EN

Cable transducer
Analog output
Measuring length absolute up to 4.7 m
GCA5 - analog
Features
–– Analog interface 0.5...4.5 V
–– Measuring length 4.7 m
–– Space saving design
–– Designed for harsh environmental conditions
–– Removable stickers for drainage
Technical data - mechanical design
Voltage supply
Protection DIN EN 60529
IP 67 (housing, drainage holes
closed), IP 54 (cable inlet)
Materials
Cable: Stainless steel cable
sheathed with nylon
Housing: plastic
Operating temperature
-40...+85 °C
Measuring length
4.7 m
Cable acceleration
≤50 m/s²
Cable diameter
0.9 mm
Pull-in force
>1.5 N (pull-in force reduced at
low temperatures)
Pull-out force
≤8 N
Relative humidity
95 % temporary condensing
Resistance
DIN EN 60068-2-6
Vibration 10 g, 10-2000 Hz
DIN EN 60068-2-27
Shock 50 g, 11 ms
Weight approx.
900 g
Connection
Flange connector M12, 5-pin
Cable 2 m
Instruction
Please consider the assembly
instructions
8...30 VDC
Reverse polarity protection Yes
Short-circuit proof
Yes
Consumption w/o load
≤35 mA (24 VDC)
Initializing time
≤500 ms after power on
Interface
Analog (0.5...4.5 V)
Function
Linear position feedback
Resolution
12 bit
Linearity
±1 % full scale output (f.s.o.)
Absolute accuracy
±1.8 % f.s.o. (+25 °C)
±2 % f.s.o. (-40...+85 °C)
Sensing method
Magnetic
Interference immunity
DIN EN 61000-6-2
Emitted interference
DIN EN 61000-6-4
Factory setting
Entire measuring range
Min. output at 0 m
Max. output at 4.7 m
1
www.baumer.com/motion
13/6/2016
Technical data - electrical ratings
Subject to modification in technic and design. Errors and omissions excepted.
GCA5 analog
Cable transducer
Analog output
Measuring length absolute up to 4.7 m
GCA5 - analog
Part number
GCA5-PM047.RA
.V30.A
Connection
L Cable radial, 2 m
N Flange connector M12, 5-pin, radial, male contacts, ccw
Accessories
Mounting accessories
Subject to modification in technic and design. Errors and omissions excepted.
Idler pulley for cable thickness 0.8...1 mm
2
www.baumer.com/motion
13/6/2016
Z 119.065
Cable transducer
Analog output
Measuring length absolute up to 4.7 m
GCA5 - analog
Terminal significance
Terminal assignment
+Vs
Cable transducer supply voltage.
Flange connector M12 and cable
0V
Cable transducer ground connection
relating to +Vs.
Connector
Core colour
Assignment
Voltage output.
Current output: max. 10 mA
Load resistor: ≥1 kΩ between Uout / 0 V
Pin 1
blue
0V
Pin 2
brown
+Vs
Pin 3
black
Uout
Pin 4
–
n.c.
Pin 5
–
n.c.
Cable data: 3 x 0.5 mm2, 2 m
3
4
5
2
Subject to modification in technic and design. Errors and omissions excepted.
1
3
www.baumer.com/motion
13/6/2016
Uout
Cable transducer
Analog output
Measuring length absolute up to 4.7 m
GCA5 - analog
Dimensions
GCA5 with cable
65
39
26
26.4
.5
ø9
78
ø4
.2
36.3
ø5
104
31
12
(2x
)
33.3
78
4
www.baumer.com/motion
13/6/2016
Subject to modification in technic and design. Errors and omissions excepted.
ø3
Cable transducer
Analog output
Measuring length absolute up to 4.7 m
GCA5 - analog
Dimensions
GCA5 with flange connector M12
65
39
26
26.5
.5
ø9
78
ø4
.2
36.3
ø5
104
31
12
)
33.3
78
5
www.baumer.com/motion
13/6/2016
M12 x1
(2x
Subject to modification in technic and design. Errors and omissions excepted.
ø3