AOZ8252 One-line Bidirectional TVS Diode General Description Features The AOZ8252 is a one-line bidirectional transient voltage suppressor diode designed to protect high speed data lines and voltage sensitive electronics from high transient conditions and ESD. ESD protection for high-speed data lines: This device incorporates one bidirectional TVS diode in an ultra-small 0201 footprint package. It may be used to meet the ESD immunity requirements of IEC 61000-4-2, Level 4 (±15 kV air, ±15 kV contact discharge). Small package saves board space The AOZ8252 comes in an RoHS compliant package and is rated over a -40 °C to +85 °C ambient temperature range. Pb-free device The ultra-small 0.62 mm x 0.32 mm 0201 footprint package makes the AOZ8252 ideal for applications where PCB space is a premium. The small size and high ESD protection makes it ideal for protecting voltage sensitive electronics from high transient conditions and ESD. Portable handheld devices – Exceeds: IEC 61000-4-2 (ESD) ±30 kV (air), ±25 kV (contact) – Human Body Model (HBM) ±25 kV Low capacitance: 0.3 pF Low clamping voltage Low operating voltage: 5.0 V Applications Keypads, data lines, buttons Notebook computers Digital Cameras Portable GPS MP3 players Typical Application Pin Configuration Signal Line 1 2 Bidirection Protection of Single Line Rev. 2.2 July 2015 www.aosmd.com Page 1 of 7 AOZ8252 Ordering Information Part Number Ambient Temperature Range Package Environmental AOZ8252DI-05 -40 °C to +85 °C DFN 0.62 x 0.32 Green Product AOS Green Products use reduced levels of Halogens, and are also RoHS compliant. Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information. Absolute Maximum Ratings Exceeding the Absolute Maximum Ratings may damage the device. Parameter Rating VP – VN 5V Peak Pulse Current (IPP), tP = 8/20µs 2A Peak Pulse Power, tP = 8/20µs 30 W Storage Temperature (TS) -65 °C to +150 °C ESD Rating per IEC61000-4-2, Contact ±25 kV Air(1) ±30 kV Model(2) ±25 kV ESD Rating per IEC61000-4-2, ESD Rating per Human Body (1) Notes: 1. IEC 61000-4-2 discharge with CDischarge = 150 pF, RDischarge = 330 Ω. 2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100 pF, RDischarge = 1.5 kΩ. Maximum Operating Conditions The device is not guaranteed to operate beyond the Maximum Operating Conditions. Parameter Rating Junction Temperature (TJ) Rev. 2.2 July 2015 -40 °C to +125 °C www.aosmd.com Page 2 of 7 AOZ8252 Electrical Characteristics TA = 25°C unless otherwise specified. Symbol Parameter Diagram IPP Maximum Reverse Peak Pulse Current VCL Clamping Voltage @ IPP (IEC61000-4-5 8/20 µs peak current) VRWM Working Peak Reverse Voltage IR Maximum Reverse Leakage Current VBR Breakdown Voltage IF Forward Current VF Forward Voltage PPK Peak Power Dissipation CJ Capacitance @ VR = 0 and f = 1 MHz IPP VCL VBR VRWM IR IT VRWM VBR VCL V IPP VBR (V) Device Device Marking VRWM (V) Max. Min. AOZ8252DI-05 D 5.0 6.0 Rev. 2.2 July 2015 I Max. IR (µA) Max. VF (V) Typ. VCL Max. IPP = 2 A CJ (pF) Typ. 11.0 0.1 1.0 15.0 0.3 www.aosmd.com Page 3 of 7 AOZ8252 Typical Performance Characteristics Clamping Voltage vs. Peak Pulse Current (tperiod = 100ns, tr = 1ns) Insertion Loss (S21) vs. Frequency 5 0 Insertion Loss (dB) Clamping Voltage, VCL (V) 30 25 20 15 -5 -10 -15 -20 -25 10 0 2 4 6 8 10 1 12 10 100 1000 10000 Frequency (MHz) Peak Pulse Current, IPP (A) Typical Variation of CIN vs. VR Normalized Input Capacitance (f = 1MHz, T = 25C) 1.20 1.00 0.80 0.60 0.40 0.20 0 0 1 2 3 4 5 Input Voltage (V) Rev. 2.2 July 2015 www.aosmd.com Page 4 of 7 AOZ8252 Package Dimensions, DFN 0.62x0.32, 2L D D1 D2 D1 E1 E TOP VIEW D3 BOTTTOM VIEW A SIDE VIEW Dimensions in millimeters RECOMMENDED LAND PATTERN 0.195 0.210 0.320 Symbols A Min. 0.27 D D1 0.57 0.11 0.145 0.305 0.27 0.17 D2 D3 E E1 Nom. Max. 0.30 0.62 0.16 0.195 0.355 0.32 0.22 0.33 0.67 0.21 0.245 0.405 0.37 0.27 Dimensions in inches Symbols Min. Nom. Max. A 0.0106 0.0118 0.0130 D 0.0224 0.0244 0.0264 D1 0.0043 0.0063 0.0083 0.0057 0.0077 0.0097 D2 0.0120 0.0140 0.0167 D3 0.0106 0.0126 0.0146 E 0.0067 0.0087 0.0107 E1 0.405 0.615 Unit: mm Notes: 1. All dimensions are in millimeters. 2. Dimensions are inclusive of plating. 3. Package body sizes exclude mold flash and gate burrs. Mold flash at the non-lead sides should be less than 6mil each. 4. Controlling dimension is millimeter. Converted inch dimensions are not necessarily exact. 5. Paddle exposed on bottom. Rev. 2.2 July 2015 www.aosmd.com Page 5 of 7 AOZ8252 Tape and Reel Dimensions, DFN 0.62x0.32 P1 Carrier Tape D1 P2 T E1 E2 E B0 D0 K0 P0 A0 Feeding Direction UNIT: MM A0 Package B0 K0 D0 D1 E E1 E2 P0 P1 P2 T 0.45 0.74 0.34 0.20 1.50 8.00 1.75 3.50 2.00 4.00 2.00 0.20 DFN 0.62x0.32 +0.02/-0.03 ±0.03 +0.03/-0.01 ±0.05 +0.1/-0.0 ±0.10 ±0.10 ±0.05 ±0.05 ±0.05 ±0.05 ±0.05 (8mm) W1 Reel S G K N M V H R W UNIT: MM Tape Size Reel Size M N W W1 H K S G R V 8 mm ø178 ø178.0 ø55.0 MAX. 2.0 N/A N/A N/A ±1.0 MAX. 14.4 ø13.0 ±0.5 8.4 +1.5/-0 ±0.5 10.1 ±0.5 Leader/Trailer and Orientation Trailer Tape 300mm min. Components Tape Orientation in Pocket Leader Tape 500mm min. Detail: Unit Direction in Pocket Rev. 2.2 July 2015 www.aosmd.com Page 6 of 7 AOZ8252 Part Marking AOZ8252DI-05 (DFN0.62x0.32) Date Code (1st to 15th) Pin 2 Date Code (16th to end of month) Pin 2 Year Code Pin 1 D Year Code Month Code Pin 1 Product Number Code D Month Code Product Number Code LEGAL DISCLAIMER Alpha and Omega Semiconductor makes no representations or warranties with respect to the accuracy or completeness of the information provided herein and takes no liabilities for the consequences of use of such information or any product described herein. Alpha and Omega Semiconductor reserves the right to make changes to such information at any time without further notice. This document does not constitute the grant of any intellectual property rights or representation of non-infringement of any third party’s intellectual property rights. LIFE SUPPORT POLICY ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. Rev. 2.2 July 2015 2. A critical component in any component of a life support, device, or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.aosmd.com Page 7 of 7