EN

IO-Link Device Tool V4.0
IO-Link Device Tool
User Manual
Version 4
Document name: IO-Link Device Tool - EN.doc
Release date: December 3rd 2014
December 2014
Page 1
IO-Link Device Tool V4.0
Table of Content
1. INTRODUCTION ........................................................................................................ 3
2. QUICK ACCESS ....................................................................................................... 3
2.1
WITH A USB IO-LINK MASTER ........................................................................... 3
3. SOFTWARE SETUP .................................................................................................. 4
3.1
USER ROLES ..................................................................................................... 4
3.1.1
Observer ...................................................................................................... 4
3.1.2
Maintenance ................................................................................................ 4
3.1.3
Specialist ..................................................................................................... 4
3.2
IMPORT OF THE DEVICE DESCRIPTION IODD ........................................................ 4
3.3
IO-LINK DEVICE CONTROL ................................................................................. 5
3.3.1
Tab Common ............................................................................................... 5
3.3.2
Tab Process Data ........................................................................................ 6
3.3.3
Tab Identification, Observation, Parameter, Diagnosis ................................ 6
3.3.4
Tab Generic ................................................................................................. 6
4. SYSTEM REQUIREMENTS ......................................................................................... 7
5. APPENDIX ............................................................................................................... 7
5.1
USED STANDARDS AND SPECIFICATIONS .............................................................. 7
December 2014
Page 2
IO-Link Device Tool V4.0
1. Introduction
The IO-Link device tool is used for the operation of IO-Link masters and connected IO-Link
devices. The central technological element for the operation of the connected devices is the
IO device description (IODD). Special for IO-Link is that this IO device description is mandatory.
So a worldwide accepted integration possibility is available independently from the system
environment.
The tool can be used as independent program as well as integrated in an engineering system.
Most of the features are identical so that this manual describes all variants. The specific
differences are marked accordingly.
2. Quick access
2.1 With a USB IO-Link Master
• Do not connect the USB IO-Link master.
• First install the IO-Link device tool.
• Now connect the USB IO-Link master to the PC.
• Confirm „Search Masters“ via the right mouse menu in the topology area.
• Now the USB IO-Link master is displayed.
• By double-clicking the entry, you can use it.
• Connect an IO-Link device to the USB IO-Link master. If you are not sure if the power
supply from the USB is sufficient, please use the external power supply unit.
• Press the button „Go Online“.
• Press the button “Check Devices”.
• Now the IO-Link device is displayed. Transfer it then in the project engineering.
• By double-clicking in the user interface of the master or by selecting in the topology you
can change the IODD interpreter.
December 2014
Page 3
IO-Link Device Tool V4.0
3. Software Setup
3.1 User roles
3.1.1 Observer
The parameter selection „observer“ is displayed for the user. Write access is normally not
allowed. This will be defined in the device description of the device manufacturer and may be
different for different devices.
•
The observer is not allowed to change passwords and its validity.
•
There is not default password in the IO-Link device tool for the user role „observer”.
3.1.2 Maintenance
The parameter selection „maintenance“ is displayed for the user. Write access is normally
restricted. This will be defined in the device description of the device manufacturer and may be
different for different devices.
•
In the user role “maintenance” it is not allowed to change passwords and its validity.
•
The default password is ‘maintain‘.
3.1.3 Specialist
The parameter selection „specialist“ is displayed for the user. Write access is normally not
restricted. This will be defined in the device description of the device manufacturer and may be
different for different devices.
•
The specialist is allowed to change passwords and its validity for all user roles.
•
The default password is 'special'.
3.2 Import of the device description IODD
The Device descriptions can be imported from any space into the IO-Link device tool. The
device descriptions have to be checked with a valid checker and must be marked accordingly.
By the import the validity of the IODD XML data will be checked according to the marking
“stamp”. Also all referenced graphic files must be available. Only when the files are complete
and correct the import will start.
At present the IO-Link device tool supports
IODD V1.0.1 for IO-Link devices according to IO-Link V1.0 and
IODD V1.1 for IO-Link devices according to IO-Link V1.1.
IODD V1.0 shall not be used again and is therefore no longer being supported.
December 2014
Page 4
IO-Link Device Tool V4.0
Menu
Description
extras/device description
import
Opens the dialogue „import of the device description”.
Note/Warning: The IO-Link device tool uses a hidden directory as storage location for the
imported IODDs. By the import the IODDs will be copied into it. Similar to a data base it is an
internal working directory of the tool. Please do not copy data in the IO-Link directory on your
own! Please always use the import function or the delete option with the right mouse button.
Only then data consistency can be guaranteed if you create a collection of your used IODDs
independently from the tool.
3.3 IO-Link Device Control
The IO-Link devices will be described by XML device descriptions. These device descriptions
IODD (IO Device Description) will be imported in the device catalogue of the tool. The
configuration and the parameterization can be made both offline and online. The settings are
saved in a project file so that they are available e.g. for the documentation or a device
exchange. The project file will be saved in the project directory with the used device
descriptions.
There are tabs for general product characteristics ("Common"), process data, identification,
observation, parameter and diagnostics.
3.3.1 Tab Common
General information about the IO-Link Device.
Command "DS store"
A "ParamDownloadStore" command is sent to the device. This means that the parameters of
the device are tried to load into the data storage of the IO-Link master. If this is disabled for the
associated port of the IO-Link master, the upload flag remains set until the IO-Link device is
connected to a master whose Data Storage is enabled (upload or Enable). The pre-configured
data of the IO-Link device are then uploaded. So the parameters of an IO-Link device, which is
pre-configured with an USB IO-Link master, will automatically be transferred to the Data
Storage. In a later device replacement then the data from the data storage will be played in the
newly connected device.
Command "Operate"
If the port of the IO-Link master is configured so that the IO-Link device stays in pre-operate
state, the device can be brought into operate state.
December 2014
Page 5
IO-Link Device Tool V4.0
3.3.2 Tab Process Data
The behavior is adjusted according to the IO-Link master and the operation mode.
Offline:
Only the structure of the process data will be displayed. Values will not be displayed
respectively can’t be entered.
Online:
The process input data will be displayed cyclically. Depending on the interface the user
can set if the tool can write the process output data. By the USB IO-Link master the
process output data will always be written from the tool. By the operation with TCI the
process data can only be read. By the stand-alone operation with Ethernet, the tool is in
control if the SPS is not connected.
3.3.3 Tab Identification, Observation, Parameter, Diagnosis
Offline
The structure and the set values of the variables will be displayed. The variable values
can be changed at R/W variables and will be saved in the project.
Online
By changing to online there is no automatic data transfer. With the button „check“ you
can compare the data in the device with those in the project planning. With the buttons
“upload” and “download” you can synchronize the data between tool and device. Only
those device parameters will be transferred that are defined for the relevant active user
role.
If the field „value“ of a variable is selected, the value will be taken from the device and the
display will be updated.
In the context menu (right mouse button) the operation mode for the entering can be set.
So it may be chosen if the value of a changed variable should be transferred immediately
after the entry in the device or if the entries should be collected until they can be
transferred by command (also in the context menu).
3.3.4 Tab Generic
This tab is used to operate the IO-Link device without IODD. The data is displayed as raw data
and the address is set via index and subindex. The standard variables can be accessed easily
by using the pull down table at index.
If no IODD exists, only that tab appears. Otherwise, it is available as a supplement. In particular,
for the programming of the PLC, it is useful since you usually address here via index and
subindex and must work with the raw data.
December 2014
Page 6
IO-Link Device Tool V4.0
4. System Requirements
Hardware recommendations
processor:
dual core 2,5 GHz
working memory:
2 gbytes
hard drive:
500 mbytes free space
monitor:
1024 * 768
According to the IO-Link master
free USB 1.1 or 2.0 interface
Ethernet network interface
Operating system
Windows XP 32
Service Pack 3
Windows 7 32/64
Service Pack 1
Windows 8.1
Microsoft .Net Framework 2.0
By calling via TCI the system requirements of the engineering tool are valid as far as they go
beyond the above mentioned requirements.
5. Appendix
5.1 Used standards and specifications
Available at: www.io-link.com:
IO-Link Communication Specification V1.0
IO-Link Interface and System Specification V1.1.2
IO Device Description V1.0.1 Specification
IO Device Description V1.1 Specification
IO-Link Test Specification V1.1.2
December 2014
Page 7