Baumer VeriSens-Profinet-Gateway EN

Industrial
cameras
Network components
VeriSens
MXG02 PROFINET Gateway
®
VGA,
Industrial
Gigabit
Ethernet
Ethernet,
Gateway
Monochrome
Article number: 11135780
11094926
Features
„„Gateway with integrated PROFINET switch to connect VeriSens
via RS485 interface
„„Allows PROFINET implementation in addition to visualization or
FTP image transfer
„„Supports PROFINET line topology due to integrated switch
„„Efficient – possible implementation of up to 4 VeriSens
„„PROFINET certified (Version 2.2)
„„Requires VeriSens type VS xxxxxxxxxxxRx
(supporting RS485) with software release v2.5.0 or later
®
®
®
electrical data
10 … 33V DC (must have the same ground
potential as the VeriSens )
The product characteristics and technical data provided do not express or imply any warranty. Technical modifications and errors reserved.
voltage supply
range + Vs
dimension drawing
®
power consumption typ. 120 mA, max 150 mA
230 kBit/s
standard mounting channel
(deep DIN-rail to EN 50022)
installation position any
weight
approx. 150 g
15
5,35
environmental data
-25°C … +85°C
protection class
IP 20 (for switch cabinet use)
conformity
CE, RoHS
11
35,6
13,6
102,6
113,6
EN / 150924
operating
temperature
8
fixation
22,6
35
mechanical data
99
PROFINET I/O, RT-Class 1 (unsynchronized
real-time-communikation for the I/O-data
exchange), Conformance Class B,
integrated switch
22,1
protective functions integrated termination resistor
PROFINET
42,3
4,4
transfer rate
www.baumer.com
Data sheet VeriSens PROFINET Gateway
®
page 1/2
Network components
VeriSens PROFINET Gateway
®
Industrial Ethernet Gateway
Article number: 11135780
topology and wiring
(trigger)
(illumination)
(FTP, web-interface, etc.)
(Gateway must have the same ground potentials as the VeriSens )
on
Tx 422
on
off
Rx 422
off
1
2
3
4
5
6
7
The product characteristics and technical data provided do not express or imply any warranty. Technical modifications and errors reserved.
®
5
5
electrical connection
1
PLC
2
PROFINET gateway and switch position for activating the resistance for RS485
Pin 4, 6: RS485+
Pin 5, 7: RS485-
3
Pin assignment on the devices (max. 4)
Pin 9 (red): RS485+
Pin 12 (red/blue): RS485-
4
Branch lines (AWG26 recommended, thicker cross sections possible, twisted)
Max. length of the branch lines for all devices: < 20 m
Max. cable length at 230400 baud: 200 m (AWG26 recommended, thicker cross sections possible, twisted, shielded)
EN / 150924
5
www.baumer.com
Data sheet VeriSens PROFINET Gateway
®
page 2/2