PDF cT Vus EN 60950-1, UL 60950-1, CSA 60950-1

Attachment to Certificate U8V 10 11 21433 259
VI-abc-de-xx
America
VI-200 DC-DC Series
VI
PRODUCT TYPE
VI = VI (Vicor), VI = VE (Vicor RoHS), VI = IP (VJCL), VI = IE (VJCL RoHS), VI= MI (Mil COTS)
a
Module Type
2 = Drive Module (master)
b = Booster Module (slave)
b
Input Voltage (Vdc)
c
Nominal (Range)
Output Voltage (Vdc)
Nominal
Max(A)
Max(W)
V = 24 (10-36)
Z = 2.0
40A
80W
1 = 24 (21-32)
W = 24 (18-36)
Y = 3.3
0 = 5.0
@ 40A
@ 40A
132W
2 = 36 (21-56)
X = 5.2
@ 38.5A
200W
3 = 48 (42-60)
W = 5.5
@ 36.4.A
200W
N = 48 (36-76)
V = 5.8
@ 34.5A
200W
T = 110 (66-160)
T = 6.5
@ 30.8A
200W
F = 165 (130-260)
R = 7.5
@ 26.6A
200W
5 = 150 (100-200)
M = 10.0
@ 20A
200W
6 = 300 (200-400)
7 = 225 (100-375)
1 = 12.0
P = 13.8
@ 16.7A
@ 14.5A
200W
2 = 15.0
@ 13.3A
200W
N = 18.5
@ 10.8A
200W
@ 8.3A
@ 7.1A
200W
200W
EPT14 inTM
0 = 12 (10-20)
d
Product Grade
-20C to 85C
-40C to 85C
3 = 24.0
L = 28.0
M = Military
-55C to 85C
J = 36.0
@ 5.6A
200W
OC to 85C
K = 40.0
@ 5A
200W
4 = 48.0
@ 4.2A
200W
Output Power /Current
H = 52.0
@ 3.8A
200W
Vout > 5V
Vout < 5V
F = 72.0
@ 2.8A
200W
U=
200W
40A
D = 85.0
@ 2.4A
200W
V=
150W
30A
20A
B = 95.0
@ 2.1A
200W
W = 100W
X = 75W
xx
200W
C = Commercial
I = Industrial
E = Economy
e
200W
15A
Y=
50W
10A
Z=
25W
5A
Options/Specials
F1-F7 = FinMOD (Heatsink)
TM =
BM =
TachoMOD (Non-safety related secondary component changes)
(Battery Module)
S=
SIimMOD (Flangeless Package)
B1 =
V=
BusMOD (screw / lug wiring interface)
Vicor Hybrid (Non-safety related changes), may be followed by -xx denoting 0-99
00-99 = Customer special, unique label or testing, non-safety related changes, d and e are optional for
specials
Test Report No: 090-501807-000
Date,
2011-05-31
Page 2 of 5
TUV SOD AMERICA INC • 10 Centennial Drive • Peabody, MA 01960 USA • www.TUVamerica.com
TuN®
Attachment to Certificate U8V 10 11 21433 259
VI-abccc-deee-xx
America
Mega/Master DC-DC Series
VI
PRODUCT TYPE
VI = VI (Vicor), VI = VE (Vicor RoHS), VI = IP (VJCL), VI = IE (VJCL RoHS), VI = MI (Mil COTS)
a
Product Configuration (maybe followed by "B" = Booster)
L = 1 module, 1 output M = Up to 2 modules, 1 output
P = Up to 2 modules, 2 outputs N = Up to 3 modules, 1 output
R = Up to 3 modules, 3 outputs Q = Up to 3 modules, 2 outputs
c
■
EPTI liElMu
b
d
Input Voltage (Vdc)
Range Nominal
Nominal
0 = 12
10-20
Range
4 = 72
55-100
V = 24
10-36
T = 110
66-160
130-260
1 = 24
21-32
F = 165
W = 24
18-36
5 = 150
100-200
2 = 36
21-56
6 = 300
200-400
3 = 48
42-60
7 = 225
100-375
N = 48
36-76
Output Voltage (Vdc)
Max(A)
Nominal
Max(W)
Nominal
Max(A)
Max(W)
Z
=
2.0
@
40A
80W
2
=
15.0
@
13.3A
200W
Y
=
3.3
@
40A
132W
N
=
18.5
@
10.8A
200W
0
=
5.0
@
40A
200W
3
=
24.0
@
8.3A
200W
X
=
5.2
@
38.5A
200W
L
=
28.0
@
7.1A
200W
W=
V =
5.5
5.8
@
@
36.4.A
34.5A
200W
=
=
36.0
40.0
@
@
5.6A
200W
200W
J
K
5A
200W
T
=
6.5
@
30.8A
200W
4
=
48.0
@
4.2A
200W
R
=
7.5
@
26.6A
200W
H
=
52.0
@
3.8A
200W
M =
10.0 @
F
=
72.0
@
2.8A
200W
12.0 @
20A
16.7A
200W
1
P
200W
D
85.0
@
2.4A
200W
13.8 @
14.5A
200W
B
=
=
95.0
@
2.1A
200W
=
=
eee
Product Grade
-20C to 85C
Vout > 5V
Vout < 5V
Vout > 5V
-40C to 85C
U = 200W
40A
M = 600W
120A
M = Military
-55C to 85C
V = 150W
30A
P = 450W
90A
W = 100W
X = 75W
20A
Q = 400W
80A
Y = 50W
15A
10A
S = 300W
N = 600 W
60A
120A
Z = 25W
5A
E = Economy
xx
Output Power /Current
C = Commercial
I = Industrial
OC to 85C
Vout < 5V
R = 600 W
120A
L = 200 W
40 A
Options/Specials
00-99 = Customer special, unique label or testing, non-safety related changes,
d and e are optional for specials
Test Report No: 090-501807-000
Date,
2011-05-31
Page 3 of 5
TUV SOD AMERICA INC • 10 Centennial Drive • Peabody, MA 01960 USA • www.TUVamerica.com
Attachment to Certificate U8V 10 11 21433 259
C.)
u-
America
CC
VI-200 Series
c-)
MODULE SAFETY INSTRUCTION SHEET
•
1.
O
3.
Input Voltage: Nameplate rating is the nominal input voltage. Vicor guarantees continuous
operation over the entire specified voltage range.
Baseplate Grounding: A ground connection from baseplate to earth / chassis ground is required if
baseplate is operator accessible.
Max Temperature: Keep the maximum baseplate temperature at 85°C or less measured at the
4.
center of the module or the middle mounting slot (negative pin side). Do not exceed 85°C under
any condition.
Overtemperature: If the baseplate temperature exceeds 85°C the module may shutdown. Cool
5.
module down and recycle the input power to restore operation. If the internal temperature of the
module exceeds 95°C the module may be damaged.
Output Voltage Trimming: The module has a maximum allowable Trim of 110% of rated output
2.
C.)
I—
CC
uu
voltage. Do not exceed maximum power output of the module. When trimmed down the
maximum output current remains constant.
Secondary outputs: 48V and below comply with SELV. Outputs 52V to 95Vdc do not meet SELV
requirements.
Fusing Requiremnts: To meet safety requirements, each module input requires a fuse as follows:
6.
I- r
LL •
L
I)
e
VI K A
•
7.
Series
Fuse
VI xOx xx
12A
/
125V
VI xNx xx
8A / 125V
VI-xVx-xx
VI-xlx-xx
VI-xWx-xx
VI-x2x-xx
VI-x3x-xx
12A
12A
12A
8A
8A
/
/
/
/
/
125V
125V
125V
125V
125V
VI-x4x-xx
VI-xTx-xx
VI-x5x-xx
VI-x6x-xx
VI-x7x-xx
-
•
H
1 1 .1.
Fuse
Series
-
-
-
6A / 125V
Buss PC iron 5A
-
Buss PC-iron 5A
Buss PC-Tron 3A
Buss PC-Tron 3A
H
1 1 .1.
Refer to Vicor's Applications Manual for information on proper use of modules.
8.
.?
•
UJ
C.3
LL.
CC
LLI
C.)
•
Test Report No: 090-501807-000
Date,
CIC
2011-05-31
Page 4 of 5
TUV SOD AMERICA INC • 10 Centennial Drive • Peabody, MA 01960 USA • www.TUVamerica.com
Attachment to Certificate U8V 10 11 21433 259
Mega / Master Series
America
MODULE SAFETY INSTRUCTION SHEET
1.
Input Voltage: Nameplate rating is the nominal input voltage. Vicor guarantees continuous operation over the entire
2.
specified voltage range.
Baseplate Grounding: A ground connection from baseplate to earth / chassis ground is required if baseplate is operator
accessible.
3.
Max Temperature: Keep the maximum baseplate temperature at 85°C or less measured at the center of the supply or the
4.
Over temperature: If the baseplate temperature exceeds 85°C the supply may shutdown. Cool supply down and recycle
the input power to restore operation. If the internal temperature of the supply exceeds 95°C the supply may be damaged.
Output Voltage Trimming: The module has a maximum allowable Trim of 110% of rated output voltage. Do not exceed
middle mounting slot (negative pin side). Do not exceed 85°C under any condition.
5.
maximum power output of the module. When trimmed down the maximum output current remains constant.
6.
rLH-UIMIU
►
Vi
7.
Secondary outputs: 48V and below comply with SELV. Outputs 52V to 95Vdc do not meet SELV requirements.
Fusing Requirements: To meet safety requirements the input requires a fuse as follows:
Nominal
Input
Voltage
(Range)
Max P-out
(Pout/module)
150Vdc
(100-375)
300Vdc
(200-400)
150Vdc
(100-200)
110Vdc (66160)
72Vdc
(55-100)
48Vdc
(36-76)
48Vdc
(42-60)
36Vdc
(21-56)
24Vdc
(18-36)
24Vdc
(21-32)
24Vdc
(10-36)
12Vdc
(10-20)
Mega / Master
Series Model
Number
Input Fuse
(Max)
Input Fuse
(Max)
Input Fuse
(Max)
3 module
Config:
N, Q, R
2 module
Config:
M, P
1 module
Config:
L
(100W)
VI-x7xxx-xxxx
PC-Tron 5A
PC-Tron 5A
PC-Tron 3A
600W (200W)
VI-x6xxx-xxxx
PC-Tron 5A
PC-Tron 5A
PC-Tron 3A
600W
(200W)
VI-x5xxx-xxxx
10A,
125V
8A,
125V
PC-Tron 5A
450W
(150W)
VI-xTxxx-xxxx
10A,
125V
8A,
125V
PC-Tron 5A
600W
(200W)
VI-x4xxx-xxxx
15A,
125V
10A,
125V
6A,
125V
600W
(200W)
VI-xNxxx-xxxx
20A,
125V
15A,
125V
8A,
125V
600W
(200W)
VI-x3xxx-xxxx
25A,
125V
15A,
125V
8A,
125V
300W
(100W)
VI-x2xxx-xxxx
25A,
125V
15A,
125V
8A,
125V
450W
(150W)
VI-xWxxx-xxxx
25A,
125V
20A,
125V
12A,
125V
450W
(150W)
VI-xlxxx-xxxx
25A,
125V
20A,
125V
12A,
125V
225W
(75W)
VI-xVxxx-xxxx
25A,
125V
20A,
125V
12A,
125V
225W
(75W)
VI-xOxxx-xxxx
25A,
125V
20A,
125V
12A,
125V
300W
8. Refer to Vicor's Applications Manual for information on proper use of modules.
Test Report No: 090-501807-000
Date,
2011-05-31
Page 5 of 5