` FEATURES High efficiency: 84.5% @1.0V/50A Size: 58.4mm x 22.8mm x 9.5mm (2.30”x0.90”x0.37”) Industry standard pin out Fixed frequency operation Input UVLO, Output OTP, OCP, OVP Output voltage trim:-20%,+10% Monotonic startup into normal and pre-biased loads Secondary side control, very fast transient response 2250V Isolation and basic insulation No minimum load required No negative current during power or enable on/off ISO 9001, TL 9000, ISO 14001, QS 9000, OHSAS 18001 certified manufacturing facility UL/cUL 60950 (US & Canada) recognized. Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 1.0V/50A out The Delphi Series E48SH Eighth Brick, 48V input, single output, isolated DC/DC converters are the latest offering from a world leader in power systems technology and manufacturing ― Delta Electronics, Inc. This product family is available in either a through-hole or surface-mounted package and provides up to 120 watts of power or 50A of output current (1.0V and below) in an industry standard footprint and pinout. The E48SH converter operates from an input voltage of 36V to 75V and is available in output voltages from 1.0V to 15V. Efficiency is up to 84.5% for 1.0V output at 50A full load. With creative design technology and optimization of component placement, these converters possess outstanding electrical and thermal performance, as well as extremely high reliability under highly stressful operating conditions. All models are fully protected from abnormal input/output voltage, current, and temperature conditions. The Delphi Series converters meet all safety requirements with basic insulation. DATASHEET DS_E48SH1R050_11012013 OPTIONS Positive On/Off logic Short pin lengths available External Synchronization Output OVP latch mode Output OCP latch mode APPLICATIONS Telecom/DataCom Wireless Networks Optical Network Equipment Server and Data Storage Industrial/Test Equipment TECHNICAL SPECIFICATIONS (TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.) PARAMETER NOTES and CONDITIONS E48SH1R050 Min. ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous Transient (100ms) Operating Hot Spot Temperature Storage Temperature Input/Output Isolation Voltage INPUT CHARACTERISTICS Operating Input Voltage Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Hysteresis Voltage Maximum Input Current No-Load Input Current Off Converter Input Current 2 Inrush Current(I t) Input Reflected-Ripple Current Input Voltage Ripple Rejection OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Load Over Line Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception DYNAMIC CHARACTERISTICS Output Voltage Current Transient Positive Step Change in Output Current Negative Step Change in Output Current Settling Time (within 1% Vout nominal) Turn-On Transient Start-Up Time, From On/Off Control Start-Up Time, From Input Maximum Output Capacitance EFFICIENCY 100% Load 60% Load ISOLATION CHARACTERISTICS Input to Output Isolation Resistance Isolation Capacitance FEATURE CHARACTERISTICS Switching Frequency ON/OFF Control, Negative Remote On/Off logic Logic Low (Module On) Logic High (Module Off) ON/OFF Control, Positive Remote On/Off logic Logic Low (Module Off) Logic High (Module On) ON/OFF Current (for both remote on/off logic) Leakage Current (for both remote on/off logic) Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection GENERAL SPECIFICATIONS MTBF Weight Over-Temperature Shutdown 100ms Refer to Figure 21 for measuring point Typ. -40 -55 36 33 31 1 34 32 2 100% Load, 36Vin 35 3 P-P thru 12µH inductor, 5Hz to 20MHz 120 Hz Vin=48V, Io=Io.max, Tc=25°C Io=Io,min to Io,max Vin=36V to 75V Tc=-40°C to 85°C over sample load, line and temperature 5Hz to 20MHz bandwidth Full Load, 400µF ceramic Full Load, 400µF ceramic Output Voltage 10% Low Max. Units 80 100 125 125 2250 Vdc Vdc °C °C Vdc 75 Vdc 35 33 3 2.0 Vdc Vdc Vdc A mA mA 2 As mA dB 10 1 20 50 0.990 1.000 1.010 Vdc ±3 ±3 ±15 ±10 ±10 1.020 mV mV mV V 40 20 50 135 mV mV A % 0.980 20 5 0 105 48V, 2310uF electrolytic load cap, 1A/µs 50% Io.max to 75% Io.max 75% Io.max to 50% Io.max 50 50 50 mV mV us 13 13 ms ms µF Full load; no overshoot of Vout at startup 40000 84.5 86.5 % % 2250 10 Von/off at Ion/off=1.0mA Von/off at Ion/off=0.0 µA Von/off at Ion/off=1.0mA Von/off at Ion/off=0.0 µA Ion/off at Von/off=0.0V Logic High, Von/off=15V Across Pins 9 & 5, Pout ≦ max rated power Pout ≦ max rated power Over full temp range; % of nominal Vout Io=80% of Io, max; 300LFM @25℃ Refer to Figure 21 for measuring point 1000 Vdc MΩ pF 240 kHz -0.7 2.4 0.8 50 V V -0.7 2.4 0.8 50 1 50 10 10 150 V V mA uA % % % -20 130 4.66 25 130 M hours grams °C E48SH1R050_11012013 2 ELECTRICAL CHARACTERISTICS CURVES POWER DISSIPATION(W) EFFICIENCY (%) 1 90 85 75Vin 48Vin 80 36Vin 75 70 65 5 10 15 20 25 30 35 40 45 50 OUTPUT CURRENT(%) 15.0 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 48Vin 36Vin 75Vin 5 10 15 20 25 30 35 40 45 50 OUTPUT CURRENT(%) Figure 1: Efficiency vs. load current for minimum, nominal, and maximum input voltage at 25°C Figure 2: Power dissipation vs. load current for minimum, nominal, and maximum input voltage at 25°C. 2.0 1.8 INPUT CURRENT (A) 1 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 30 35 40 45 50 55 60 65 70 75 INPUT VOLTAGE (V) Figure 3: Typical full load input characteristics at room temperature E48SH1R050_11012013 3 ELECTRICAL CHARACTERISTICS CURVES For Negative Remote On/Off Logic Figure 4: Turn-on transient at zero load current (5ms/div). Vin=48V.Top Trace: Vout, 0.5V/div; Bottom Trace: ON/OFF input, 5V/div Figure 5: Turn-on transient at full rated load current (constant current load) (5ms/div). Vin=48V.Top Trace: Vout, 0.5V/div; Bottom Trace: ON/OFF input, 5V/div For Input Voltage Start up Figure 6: Turn-on transient at zero load current (5 ms/div). Vin=48V.Top Trace: Vout, 0.5V/div, Bottom Trace: input voltage, 20V/div Figure 7: Turn-on transient at full rated load current (constant current load) (5 ms/div). Vin=48V. Top Trace: Vout, 0.5V/div; Bottom Trace: input voltage,20V/div E48SH1R050_11012013 4 ELECTRICAL CHARACTERISTICS CURVES Figure 8: Output voltage response to step-change in load current (75%-50% of Io, max; di/dt = 1A/µs). Load cap: 2310uF electrolytic capacitor. Top Trace: Vout (20mV/div, 100us/div), Bottom Trace: Io (20A/div, 100us/div), Scope measurement should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module. Figure 9: Output voltage response to step-change in load current (50%-75% of Io, max; di/dt = 1A/µs). Load cap: 2310uF electrolytic capacitor. Top Trace: Vout (20mV/div, 100us/div), Bottom Trace: Io (20A/div, 100us/div), Scope measurement should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module. Figure 10: Test set-up diagram showing measurement points for Input Terminal Ripple Current and Input Reflected Ripple Current. Note: Measured input reflected-ripple current with a simulated source Inductance (LTEST) of 12 μH. Capacitor Cs offset possible battery impedance. Measure current as shown above Figure 11: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 12µH source impedance and 33µF electrolytic capacitor (200 mA/div, 2us/div). E48SH1R050_11012013 5 ELECTRICAL CHARACTERISTICS CURVES Figure 12: Input reflected ripple current, is, through a 12µH source inductor at nominal input voltage and rated load current (20 mA/div, 2us/div). Figure 13: Output voltage noise and ripple measurement test setup 1.2 OUTPUT VOLTAGE(V) 1 1.0 0.8 0.6 0.4 0.2 0.0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 LOAD CURRENT(A) Figure 14: Output voltage ripple at nominal input voltage and rated load current (Io=50A)(10 mV/div, 2us/div) Load capacitance: 400µF ceramic capacitor. Bandwidth: 20 MHz. Scope measurements should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module. Figure 15: Output voltage vs. load current showing typical current limit curves and converter shutdown points. E48SH1R050_11012013 6 DESIGN CONSIDERATIONS Safety Considerations Input Source Impedance The impedance of the input source connecting to the DC/DC power modules will interact with the modules and affect the stability. A low ac-impedance input source is recommended. If the source inductance is more than a few μH, we advise adding a 10 to 100 μF electrolytic capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the input of the module to improve the stability. Layout and EMC Considerations Delta’s DC/DC power modules are designed to operate in a wide variety of systems and applications. For design assistance with EMC compliance and related PWB layout issues, please contact Delta’s technical support team. An external input filter module is available for easier EMC compliance design. Below is the reference design for an input filter tested with E48SH1R050XXXX to meet class B in CISSPR 22. Schematic and Components List Cin is 33uF*2 low ESR Aluminum cap; CX is 33uF Aluminum cap; CY1 and CY2 are 2.2nF ceramic caps; L1 is common-mode inductor, L1=0.59mH; Test Result: Vin=48V, Io=50A, The power module must be installed in compliance with the spacing and separation requirements of the end-user’s safety agency standard, i.e., UL60950-1, CSA C22.2 NO. 60950-1 2nd and IEC 60950-1 2nd : 2005 and EN 60950-1 2nd: 2006+A11+A1: 2010, if the system in which the power module is to be used must meet safety agency requirements. Basic insulation based on 75 Vdc input is provided between the input and output of the module for the purpose of applying insulation requirements when the input to this DC-to-DC converter is identified as TNV-2 or SELV. An additional evaluation is needed if the source is other than TNV-2 or SELV. When the input source is SELV circuit, the power module meets SELV (safety extra-low voltage) requirements. If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 75 Vdc, for the module’s output to meet SELV requirements, all of the following must be met: The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible.. A SELV reliability test is conducted on the system where the module is used, in combination with the module, to ensure that under a single fault, hazardous voltage does not appear at the module’s output. When installed into a Class II equipment (without grounding), spacing consideration should be given to the end-use installation, as the spacing between the module and mounting surface have not been evaluated. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. This power module is not internally fused. To achieve optimum safety and system protection, an input line fuse is highly recommended. The safety agencies require a normal-blow fuse with 20A maximum rating to be installed in the ungrounded lead. A lower rated fuse can be used based on the maximum inrush transient energy and maximum input current. Soldering and Cleaning Considerations Yellow line is quasi peak mode; Blue line is average mode Post solder cleaning is usually the final board assembly process before the board or system undergoes electrical testing. Inadequate cleaning and/or drying may lower the reliability of a power module and severely affect the finished circuit board assembly test. Adequate cleaning and/or drying is especially important for un-encapsulated and/or open frame type power modules. For assistance on appropriate soldering and cleaning procedures, please contact Delta’s technical support team. E48SH1R050_11012013 7 FEATURES DESCRIPTIONS Vi(+) Over-Current Protection Sense(+) The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. When the output current exceeds the OCP set point, the modules will automatically shut down and enter hiccup mode. ON/OFF Sense(-) Vi(-) During hiccup, the modules will try to restart after shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is corrected. Vo(+) Vo(-) Figure 16: Remote on/off implementation Over-Voltage Protection Remote Sense The modules include an internal output over-voltage protection circuit, which monitors the voltage on the output terminals. If this voltage exceeds the over-voltage set point, the module will shut down and restart after 200mS. Latch-off mode is optional. Under latch off mode the over-voltage latch is reset by either cycling the input power or by toggling the on/off signal for one second. Remote sense compensates for voltage drops on the output by sensing the actual output voltage at the point of load. The voltage between the remote sense pins and the output terminals must not exceed the output voltage sense range given here: Over-Temperature Protection This limit includes any increase in voltage due to remote sense compensation and output voltage set point adjustment (trim). The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the over-temperature threshold the module will shut down. [Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] ≤ 10% × Vout Vi(+) The module will try to restart after shutdown. If the over-temperature condition still exists during restart, the module will shut down again. This restart trial will continue until the temperature is within specification. Remote On/Off The remote on/off feature on the module can be either negative or positive logic. Negative logic turns the module on during a logic low and off during a logic high. Positive logic turns the modules on during a logic high and off during a logic low. Remote on/off can be controlled by an external switch between the on/off terminal and the Vi(-) terminal. The switch can be an open collector or open drain. For negative logic if the remote on/off feature is not used, please short the on/off pin to Vi(-). For positive logic if the remote on/off feature is not used, please leave the on/off pin to floating. Vo(+) Sense(+) Sense(-) Vi(-) Contact Resistance Vo(-) Contact and Distribution Losses Figure 17: Effective circuit configuration for remote sense operation If the remote sense feature is not used to regulate the output at the point of load, please connect SENSE(+) to Vo(+) and SENSE(–) to Vo(–) at the module. The output voltage can be increased by both the remote sense and the trim; however, the maximum increase is the larger of either the remote sense or the trim, not the sum of both. When using remote sense and trim, the output voltage of the module is usually increased, which increases the power output of the module with the same output current. Care should be taken to ensure that the maximum output power does not exceed the maximum rated power. E48SH1R050_11012013 8 FEATURES DESCRIPTIONS (CON.) Output Voltage Adjustment (TRIM) To increase or decrease the output voltage set point, the modules may be connected with an external resistor between the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used. If the external resistor is connected between the TRIM and SENSE (+) the output voltage set point increases (Fig. 19). The external resistor value required to obtain a percentage output voltage change △% is defined as: Rtrim up 5.11 Vo (100 ) 511 10.22K 0.6215 Ex. When Trim-up +10%(1.0V×1.1=1.1V) Rtrim up 5.11 1.0 (100 10) 511 10.22 30.4K 0.6215 10 10 The output voltage can be increased by both the remote sense and the trim, however the maximum increase is the larger of either the remote sense or the trim, not the sum of both. Figure 18: Circuit configuration for trim-down (decrease output voltage) If the external resistor is connected between the TRIM and SENSE (-) pins, the output voltage set point decreases (Fig.18). The external resistor value required to obtain a percentage of output voltage change △% is defined as: Rtrim down 511 10.2K Ex. When Trim-down -20 %( 1.0V×0.8=0.8V) Rtrim down When using remote sense and trim, the output voltage of the module is usually increased, which increases the power output of the module with the same output current. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. Frequency Synchronization This product family can be synchronized with external clock signal to the TRIM pin. This reduces system noise and interference in multiple converter systems. 511 10.2 15.4K 20 Figure 19: Circuit configuration for trim-up (increase output voltage) E48SH1R050_11012013 9 THERMAL CONSIDERATIONS Thermal Derating Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer. Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel. Heat can be removed by increasing airflow over the module. To enhance system reliability; the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected. THERMAL CURVES Thermal Testing Setup Delta’s DC/DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted. The following figure shows the wind tunnel characterization setup. The power module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is constantly kept at 6.35mm (0.25’’). Figure 21: Case temperature measurement location. Pin locations are for reference only. *The allowed maximum hot spot temperature is defined at 125℃ E48SH1R050(Standard) Output Current vs. Ambient Temperature and Air Velocity @Vin = 48V (Transverse Orientation) Output Current(A) 50 45 PWB FACING PWB Natural Convection 40 100LFM MODULE 35 200LFM 300LFM 30 400LFM 25 500LFM 20 600LFM 15 AIR VELOCITY AND AMBIENT TEMPERATURE MEASURED BELOW THE MODULE 10 50.8 (2.0”) 5 0 AIR FLOW 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (℃) Figure 22: Output current vs. ambient temperature and air velocity @Vin= 48V (Transverse Orientation) 12.7 (0.5”) Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches) Figure 20: Wind tunnel test setup E48SH1R050_11012013 10 PICK AND PLACE LOCATION SURFACE-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD) E48SH1R050_11012013 11 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE Note: The temperature refers to the pin of E48SH, measured on the pin +Vout joint. LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE Temp. Peak Temp. 240 ~ 245 ℃ 217℃ Ramp down max. 4℃/sec. 200℃ Preheat time 100~140 sec. 150℃ Time Limited 90 sec. above 217℃ Ramp up max. 3℃/sec. 25℃ Time Note: The temperature refers to the pin of E48SH, measured on the pin +Vout joint. E48SH1R050_11012013 12 MECHANICAL DRAWING (WITHOUT HEATSPREADER) SURFACE-MOUNT MODULE Pin No. 1 2 3 4 5 6 7 8 Name +Vin ON/OFF -Vin -Vout -Sense Trim +Sense +Vout THROUGH-HOLE MODULE Function Positive input voltage Remote ON/OFF Negative input voltage Negative output voltage Negative remote sense Output voltage trim Positive remote sense Positive output voltage Pin Specification: Pins 1-3,5-7 Pins 4 & 8 1.00mm (0.040”) diameter 2. 1.50mm (0.060”) diameter All pins are copper with Tin plating. E48SH1R050_11012013 13 PART NUMBERING SYSTEM E 48 S H 1R0 50 N R Type of Product Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Length E- Eighth Brick 48-36V~75V S- Single 50 - 50A N- Negative R- 0.170” P- Positive N- 0.145” K- 0.110” M- SMD H-50A series 1R0 - 1.0V F A Option Code F- RoHS 6/6 (Lead Free) A- Standard Functions MODEL LIST MODEL NAME E48SH1R050NRFA INPUT 36V~75V OUTPUT 2.0A 1.0V EFF @ 100% LOAD 50A 84.5% Default remote on/off logic is negative and pin length is 0.170” For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office. CONTACT: www.deltaww.com/dcdc USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964 Email: [email protected] Europe: Telephone: +31-20-655-0967 Fax: +31-20-655-0999 Email: [email protected] Asia & the rest of world: Telephone: +886 3 4526107 x 6220~6224 Fax: +886 3 4513485 Email: [email protected] WARRANTY Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. E48SH1R050_11012013 14