhanced capability in difficult low dielectric applications. • Level measurement not affected by changing media characteristics. • No need to move levels for calibration. • Overfill Capable probes allow for “true level” measurement all the way up to the process seal, without the need for special algorithms. • 4-button keypad and graphic LCD display allow for convenient viewing of configuration parameters and echo curve. • Proactive diagnostics advise not only what is wrong, but also offer troubleshooting tips. • Nine common tank shapes for volumetric output. • 30-point custom strapping table for uncommonlyshaped tanks. • Two standard flumes and four standard weirs of various sizes for flow measurement. • Generic flow equation for non-standard channels. • 360° rotatable housing can be separated from probe without depressurizing the vessel. • Probe designs up to +850 °F/6250 psi (+450 °C/431 bar). • Saturated steam applications up to 3000 psi (207 bar), +750 °F (+400 °C) when installed in side-mounted chamber. • Cryogenic applications down to -320 °F (-196 °C). • Transmitter can be remote-mounted up to 12 feet (3.6 m) away from the probe. • FMEDA certification allows use in SIL 2 Loops • No moving parts. • FOUNDATION fieldbus™ and Modbus digital outputs. TECHNOLOGY PRINCIPLE OF OPERATION ECLIPSE Guided Wave Radar is based upon the technology of TDR (Time Domain Reflectometry). TDR utilizes pulses of electromagnetic energy transmitted down a wave guide (probe). When a pulse reaches a surface that has a higher dielectric constant than the air (εr = 1) in which it is traveling, a portion of the pulse is reflected. The transit time of the pulse is then measured via high speed timing circuitry that provides an accurate measure of the liquid (or solids) level. The amplitude of the reflection depends on the dielectric constant of the product. The higher the dielectric constant, the larger is the reflection. Initial Pulse Initial Pulse Reflected Pulse Air Liquid εr = 1 Air εr = 1 εr > 1.2 Reflected Pulse εr > 1.2 Transmitted Pulse Transmitted Pulse Overall Liquid Level Bulk Solid Level INTERFACE MEASUREMENT The ECLIPSE Model 706 is capable of measuring both an upper liquid level and an interface liquid level. As only a portion of the pulse is reflected from a low dielectric upper surface, some of the transmitted energy continues down the GWR probe through the upper liquid. The remaining initial pulse is again reflected when it reaches the higher dielectric lower liquid. It is required that the upper liquid has a dielectric constant less than 10, and the lower liquid has a dielectric constant greater than 15. A typical interface application would be oil over water, with the upper layer of oil being non-conductive (εr ≈ 2.0), and the lower layer of water being very conductive (εr ≈ 80). The thickness of the upper layer could be as small as 2" (50 mm) while the maximum upper layer is limited to the length of the GWR probe. 2 Reference Signal Air εr = 1 Upper level signal Low dielectric medium (e.g. oil, εr = 2) Emulsion Interface level signal High dielectric medium (e.g. water, εr = 80) Time Interface Level SPECIAL APPLICATIONS EMULSION LAYERS OVERFILL CAPABILITY As emulsion layers, also called “rag layers,” can decrease the strength of the reflected signal in an interface application, GWR transmitters are typically recommended for applications that have clean, distinct layers. Although agencies like WHG or VLAREM certify Overfill proof protection, defined as the tested, reliable operation when the transmitter is used as overfill alarm, it is assumed in their analysis that the installation is designed in such a way that the vessel or side mounted cage cannot physically overfill. However, the ECLIPSE Model 706, with its powerful internal measurement algorithms, will tend to detect the top of an emulsion layer. Contact the factory for application assistance regarding emulsion layers in your specific application. SATURATED STEAM APPLICATIONS (Boilers, Feedwater Heaters, etc.) As the temperature of a saturated steam application increases, the dielectric constant of the steam vapor space also increases. This increase in vapor space dielectric causes a delay in the GWR signal propagation as it travels down the probe, causing the liquid level to appear lower than actual. The ECLIPSE Model 706 transmitter and Model 7yS Coaxial Steam probe provide a unique solution to this application. The effects of the changing steam conditions can be compensated for by utilizing a mechanical steam target placed inside and near the top of the Model 7yS coaxial probe. NOTE: The measurement error associated with this propagation delay does depend on temperature and is a function of the square root of the vapor space dielectric constant. For example, with no compensation, a +450 °F (+230 °C) application would show a level error of about 5.5%, while a +600 °F (+315 °C) application would show an error approaching 20%! However, there are practical applications where a GWR probe can be completely flooded with level all the way up to the process connection (face of the flange). Although the affected areas are application dependent, typical GWR probes have a transition zone (or possibly dead zone) at the top of the probe where interacting signals can either affect the linearity of the measurement or, more dramatically, result in a complete loss of signal. While some manufacturers of GWR transmitters may use special algorithms to “infer” level measurement when this undesirable signal interaction occurs and the actual level signal is lost, the ECLIPSE Model 706 offers a unique solution by utilizing a concept called Overfill Safe Operation. An Overfill safe probe is defined by the fact that it has a predictable and uniform characteristic impedance all the way down the entire length of the waveguide (probe). These probes allow the ECLIPSE Model 706 to measure accurate levels up to the process flange without any nonmeasurable zone at the top of the GWR probe. Overfill safe GWR probes are unique to ECLIPSE GWR, and coaxial probes can be installed at any location on the vessel. Overfill safe probes are offered in a variety of Coaxial and Caged designs. Knowing exactly where the target is located at room temperature, and then continuously monitoring its apparent location, the vapor space dielectric can be back-calculated. Knowing the vapor space dielectric, accurate compensation of the actual liquid level reading is accomplished. This is a patented technique with two US Patents (US 6642801 and US 6867729) issued for both the mechanical target concept and the associated software algorithm. Contact the factory for additional information relating to saturated steam applications. 3 PROBE THREE OVERVIEW STYLES OF GWR PROBES With one basic ECLIPSE Model 706 transmitter that operates with all probes, choosing the proper Guided Wave Radar (GWR) probe is the most important decision in the application process. The probe configuration establishes fundamental performance characteristics. All ECLIPSE Model 706 probes can be described by three basic configurations: • Coaxial Each of these probe configurations has specific strengths and weaknesses. Although there can be overlap, and different probes can certainly be used in similar applications, it is important to understand their basic differences so that one can choose the probe type that will offer optimal performance. The descriptions below are facts relating to the physics of GWR technology and are not specific to the ECLIPSE Model 706. • Twin flexible cable • Single element (rigid rod or flexible cable) COAXIAL PROBES BASIC —FOR CLEAN LIQUIDS The coaxial probe is the most efficient of all GWR probe configurations and should be the first consideration in all applications. Analogous to the efficiency of coaxial cable, a coaxial probe allows almost unimpeded movement of the high frequency pulses throughout its length. The basic 0.875" (22.5 mm) diameter coaxial GWR probe is only recommended for use in clean applications or special applications such as saturated steam. Teflon®, PEEK, or alumina spacers centering the inner rod within the outer tube are located at 24" (60 cm) intervals, resulting in a perfect characteristic impedance along the entire length of the probe. The electromagnetic field that develops between the inner rod and outer tube is completely contained and uniform down the entire length of the probe. See Figure 1. This means that the coaxial probe is immune to any proximity affects from other objects in the vessel, and therefore, in essence, it can be used anywhere that it can mechanically fit. The efficiency and overall sensitivity of a coaxial configuration yields robust signal strength, even in extremely low dielectric (εr ≥1.4) applications. The sensitivity of this “closed” design, however, also makes it more susceptible to measurement error in applications that can have coating and buildup. All ECLIPSE Model 706 coaxial probes are Overfill Safe as standard, by design. Figure 1 Coaxial Probe 4 This probe is recommended in applications with viscosities up to 500 cP (mPa.s) maximum. ENLARGED—FOR DIFFICULT LIQUIDS The standard Enlarged 1.75" (45 mm) or 1.93” (49mm) diameter coaxial GWR probes can be generally used for most applications. They can be installed directly into the tank as well as into bypass cages, stillwells or bridles. The robust construction reduces the number of spacers required, allowing the probe to be used in applications where higher risk of buildup exists. To further reduce the possibility of media buildup, the use of a single bottom spacer is recommended up to probe lengths of 100 inches (2.54 meters). The overall sensitivity and performance of an enlarged coaxial GWR probe is identical to a standard coaxial GWR probe, but it offers the very important advantage that it can be used in applications with viscosities up to 2,000 cP (mPa.s). PROBE THREE OVERVIEW STYLES OF CONTINUED GWR PROBES OPTIONAL FLUSHING CONNECTION The maintenance of coaxial GWR probes in applications suffering from buildup or crystallization can be significantly improved by using an optional flushing connection. This flushing connection is a metal extension with a port welded above the process connection. The port allows the user to purge the inside of the coaxial GWR probe during routine maintenance. Note: The best approach to eliminate the effects of condensation or crystallization is to install adequate insulation or heat tracing (steam or electrical). A flushing connection is no substitute for proper maintenance, but will help to reduce the frequency of the intervention. Flushing Port Shown Plugged (1⁄4" NPT-F) CAGED—FOR DIRTY LIQUIDS Unique to MAGNETROL, the Caged GWR probe is a single rod probe which uses an existing or new cage, bridle, or stillwell as the second conductor to re-create the same signal propagation as a coaxial GWR probe. Caged GWR probes are designed for 2" (DN50), 3" (DN80) or 4" (DN100) diameter metal chambers, and utilize a specially designed impedance matching section that results in the same overall characteristic impedance of a coaxial style GWR probe. Caged GWR probes offer the same sensitivity and performance as coaxial GWR probes, but the single conductor design allows it to be used in applications with viscosities up to 10,000 cP (mPa.s). OPTIONAL ANNUNCIATOR FITTING High Pressure and High Temperature High Pressure ECLIPSE Model 706 probes containing a glass ceramic alloy process seal (Models 7yD, P, J, L, M and N) are available with an optional annunciator fitting. The use of this fitting complies with the Dual Seal requirements of ANSI/ISA-12.27.01-2011, titled “Requirements for Process Sealing between Electrical Systems and Flammable or Combustible Process Fluids,” which require the incorporation of a method that indicates or annunciates a primary seal failure (e.g., visible leakage, an audible whistle, or other means of monitoring). 5 PROBE THREE OVERVIEW STYLES OF CONTINUED GWR PROBES TWIN CABLE FLEXIBLE PROBES The relationship of the Twin Cable probe design to a coaxial probe design is similar to that of older, twin-lead, antenna lead-in to modern, coaxial cable. 300-ohm twinlead cable simply does not have the efficiency of 75-ohm coaxial cable, making the parallel conductor design less sensitive than the concentric coaxial. See Figure 2. This translates into Twin Cable GWR probes having the ability to measure dielectrics down to εr ≥1.7. Figure 3 shows the single element design and how the electromagnetic pulse effectively expands into a teardrop shape as it propagates away from the top of the tank (the inherent ground reference). This single element configuration (rod or cable) is the least efficient of the three probe types, but can still operate with a minimum dielectric detection of approximately εr > 1.7 in an open, nonmetallic vessel. Heavy bridging of material between the cables across the FEP coating can cause improper measurement and should be avoided. However, this dielectric constant performance improves considerably (εr > 1.4) when the single rod probe is installed in a metal cage/bridle, or mounted 2–6" (50 –150 mm) away from a metal tank wall. Because the design is “open,” it exhibits two strong tendencies: Figure 2 also shows that, although most of the electromagnetic field develops between the two cables, there is also some peripheral energy that expands outward, making the Twin Cable probe more sensitive to proximity effects of objects located immediately around it. For that reason, it is recommended to keep the active element of the Twin Cable probe at least 1 inch (25 mm) away from metal objects. Figure 2 Twin Flexible Probe • It is the most forgiving of coating and buildup. (The PFA-insulated probe is the best choice for severe buildup and coating). • It is most affected by proximity issues. It is important to note that a parallel metal wall INCREASES the performance of a single rod probe while a singular, metal object protruding out near the probe may be improperly detected as a liquid level. These tendencies are application/installation dependent. Therefore, by properly matching the single rod probe to a cage/chamber, the ECLIPSE Model 706 broad offering of caged probes combines the performance/sensitivity advantages of a coaxial probe and the viscosity immunity of a single rod probe. The Caged Probes are Overfill Safe by design, can be used in interface and other difficult, low dielectric applications, and are unique to MAGNETROL and the ECLIPSE Model 706. Contact the factory for additional support and questions. SINGLE ROD PROBES Single element GWR probes act quite differently than both coaxial and twin cable designs. With only one conductor to work with, the pulses of energy develop between the single rod probe and the mounting nut or flange. In other words, the pulse propagates down and around the rod as it references its ground at the top of the tank. The energy and efficiency of the pulse are directly related to how much metallic surface exists around it at the top of the vessel. This metallic surface at the top of the probe is called the “launch plate.” The larger the launch plate, the more efficient the signal propagation down the probe. 6 Figure 3 Single Rod Probe Launch Plate PROBE SELECTION COAXIAL/CAGED GWR PROBE GUIDE TWIN CABLE GWR PROBE signal propagation SINGLE ROD/CABLE PROBE signal propagation signal propagation La end view GWR Description Probe¿ 7yT 7yP 7yD 7yS 7yG 7yL 7yJ 7yF 7yM 7yN Application end view Installation Dielectric Range ¡¬ Temperature Range √ Max. Overfill Vacuum ƒ Pressure Safe Viscosity cP (mPa.s) Coaxial GWR Probes—Liquids Standard Level/Interface Tank/Chamber ε 1.4–100 -40 to +400 °F r Temperature (-40 to +200 °C) High -320 to +400 °F ε 1.4–100 (-196 Pressure Level/Interface Tank/Chamber r to +200 °C) High Temp./ Level/Interface Tank/Chamber ε 1.4–100 -320 to +850 °F r High Press. (-196 to +450 °C) Steam Saturated to +750 °F ≈ Tank/Chamber εr 10–100 -40 Probe Steam (-40 to +400 °C) 1000 psi (70 bar) 6250 psi (431 bar) 6250 psi (431 bar) 3000 psi (207 bar) Yes Yes 500/2000 Full Yes 500/2000 Full Yes 500/2000 Full No ∆ 500 Standard Temperature Level/Interface High Pressure Level/Interface High Temp./ Level/Interface High Press. Caged GWR Probes— Liquids -40 to +400 °F εr 1.4–100 (-40 Chamber to +200 °C) -320 to +400 °F εr 1.4–100 (-196 to Chamber +200 °C) -320 to +850 °F εr 1.4–100 (-196 to +450 Chamber °C) 1000 psi (70 bar) 6250 psi (431 bar) 6250 psi (431 bar) Yes Yes 10000 Full Yes 10000 Full Yes 10000 Standard Temperature High Pressure High Temp./ High Press. Single Rod Rigid GWR Probes—Liquids -40 to +400° F 1000 psi εr 1.7–100 (-40 Tank to +200° C) (70 bar) -320 to +400° F 6250 psi εr 1.7–100 (-196 to Tank +200 °C) (431 bar) -320 to +850 °F 6250 psi εr 1.7–100 (-196 to +450 Tank °C) (431 bar) Yes No « 10000 Full No « 10000 Full No « 10000 Yes No « 10000 Full No « 10000 Yes No « 10000 Full No « 10000 Level Level Level Standard 7y1 Temperature Level High 7y3 Level Pressure Standard 7y4➈ Temperature Level/Interface Temp./ 7y6 High High Press Level/Interface Single Cable Flexible GWR Probes—Liquids -40 to +400 °F 1000 psi εr 1.7–100 (-40 Tank to +200 °C) (70 bar) -320 to +400 °F 6250 psi εr 1.7–100 (-196 to Tank +200 °C) (431 bar) -40 to +400 °F 1000 psi εr 1.4–100 (-40 to +200 °C) Chamber (70 bar) -320 to +850 °F 6250 psi εr 1.4–100 (-196 to +450 °C) (431 bar) Chamber 7y7 Standard Temperature Level/Interface Twin Cable Flexible GWR Probes— Liquids -40 to +400 °F 1000 psi εr 1.7–100 (-40 Tank to +200 °C) (70 bar) Yes No « 1500 7y2 Bulk Solids Probe Level Single Cable Flexible GWR Probes—Solids -40 to +150 °F Atmos. εr 4–100 (-40 Tank to +65 °C) No No « 10000 Level Twin Cable Flexible GWR Probes—Solids -40 to +150 °F Atmos. εr 1.7–100 (-40 Tank to +65 °C) No No « 1500 7y5 Bulk Solids Probe ¿ 2nd digit A=English, C=Metric ¡ Minimum εr 1.2 with end of probe analysis enabled. ¬ Single rod probes mounted directly into the vessel must be within 3– 6 inches of metal tank wall to obtain minimum dielectric of 1.4, otherwise r min = 1.7. √ Depends on the probe spacer material. Refer to Model Selection for spacer options. ƒ ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seals are hermetically sealed to <10-8 cc/sec @ 1 atmosphere helium. ε ≈ ∆ « ➈ When installed in side-mounted chamber. Consult factory for overfill applications. Overfill capability can be achieved with software. Scheduled for future release. 7 TRANSMITTER SPECIFICATIONS FUNCTIONAL/PHYSICAL System Design Measurement Principle Guided Wave Radar based on Time Domain Reflectometry (TDR) Input Measured Variable Level, as determined by GWR time of flight Span 6 inches to 100 feet (15 cm to 30 m); Model 7yS Probe 20 feet (610 cm) max. Output Type 4 to 20 mA with HART: 3.8 mA to 20.5 mA useable (per NAMUR NE43) FOUNDATION fieldbus™: H1 (ITK Ver. 6.1.1) Modbus Resolution Analog: Digital Display: .003 mA 1 mm Loop Resistance 591 ohms @ 24 VDC and 22 mA Diagnostic Alarm Selectable: 3.6 mA, 22 mA (meets requirements of NAMUR NE 43), or HOLD last output Diagnostic Indication Meets requirements of NAMUR NE107 Damping Adjustable 0–10 seconds User Interface Keypad 4-button menu-driven data entry Display Graphic liquid crystal display Digital Communication/Systems HART Version 7—with Field Communicator, FOUNDATION fieldbus, AMS, or FDT DTM (PACTware™), EDDL Menu Languages Transmitter LCD: English, French, German, Spanish, Russian HART DD: English, French, German, Spanish, Russian, Chinese, Portuguese FOUNDATION fieldbus and Modbus Host System: English Power (at transmitter terminals) HART: General Purpose (Weatherproof)/Intrinsically Safe/Explosion-proof: 16 to 36 VDC 11 VDC minimum under certain conditions (refer to I&O Manual 57-606) FOUNDATION fieldbus: 9 to 17.5 VDC FISCO ia / FNICO ic, Explosion Proof, General Purpose and Weatherproof Modbus: 8 to 30 VDC Explosion Proof, General Purpose, and Weatherproof Housing Material Net/Gross Weight IP67/die-cast aluminum A413 (<0.4% copper); optional stainless steel Aluminum: Stainless Steel: 4.5 lbs. (2.0 kg) 10.0 lbs. (4.50 kg) Overall Dimensions H 8.34" (212 mm) x W 4.03" (102 mm) x D 7.56" (192 mm) Cable Entry 1 SIL 2 Hardware (Safety Integrity Level) Safe Failure Fraction = 93% (HART only) ⁄2" NPT or M20 Functional Safety to SIL 2 as 1oo1 in accordance with IEC 61508 8 TRANSMITTER SPECIFICATIONS CONTINUED FUNCTIONAL/PHYSICAL Environment Operating Temperature -40 to +175 °F (-40 to +80 °C); LCD viewable -5 to +160 °F (-20 to +70 °C) Storage Temperature -50 to +185 °F (-45 to +85 °C) Humidity 0 to 99%, non-condensing Electromagnetic Compatibility Meets CE requirement (EN 61326) and NAMUR NE 21 NOTE: Single Rod and Twin Cable probes must be used in metallic vessel or stillwell to maintain CE noise immunity Surge Protection Meets CE EN 61326 (1000V) Shock/Vibration ANSI/ISA-S71.03 Class SA1 (Shock); ANSI/ISA-S71.03 Class VC2 (Vibration) Performance Reference Conditions ¿ Reflection from liquid, with dielectric constant in center of selected range, with a 72" (1.8 m) coaxial probe at +70 °F (+20 °C), in Auto Threshold Mode Linearity ¡ Coaxial/Caged Probes: <0.1% of probe length or 0.1 inch (2.5 mm), whichever is greater Single Rod in Tanks/Twin Cable: <0.3% of probe length or 0.3 inch (7.5 mm), whichever is greater Accuracy ¬ Coaxial/Caged Probes: ±0.1% of probe length or ±0.1 inch (2.5 mm), whichever is greater Single Rod in Tanks/Twin Cable: ±0.5% of probe length or ±0.5 inch (13 mm), whichever is greater Interface Operation: Coaxial/Caged probes: ±1 inch (25 mm) for an interface thickness greater than 2 inches (50 mm) Twin Flexible probes: ±2 inch (50 mm) for an interface thickness greater than 8 inches (200 mm) Resolution ±0.1 inch or 1 mm Repeatability <0.1 inch (2.5 mm) Hysteresis <0.1 inch (2.5 mm) Response Time Approximately 1 second Initialization Time Less than 10 seconds Ambient Temperature Effect Approx. ±0.02% of probe length/degree C (for probes greater than 8 feet (2.5 m)) Process Dielectric <0.3 inch (7.5 mm) within selected range ™ FOUNDATION fieldbus ITK Version 6.1.1 H1 Device Class Link Master (LAS) —selectable ON/OFF H1 Profile Class 31PS, 32L Function Blocks (8) Al, (3) Transducer, (1) Resource, (1) Arithmetic, (1) Input Selector, Quiescent Current 15 mA Execution Time 15 ms (40 ms PID Block) Device Revision 01 DD Version 0x01 (1) Signal Characterizer, (2) PID, (1) Integrator Modbus Power Consumption <0.5W Signal Wiring Two-wire half duplex RS-485 Modbus Ground (common mode) Voltage ±7V Bus Termination Per EIA-485 ¿ Specifications will degrade in Fixed Threshold mode. ¡ Linearity in top 18 inches (46 cm) of Twin Cable and Single Rod probes in tanks will be application dependent. ¬ Accuracy may degrade when using manual or automatic compensation. 9 COAXIAL PROBE MATRIX 7yT 7yP Description Standard Temperature High Pressure Application Level/Interface Level/Interface Installation Tank/Chamber Tank/Chamber Overfill Safe Yes Yes 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Monel® (2.4360) 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Monel® (2.4360) Materials — Probe Teflon® TFE with Viton® o-rings ¿ Hermetic Glass Ceramic, Inconel Process Seal Spacers Teflon® TFE Teflon® TFE 316 SS: 1.75" (45 mm) Hastelloy: 1.90" (49 mm) Monel: 1.90" (49 mm) 0.87" (22.5 mm) 316 SS: 1.75" (45 mm) Hastelloy: 1.90" (49 mm) Monel: 1.90" (49 mm) 0.87" (22.5 mm) Enlarged 2" NPT (3⁄4" NPT or 1" BSP) Various ANSI, EN1092, and proprietary flanges Enlarged 2" NPT (3⁄4" NPT or 1" BSP) Various ANSI, EN1092, and proprietary flanges Probe Outside Diameter Enlarged Basic Process Connection Threaded Flanged Available Probe Length Standard 12 to 240 inches (30 to 610 cm) 12 to 240 inches (30 to 610 cm) 30 feet (9 m) max. segmented Enlarged 30 feet (9 m) max. segmented Transition Zones ¡ Top Bottom Process Temperature Max. Process Pressure ¬ Dielectric Range Vacuum Service √ 0 inches (0 mm) 0 inches (0 mm) εr = 1.4: 6 inches (150 mm) ƒ, εr = 1.4: 6 inches (150 mm) ƒ, εr = 80: 2 inches (50 mm) εr = 80: 2 inches (50 mm) -40 to +400 °F (-40 to +200 °C) -320 to +400 °F (-196 to +200 °C) 1000 psi @ +70 °F (70 bar @ +20 °C) 6250 psi @ +70°F (431 bar @ +20°C) 1.4 to 100 ≈ 1.4 to 100 ≈ Negative Pressure, but no hermetic seal Full Vacuum 2000cP (mPa.s) 500cP (mPa.s) 2000cP (mPa.s) 500cP (mPa.s) Filming Filming Viscosity Enlarged Basic Media Coating ¿ Other o-ring materials available upon request. ¡ Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. ¬ Refer to chart on page 16. √ ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to <10-8 cc/sec @ 1 atmosphere helium. ƒ Can be reduced to 3" (75 mm) when lower accuracy is acceptable. ≈ 1.2 minimum dielectric when end of probe analysis is enabled. 10 COAXIAL PROBE MATRIX CONTINUED 7yD 7yS Description High Temp./High Pressure Steam Probe Application Level/Interface Saturated Steam Installation Tank/Chamber Tank/Chamber Overfill Safe Yes No ≈ Materials — Probe Process Seal Spacers 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Monel® (2.4360) 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Hermetic Glass Ceramic, Inconel Hermetic Glass Ceramic, PEEK HT, Inconel PEEK HT/Ceramic PEEK HT/Ceramic 316 SS: 1.75" (45 mm) Hastelloy: 1.92" (49 mm) Monel: 1.92" (49 mm) N/A 0.87" (22.5 mm) 0.87" (22.5 mm) N/A 1.25" (31.8 mm) 2" NPT or 2" BSP Various ANSI, EN1092, and proprietary flanges ⁄4" NPT or 1" BSP ∆ Various ANSI, EN1092, and proprietary flanges Probe Outside Diameter Enlarged Basic HIgh-Temp Model 7YS Process Connection Threaded Flanged 3 Available Probe Length Standard 12 to 240 inches (30 to 610 cm) 24 to 240 inches (60 to 610 cm) N/A Enlarged 30 feet (9 m) max. segmented Transition Zones ¿ Top Bottom 0 inches (0 mm) εr = 1.4: 6 inches (150 mm) √, εr = 80: 2 inches (50 mm) 8 inches (200 mm) εr = 80: 2 inches (50 mm) Process Temperature -320 to +850 °F (-196 to 450 °C) -58 to +750 °F (-50 to +400 °C) « Max. Process Pressure ¡ 6250 psi @ +70 °F (431 bar @ +20 °C) 3000 psi (207 bar) Dielectric Range 1.4 to 100 ƒ 10 to 100 Vacuum Service ¬ Full Vacuum Full Vacuum 2000cP (mPa.s) 500cP (mPa.s) N/A 500cP (mPa.s) Filming Filming Viscosity Enlarged Basic Media Coating ¿ Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. ¡ Refer to chart on page 16. ¬ ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to <10-8 cc/sec @ 1 atmosphere helium. √ Can be reduced to 3" (75 mm) when lower accuracy is acceptable. ƒ 1.2 minimum dielectric when end of probe analysis is enabled. ≈ Consult factory for overfill applications. ∆ Not available with +650 °F (+345 °C) version of the 7yS probe. « When installed in side-mounted chamber. 11 CAGED PROBE MATRIX 7yG 7yL 7yJ Description Standard Temperature High Pressure High Temp./High Pressure Application Level/Interface Level/Interface Level/Interface Installation Chamber Chamber Chamber Yes Yes Yes 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Monel® (2.4360) 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Monel® (2.4360) 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Monel® (2.4360) Overfill Safe ∆ Materials — Probe Teflon® TFE with Viton® o-rings¿ Hermetic Glass Ceramic, Inconel Hermetic Glass Ceramic, Inconel Process Seal Spacers PEEK PEEK PEEK HT/Celazole Probe Outside Diameter .5" (13 mm) to .75" (19 mm) .5" (13 mm) to .75" (19 mm) .5" (13 mm) to .75" (19 mm) 2" Chamber 3" Chamber .75" (19 mm) to 1.13" (29 mm) .75" (19 mm) to 1.13" (29 mm) .75" (19 mm) to 1.13" (29 mm) 4" Chamber 1.05" (27 mm) to 1.50" (38 mm) 1.05" (27 mm) to 1.50" (38 mm) 1.05" (27 mm) to 1.50" (38 mm) Process Connection Flanged Various ANSI, EN1092, and proprietary flanges Various ANSI, EN1092, and proprietary flanges Various ANSI, EN1092, and proprietary flanges Available Probe Length 12 to 240 inches (30 to 610 cm) 12 to 240 inches (30 to 610 cm) 12 to 240 inches (30 to 610 cm) Transition Zones ¡ Top Bottom Process Temperature Max. Process Pressure ¬ Dielectric Range ∆ Vacuum Service √ Viscosity Media Coating 0 inches (0 mm) 0 inches (0 mm) 0 inches (0 mm) -40 to +400 °F (-40 to +200 °C) -320 to +400 °F (-196 to +200 °C) -320 to +850 °F (-196 to +450 °C) εr = 1.4: 6 inches (150 mm) ƒ, εr = 1.4: 6 inches (150 mm) ƒ, εr = 1.4: 6 inches (150 mm) ƒ, εr = 80: 2 inches (50 mm) εr = 80: 2 inches (50 mm) εr = 80: 2 inches (50 mm) 1000 psi @ +70 °F (70 bar @ +20 °C) 6250 psi @ +70 °F (431 bar @ +20 °C) 6250 psi @ +70 °F (431 bar @ +20 °C) 1.4 to 100 ≈ 1.4 to 100 ≈ 1.4 to 100 ≈ Negative Pressure, but no hermetic seal Full Vacuum Full Vacuum 10,000cP (mPa.s) 10,000cP (mPa.s) 10,000cP (mPa.s) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) ¿ Other o-ring materials available upon request. ¡ Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. ¬ Refer to chart on page 16. √ ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to <10-8 cc/sec @ 1 atmosphere helium. ƒ Can be reduced to 3" (75 mm) when lower accuracy is acceptable. ≈ 1.2 minimum dielectric when end of probe analysis is enabled. ∆ When installed in the proper chamber/cage/stilling well. 12 SINGLE ROD RIGID PROBE MATRIX 7yF 7yM 7yN Description Standard Temperature High Pressure High Temp./High Pressure Application Level Level Level Installation Tank Tank Tank No No No 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Monel® (2.4360) PFA Insulated 316/316L rod 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Monel® (2.4360) 316/316L (1.4401/1.4404) Hastelloy® C (2.4819) Monel® (2.4360) Overfill Safe ∆ Materials — Probe Teflon® TFE with Viton® o-rings¿ Hermetic Glass Ceramic, Inconel Hermetic Glass Ceramic, Inconel Process Seal Spacers Probe Outside Diameter None None PEEK HT/Celazole Bare: 0.38" (10 mm) rod Coated: 0.625" (16 mm) rod Bare: 0.38" (10 mm) rod Bare: 0.50" (13 mm) rod 1" or 2” (NPT or BSP) Various ANSI, EN1092, and proprietary flanges 1" or 2” (NPT or BSP) Various ANSI, EN1092, and proprietary flanges 2” (NPT or BSP) Various ANSI, EN1092, and proprietary flanges Process Connection Threaded Flanged Available Probe Length 24 to 288 inches (60 to 732 cm) 24 to 288 inches (60 to 732 cm) 24 to 288 inches (60 to 732 cm) 240 inches (610 cm) maximum for PFA coated probes Transition Zones ¡ Top Bottom Process Temperature Max. Process Pressure ¬ Dielectric Range Vacuum Service √ Viscosity Media Coating Application Dependent Application Dependent Application Dependent -40 to +400 °F (-40 to +200 °C) -320 to +400 °F (-196 to +200 °C) -320 to +850 °F (-196 to +450 °C) εr = 1.4: 6 inches (150 mm) ƒ, εr = 1.4: 6 inches (150 mm) ƒ, εr = 1.4: 6 inches (150 mm) ƒ, εr = 80: 2 inches (50 mm) εr = 80: 2 inches (50 mm) εr = 80: 2 inches (50 mm) 1000 psi @ +70 °F (70 bar @ +20 °C) 6250 psi @ +70 °F (431 bar @ +20 °C) 6250 psi @ +70 °F (431 bar @ +20 °C) 1.7 to 100 ≈ 1.7 to 100 ≈ 1.7 to 100 ≈ Negative Pressure, but no hermetic seal Full Vacuum Full Vacuum 10,000cP (mPa.s) 10,000cP (mPa.s) 10,000cP (mPa.s) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) ¿ Other o-ring materials available upon request. ¡ Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. ¬ Refer to chart on page 16. √ ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to <10-8 cc/sec @ 1 atmosphere helium. ƒ Can be reduced to 3" (75 mm) when lower accuracy is acceptable. ≈ 1.2 minimum dielectric when end of probe analysis is enabled. ∆ Overfill capability can be achieved with software. 13 FLEXIBLE PROBES FOR LIQUIDS MATRIX 7y1 7y3 Description Single Flexible Standard Temperature Single Flexible High Pressure Application Level Level Installation Tank Tank No No 316 (1.4401) (optional PFA coating) 316 (1.4401) Teflon® TFE with Viton® o-rings¿ Hermetic Glass Ceramic 0.19 inches (5 mm) 0.19 inches (5 mm) 2" NPT or 2" BSP Various ANSI, EN1092, and proprietary flanges 2" NPT or 2" BSP Various ANSI, EN1092, and proprietary flanges 3 to 100 feet (1 to 30 meters) 3 to 100 feet (1 to 30 meters) 18 inches (45 cm) 12 inches (30 cm) 18 inches (45 cm) 12 inches (30 cm) -40 to +400 °F (-40 to +200 °C) -320 to +400 °F (-196 to +200 °C) Overfill Safe ≈ Materials — Cable Process Seal Probe Outside Diameter Process Connection Threaded Flanged Available Probe Length Transition Zones ¡ Top Bottom Process Temperature Max. Process Pressure ¬ Dielectric Range ƒ Vacuum Service √ Viscosity Media Coating 1000 psi @ +70 °F (70 bar @ +20 °C) 6250 psi @ +70 °F (431 bar @ +20 °C) 1.7 to 100 1.7 to 100 Negative Pressure, but no hermetic seal Full Vacuum 10,000 (mPa.s) 10,000 (mPa.s) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) ¿ Other o-ring materials available upon request. ¡ Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. ¬ Refer to chart on page 16. √ ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to <10-8 cc/sec @ 1 atmosphere helium. ƒ 1.2 minimum dielectric when end of probe analysis is enabled. ≈ Overfill capability can be achieved with software. 14 FLEXIBLE PROBES FOR LIQUIDS MATRIX CONTINUED 7y4 (Future) 7y6 7y7 Description Single Flexible Standard Temperature Single Flexible HTHP Twin Flexible Standard Temperature Application Level Level Level/Interface Installation Chamber Tank/Chamber Tank/Chamber Overfill Safe No No No 316 (1.4401) 316 (1.4401) 316 SS (1.4401) Cables with FEP Webbing Teflon® TFE with Viton® o-rings Hermetic Glass Ceramic Teflon® TFE with Viton® o-rings 0.19 inches (5 mm) 0.19 inches (5 mm) (2) 0.25 inches (6 mm) 2" NPT or 2" BSP Various ANSI, EN, and proprietary flanges 2" NPT or 2" BSP Various ANSI, EN, and proprietary flanges 2" NPT or 2" BSP Various ANSI, EN, and proprietary flanges 3 to 100 feet (1 to 30 meters) 3 to 100 feet (1 to 30 meters) 3 to 100 feet (1 to 30 meters) 18 inches (45 cm) 12 inches (30 cm) 18 inches (45 cm) 12 inches (30 cm) 18 inches (45 cm) 12 inches (30 cm) -40 to +400 °F (-40 to +200 °C) -320 to +850 °F (-196 to +450 °C) -40 to +400 °F (-40 to +200 °C) Materials — Cable Process Seal ¿ Cable Outside Diameter Process Connection Threaded Flanged Available Probe Length Transition Zones ¡ Top Bottom Process Temperature Max. Process Pressure ¬ Dielectric Range ƒ Vacuum Service √ Viscosity Media Coating 1000 psi @ +70 °F (70 bar @ +20 °C) 6250 psi @ +70 °F (431 bar @ +20 °C) 1000 psi @ +70 °F (70 bar @ +20 °C) 1.7 to 100 1.7 to 100 1.7 to 100 Negative Pressure, but no hermetic seal Full Vacuum Negative Pressure, but no hermetic seal 10,000 (mPa.s) 10,000 (mPa.s) 1500 (mPa.s) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) Maximum Error 10% of coated length (% Error is dependent on dielectric and thickness) ¿ Other o-ring materials available upon request. ¡ Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. ¬ Refer to chart on page 16. √ ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed to <10-8 cc/sec @ 1 atmosphere helium. ƒ 1.2 minimum dielectric when end of probe analysis is enabled. 15 FLEXIBLE PROBES FOR SOLIDS MATRIX 7y2 7y5 Description Single Flexible Standard Temp. Twin Flexible Standard Temp. Application Level Level Installation Tank Tank Overfill Safe No No Pull Down Force 3000 lbs. (1360 Kg) 3000 lbs (1360 Kg) Materials — Cable 316 (1.4401) 316 (1.4401) 0.19 inches (5 mm) (2) 0.25 inches (6 mm) Probe Outside Diameter Process Connection 2" NPT or 2" BSP 2" NPT or 2" BSP Threaded Flanged Various ANSI, EN1092, and proprietary flanges Various ANSI, EN1092, and proprietary flanges Available Probe Length 3 to 100 feet (1 to 30 meters) 3 to 100 feet (1 to 30 meters) 18 inches (45 cm) 12 inches (30 cm) 18 inches (45 cm) 12 inches (30 cm) 4 to 100 1.7 to 100 Negative Pressure, but no hermetic seal Negative Pressure, but no hermetic seal 10,000 (mPa.s) 10,000 (mPa.s) Transition Zones ¿ Dielectric Range ¡ Top Bottom Vacuum Service ¬ Viscosity Media Coating Max. Error 10% of coated length Max. Error 10% of coated length (% Error is dependent on dielectric & thickness) (% Error is dependent on dielectric & thickness) ¿ Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones. ¡ 1.2 minimum dielectric when end of probe analysis is enabled. ¬ ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed (helium leak <10-8cc/sec @ 1 atmos.). 7yD, 7yJ, 7yN, 7y3 and 7y6 Temperature/Pressure Ratings 6500 6500 6000 6000 Maximum Pressure (PSI) Maximum Pressure (PSI) 7yL, 7yM and 7yP Temperature/Pressure Ratings 5500 5000 4500 4000 316/316L SST Hastelloy C276 Monel 400 3500 316/316L SST Hastelloy C276 Monel 400 5500 5000 4500 4000 3500 3000 3000 0 100 200 300 400 500 0 200 400 Temperature (°F) Low Pressure SST Hastelloy Monel High Pressure Probes Low Pressure All Materials Temp. SST Hastelloy Monel All Materials -40 6000 6250 5000 750 +600 3760 5040 3940 — +70 6000 6250 5000 1000 +650 3680 4905 3940 — +100 6000 6250 5000 1000 +700 3620 4730 3920 — +200 5160 6250 4380 650 +750 3560 4430 3880 — +300 4660 6070 4080 400 +800 3520 4230 3820 — +400 4280 5820 3940 270 +850 3480 4060 3145 — +500 3980 5540 3940 — NOTES: • 7yS steam probes are rated to 2200 psi (155 bar) up to +650 °F (+345 °C) • 7y3, 7y6 flexible probes: Pressure is limited by the chamber 1000 1200 • 7y2, 7y5 bulk solids probes: 50 psi (3.45 bar) to +150 °F (+65 °C) 16 800 7yF, 7yG, 7yT, 7y1, 7y4, 7y7 Maximum Pressure (PSI) High Pressure Probes Temp. 600 Temperature (°F) • High pressure probes with threaded fittings are rated as follows: 7yD, 7yN, 7yP and 7y3 probes with threaded fittings have 3600 psi (248 bar) rating. 7yM probes with threaded fittings have 2016 psi (139 bar) rating. 1000 800 600 400 200 0 0 100 200 300 Temperature (°F) 400 500 O-RING (SEAL) “O”-Ring Material Max. Process Temperature SELECTION O-RING/SEAL SPECIFICATIONS Code Min. Process Max. Process Temperature Pressure CHART Not Recommended For Applications Recommended for Applications 0 Viton® GFLT 400 °F @ 230 psi (200 °C @ 16 bar) -40 °F (-40 °C) Ketones (MEK, acetone), skydrol fluids, amines, anhydrous ammonia, low 1000 psi 70 °F (70 bar @ molecular weight esters and 20 °C) ethers, hot hydrofluoric or chlorosulfuric acids, sour HCs 1 EPDM 250 °F @ 200 psi (125 °C @14 bar) -60 °F (-50 °C) 1000 psi 70 °F Petroleum oils, di-ester base (70 bar @ lubricant, steam 20 °C) 2 Kalrez® 4079 400 °F @ 232 psi (200 °C @ 16 bar) -40 °F (-40 °C) 1000 psi 70 °F (70 bar @ 20 °C) -4 °F (-20 °C) Halogenated HCs, nitro HCs, phosphate ester hydraulic 1000 psi 70 °F fluids, ketones (MEK, (70 bar @ acetone), strong acids, 20 °C) ozone, automotive brake fluid, steam NACE applications General purpose sealing, petroleum oils and fluids, cold water, silicone greases and oils, di-ester base lubricants, ethylene glycol base fluids 3 HSN 275 °F @ 320 psi (Highly Saturated (135 °C @ 22 bar) Nitrile) Hot water/steam, hot aliphatic amines, ethylene oxide, propylene oxide General purpose, ethylene Acetone, MEK, skydrol fluids Inorganic and organic acids (including hydro fluids and nitric), aldehydes, ethylene, organic oils, glycols, silicone oils, vinegar, sour HCs 4 Buna-N 275 °F @ 320 psi (135 °C @ 22 bar) -4 °F (-20 °C) Halogenated HCs, nitro HCs, phosphate ester hydraulic 1000 psi 70 °F fluids, ketones (MEK, (70 bar @ acetone), strong acids, 20 °C) ozone, automotive brake fluid 5 Neoprene® 300 °F @ 290 psi (150 °C @ 20 bar) -65 °F (-55 °C) 1000 psi 70 °F (70 bar @ 20 °C) Phosphate ester fluids, ketones (MEK, acetone) Refrigerants, high anline point petroleum oils, silicate ester lubricants Acetaldehyde, ammonia + lithium metal solution, butyraldehyde, di-water, freon, ethylene oxide, liquors, isobutyraldehyde Inorganic and organic acids, alkalines, ketones, esters, aldehydes, fuels 6 Chemraz® 505 400 °F @ 200 psi (200 °C @ 14 bar) -20 °F (-30 °C) 1000 psi 70 °F (70 bar @ 20 °C) 7 Polyurethane 200 °F @ 420 psi (95 °C @29 bar) -65 °F (-55 °C) 1000 psi 70 °F (70 bar @ 20 °C) Acids, Ketones, chlorinated HCs, Hydraulic systems, petroleum oils, HC fuel, oxygen, ozone Inorganic and organic acids (including hydro fluids and nitric), aldehydes, ethylene, organic oils, glycols, silicone oils, vinegar, sour HCs, steam, amines, ethylene oxide, propylene oxide, NACE applications 8 Aegis PF128 ¿ 400 °F @ 232 psi (200 °C @ 16 bar) -4 °F (-20 °C) 1000 psi 70 °F (70 bar @ 20 °C) Black liquor, freon 43, freon 75, galden, KEL-F liquid, molten potassium, molten sodium A Kalrez 6375 400 °F @ 232 psi (200 °C @ 16 bar) -40 °F (-40 °C) 1000 psi 70 °F (70 bar @ 20 °C) Hot water/steam, hot aliphatic amines, ethylene oxide, propylene oxide Inorganic and organic acids (including hydro fluids and nitric), aldehydes, ethylene, organic oils, glycols, silicone oils, vinegar, sour HCs B Kalrez® 6375 400 °F @ 232 psi (200 °C @ 16 bar) -40 °F (-40 °C) 1000 psi 70 °F (70 bar @ 20 °C) Hot water/steam, hot aliphatic amines, ethylene oxide, propylene oxide Hydrofluoric Acid D or N Glass Ceramic Alloy 850 °F @ 3600 psi (450 °C @ 248 bar) -320 °F (-195 °C) 6250 psi 70 °F (431 bar @ 20 °C) Hot alkaline solutions HF acid, media with ph>12, direct exposure to saturated steam General high temperature/high pressure applications, hydrocarbons, full vacuum (hermetic), ammonia, chlorine ® ¿ Maximum +300 °F (+150 °C) for use on steam. 17 REPLACEMENT OF DISPLACER ECLIPSE has proven to be the ideal replacement for existing torque tube transmitters. In numerous applications worldwide, customers have found the performance of ECLIPSE Guided Wave Radar transmitters to be superior to that of antiquated torque tube transmitters. There are several benefits to using the ECLIPSE Model 706 as a replacement for torque tube transmitters: • Cost: The cost of a new Model 706 transmitter cost is comparable to rebuilding an aging torque tube. • Installation: No field calibration is necessary. The Model 706 transmitter can be configured in minutes with no level movement. (Complete factory pre-configuration is available, which can further decrease the installation effort). • Performance: The ECLIPSE Model 706 is unaffected by changes in specific gravity and has no moving parts that can wear and lose tolerance. TRANSMITTERS • Ease of replacement: Proprietary and standard ANSI flanges are offered on all ECLIPSE Model 706 probes so existing chamber/cages can be used. In order to match the proper ECLIPSE transmitter with the proper external cage, consider the following: • Type of application: Use the proper GWR probe for the application, see pages 7 and 10 through 16. • Overfill proof: For optimum performance, use an Overfill-safe probe in all chamber applications. Note: “Overfill” occurs when the level rises above the maximum range of operation. Some GWR probes may provide erroneous output in this zone unless an optimal, impedancematched design is used. • Minimum Cage Size: • Coaxial or Caged Coaxial probes: 2" minimum • Enlarged Coaxial probes: 3" minimum • Twin Cable probes: 4" minimum Before Body connection E 20 mA / 100 % P Measuring range: min 12” (30 cm) max 224" (570) H Displacer Length Probe Insertion Length = E + measuring range + F After 4 mA / 0 % F min 1" (2.5cm) Recommended probe length for replacing displacer transmitters The table below helps to define the GWR probe length for the most common displacer transmitters. Refer to the proprietary flange selection guide. Manufacturer Type Process Connection MAGNETROL EZ & PN Modulevel® Masoneilan® Series 1200 Fisher® series 2300 & 2500 Eckardt® 249B, 259B, 249C cages other cages Series 134, 144 Tokyo Keiso® FST-3000 ANSI/EN flange Proprietary flange ANSI/EN flange Proprietary flange ANSI flange ANSI/EN flange ANSI/EN flange ANSI/EN flange ¿ Round down resulting calculation to the nearest inch. 18 Displacer Length inches (mm) ≥ 14" (356) ≥ 14" (356) ≥ 16" (406) ≥ 14" (356) ≥ 14" (356) ≥ 14" (356) H = 11.8" (300) ≥ H = 19.7" (500) Probe Length ¿ inches (mm) Displacer + 7 (178) Displacer + 8 (203) Displacer + 8 (203) Displacer + 10 (254) consult factory consult factory Displacer + 9 (229) Displacer + 9 (229) PROPRIETARY INCHES FLANGES (mm) ∅ 9.00 (229) ∅ 5.62 (143) ∅ 7.25 (184) ∅ 7.50 (191) ∅ 4.75 (121) 45° 45° 45° ∅ 0.43 (11) ∅ 0.87 (22) ∅ 0.87 (22) 1.25 (32) 5.23 (133) 1.12 (29) 3.37 (86) 0.22 (6) Fisher 249B/259B (600 lb.), carbon steel MAGNETROL ∅ 5.875 (149) 1.25 (32) 4.00 (102) .188 (5) Fisher 249C (600 lb.), 316 stainless steel 0.25 (6) Masoneilan (600 lb.), carbon steel CHAMBERS A brief description of the MAGNETROL chamber offering follows. For more details, refer to MAGNETROL Sales Bulletin 41-140. MAGNETROL has a long tradition in offering cost-effective chambers. The MAGNETROL external chamber is a self-contained cage designed for use with our top mounting level transmitters or switches. Quality construction and a wide selection of configurations make this cage an ideal means of utilizing the power of Guided Wave Radar without mounting directly into the process vessel. MAGNETROL chambers are available with a wide variety of options, and can be manufactured to comply with various regulations such as: • Commercial Design ordered together with a factory pre-configured Model 706 for a true “plug and play” installation. For example: A standard Model 706-511A-310 explosion-proof transmitter with a Model 7AG-4300-A10-00-021 Caged probe can be used in a 2" chamber. A typical chamber Model Number would be: • ASME B31.1 Design Code • ASME B31.3 Design Code • NACE Design Code F21-4A2D-014 • PED Some Model 706 probes can be installed into chambers as small as 2". When a new chamber is required, it can be Measuring Range Refer to MAGNETROL Sales Bulletin 41-140 for details on chamber Model Numbers and additional options. Measuring Range 1" NPT drain Sealed Chamber Slip-on head flange Measuring Range 1" NPT drain Weld neck head flange 19 AGENCY APPROVALS These units are in compliance with the EMC-directive 2004/108/EC, the PED-directive 97/23/EC and the ATEX directive 94/9/EC. IEC 60079-0: 2001 IEC 60079-15: 2010 IEC 60079-26: 2006 Explosion Proof (with intrinsically Safe Probe) Non- Incendive US/Canada: Class I, Div 1, Group B, C and D, T4 Class I, Zone 1 AEx d/ia [ia IIC Ga] IIB + H2 T4 Gb/Ga Class I, Zone 1 Ex d/ia [ia IIC Ga] IIB + H2 T4 Gb/Ga Ta = -40ºC to +70ºC Type 4X, IP67 US/Canada: Class I, II, III, Division 2, Group A, B, C, D, E, F, G, T4 Class I, Zone 2 AEx ia/nA [ia Ga] IIC T4 Ga/Gc Class I, Zone 2 Ex ia/nA [ia Ga] IIC T4 Ga/Gc Ta = -40ºC to +70ºC Type 4X, IP67 Flame Proof ATEX – FM14ATEX0041X: II 2/1 G Ex d/ia [ia IIC Ga] IIB + H2 T6 to T1 Gb/Ga Ta = -40ºC to +70ºC IP67 ATEX II 1/3 G Ex ia/nA [ia Ga] IIC T4 Ga/Gc Ta = -15ºC to +70ºC IP67 IEC- IECEx FMG 14.0018X: Ex d/ia [ia IIC Ga] IIB + H2 T6 to T1 Gb/Ga Ta = -40ºC to +70ºC IP67 IEC – IECEx FMG 14.00018X: Ex ia/nA [ia Ga] IIC T4 Ga/Gc Ta = -15ºC to + 70ºC IP67 Intrinsically Safe Dust Ignition Proof US/Canada: Class I, II, III, Div 1, Group A, B, C, D, E, F, G, T4, Class I, Zone 0 AEx ia IIC T4 Ga Class I, Zone 0 Ex ia IIC T4 Ga Ta =-40ºC to + 70ºC Type 4X, IP67 US/Canada: Class II, III, Division 1, Group E, F and G, T4 Ta = -40ºC to +70ºC Type 4X, IP67 ATEX – FM14ATEX0041X: II 1 G Ex ia IIC T4 Ga Ta = -40ºC to +70ºC IP67 IEC – IECEx FMG 14.0018X: Ex ia IIC T4 Ga Ta = -40ºC to +70ºC IP67 ATEX – FM14ATEX0041X: II 1/2 D Ex ia/tb [ia Da] IIIC T85ºC to T450ºC Da/Db Ta = -15ºC to +70ºC IP67 IEC – IECEx FMG 14.0018X: Ex ia tb [ia Da] IIIC T85ºC to T450ºC Db Ex ia IIIC T85ºC to T450ºC Da Ta = -15ºC to +70ºC IP67 The following approval standards are applicable: FM3600:2011, FM3610:2010, FM3611:2004, FM3615:2006, FM3616:2011, FM3810:2005, ANSI/ISA60079-0:2013, ANSI/ISA 60079-1:2009, ANSI/ISA 60079-11:2013, ANSI/ISA 60079-15:2012, ANSI/ISA 60079-26:2011, NEMA 250:2003, ANSI/IEC 60529:2004, C22.2 No. 0.4:2009, C22.2 No. 0.5:2008, C22.2 No. 30:2007, C22.2 No. 94:2001, C22.2 No. 157:2012, C22.2 No. 213:2012, C22.2 No. 1010.1:2009, CAN/CSA 60079-0:2011, CAN/CSA 60079-1:2011, CAN/CSA 60079-11:2011, CAN/CSA 60079-15:2012, C22.2 No. 60529:2005, EN60079-0:2012, EN60079-1:2007, EN60079-11:2012, EN60079-15:2010, EN60079-26:2007, EN60079-31:2009, EN60529+A1:1991-2000, IEC60079-0:2011, IEC60079-1:2007, IEC60079-11:2011, IEC60079-15:2010, IEC60079-26:2006, IEC60079-31:2008 20 AGENCY APPROVALS Special Conditions of Use 1. The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or friction. Care must be taken during installation and use to prevent impact or friction. 2. The risk of electrostatic discharge shall be minimized at installation, following the directions given in the instructions. 3. Contact the original manufacturer for information on the dimensions of the flameproof joints. 4. For installation with ambient temperature of +70 °C, refer to the manufacturer’s instructions for guidance on proper selection of conductors. 5. WARNING—Explosion Hazard: Do not disconnect equipment when flammable or combustible atmoshpere is present. 6. For IEC and ATEX: To maintain the T1 to T6 temperature codes, care shall be taken to ensure the enclosure temperature does not exceed +70 °C. 7. For U.S. and Canada: To maintain the T4 temperature code, care shall be taken to ensure the enclosure temperature does not exceed +70 °C. 8. Temperature codes for the ratings Ex d/ia [ia IIC] IIB+H2 and Ex ia/tb [ia] IIIC are defined by the following table: Process Temperature (PT) Temperature Code-TCG (GAS) Temperature Code-TCD (Dust) Up to 75 °C T6 TCD= PT+10K=85 °C From 75 to 90 °C T5 TCD= PT+10K=100 °C From 90 to 120 °C T4 TCD= PT+15K=135 °C From 125 to 185 °C T3 TCD= PT+15K=200 °C From 185 to 285 °C T2 TCD= PT+15K=300 °C From 285 to 435 °C T1 TCD= PT+15K=450 °C Agency Specifications – Explosion Proof Installation Factory Sealed: This product has been approved by Factory Mutual Research (FM) and Canadian Standards Association (CSA) as a Factory Sealed device. NOTE: Factory Sealed: No Explosion Proof conduit fitting (EY seal) is required within 18" of the transmitter. However, an Explosion Proof conduit fitting (EY seal) is required between the hazardous and safe areas. 21 MODEL NUMBER TRANSMITTER Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). 1 2 3 | BASIC MODEL NUMBER 706 ECLIPSE 4th Generation Guided Wave Radar (GWR) Level Transmitter 4 | POWER 5 24 VDC, Two-Wire 5 | SIGNAL OUTPUT 1 4 –20 mA with HART 2 FOUNDATION fieldbus™ Communication 4 Modbus Communication (8th Digit = 0 or 3 only) 6 | SAFETY OPTIONS 0 None – FOUNDATION fieldbus and Modbus only (5th digit = 2 or 4) 1 SIL 2 Hardware - HART only (5th digit = 1) 2 SIL 2/3 Certified - HART only (5th digit = 1) 7 | ACCESSORIES/MOUNTING 0 No Digital Display or Keypad - Integral 1 No Digital Display or Keypad - 3-foot (1 meter) remote 2 No Digital Display or Keypad - 12-foot (3.6 meter) remote A Digital Display and Keypad - Integral B Digital Display and Keypad - 3-foot (1 meter) remote C Digital Display and Keypad - 12-foot (3.6 meter) remote 8 | CLASSIFICATION 0 General Purpose, Weatherproof (IP 67) 1 Intrinsically Safe (FM & CSA CL 1 Div 1, Grps A, B, C, D) (5th digit = 1 or 2) 3 Explosion-proof (FM & CSA CL 1 Div 1, Grps B, C, D) A Intrinsically Safe (ATEX/IEC Ex ia IIC T4) (5th digit = 1 or 2) B Flame-proof (ATEX/IEC Ex d ia IIC T6) (5th digit = 1 or 2) C Non-sparking (ATEX Ex n IIC T6) (5th digit = 1 or 2) D Dust Ex (ATEX II) (5th digit = 1 or 2) 9 | HOUSING 1 Die-cast Aluminum, Dual-compartment, 45-degree 2 Investment Cast, Stainless Steel, Dual-compartment, 45-degree 10 | CONDUIT CONNECTION 22 7 0 6 5 1 2 3 4 5 6 7 8 9 0 1 1 M20 2 1 3 M20 with sunshade 10 ⁄2" NPT ⁄2" NPT with sunshade DIMENSIONS inches 3.38 (86) (mm) 4.18 (106) 3.77 (96) 8.34 (212) 4.18 (106) 3.38 (86) 9.30 (236) 5.09 (129) 3.77 (96) 2 cable entries 4.03 (102) 45° Integral Electronics Eclipse® Housing (45° View) 2 cable entries 2.37 (60) 45° 3.00 (76) 2.00 (51) 3.50 (89) 33 or 144 (838 or 3650) 3.75 (95) 2 Holes .38 (10) Dia. 4.15 (105) Eclipse® Remote Configurations ELECTRICAL WIRING HART ® modem 0% 100% Standard shielded twisted pair cable recommended but not needed when wired as per NAMUR NE 21 (for field strengths up to 10 V/m) Galvanic Barrier: Entity parameters per Agency Certificate (not needed for GP, Dust Ex, and explosion-proof models). 250Ω minimum required for HART Communications Ex Non Ex 23 MODEL NUMBER ENLARGED COAXIAL PROBE Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). 1 | TECHNOLOGY 7 ECLIPSE GWR Probes - Model 706 2 | MEASUREMENT SYSTEM A English C Metric 3 | CONFIGURATION/STYLE (RIGID) D Enlarged Coaxial, High Temp/High Pressure: Overfill w/Glass Seal (+850 °F/+450 °C) — Only available with 10th digit N or D P Enlarged Coaxial, High Pressure: Overfill w/Glass Seal (+400 °F/+200 °C) — Only available with 10th digit N or D T Enlarged Coaxial, Overfill Standard O-Ring Seal (+400 °F/+200 °C) — NOT available with 10th digit N or D 4 5 | PROCESS CONNECTION – SIZE/TYPE (consult factory for other process connections) Threaded 2" NPT Thread ¿ 41 42 2" BSP (G1) Thread ¿ ANSI Flanges 43 2" 44 2" 45 2" 150# ANSI RF ¿ 300# ANSI RF ¿ 5M 3" 1500# ANSI RTJ 5N 3" 2500# ANSI RTJ 4" 150# ANSI RF 4K 600# ANSI RTJ ¿ 63 2" 64 4" 300# ANSI RF 53 3" 150# ANSI RF 65 4" 600# ANSI RF 54 3" 300# ANSI RF 66 4" 900# ANSI RF 55 3" 600# ANSI RF 67 4" 1500# ANSI RF 56 3" 900# ANSI RF 68 4" 2500# ANSI RF 57 3" 1500# ANSI RF 6K 4" 600# ANSI RTJ 58 3" 2500# ANSI RF 6L 4" 900# ANSI RTJ 5K 3" 600# ANSI RTJ 6M 4" 1500# ANSI RTJ 5L 3" 900# ANSI RTJ 6N 4" 2500# ANSI RTJ 600# ANSI RF ¿ EN Flanges DN 50, PN 16 EN 1092-1 TYPE A ¿ DN 80, PN 320 EN 1092-1 TYPE B2 DB DN 50, PN 25/40 EN 1092-1 TYPE A ¿ EH DN 80, PN 400 EN 1092-1 TYPE B2 DN 50, PN 63 EN 1092-1 TYPE B2 ¿ EJ DD DN 100, PN 16 EN 1092-1 TYPE A DE DN 50, PN 100 EN 1092-1 TYPE B2 ¿ FA FB DN 100, PN 25/40 EN 1092-1 TYPE A EA DN 80, PN 16 EN 1092-1 TYPE A FD DN 100, PN 63 EN 1092-1 TYPE B2 EB DN 80, PN 25/40 EN 1092-1 TYPE A FE DN 100, PN 100 EN 1092-1 TYPE B2 ED DN 80, PN 63 EN 1092-1 TYPE B2 FF DN 100, PN 160 EN 1092-1 TYPE B2 EE DN 80, PN 100 EN 1092-1 TYPE B2 FG DN 100, PN 250 EN 1092-1 TYPE B2 EF DN 80, PN 160 EN 1092-1 TYPE B2 FH DN 100, PN 320 EN 1092-1 TYPE B2 EG DN 80, PN 250 EN 1092-1 TYPE B2 FJ DN 100, PN 400 EN 1092-1 TYPE B2 TT 600# Fisher (249B/259B) in carbon steel – as per dimensions on page 18 TU 600# Fisher (249C) in stainless steel – as per dimensions on page 18 UT 600# Masoneilan flange in carbon steel – as per dimensions on page 18 UU 600# Masoneilan flange in stainless steel – as per dimensions on page 18 DA Torque Tube Mating Flanges ¡ ¿ Confirm mounting conditions/nozzle diameter to ensure sufficient clearance. ¡ Always check dimensions if ANSI/EN flanges are not used. 7 1 24 2 3 4 5 6 7 8 9 10 11 12 13 14 15 MODEL NUMBER ENLARGED COAXIAL CONTINUED PROBE 6 | CONSTRUCTION CODES 0 K L M N Industrial ASME B31.1 ASME B31.3 ASME B31.3 & NACE MR0175/MR0103 — NOT available with carbon steel flange NACE MR0175/MR0103 — NOT available with carbon steel flange 7 | FLANGE OPTIONS — Offset flanges are only available with small coaxial probes 0 None 8 | MATERIAL OF CONSTRUCTION - FLANGE/NUT/ROD/INSULATION A B C R S T 316 SS/316L SS (Probe O.D. 1.75” (45mm)) Hastelloy C (Probe O.D. 1.93” (49mm)) Monel (Probe O.D. 1.93” (49mm)) 316 SS/316L SS with Carbon Steel Flange (Probe O.D. 1.75” (45 mm)) Hastelloy C with Carbon Steel Flange (Probe O.D. 1.93” (49mm)) Monel with Carbon Steel Flange (Probe O.D. 1.93” (49mm)) 9 | SPACER MATERIAL 1 2 3 4 5 TFE (+400 °F/+200 °C) — Only available with 3rd digit P or T — εr ≥ 1.4 PEEK HT — Only available with 3rd digit D (+650 °F/+345 °C) — εr ≥ 1.4 Ceramic (High Temp. >+800 °F/+425 °C) — Only available with 3rd digit D — εr ≥ 2.0 Celazole (+800 °F/+425 °C) — Only available with 3rd digit D — εr ≥ 1.4 None - with metal shorting rod — εr ≥ 1.4 — Future 10 | O-RING MATERIALS/SEAL OPTIONS 0 2 8 A B D N Viton® GFLT — Only available with 3rd digit T Kalrez® 4079 — Only available with 3rd digit T Aegis PF 128 (NACE) — Only available with 3rd digit T Kalrez 6375 — Only available with 3rd digit T HF Acid Probe — Only available with 3rd digit T and 8th digit C None/Glass Ceramic Alloy (dual-seal design with annunciator fitting)—Only available with 3rd digit D or P None/Glass Ceramic Alloy — Only available with 3rd digit D, P or S 11 | PROBE SIZE/ELEMENT TYPE/FLUSHING CONNECTION 0 1 Standard Enlarged Coaxial Probe Standard Enlarged Coaxial Probe with Flushing Port 12 | SPECIAL OPTIONS — See page 36 0 1 2 3 4 5 6 Single Length Probe (Non-Segmented) 1-piece Enlarged Segmented Probe OD=2.5”(64mm) 2-piece Enlarged Segmented Probe OD=2.5”(64mm) 3-piece Enlarged Segmented Probe OD=2.5”(64mm) 4-piece Enlarged Segmented Probe OD=2.5”(64mm) 5-piece Enlarged Segmented Probe OD=2.5”(64mm) 6-piece Enlarged Segmented Probe OD=2.5”(64mm) 13 14 15 | INSERTION LENGTH inches (012 – 396) cm (030 – 999) XXX unit of measure determined by 2nd digit of model number 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 25 MODEL SMALL NUMBER COAXIAL PROBE Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). 1 | TECHNOLOGY 7 ECLIPSE GWR Probes - Model 706 2 | MEASUREMENT SYSTEM A C English Metric 3 | CONFIGURATION/STYLE (RIGID) D P S T Small Coaxial, High Temp/High Pressure: Overfill w/Glass Seal (+850 °F/+450 °C) — Only available with 10th digit N or D Small Coaxial, High Pressure: Overfill w/Glass Seal (+400 °F/+200 °C) — Only available with 10th digit N or D Small Coaxial, Saturated Steam (+575/+650 °F [+300/+345 °C]), Max. Length=240” (610 cm) — Only available with 10th digit N, 9th digit 2 or 3 Small Coaxial, Overfill Standard O-Ring Seal (+400 °F/+200 °C) — NOT available with 10th digit N or D 4 5 | PROCESS CONNECTION – SIZE/TYPE (consult factory for other process connections) Threaded 3 ⁄4" NPT Thread ¬ 11 22 1" BSP (G1) Thread ¬ 2" NPT Thread — Only available with 3rd Digit D 41 ANSI Flanges 23 24 25 2K 33 34 35 3K 37 3M 1" 1" 1" 1" 1 1⁄2" 1 1⁄2" 1 1⁄2" 1 1⁄2" 1 1⁄2" 1 1⁄2" 150# ANSI RF ¿ √ 3 8 1 1⁄2" 300# ANSI RF ¿ √ 3 N 1 1⁄2" 600# ANSI RF ¿ √ 4 3 2" 600# ANSI RTJ ¿ √ 4 4 2" 150# ANSI RF √ 4 5 2" 300# ANSI RF √ 4 7 2" 600# ANSI RF √ 4 8 2" 600# ANSI RTJ √ 4 K 2" 900/1500# ANSI RF√ 4 M 2" 900/1500# ANSI RTJ√ 4 N 2" 2500# ANSI RF √ 2500# ANSI RTJ √ 150# ANSI RF 300# ANSI RF 600# ANSI RF 900/1500# ANSI RF 2500# ANSI RF 600# ANSI RTJ 900/1500# ANSI RTJ 2500# ANSI RTJ EN Flanges 53 54 55 56 57 58 5K 5L 5M 5N A¿√ B2 ¿ √ A√ B2 √ B2 √ B2 √ B2 √ B2 √ BB BC CB CC CF CG CH CJ DA DB DD DE DF DG DH DJ DN DN DN DN DN DN DN DN 25, 25, 40, 40, 40, 40, 40, 40, PN PN PN PN PN PN PN PN 16/25/40 EN 63/100 EN 16/25/40 EN 63/100 EN 160 EN 250 EN 320 EN 400 EN 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE DN DN DN DN 50, 50, 50, 50, PN PN PN PN 16 25/40 63 100 EN EN EN EN 1092-1 1092-1 1092-1 1092-1 TYPE TYPE TYPE TYPE DN DN DN DN 50, 50, 50, 50, PN PN PN PN 160 250 320 400 EN EN EN EN 1092-1 1092-1 1092-1 1092-1 TYPE TYPE TYPE TYPE TT TU UT UU 600# 600# 600# 600# Torque Tube Mating Flanges ¡ 42 EA EB ED EE EF EG EH E J FA FB FD FE FF FG FH FJ A A B2 B2 B2 B2 B2 B2 2" BSP (G1) Thread — Only available with 3rd Digit D 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 150# ANSI RF 300# ANSI RF 600# ANSI RF 900# ANSI RF 1500# ANSI RF 2500# ANSI RF 600# ANSI RTJ 900# ANSI RTJ 1500# ANSI RTJ 2500# ANSI RTJ DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN DN 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 63 64 65 66 67 68 6K 6L 6M 6N 80, PN 16 80, PN 25/40 80, PN 63 80, PN 100 80, PN 160 80, PN 250 80, PN 320 80, PN 400 100, PN 16 100, PN 25/40 100, PN 63 100, PN 100 100, PN 160 100, PN 250 100, PN 320 100, PN 400 EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN 150# ANSI RF 300# ANSI RF 600# ANSI RF 900# ANSI RF 1500# ANSI RF 2500# ANSI RF 600# ANSI RTJ 900# ANSI RTJ 1500# ANSI RTJ 2500# ANSI RTJ 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE Fisher (249B/259B) in carbon steel – as per dimensions on page 18 Fisher (249C) in stainless steel – as per dimensions on page 18 Masoneilan flange in carbon steel – as per dimensions on page 18 Masoneilan flange in stainless steel – as per dimensions on page 18 ¿ ¡ ¬ √ Confirm mounting conditions/nozzle diameter to ensure sufficient clearance. Always check dimensions if ANSI/EN flanges are not used. Not available with 3rd digit ‘D’ Not available with 3rd Digit D or P 7 1 26 2 3 4 A A B2 B2 B2 B2 B2 B2 A A B2 B2 B2 B2 B2 B2 5 6 7 8 9 10 11 12 13 14 15 MODEL SMALL NUMBER COAXIAL CONTINUED PROBE 6 | CONSTRUCTION CODES 0 K L M N Industrial ASME B31.1 — NOT available with 4th digits T or U ASME B31.3 ASME B31.3 & NACE MR0175/MR0103 — NOT available with carbon steel flange NACE MR0175/MR0103 — NOT available with carbon steel flange 7 | FLANGE OPTIONS — Offset flanges are only available with small coaxial probes 0 1 2 3 None Offset (For use with AURORA) — 4” Only available with 3rd digit P, S or T Offset with 1⁄2" NPT Vent (For use with AURORA) — 4” Only available with 3rd digit P, S or T Offset with 3⁄4" NPT Vent (For use with AURORA) — 4” Only available with 3rd digit P, S or T 8 | MATERIAL OF CONSTRUCTION - FLANGE/NUT/ROD/INSULATION A B C R S T 316 SS/316L SS Hastelloy C Monel — NOT available with 3rd digit S 316 SS/316L SS with Carbon Steel Flange Hastelloy C with Carbon Steel Flange Monel with Carbon Steel Flange — NOT available with 3rd digit S 9 | SPACER MATERIAL 1 2 3 5 TFE (+400 °F/+200 °C) — Only available with 3rd digit P or T — εr ≥ 1.4 PEEK HT — Only available with 3rd digit D — εr ≥ 1.4 (+650 °F/+345 °C) or S (+575 °F/+300 °C) Ceramic (Temp. >+650 °F/+345 °C) — Only available with 3rd digit D with εr ≥ 2.0 or with 3rd digit S None - with metal shorting rod — εr ≥ 1.4 — Future 10 | O-RING MATERIALS/SEAL OPTIONS 0 2 8 A B D N Viton® GFLT — Only available with 3rd digit T Kalrez® 4079 — Only available with 3rd digit T Aegis PF 128 (NACE) — Only available with 3rd digit T Kalrez 6375 — Only available with 3rd digit T HF Acid Probe — Only available with 3rd digit T and 8th digit C None/Glass Ceramic Alloy (dual-seal design with annunciator fitting)—Only available with 3rd digit D or P None/Glass Ceramic Alloy — Only available with 3rd digit D, P or S 11 | PROBE SIZE/ELEMENT TYPE/FLUSHING CONNECTION 2 Small Coaxial (0.875 inches/22 mm) 12 | SPECIAL OPTIONS 0 Single Length Probe (Non-Segmented) 13 14 15 | INSERTION LENGTH inches (012 – 240) cm (030 – 610) XXX unit of measure determined by 2nd digit of model number 7 1 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 27 MODEL CAGED NUMBER PROBE Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). 1 | TECHNOLOGY 7 ECLIPSE GWR Probes - Model 706 2 | MEASUREMENT SYSTEM A English C Metric 3 | CONFIGURATION/STYLE (RIGID) G Overfill Caged Rigid Probe for use in chambers +400 °F (+200 °C) — Only available with 2", 3" and 4" flanges J Overfill Caged High Temp/High Pressure Probe with Glass Seal for use in chambers +850 °F (+450 °C) Only available with 2", 3" and 4" flanges L Overfill Caged High Pressure Probe with Glass Seal for use in chambers +400 °F (+200 °C) Only available with 2", 3" and 4" flanges 4 5 | PROCESS CONNECTION – SIZE/TYPE (consult factory for other process connections) ¿ ANSI Flanges 43 2" 150# ANSI RF 54 3" 300# ANSI RF 63 4" 150# ANSI RF 44 2" 300# ANSI RF 55 3" 600# ANSI RF 64 4" 300# ANSI RF 45 2" 600# ANSI RF 56 3" 900# ANSI RF 65 4" 600# ANSI RF 47 2" 900/1500# ANSI RF 57 3" 1500# ANSI RF 66 4" 900# ANSI RF 48 2" 2500# ANSI RF 58 3" 2500# ANSI RF 67 4" 1500# ANSI RF 4K 2" 600# ANSI RTJ 5K 3" 600# ANSI RTJ 68 4" 2500# ANSI RF 4M 2" 900/1500# ANSI RTJ 5L 3" 900# ANSI RTJ 6K 4" 600# ANSI RTJ 4N 2" 2500# ANSI RTJ 5M 3" 1500# ANSI RTJ 6L 4" 900# ANSI RTJ 53 3" 150# ANSI RF 5N 3" 2500# ANSI RTJ 6M 4" 1500# ANSI RTJ 6N 4" 2500# ANSI RTJ EN Flanges DA DN 50, PN 16 EN 1092-1 TYPE A EF DN 80, PN 160 EN 1092-1 TYPE B2 DB DN 50, PN 25/40 EN 1092-1 TYPE A EG DN 80, PN 250 EN 1092-1 TYPE B2 DD DN 50, PN 63 EN 1092-1 TYPE B2 EH DN 80, PN 320 EN 1092-1 TYPE B2 DE DN 50, PN 100 EN 1092-1 TYPE B2 E J DN 80, PN 400 EN 1092-1 TYPE B2 DF DN 50, PN 160 EN 1092-1 TYPE B2 FA DN 100, PN 16 EN 1092-1 TYPE A DG DN 50, PN 250 EN 1092-1 TYPE B2 FB DN 100, PN 25/40 EN 1092-1 TYPE A DH DN 50, PN 320 EN 1092-1 TYPE B2 FD DN 100, PN 63 EN 1092-1 TYPE B2 DJ DN 50, PN 400 EN 1092-1 TYPE B2 FE DN 100, PN 100 EN 1092-1 TYPE B2 EA DN 80, PN 16 EN 1092-1 TYPE A FF DN 100, PN 160 EN 1092-1 TYPE B2 EB DN 80, PN 25/40 EN 1092-1 TYPE A FG DN 100, PN 250 EN 1092-1 TYPE B2 ED DN 80, PN 63 EN 1092-1 TYPE B2 FH DN 100, PN 320 EN 1092-1 TYPE B2 EE DN 80, PN 100 EN 1092-1 TYPE B2 FJ DN 100, PN 400 EN 1092-1 TYPE B2 Torque Tube Mating Flanges ¡ TT 600# Fisher (249B/259B) in carbon steel – as per dimensions on page 18 TU 600# Fisher (249C) in stainless steel – as per dimensions on page 18 UT 600# Masoneilan flange in carbon steel – as per dimensions on page 18 UU 600# Masoneilan flange in stainless steel – as per dimensions on page 18 ¿ Confirm mounting conditions/nozzle diameter to ensure sufficient clearance. ¡ Always check dimensions if ANSI/EN flanges are not used. 7 1 28 2 3 4 5 6 7 8 9 10 11 12 13 14 15 MODEL CAGED NUMBER CONTINUED PROBE 6 | CONSTRUCTION CODES 0 Industrial K ASME B31.1 L ASME B31.3 M ASME B31.3 & NACE MR0175/MR0103 — NOT available with carbon steel flange N NACE MR0175/MR0103 — NOT available with carbon steel flange 7 | FLANGE OPTIONS 0 None 1 Offset (For use with AURORA) — 4” Only available with 3rd digit G and J and 4th digit 6 2 Offset with 1⁄2" NPT Vent (For use with AURORA) — 4” Only available with 3rd digit G and J and 4th digit 6 3 Offset with 3⁄4" NPT Vent (For use with AURORA) — 4” Only available with 3rd digit G and J and 4th digit 6 8 | MATERIAL OF CONSTRUCTION - MFG/NUT/ROD/INSULATION A 316 SS/316L SS B Hastelloy C C Monel R 316 SS/316L SS with Carbon Steel Flange S Hastelloy C with Carbon Steel Flange T Monel with Carbon Steel Flange 9 | SPACER MATERIAL 2 PEEK HT (+650 °F/+345 °C) 3 Ceramic (High Temp.>+800 °F/+425 °C) — Only available with 3rd digit J 4 Celazole® (+800 °F/+425 °C) — Only available with 3rd digit J 10 | O-RING MATERIALS/SEAL OPTIONS 0 Viton® GFLT — NOT available with 3rd digit J or L 2 Kalrez 4079 — NOT available with 3rd digit J or L 8 Aegis PF 128 (NACE) — NOT available with 3rd digit J or L A Kalrez 6375 — NOT available with 3rd digit J or L B HF Acid Probe — Only Available with 3rd digit G and 8th digit C D None/Glass Ceramic Alloy (Dual Seal Design with annunciator fitting) — NOT available with 3rd digit G N None/Glass Ceramic Alloy — NOT available with 3rd digit G 11 | PROBE SIZE/ELEMENT TYPE/FLUSHING CONNECTION 0 None 12 | SPECIAL OPTIONS — See page 36 1 2 3 4 5 6 Single Length Removable Probe 2-piece Segmented Probe 3-piece Segmented Probe 4-piece Segmented Probe 5-piece Enlarged Segmented Probe OD=2.5”(64mm) 6-piece Enlarged Segmented Probe OD=2.5”(64mm) 13 14 15 | INSERTION LENGTH inches (012 – 288) cm (030 – 732) XXX unit of measure determined by 2nd digit of model number 7 1 0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 MODEL SINGLE NUMBER ROD RIGID PROBE Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). 1 | TECHNOLOGY 7 ECLIPSE GWR Probes - Model 706 2 | MEASUREMENT SYSTEM A C English Metric 3 | CONFIGURATION/STYLE (RIGID) F M N Single Rod, Standard (+400 °F/200 °C) for in-tank applications — NOT available with 10th digit N or D Single Rod, High Pressure Probe with glass seal (+400 °F/+200 °C), for in-tank applications — Only available with 10th digit N or D Single Rod, High Temp/High Pressure with glass seal (+850 °F/+450 °C), for in-tank applications — Only available with 10th digit N or D 4 5 | PROCESS CONNECTION – SIZE/TYPE (consult factory for other process connections) ¿ Threaded 21 41 1" NPT Thread ¡ 2" NPT Thread 22 42 1" BSP (G1) Thread ¡ 2" BSP (G1) Thread ANSI Flanges 33 34 35 43 44 45 47 48 4K 4M 1 1⁄2" 150# ANSI RF ¿ ¬ 1 1⁄2" 300# ANSI RF ¿ ¬ 1 1⁄2" 600# ANSI RF ¿ ¬ 2" 150# ANSI RF ¿ 2" 300# ANSI RF ¿ 2" 600# ANSI RF ¿ 2" 900/1500# ANSI RF 2" 2500# ANSI RF 2" 600# ANSI RTJ 2" 900/1500# ANSI RTJ 4N 53 54 55 56 57 58 5K 5L 5M 2" 3" 3" 3" 3" 3" 3" 3" 3" 3" 2500# ANSI RTJ 150# ANSI RF 300# ANSI RF 600# ANSI RF 900# ANSI RF 1500# ANSI RF 2500# ANSI RF 600# ANSI RTJ 900# ANSI RTJ 1500# ANSI RTJ 5N 63 64 65 66 67 68 6K 6L 6M 6N 3" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 2500# ANSI RTJ 150# ANSI RF 300# ANSI RF 600# ANSI RF 900# ANSI RF 1500# ANSI RF 2500# ANSI RF 600# ANSI RTJ 900# ANSI RTJ 1500# ANSI RTJ 2500# ANSI RTJ EN Flanges CB CC CF CG DA DB DD DE DF DG DH DJ EA EB DN DN DN DN DN DN DN DN DN DN DN DN DN DN 40, 40, 40, 40, 50, 50, 50, 50, 50, 50, 50, 50, 80, 80, PN PN PN PN PN PN PN PN PN PN PN PN PN PN 16/25/40 EN 1092-1 TYPE A 63/100 EN 1092-1 TYPE B2 160 EN 1092-1 TYPE B2 250 EN 1092-1 TYPE B2 16 EN 1092-1 TYPE A ¿ 25/40 EN 1092-1 TYPE A ¿ 63 EN 1092-1 TYPE B2 ¿ 100 EN 1092-1 TYPE B2 ¿ 160 EN 1092-1 TYPE B2 250 EN 1092-1 TYPE B2 320 EN 1092-1 TYPE B2 400 EN 1092-1 TYPE B2 16 EN 1092-1 TYPE A ¿ 25/40 EN 1092-1 TYPE A ED EE EF EG EH E J FA FB FD FE FF FG FH FJ DN DN DN DN DN DN DN DN DN DN DN DN DN DN 80, PN 63 80, PN 100 80, PN 160 80, PN 250 80, PN 320 80, PN 400 100, PN 16 100, PN 25/40 100, PN 63 100, PN 100 100, PN 160 100, PN 250 100, PN 320 100, PN 400 EN EN EN EN EN EN EN EN EN EN EN EN EN EN 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE B2 B2 B2 B2 B2 B2 A A B2 B2 B2 B2 B2 B2 ¿ Confirm mounting conditions/nozzle diameter to ensure sufficient clearance. ¡ Not available with 3rd Digit N or 8th Digit P ¬ Not available with 3rd Digit M or N 7 1 30 2 3 4 5 6 7 8 9 10 11 12 13 14 15 MODEL SINGLE NUMBER ROD RIGID CONTINUED PROBE 6 | CONSTRUCTION CODES 0 Industrial K ASME B31.1 L ASME B31.3 M ASME B31.3 & NACE MR0175/MR0103 — NOT available with carbon steel flange N NACE MR0175/MR0103 — NOT available with carbon steel flange 7 | FLANGE OPTIONS 0 None 8 | MATERIAL OF CONSTRUCTION - MFG/NUT/ROD/INSULATION A 316 SS/316L SS B Hastelloy C C Monel F Faced Flange, PFA coated wetted surfaces — Only available with 3rd digit F P PFA coated rod — Only available with 3rd digit F R 316 SS/316L SS with Carbon Steel Flange S Hastelloy C with Carbon Steel Flange T Monel with Carbon Steel Flange 9 | SPACER MATERIAL 0 None – NOT available with 3rd Digit N 2 PEEK HT (+650 °F/+345 °C) — Only available with 3rd digit N 3 Ceramic (High Temp.>+800 °F/+425 °C) — Only available with 3rd digit N 4 Celazole® (+800 °F/+425 °C) — Only available with 3rd digit N 10 | O-RING MATERIALS/SEAL OPTIONS 0 Viton® GFLT — NOT available with 3rd digit M or N 2 Kalrez 4079 — NOT available with 3rd digit M or N 8 Aegis PF 128 (NACE) — NOT available with 3rd digit M or N A Kalrez 6375 — NOT available with 3rd digit M or N D None/Glass Ceramic Alloy Dual Seal with annunciator fitting — NOT available with 3rd digit F N None/Glass Ceramic Alloy Dual Seal — NOT available with 3rd digit F 11 | PROBE SIZE/ELEMENT TYPE/FLUSHING CONNECTION 0 Standard Single Rod 12 | SPECIAL OPTIONS Non-Removable Rod Only available with PFA Coated Probes(8th digit F or P) Removable Rod Not available with PFA Coated Probes(8th Digit F or P) 0 1 13 14 15 | INSERTION LENGTH inches (012 – 288) cm (030 – 732) XXX unit of measure determined by 2nd digit of model number 7 1 0 2 3 4 5 6 7 0 8 9 10 11 12 13 14 15 31 MODEL SINGLE NUMBER FLEXIBLE PROBE Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). 1 | TECHNOLOGY 7 ECLIPSE GWR Probes - Model 706 2 | MEASUREMENT SYSTEM A English C Metric 3 | SPECIALTY FLEXIBLE PROBES 1 Single Cable Flexible standard for in-tank applications (+400 °F/+200 °C) 2 Single Cable Flexible Light Duty Bulk Solids 3 Single Cable Flexible HP for in-tank applications (+400 °F/+200 °C) 4 Single Cable Flexible standard for chamber applications (+400 °F/+200 °C) — (Future) 6 Single Cable Flexible HTHP for chamber applications (+850 °F/+450 °C) 4 5 | PROCESS CONNECTION – SIZE/TYPE (consult factory for other process connections) Threaded 41 2" NPT Thread ANSI Flanges 43 44 45 47 48 4K 4M 4N 2" 2" 2" 2" 2" 2" 2" 2" 150# ANSI RF ¿ 300# ANSI RF ¿ 600# ANSI RF ¿ 900/1500# ANSI RF 2500# ANSI RF 600# ANSI RTJ 900/1500# ANSI RTJ 2500# ANSI RTJ EN Flanges DA DB DD DE DF DG DH DJ EA EB ED EE 42 DN 50, PN 16 DN 50, PN 25/40 DN 50, PN 63 DN 50, PN 100 DN 50, PN 160 DN 50, PN 250 DN 50, PN 320 DN 50, PN 400 DN 80, PN 16 DN 80, PN 25/40 DN 80, PN 63 DN 80, PN 100 53 54 55 56 57 58 5K 5L 5M 5N 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 2" BSP (G1) Thread 150# ANSI RF 300# ANSI RF 600# ANSI RF 900# ANSI RF 1500# ANSI RF 2500# ANSI RF 600# ANSI RTJ 900# ANSI RTJ 1500# ANSI RTJ 2500# ANSI RTJ EN 1092-1 TYPE A ¿ EN 1092-1 TYPE A ¿ EN 1092-1 TYPE B2 ¿ EN 1092-1 TYPE B2 ¿ EN 1092-1 TYPE B2 ¡ EN 1092-1 TYPE B2 ¡ EN 1092-1 TYPE B2 ¡ EN 1092-1 TYPE B2 ¡ EN 1092-1 TYPE A ¿ EN 1092-1 TYPE A EN 1092-1 TYPE B2 EN 1092-1 TYPE B2 EF EG EH E J FA FB FD FE FF FG FH FJ 63 64 65 66 67 68 6K 6L 6M 6N DN DN DN DN DN DN DN DN DN DN DN DN 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 80, PN 160 80, PN 250 80, PN 320 80, PN 400 100, PN 16 100, PN 25/40 100, PN 63 100, PN 100 100, PN 160 100, PN 250 100, PN 320 100, PN 400 150# ANSI RF 300# ANSI RF 600# ANSI RF 900# ANSI RF ¡ 1500# ANSI RF ¡ 2500# ANSI RF ¡ 600# ANSI RTJ ¡ 900# ANSI RTJ ¡ 1500# ANSI RTJ ¡ 2500# ANSI RTJ ¡ EN EN EN EN EN EN EN EN EN EN EN EN 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 1092-1 TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE TYPE B2 B2 B2 B2 A A B2 B2 B2 B2 B2 B2 ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¡ ¿ Confirm mounting conditions/nozzle diameter to ensure sufficient clearance. ¡ Only available with 3rd Digit 3 or 6 7 1 32 2 3 4 5 6 7 8 9 10 11 12 13 14 15 MODEL SINGLE NUMBER FLEXIBLE CONTINUED PROBE 6 | CONSTRUCTION CODES 0 Industrial 7 | FLANGE OPTIONS 0 None 8 | MATERIAL OF CONSTRUCTION - MFG/NUT/ROD/INSULATION A 316 SS/316L SS F Faced Flange, PFA Coated Wetted Surfaces — Only available with 3rd digit 1 R 316 SS/316L SS with Carbon Steel Flange 9 | SPACER MATERIAL 0 None 4 Celazole® — Only available with 3rd digit 6 10 | O-RING MATERIALS/SEAL OPTIONS 0 Viton® GFLT 2 Kalrez 4079 8 Aegis PF 128 (NACE) A Kalrez 6375 N None/Glass Ceramic Alloy Dual Seal — Only available with 3rd digit 6 11 | PROBE SIZE/ELEMENT TYPE/FLUSHING CONNECTION 3 Flexible Cable Probe 12 | SPECIAL OPTIONS 0 Non-removable Probe Cable Only available with 3rd digit 2 or 8th digit F 1 Removable Single-piece Probe Cable Only available with 3rd digit 1, 3 and 6 13 14 15 | INSERTION LENGTH feet (003 – 100) meters (001 – 030) XXX unit of measure determined by 2nd digit of model number 7 1 2 3 4 5 0 0 6 7 0 8 9 3 10 11 12 13 14 15 33 MODEL TWIN NUMBER FLEXIBLE PROBE Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). 1 | TECHNOLOGY 7 ECLIPSE GWR Probes - Model 706 2 | MEASUREMENT SYSTEM A English C Metric 3 | SPECIALTY FLEXIBLE PROBES 5 Twin Flexible Light Duty Bulk Solids with FEP Webbing 7 Twin Flexible - 316 SS with FEP Webbing 4 5 | PROCESS CONNECTION – SIZE/TYPE (consult factory for other process connections) Threaded ¿ 21 41 1" NPT Thread (7yF and 7yM only) 2" NPT Thread 22 42 1" BSP (G1) Thread (7yF and 7yM only) 2" BSP (G1) Thread ANSI Flanges 53 3" 150 lbs. ANSI RF 54 3" 300 lbs. ANSI RF 55 3" 600 lbs. ANSI RF 63 4" 150 lbs. ANSI RF 64 4" 300 lbs. ANSI RF 65 4" 600 lbs. ANSI RF EN Flanges EA DN 80, PN 16 EN 1092-1 TYPE A EB DN 80, PN 25/40 EN 1092-1 TYPE A ED DN 80, PN 63 EN 1092-1 TYPE B2 EE DN 80, PN 100 EN 1092-1 TYPE B2 FA DN 100, PN 16 EN 1092-1 TYPE A FB DN 100, PN 25/40 EN 1092-1 TYPE A FD DN 100, PN 63 EN 1092-1 TYPE B2 FE DN 100, PN 100 EN 1092-1 TYPE B2 ¿ Confirm mounting conditions/nozzle diameter to ensure sufficient clearance. 7 1 34 2 3 4 5 6 7 8 9 10 11 12 13 14 15 MODEL TWIN NUMBER CONTINUED PROBE FLEXIBLE 6 | CONSTRUCTION CODES Industrial 0 7 | FLANGE OPTIONS 0 None 8 | MATERIAL OF CONSTRUCTION - MFG/NUT/ROD/INSULATION A 316 SS/316L SS R 316 SS/316L SS with Carbon Steel Flange 9 | SPACER MATERIAL None 0 10 | O-RING MATERIALS/SEAL OPTIONS 0 Viton® GFLT 2 Kalrez 4079 — Only available with 3rd digit 7 8 Aegis PF 128 (NACE) — Only available with 3rd digit 7 A Kalrez 6375 — Only available with 3rd digit 7 11 | PROBE SIZE/ELEMENT TYPE/FLUSHING CONNECTION 3 Flexible Cable Probe 12 | SPECIAL OPTIONS 0 None 13 14 15 | INSERTION LENGTH feet (003 – 100) meters (001 – 030) XXX unit of measure determined by 2nd digit of model number 7 1 2 3 4 5 0 0 6 7 0 8 9 10 3 0 11 12 13 14 15 35 SEGMENTED PROBE 12th MODEL DIGIT OF OPTIONS NUMBER Probe Model One Segment Two Segments Three Segments Four Segments Five Segments Six Segments Coaxial Models 7yD, 7yP and 7yT (Enlarged versions only) (3", DN 80 Process Connections and larger) 24 – 72" (60 – 182 cm) 48 – 144" (120 – 365 cm) 72 – 216" (180 – 548 cm) 96 – 288" (240 – 731 cm) 120 – 360" (305 – 914 cm) 144 – 396" (365 – 999 cm) Caged Models 7yG, 7yL and 7yJ 12 – 120" (30 – 305 cm) 24 – 240" (60 – 610 cm) 36 – 288" (90 – 732 cm) 48 – 288" (120 – 732 cm) Not Available Not Available NOTE: Segments will be evenly divided over the length of the probe. 36 COAXIAL INCHES 3.38 (86) PROBE DIMENSIONS (mm) 4.18 (106) 3.77 (96) 3.38 (86) 4.18 (106) 3.38 (86) 3.77 (96) 3.77 (96) 9.30 (236) 2 cable entries Optional Flushing Port 1/4" NPT 45° 4.46 (113) Mounting Flange 9.30 (236) 9.30 (236) 45° 2 cable entries 3.0 (76 mm) typical 4.18 (106) 45° 2 cable entries Optional Flushing Port 1/4" NPT Optional Flushing Port 1/4" NPT 7.76 (197) 10.45 (265) 3.0 (76 mm) typical 3.0 (76 mm) typical Probe Insertion Length Model 7yT with flanged connection 3.38 (86) Mounting Flange Probe Insertion Length Model 7yP with flanged connection Probe Insertion Length Model 7yD with flanged connection F 4.18 (106) B 3.77 (96) 9.30 (236) 2 cable entries Mounting Flange A 45° ⌀ 2.5 C Model 7yS Coaxial GWR Probe, End View (63.5) E A B D Coaxial Probe Slots 11.55 (293) Coaxial GWR Probe, End View Inches (mm) Dim. Mounting Flange Probe Insertion Length Model 7yS with flanged connection Small Diameter Segmented Enlarged Coaxial Probe Enlarged (standard) A 0.88 (22.5) 1.75 (45) - SST 1.92 (49) - HC and Monel B C D E F 0.31 (8) 4.08 (100) 0.15 (4) 3.78 (96) 1.25 (31.75) 0.63 (16) 6.05 (153) 0.30 (8) 5.45 (138) — 37 CAGED INCHES 3.38 (86) PROBE DIMENSIONS (mm) 3.38 (86) 3.38 (86) 4.18 (106) 4.18 (106) 3.77 (96) 3.77 (96) 3.77 (96) 9.30 (236) 9.30 (236) 9.30 (236) 45° Mounting Flange D Mounting Flange D Probe Insertion Length Probe Insertion Length L L Model 7yG with flanged connection 10.45 (265) 6.39 (162) 4.70 (119) Mounting Flange 45° 2 cable entries 2 cable entries 45° 2 cable entries 38 4.18 (106) Model 7yL with flanged connection D L Probe Insertion Length Model 7yJ with flanged connection Cage Size Probe Rod Diameter (D) Spacer Length (L) 2" 0.5 to 0.75" (13 to 19 mm) 1.82" (46 mm) 3" 0.75 to 1.13" (19 to 29 mm) 2.64" (67 mm) 4" 1.05 to 1.50" (27 to 38 mm) 3.60" (91 mm) SINGLE INCHES 3.38 (86) ROD RIGID PROBE DIMENSIONS (mm) 3.38 (86) 3.38 (86) 4.18 (106) 4.18 (106) 4.18 (106) 3.77 (96) 3.77 (96) 3.77 (96) 9.30 (236) 9.30 (236) 9.30 (236) 45° 2 cable entries 2 cable entries 45° 2 cable entries 45° 4.53 (115) Mounting Flange Mounting Flange ⌀ .38 Probe Insertion Length (9.6) Model 7yF with flanged connection 10.45 (265) 8.38 (213) Mounting Flange ⌀ .38 (9.6) Probe Insertion Length Model 7yM with flanged connection ⌀ .50 (13) Probe Insertion Length Model 7yN with flanged connection 39 SINGLE INCHES FLEXIBLE PROBE (mm) 3.38 (86) DIMENSIONS 3.38 (86) 4.18 (106) 3.38 (86) 4.18 (106) 4.18 (106) 3.77 (96) 3.77 (96) 3.77 (96) 9.30 (236) 9.30 (236) 9.30 (236) 45° 2 cable entries 2 cable entries 45° 45° 2 cable entries 4.53 (115) 10.45 (265) Mounting Flange 10.45 (265) Mounting Flange Probe Insertion Length ⌀ 2.0 (51) ⌀ 0.5 (0.19) ⌀ 2.0 (51) ⌀ 2.0 (51) 3.88 (99) Probe Insertion Length Model 7y3 with flanged connection 0.75 (19) Model 7y1 with flanged connection 3.38 (86) Mounting Flange 3.38 (86) 4.18 (106) 4.18 (106) 9.30 (236) 9.30 (236) 6 (152) 2 cable entries 45° 2 cable entries Ø2 (51) 45° 5.46 (139) 4.70 (119) Mounting Flange Mounting Flange ⌀ 2.0 (51) ⌀ 2.0 (51) 40 6.0 (152) 3.77 (96) 3.77 (96) Model 7y4 with flanged connection Model 7y6 with flanged connection 6.0 (152) Probe Insertion Length Probe Insertion Length 6.0 (152) Model 7y2 with flanged connection Probe Insertion Length 6.0 (152) 7x2: SST Weight 5 lbs (2.25 kg) order code: 004-8778-001 (2) 010-1731-001 “IN TANK” MOUNTING STANDARD SINGLE ROD PROBE CONSIDERATIONS For Rigid Models 7yF, M, N and Flexible Models 7y1, 2, 4 and 6 1. Turbulence The bottom of rigid probes should be stabilized if turbulence will cause a deflection of more than 3" (75 mm) at the end of a 10' (3 m) length. The probe should not make contact with metal. 2. Nozzle 3. Metallic (conductive) obstructions in tank. Although it depends on the transmitter configuration, objects in the proximity of the probe can cause erroneous readings. Please refer to the table below for guidelines, but please contact the factory with any questions as the distances shown can be reduced with the use of PACTware™. Distance to probe Acceptable objects < 6" (150 mm) Continuous, smooth, parallel, conductive surface (e.g. metal tank wall); probe should not touch tank wall > 6" (150 mm) < 1"/DN25 diameter pipe and beams, ladder rungs > 12" (300 mm) < 3"/DN80 diameter pipe and beams, concrete walls > 18" (450 mm) All remaining objects Single rod performance in nozzles can be improved by ensuring the following: • Nozzle must be 2" (50 mm) or larger diameter. • Nozzle should be as short as possible. • Nozzle inside diameter (A) should be ≥ to nozzle height (B). • If this is not the case, adjustments to BLOCKING DISTANCE and/or SENSITIVITY parameters may be required. Note: A metal stillwell/cage of max. 6"/DN150 size or a metal tank wall parallel to the probe within 6" (150 mm) will allow the unit to operate accurately in media with dielectrics down to εr 1.4. 4. Non-metallic vessels A B A metal flange is highly recommended for optimum performance in plastic vessels. NOTE: Singe rod probes must be used in metallic vessels or stillwell to maintain CE noise immunity. Shutdown /Overfill protection Correct Installation Special consideration is necessary in any shutdown/ overfill protection application where single rod GWR probes are used. To ensure proper measurement, use Overfill Capable single rod probes, such as the Model 7yG, L, or J Caged probes in the appropriate cage/ chamber/stillwell. Mounting Considerations for Single Flexible probes measuring Bulk Solids The Model 7y2 Bulk Solid probe is designed for a 3000 lb. (1360 kg) pull-down force for use in applications such as sand, plastic pellets, and grains. Pipe reducers should not be used • To reduce excessive stresses on the top of the vessel, do not secure the metal probe weight to the bottom of the vessel. • Mount the probe at least 12 inches from the wall. The ideal location is 1⁄4 to 1⁄2 the diameter to average the angle of repose. 41 TWIN FLEXIBLE INCHES PROBE (mm) DIMENSIONS 3.38 (86) 4.18 (106) 3.38 (86) 4.18 (106) 3.77 (96) 3.77 (96) 9.30 (236) 6.00 (152) 9.30 (236) Ø 2.00 (51) 2 cable entries 45° 2 cable entries 45° 5.31 (135) Mounting Flange 4.54 (115) Mounting Flange 7y5: SST Weight 5 lbs (2.25 kg) order code: 004-8778-002 + 2 x 010-1731-001 Probe Insertion Length 0.875 (22.2) Probe Insertion Length Ø 0.50 (13) Rods 0.248 (6.3) Twin Flexible GWR Probe end view “IN TANK” MOUNTING TWIN Model 7y5 with flanged connection FLEXIBLE PROBE CONSIDERATIONS For Models 7y7 1. Turbulence The bottom of Twin Flexible probes can be secured to the bottom of the vessel by using the TFE weight at the bottom of the probe. The TFE weight has a 1 ⁄2" (13 mm) hole that can be utilize to “u-bolt” the probe to the bottom of the vessel. The probe should not make contact with metal. 2. Nozzle Twin Flexible probe performance in nozzles can be improved by ensuring the following: • Nozzle should be 3" (DN80) diameter or larger. • Nozzle should be as short as possible. 42 Model 7y7 with flanged connection 3. Metallic (conductive) obstructions in tank. Mount the Twin Flexible probe more than 1" (25 mm) from any metallic object/vessel wall. Mounting Considerations for Twin Flexible Model 7y5 probes measuring Bulk Solids: The Model 7y5 Bulk Solid probe is designed for a 3000 lb. (1360 kg) pull-down force for use in applications such as sand, plastic pellets, and grains. • To reduce excessive stresses on the top of the vessel, do not secure the metal probe weight to the bottom of the vessel. • Mount the probe at least 12 inches from the wall. The ideal location is 1⁄4 to 1⁄2 the diameter to average the angle of repose. AURORA ® CHAMBER The Orion Instruments® Aurora® is the patented combination of the ECLIPSE Guided Wave Radar transmitter and a Magnetic Level Indicator (MLI). The integration of these two independent technologies provides excellent redundancy. A custom float positioned within the AURORA chamber travels up and down following level changes. The float contains an internal group of magnets that are “coupled” with magnets in the flags of the visual indicator mounted on the outside of the chamber. As the float moves, the flags rotate to expose the color of their opposite side. The position where the flag’s color changes corresponds to a point on the measuring scale indicating true level. In addition to this external visual indicator operated by the AURORA internal float, the ECLIPSE Model 706 transmitter reflects electromagnetic radar pulses directly off the liquid surface providing a real-time continuous level output. Visual Indication Range Center to Center Visual Indication Range Refer to Orion Instruments® Sales Bulletin ORI-138 for details and additional options on AURORA chambers. Regardless of whether a standard chamber or AURORA chamber is being used it is important to remember: • Ensure that the Model 706 probe extends at least 4" (100 mm) past the lower process connection of the chamber • Utilize Overfill-capable probes for optimal GWR performance. Center to Center Visual Indication Range Center to Center 43 QUALITY The quality assurance system in place at MAGNETROL guarantees the highest level The MAGNETROL quality assurance system is registered to ISO 9001 affirming its com- of quality throughout the company. MAGNETROL is committed to providing full mitment to known international quality standards providing the strongest assurance customer satisfaction both in quality products and quality service. of product/service quality available. Several Models of ECLIPSE Guided Wave Radar Transmitters are available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP Expedite Ship Plan Models covered by ESP service are color coded in the selection data charts. ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. WARRANTY All MAGNETROL electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, MAGNETROL will repair or replace the control at no cost to the purchaser (or owner) other than transportation. MAGNETROL shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some MAGNETROL products. For additional information, see Instruction Manual 57-606. ECLIPSE Guided Wave Radar transmitters may be protected by one or more of the following U.S. Patent Nos. US 6,062,095: US 6,247,362; US 6,588,272; US 6,626,038; US 6,640,629; US 6,642,807; US 6,690,320; US 6,750,808; US 6,801,157; US 6,867,729; US 6,879,282; 6,906,662. May depend on model. Other patents pending. 705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000 • Fax 630-969-9489 [email protected] • www.magnetrol.com Copyright © 2016 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. Magnetrol & Magnetrol logotype, Orion Instruments & Orion Instruments logotype, ECLIPSE and MODULEVEL are registered trademarks of Magnetrol International, Incorporated. CSA logotype is a registered trademark of Canadian Standards Association. Eckardt is a registered trademark of Invensys Process Systems. Fisher is a registered trademark of Emerson Process Management. FOUNDATION fieldbus logo is a registered trademark of the Fieldbus Foundation. HART is a registered trademark of the HART Communication Foundation. Hastelloy is a registered trademark of Haynes International, Inc. Masoneilan is a registered trademark of Dresser Industries, Inc. Monel is a registered trademark of International Nickel Co. PACTware is trademark of PACTware Consortium. Teflon is a registered trademark of DuPont. Tokyo Keiso is a registered trademark of Tokyo Keiso Co., Ltd. Viton and Kalrez are registered trademarks of DuPont Performance Elastomers. BULLETIN: 57-106.10 EFFECTIVE: June 2016 SUPERCEDES: February 2016