Industrial cameras Network components VeriSens MXG02® EtherNet/IP™ Gateway VGA, Industrial Gigabit Ethernet Ethernet, Gateway Monochrome Article number: 11148124 11094926 Features Gateway with integrated EtherNet/IP™ switch to connect VeriSens® via RS485 interface Allows EtherNet/IP™ implementation in addition to visualization or FTP image transfer Supports EtherNet/IP™ line topology due to integrated switch Efficient – possible implementation of up to 4 VeriSens® Requires VeriSens® type VS xxxxxxxxxxxRx (supporting RS 485) with software release v2.6.0 or later electrical data 10 … 33V DC (must have the same ground potential as the VeriSens®) The product characteristics and technical data provided do not express or imply any warranty. Technical modifications and errors reserved. voltage supply range + Vs dimension drawing power consumption typ. 120 mA, max 150 mA 230 kBit/s 42,3 4,4 transfer rate protective functions integrated termination resistor weight 22,6 approx. 150 g 35 installation position any 99 standard mounting channel (deep DIN-rail to EN 50022) 22,1 mechanical data fixation -25°C … +85°C protection class IP 20 (for switch cabinet use) conformity CE, RoHS 15 5,35 11 35,6 13,6 102,6 113,6 EN / 150924 operating temperature 8 environmental data www.baumer.com Data sheet VeriSens® EtherNet/IP™ Gateway page 1/2 Network components VeriSens® EtherNet/IP™ Gateway Industrial Ethernet Gateway Article number: 11148124 topology and wiring (trigger) (illumination) (FTP, web-interface, etc.) on Tx 422 on off Rx 422 off 1 2 3 4 5 6 7 The product characteristics and technical data provided do not express or imply any warranty. Technical modifications and errors reserved. (Gateway must have the same ground potentials as the VeriSens®) 5 5 electrical connection 1 PLC 2 EtherNet/IP™ gateway and switch position for activating the resistance for RS485 Pin 4, 6: RS485+ Pin 5, 7: RS485- 3 Pin assignment on the devices (max. 4) Pin 9 (red): RS485+ Pin 12 (red/blue): RS485- 4 Branch lines (AWG26 recommended, thicker cross sections possible, twisted) Max. length of the branch lines for all devices: < 20 m Max. cable length at 230400 baud: 200 m (AWG26 recommended, thicker cross sections possible, twisted, shielded) EN / 150924 5 www.baumer.com Data sheet VeriSens® EtherNet/IP™ Gateway page 2/2