AOZ8212ACI-05 Two-line Bi-directional TVS Diode General Description Features The AOZ8212ACI-05 is a two-line bi-directional transient voltage suppressor diode designed to protect voltage sensitive electronics from high transient conditions and ESD. This device incorporates two TVS diodes in a small SOT-23 package. It may be used to meet the ESD immunity requirements of IEC 61000-4-2, Level 4 (±15kV air, ±15kV contact discharge). The AOZ8212ACI-05 comes in a SOT-23 package and is rated over a -40°C to +85°C ambient temperature range. The small SOT-23 package makes it ideal for applications where PCB space is a premium. The small size and high ESD protection makes it ideal for protecting voltage sensitive electronics from high transient conditions and ESD. Typical Application ESD protection for high-speed data lines: – Exceeds: IEC 61000-4-2 (ESD) ±15kV (air), ±15kV (contact) – Human Body Model (HBM) ±30kV – IEC 61000-4-5 (Lightning) 6A (8/20µs) IEC 61000-4-4 (EFT) ±40A Low clamping voltage Low operating voltages: 5.0V Applications Portable handheld devices Keypads, data lines, buttons Notebook computers Digital Cameras Portable GPS MP3 players Pin Configuration I/O1 1 I/O2 1 2 3 2 SOT-23 3 (Top View) Bidirection Protection of Two Lines Rev. 1.0 December 2014 www.aosmd.com Page 1 of 6 AOZ8212ACI-05 Ordering Information Part Number Ambient Temperature Range Package Environmental AOZ8212ACI-05 -40°C to +85°C SOT-23 Green Product AOS Green Products use reduced levels of Halogens, and are also RoHS compliant. Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information. Absolute Maximum Ratings Exceeding the Absolute Maximum ratings may damage the device. Parameter Rating Peak Pulse Current (IPP), tP = 8/20µs 6A Peak Power Dissipation (TBD @ 25°C) 110W Storage Temperature (TS) -65°C to +150°C IEC 61000-4-4 (EFT) ±40A ESD Rating per IEC61000-4-2, Contact (1) ±15kV ESD Rating per IEC61000-4-2, Air(1) ESD Rating per Human Body ±15kV Model(2) ±30kV Notes: 1. IEC 61000-4-2 discharge with CDischarge = 150pF, RDischarge = 330Ω. 2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100pF, RDischarge = 1.5kΩ. Maximum Operating Ratings Parameter Rating Junction Temperature (TJ) -40°C to +125°C Electrical Characteristics TA = 25°C unless otherwise specified. Symbol Parameter Symbol Parameter IPP Maximum Reverse Peak Pulse Current IF Forward Current VCL Clamping Voltage @ IPP VF Forward Voltage Working Peak Reverse Voltage Ppk Peak Power Dissipation Maximum Reverse Leakage Current CJ Max. Capacitance @ VR = 0 and f = 1MHz VRWM IR VBR Breakdown Voltage Electrical Characteristics TA = 25°C unless otherwise noted. VCL Max. Device Device Marking VRWM (V) Max. VBR (V) Min @ 1mA IR (µA) Max. IPP = 1A IPP = 10A CJ (pF) Typ. CJ (pF) Max. AOZ8212ACI-05 BX 5.0 5.5 0.1 10.0 16.0 11.0 14.0 Rev. 1.0 December 2014 www.aosmd.com Page 2 of 6 AOZ8212ACI-05 Typical Performance Characteristics Typical Variation of CIN vs. VR TLP Current vs. Clamping Voltage 30 14 25 12 Input Capacitance (pF) TLP Current (A) (tperiod = 100ns, tr = 1ns) 20 15 10 5 10 8 6 4 2 0 0 0 5 10 15 20 25 Clamping Voltage (V) Rev. 1.0 December 2014 www.aosmd.com 0 1 2 3 Input Voltage (V) 4 5 Page 3 of 6 AOZ8212ACI-05 Gauge Plane Seating Plane Package Dimensions, SOT-23 3L D 0.25mm e C L E E1 θ1 e1 A2 A 0.10mm b RECOMMENDED LAND PATTERN 2.40 0.80 0.80 0.95 UNIT: mm A1 Dimensions in millimeters Symbols A A1 A2 b c D E E1 e e1 L θ1 Min. 0.85 0.00 0.70 0.30 0.08 2.80 2.60 1.40 Nom. — — 1.00 0.40 0.13 2.90 2.80 1.60 0.95 BSC 1.90 BSC 0.30 — 0° 5° Max. 1.25 0.13 1.15 0.50 0.20 3.10 3.00 1.80 0.60 8° Dimensions in inches Symbols A A1 A2 b c D E E1 e e1 L θ1 Min. 0.033 0.000 0.028 0.012 0.003 0.110 0.102 0.055 Nom. Max. — 0.049 — 0.005 0.039 0.045 0.016 0.020 0.005 0.008 0.114 0.122 0.110 0.118 0.063 0.071 0.037 BSC 0.075 BSC 0.012 — 0.024 0° 5° 8° Notes: 1. Package body sizes exclude mold flash or gate burrs. Mold flash at the non-lead sides should be less than 5mils each. 2. Tolerance ±0.100mm (4mils) unless otherwise specified. 3. Dimension L is measured in gauge plane. 4. Controlling dimension is millimeter, converted inch dimensions are not necessarily exact. 5. All dimensions are in millimeters. Rev. 1.0 December 2014 www.aosmd.com Page 4 of 6 AOZ8212ACI-05 Tape and Reel Dimensions, SOT-23 3L Tape P1 D1 SEE NOTE 3 P2 T SEE NOTE 5 E2 SEE NOTE 5 E1 E B0 K0 D0 A0 P0 Feeding Direction Unit: mm Package A0 B0 K0 D0 D1 E E1 E2 P0 P1 P2 T SOT23 (8mm) 3.15 ±0.10 3.20 ±0.10 1.40 ±0.10 1.50 MIN. 1.50 ±0.10 8.00 ±0.30 1.75 ±0.10 3.50 ±0.05 4.00 ±0.10 4.00 ±0.10 2.00 ±0.05 0.15 ~ 0.30 W1 Reel S G K N M V H R W Unit: mm Tape Size Reel Size M N W W1 H K S G R V 8mm ø180 ø180.00 ±0.50 ø60.50 9.00 ±0.30 11.00 ±1.00 13.00 +0.50 / -0.20 10.60 2.00 ±0.50 ø9.00 5.00 18.00 Leader/Trailer and Orientation Unit Per Reel: 3000pcs Trailer Tape 300mm Min. OR 75 Empty Pockets Rev. 1.0 December 2014 Components Tape Orientation In Pocket www.aosmd.com Leader Tape 500mm Min. OR 125 Empty Pockets Page 5 of 6 AOZ8212ACI-05 BX0A Part Number Code Underscore Denotes Green Product 11 Package Marking Assembly Lot Code Option Code Week Code LEGAL DISCLAIMER Alpha and Omega Semiconductor makes no representations or warranties with respect to the accuracy or completeness of the information provided herein and takes no liabilities for the consequences of use of such information or any product described herein. Alpha and Omega Semiconductor reserves the right to make changes to such information at any time without further notice. This document does not constitute the grant of any intellectual property rights or representation of non-infringement of any third party’s intellectual property rights. LIFE SUPPORT POLICY ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. Rev. 1.0 December 2014 2. A critical component in any component of a life support, device, or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.aosmd.com Page 6 of 6