AK 06

SANKEN ELECTRIC CO., LTD.
AK06
1. Scope
The present specifications shall apply to an AK06.
2. Outline
Type
Silicon Schottky Barrier Diode
Structure
Resin Molded
Applications
High Frequency Rectification
3. Flammability
UL94V-0(Equivalent)
040908
1/5
61426-01
SANKEN ELECTRIC CO., LTD.
AK06
4. Absolute maximum ratings
No.
Item
Symbol
Unit
Rating
1
Transient Peak Reverse Voltage
VRSM
V
60
2
Peak Reverse Voltage
VRM
V
60
3
Average Forward Current
IF(AV)
A
0.7
4
Peak Surge Forward Current
IFSM
A
10
5
I2t Limiting Value
I2t
A2s
0.5
6
Junction Temperature
Tj
°C
-40~+150
7
Storage Temperature
Tstg
°C
-40~+150
Conditions
Refer to Derating of 7
10msec.
Half sinewave, one shot
1msec≤t≤10msec
5. Electrical characteristics (Ta=25°C ,unless otherwise specified)
No.
1
Item
Reverse Leakage Current
3
Reverse Leakage Current Under
High Temperature
040908
Unit
Value
Conditions
VF1
V
0.58 max
IF=0.6A
VF2
V
0.62 max.
IF=0.7A
IR
mA
1.0 max.
VR=VRM
H・IR1
mA
7.5 max
VR=VRM, Tj=125°C
H・IR2
mA
30 max.
VR=VRM, Tj=150°C
Rth(j-l)
°C /W
22 max.
Between Junction and Lead
Forward Voltage Drop
2
4
Symbol
Thermal Resistance
2/5
61426-01
SANKEN ELECTRIC CO., LTD.
AK06
6. Characteristics
IF(AV) - PF
0.7
Tj=150°C
0.6
t
PF (W)
Forward Power Dissipation (W)
T
0.5
t/T=1/6
0.4
t/T=1/3,sinewave
0.3
t/T=1/2
0.2
DC
0.1
0
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
IF(AV) (A)
Average Forward Current (A)
VR - P R
2.0
Tj=150°C
PR (W)
Reverse Power Dissipation (W)
t
T
1.5
1-t/T=5/6
1.0
1-t/T=2/3
1-t/T=1/2
0.5
sinewave
0.0
0
10
20
30
40
50
60
VR (V)
Reverse Voltage (V)
040908
3/5
61426-01
SANKEN ELECTRIC CO., LTD.
AK06
7. Derating
Tl - IF(AV)
VR=0(V)
0.7
t/T=1/6
IF(AV) (A)
Average Forward Current (A)
0.6
t/T=1/3
0.5
t/T=1/2
0.4
0.3
sinewave
0.2
Tj=150°C
DC
0.1
t
T
0
100
110
120
130
140
150
Tl (°C)
Lead Temperature (°C)
Tl - IF(AV)
VR=60(V)
0.7
0.6
IF(AV) (A)
Average Forward Current (A)
t/T=1/6
0.5
t/T=1/3
0.4
t/T=1/2
0.3
0.2
0.1
0
100
sinewave
Tj=150°C
DC
t
T
110
120
130
140
150
Tl (°C)
Lead Temperature (°C)
040908
4/5
61426-01
SANKEN ELECTRIC CO., LTD.
AK06
8. Package information
8-1 Dimensions
Marking
Dimensions in mm
*1 The allowance position of Body against the center of whole lead wire is 0.5mm(max.)
*2 The centric allowance of lead wire against center of physical body is 0.2mm(max.)
*3 The burr may exit up to 2mm from the body of lead
*4 Whole lead wire is 62.0±1.0, with 52mm taping.
8-2 Appearance
The body shall be clean and shall not bear any stain, rust or flaw.
8-3 Marking
① Type number AK06 is abbreviated as K6
② Lot number 1
Last digit of Year
ƒƒ
J
\ƒ
[ƒ
hƒ
\ƒ
¦
Cathode Band
040908
ƒ
B
@
ƒ
ƒ
A
③ Lot number 2
Month
From 1 to 9 for Jan. to Sep.
O for Oct., N for Nov., and D for Dec.
5/5
61426-01