Cable transducer Analog output Measuring length absolute up to 4.7 m GCA5 - analog Features –– Analog interface 0.5...4.5 V –– Measuring length 4.7 m –– Space saving design –– Designed for harsh environmental conditions –– Removable stickers for drainage Technical data - mechanical design Voltage supply Protection DIN EN 60529 IP 67 (housing, drainage holes closed), IP 54 (cable inlet) Materials Cable: Stainless steel cable sheathed with nylon Housing: plastic Operating temperature -40...+85 °C Measuring length 4.7 m Cable acceleration ≤50 m/s² Cable diameter 0.9 mm Pull-in force >1.5 N (pull-in force reduced at low temperatures) Pull-out force ≤8 N Relative humidity 95 % temporary condensing Resistance DIN EN 60068-2-6 Vibration 10 g, 10-2000 Hz DIN EN 60068-2-27 Shock 50 g, 11 ms Weight approx. 900 g Connection Flange connector M12, 5-pin Cable 2 m Instruction Please consider the assembly instructions 8...30 VDC Reverse polarity protection Yes Short-circuit proof Yes Consumption w/o load ≤35 mA (24 VDC) Initializing time ≤500 ms after power on Interface Analog (0.5...4.5 V) Function Linear position feedback Resolution 12 bit Linearity ±1 % full scale output (f.s.o.) Absolute accuracy ±1.8 % f.s.o. (+25 °C) ±2 % f.s.o. (-40...+85 °C) Sensing method Magnetic Interference immunity DIN EN 61000-6-2 Emitted interference DIN EN 61000-6-4 Factory setting Entire measuring range Min. output at 0 m Max. output at 4.7 m 1 www.baumer.com/motion 13/6/2016 Technical data - electrical ratings Subject to modification in technic and design. Errors and omissions excepted. GCA5 analog Cable transducer Analog output Measuring length absolute up to 4.7 m GCA5 - analog Part number GCA5-PM047.RA .V30.A Connection L Cable radial, 2 m N Flange connector M12, 5-pin, radial, male contacts, ccw Accessories Mounting accessories Subject to modification in technic and design. Errors and omissions excepted. Idler pulley for cable thickness 0.8...1 mm 2 www.baumer.com/motion 13/6/2016 Z 119.065 Cable transducer Analog output Measuring length absolute up to 4.7 m GCA5 - analog Terminal significance Terminal assignment +Vs Cable transducer supply voltage. Flange connector M12 and cable 0V Cable transducer ground connection relating to +Vs. Connector Core colour Assignment Voltage output. Current output: max. 10 mA Load resistor: ≥1 kΩ between Uout / 0 V Pin 1 blue 0V Pin 2 brown +Vs Pin 3 black Uout Pin 4 – n.c. Pin 5 – n.c. Cable data: 3 x 0.5 mm2, 2 m 3 4 5 2 Subject to modification in technic and design. Errors and omissions excepted. 1 3 www.baumer.com/motion 13/6/2016 Uout Cable transducer Analog output Measuring length absolute up to 4.7 m GCA5 - analog Dimensions GCA5 with cable 65 39 26 26.4 .5 ø9 78 ø4 .2 36.3 ø5 104 31 12 (2x ) 33.3 78 4 www.baumer.com/motion 13/6/2016 Subject to modification in technic and design. Errors and omissions excepted. ø3 Cable transducer Analog output Measuring length absolute up to 4.7 m GCA5 - analog Dimensions GCA5 with flange connector M12 65 39 26 26.5 .5 ø9 78 ø4 .2 36.3 ø5 104 31 12 ) 33.3 78 5 www.baumer.com/motion 13/6/2016 M12 x1 (2x Subject to modification in technic and design. Errors and omissions excepted. ø3