MPL-1036S

Ultrafast Recovery Diode
MPL-1036S
General Description
January, 2006
Package --- TO-263
A surface mount device added to 600V_L series.
Realizes better space-saving in mounting on a printed circuit
board by using a surface mount package (TO-263).
Applications
● Continuous-current-mode PFC circuit.
● An output rectifier for SMPS, UPS, or DC-DC converters.
● A Flywheel diode for inverters and choppers.
Features
● Surface mount package (TO-263)
● Low loss FRD (600 V_L series)
Key Specifications
Absolute maximum ratings
Die Structure: Silicon Planer Diode (FRD)
Parameter
Symbol
Unit
Rating
Transient Peak Reverse Voltage
VRSM
V
600
Peak Reverse Voltage
VRM
V
600
Average Forward Current
IF(AV)
A
3
Peak Surge Forward Current
IFSM
A
50
Electrical characteristics
Parameter
Symbol Unit
Rating
Forward Voltage Drop
VF
V
Reverse Leakage Current
IR
μA
50 max.
Reverse Leakage Current
Under High Temperature
H•IR
μA
100 max.
Reverse Recovery Time
trr
ns
50 max.
Conditions
1.75 max. IF=3A
VR=VRM
VR=VRM,
Tj=150°C
IF=IRP=100mA
90%Recovery point
Sanken Electric Co.,Ltd.
1/5
D01-007JE-060113
Ultrafast Recovery Diode
MPL-1036S
January, 2006
§1. Absolute Maximum Ratings and Electrical Characteristics
•Absolute Maximum Ratings
No.
Parameter
1
Symbol
Unit
Rating
Transient Peak Reverse Voltage
VRSM
V
600
2
Peak Reverse Voltage
VRM
V
600
3
Average Forward Current
IF(AV)
A
3
4
Peak Surge Forward Current
IFSM
A
50
2
5
I2t Limiting Value
It
A2S
12.5
6
Junction Temperature
Tj
°C
-40 to +150
7
Storage Temperature
Tstg
°C
-40 to+150
Symbol
Unit
Rating
Conditions
10msec. Half sine-wave, one shot
1msec ≤ t ≤ 10msec
• Electrical Characteristics
No.
Parameter
Conditions
1
Forward Voltage Drop
VF
V
1.75 max.
2
Reverse Leakage Current
IR
µA
50 max.
VR=VRM
H•IR
µA
100 max.
VR=VRM, Tj=150°C
trr
ns
50 max
IF=IRP=100mA
90% Recovery point
Rth(j-c)
°C/W
2.5 max.
Between Junction and case
3
Reverse Leakage Current Under
High Temperature
4
Reverse Recovery Time
5
Thermal Resistance
IF=3A
Sanken Electric Co.,Ltd.
2/5
D01-007JE-060113
Ultrafast Recovery Diode
MPL-1036S
January, 2006
§2. Package information
2-1 Package type, physical dimensions
(3)
(2)
(1)
(2) is connected to a heat sink.
Unit: ㎜
2-2 Marking
Marking
Part Number
Type Name
Polarity
Lot number
1st letter: Last digit of year
MPL-1036S
2nd letter: Month From 1 to 9 for Jan. to Sep.,
O for Oct., N for Nov., D for Dec.
L1036
3rd letter: Day Week(Every month of 1st to 5th week)
4th to 6th letter:
Suffix No.
Sanken Electric Co.,Ltd.
3/5
D01-007JE-060113
Ultrafast Recovery Diode
MPL-1036S
January, 2006
§3. Characteristics
IF(AV) - PF
Forward Power Dissipation PF (W)
10
Tj=150°C
8
t
T
t/T=1/6
6
t/T=1/3,Sine-wave
4
t/T=1/2
DC
2
0
0
1
2
Average Forward Current IF(AV) (A)
Tc - IF(AV)
§4. Derating
3
VR=0 (V)
3
Average Forward Current
IF(AV) (A)
DC
t/T=1/3, Sine-wave
t/T=1/2
2
t/T=1/6
1
Tj=150°C
t
T
0
0
50
100
Case Temperature Tc (°C)
150
Sanken Electric Co.,Ltd.
4/5
D01-007JE-060113
Ultrafast Recovery Diode
MPL-1036S
January, 2006
CAUTION / WARNING
●The information in this publication has been carefully checked and is believed to be accurate; however, no
responsibility is assumed for inaccuracies.
● Sanken reserves the right to make changes without further notice to any products herein in the interest of
improvements in the performance, reliability, or manufacturability of its products.
Before placing an order, Sanken advises its customers to obtain the latest version of the relevant information to verify
that the information being relied upon is current.
● Application and operation examples described in this catalog are quoted for the sole purpose of reference for the use
of the products herein and Sanken can assume no responsibility for any infringement of industrial property rights,
intellectual property rights or any other rights of Sanken or any third party which may result from its use.
● When using the products herein, the applicability and suitability of such products for the intended purpose or object
shall be reviewed at the users’ responsibility.
● Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure nd defect
of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own
risk, preventative measures including safety design of the equipment or systems against any possible injury, death,
fires or damages to the society due to device failure or malfunction.
● Sanken products listed in this catalog are designed and intended for the use as components in general purpose
electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring
equipment, etc.). Before placing an order, the user’s written consent to the specifications is requested.
When considering the use of Sanken products in the applications where higher reliability is required (transportation
equipment and its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various
safety devices, etc.), please contact your nearest Sanken sales representative to discuss and obtain written confirmation
of your specifications. The use of Sanken products without the written consent of Sanken in the applications where
extremely high reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.)
is strictly prohibited.
● Anti radioactive ray design is not considered for the products listed herein.
● This publication shall not be reproduced in whole or in part without prior written approval from Sanken.
●This is notification that you, as purchaser of the products/technology, are not allowed to perform any of the following:
1. Resell or retransfer these products/technology to any party intending to disturb international peace and security.
2. Use these products/technology yourself for activities disturbing international peace and security.
3. Allow any other party to use these products/technology for activities disturbing international peace and security.
Also, as purchaser of these products/technology, you agree to follow the procedures for the export or transfer of these
products/technology, under the Foreign Exchange and Foreign Trade Law, when you export or transfer the
products/technology abroad.
Sanken Electric Co.,Ltd.
5/5
D01-007JE-060113