Schottky Barrier Diode MPEN-230AF December. 2005 ■General Description ■Package---TO-262 High Voltage Schottky Barrier Diode (100V). The low leakage current and low VF have been achieved by using the optimum barrier metal. ■Applications • DC-DC converters • AC adapter • High frequency rectification circuit, etc. ■Key Specifications ■Features • High Voltage 100Vguarantee • Steady operation is possible even at high temperature with a low leakage current. • Ultrafast & low noise switching. Item • Low forward voltage drop. Unit Rating VRM V 100 VF V 0.90 IF(AV) A 30 Conditions IF=15A Typical Characteristics IF-VF Characteristics VR-IR Characteristics 1.0E+02 1.0E-01 Tj=150℃ 1.0E-02 1.0E+01 Tj=125℃ 1.0E-03 Tj=100℃ IR (A) IF (A) 1.0E+00 Tj=150℃ 1.0E-04 1.0E-01 Tj=125℃ 1.0E-05 Tj=100℃ Tj=25℃ 1.0E-02 1.0E-06 Tj=25℃ 1.0E-03 1.0E-07 0 0.5 1 1.5 0 VF (V) 20 40 60 80 100 VR (V) . Sanken Electric Co.,Ltd. http://www.sanken-ele.co.jp/en/ 1/7 D01-006EA-051202 Schottky Barrier Diode MPEN-230AF December. 2005 Absolute maximum ratings No. Item Symbol Unit Rating 1 Transient Peak Reverse Voltage VRSM V 100 2 Peak Reverse Voltage VRM V 100 3 Average Forward Current IF(AV) A 30 4 Peak Surge Forward Current IFSM A 150 5 I2t Limiting Value I2t A2s 112.5 6 Junction Temperature Tj °C -40 to +150 7 Storage Temperature Tstg °C -40 to +150 Conditions Half sinewave, one shot 1msec ≤ t ≤ 10msec No.1, 2, 4 & 5 show ratings per one chip. Electrical characteristics (Ta=25°C, unless otherwise specified) No. Item Symbol Unit Value Conditions 1 Forward Voltage Drop VF V 0.90 max. IF=15A 2 Reverse Leakage Current IR uA 250 max. VR=VRM H•IR mA 125 max. VR=VRM, Tj=150°C Rth(j-c) °C/W 1.5 max. 3 4 Reverse Leakage Current Under High Temperature Thermal Resistance Between Junction and case No.1, 2, & 3 show characteristics per one chip. Sanken Electric Co.,Ltd. D01-006EA-051202 2/7 Schottky Barrier Diode MPEN-230AF December. 2005 Characteristics Forward Power Dissipation PF (W) Forward Power Dissipation Average Forward Current IF(AV) (A) Reverse Power Dissipation PR (W) Reverse Power Dissipation Reverse Voltage VR (V) Average Forward Current IF(AV) (A) Current Derating Case temperature Tc (°C) Sanken Electric Co.,Ltd. D01-006EA-051202 3/7 Schottky Barrier Diode MPEN-230AF December. 2005 Outline drawings, mm 1 2 3 Connection Diagram 1 2 3 Sanken Electric Co.,Ltd. D01-006EA-051202 4/7 Schottky Barrier Diode MPEN-230AF December. 2005 <Worldwide Contacts> Asia Pacific China Sanken Electric Hong Kong Co., Ltd. Suite 1026 Ocean Centre, Canton Road, Tsimshatsui, Kowloon, Hong Kong Tel: 852-2735-5262 Fax: 852-2735-5494 Sanken Electric (Shanghai) Co., Ltd. Room3202, Maxdo Centre, Xingyi Road 8, Changning district, Shanghai, China Tel: 86-21-5208-1177 Fax: 86-21-5208-1757 Taiwan Sanken Electric Co., Ltd. Room 1801, 18th Floor, 88 Jung Shiau East Road, Sec. 2, Taipei 100, Taiwan R.O.C. Tel: 886-2-2356-8161 Fax: 886-2-2356-8261 India Saket Devices Pvt. Ltd. Office No.13, First Floor, Bandal - Dhankude Plaza, Near PMT Depot, Paud Road, Kothrud, Pune - 411 038, India Tel: 91-20-5621-2340 91-20-2528-5449 Fax: 91-20-2528-5459 Japan Sanken Electric Co., Ltd. Overseas Sales Headquaters Metropolitan Plaza Bldg. 1-11-1 Nishi-Ikebukuro, Toshima-ku, Tokyo 171-0021, Japan Tel: 81-3-3986-6164 Fax: 81-3-3986-8637 Korea Sanken Electric Korea Co., Ltd. Mirae Asset Life Bldg. 6F, 168 Kongduk-dong, Mapo-ku, Seoul, 121-705, Korea Tel: 82-2-714-3700 Fax: 82-2-3272-2145 Singapore Sanken Electric Singapore Pte. Ltd. 150 Beach Road, #14-03 The Gateway West, Singapore 189720 Tel: 65-6291-4755 Fax: 65-6297-1744 Sanken Electric Co.,Ltd. D01-006EA-051202 5/7 Schottky Barrier Diode MPEN-230AF December. 2005 Europe United Kingdom Sanken Power Systems (UK) Limited Pencoed Technology Park, Pencoed, Bridgend CF35 5HY. UK Tel: 44-1656-869-100 Fax: 44-1656-869-162 North America United States Allegro MicroSystems, Inc. 115 Northeast Cutoff, Worcester, Massachusetts 01606, U.S.A. Tel: 1-508-853-5000 Fax: 1-508-853-3353 Allegro MicroSystems, Inc. (Southern California) 14 Hughes Street, Suite B105, Irvine, CA 92618 Tel: 1-949-460-2003 Fax: 1-949-460-7837 Sanken Electric Co.,Ltd. D01-006EA-051202 6/7 Schottky Barrier Diode MPEN-230AF December. 2005 CAUTION / WARNING ●The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. ● Sanken reserves the right to make changes without further notice to any products herein in the interest of improvements in the performance, reliability, or manufacturability of its products. Before placing an order, Sanken advises its customers to obtain the latest version of the relevant information to verify that the information being relied upon is current. ● Application and operation examples described in this catalog are quoted for the sole purpose of reference for the use of the products herein and Sanken can assume no responsibility for any infringement of industrial property rights, intellectual property rights or any other rights of Sanken or any third party which may result from its use. ● When using the products herein, the applicability and suitability of such products for the intended purpose or object shall be reviewed at the users’ responsibility. ● Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure nd defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own risk, preventative measures including safety design of the equipment or systems against any possible injury, death, fires or damages to the society due to device failure or malfunction. ● Sanken products listed in this catalog are designed and intended for the use as components in general purpose electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Before placing an order, the user’s written consent to the specifications is requested. When considering the use of Sanken products in the applications where higher reliability is required (transportation equipment and its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various safety devices, etc.), please contact your nearest Sanken sales representative to discuss and obtain written confirmation of your specifications. The use of Sanken products without the written consent of Sanken in the applications where extremely high reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly prohibited. ● Anti radioactive ray design is not considered for the products listed herein. ● This publication shall not be reproduced in whole or in part without prior written approval from Sanken. ●This is notification that you, as purchaser of the products/technology, are not allowed to perform any of the following: 1. Resell or retransfer these products/technology to any party intending to disturb international peace and security. 2. Use these products/technology yourself for activities disturbing international peace and security. 3. Allow any other party to use these products/technology for activities disturbing international peace and security. Also, as purchaser of these products/technology, you agree to follow the procedures for the export or transfer of these products/technology, under the Foreign Exchange and Foreign Trade Law, when you export or transfer the products/technology abroad. Sanken Electric Co.,Ltd. D01-006EA-051202 7/7