Attachment to Certificate U8V 10 11 21433 259 VI-abc-de-xx America VI-200 DC-DC Series VI PRODUCT TYPE VI = VI (Vicor), VI = VE (Vicor RoHS), VI = IP (VJCL), VI = IE (VJCL RoHS), VI= MI (Mil COTS) a Module Type 2 = Drive Module (master) b = Booster Module (slave) b Input Voltage (Vdc) c Nominal (Range) Output Voltage (Vdc) Nominal Max(A) Max(W) V = 24 (10-36) Z = 2.0 40A 80W 1 = 24 (21-32) W = 24 (18-36) Y = 3.3 0 = 5.0 @ 40A @ 40A 132W 2 = 36 (21-56) X = 5.2 @ 38.5A 200W 3 = 48 (42-60) W = 5.5 @ 36.4.A 200W N = 48 (36-76) V = 5.8 @ 34.5A 200W T = 110 (66-160) T = 6.5 @ 30.8A 200W F = 165 (130-260) R = 7.5 @ 26.6A 200W 5 = 150 (100-200) M = 10.0 @ 20A 200W 6 = 300 (200-400) 7 = 225 (100-375) 1 = 12.0 P = 13.8 @ 16.7A @ 14.5A 200W 2 = 15.0 @ 13.3A 200W N = 18.5 @ 10.8A 200W @ 8.3A @ 7.1A 200W 200W EPT14 inTM 0 = 12 (10-20) d Product Grade -20C to 85C -40C to 85C 3 = 24.0 L = 28.0 M = Military -55C to 85C J = 36.0 @ 5.6A 200W OC to 85C K = 40.0 @ 5A 200W 4 = 48.0 @ 4.2A 200W Output Power /Current H = 52.0 @ 3.8A 200W Vout > 5V Vout < 5V F = 72.0 @ 2.8A 200W U= 200W 40A D = 85.0 @ 2.4A 200W V= 150W 30A 20A B = 95.0 @ 2.1A 200W W = 100W X = 75W xx 200W C = Commercial I = Industrial E = Economy e 200W 15A Y= 50W 10A Z= 25W 5A Options/Specials F1-F7 = FinMOD (Heatsink) TM = BM = TachoMOD (Non-safety related secondary component changes) (Battery Module) S= SIimMOD (Flangeless Package) B1 = V= BusMOD (screw / lug wiring interface) Vicor Hybrid (Non-safety related changes), may be followed by -xx denoting 0-99 00-99 = Customer special, unique label or testing, non-safety related changes, d and e are optional for specials Test Report No: 090-501807-000 Date, 2011-05-31 Page 2 of 5 TUV SOD AMERICA INC • 10 Centennial Drive • Peabody, MA 01960 USA • www.TUVamerica.com TuN® Attachment to Certificate U8V 10 11 21433 259 VI-abccc-deee-xx America Mega/Master DC-DC Series VI PRODUCT TYPE VI = VI (Vicor), VI = VE (Vicor RoHS), VI = IP (VJCL), VI = IE (VJCL RoHS), VI = MI (Mil COTS) a Product Configuration (maybe followed by "B" = Booster) L = 1 module, 1 output M = Up to 2 modules, 1 output P = Up to 2 modules, 2 outputs N = Up to 3 modules, 1 output R = Up to 3 modules, 3 outputs Q = Up to 3 modules, 2 outputs c ■ EPTI liElMu b d Input Voltage (Vdc) Range Nominal Nominal 0 = 12 10-20 Range 4 = 72 55-100 V = 24 10-36 T = 110 66-160 130-260 1 = 24 21-32 F = 165 W = 24 18-36 5 = 150 100-200 2 = 36 21-56 6 = 300 200-400 3 = 48 42-60 7 = 225 100-375 N = 48 36-76 Output Voltage (Vdc) Max(A) Nominal Max(W) Nominal Max(A) Max(W) Z = 2.0 @ 40A 80W 2 = 15.0 @ 13.3A 200W Y = 3.3 @ 40A 132W N = 18.5 @ 10.8A 200W 0 = 5.0 @ 40A 200W 3 = 24.0 @ 8.3A 200W X = 5.2 @ 38.5A 200W L = 28.0 @ 7.1A 200W W= V = 5.5 5.8 @ @ 36.4.A 34.5A 200W = = 36.0 40.0 @ @ 5.6A 200W 200W J K 5A 200W T = 6.5 @ 30.8A 200W 4 = 48.0 @ 4.2A 200W R = 7.5 @ 26.6A 200W H = 52.0 @ 3.8A 200W M = 10.0 @ F = 72.0 @ 2.8A 200W 12.0 @ 20A 16.7A 200W 1 P 200W D 85.0 @ 2.4A 200W 13.8 @ 14.5A 200W B = = 95.0 @ 2.1A 200W = = eee Product Grade -20C to 85C Vout > 5V Vout < 5V Vout > 5V -40C to 85C U = 200W 40A M = 600W 120A M = Military -55C to 85C V = 150W 30A P = 450W 90A W = 100W X = 75W 20A Q = 400W 80A Y = 50W 15A 10A S = 300W N = 600 W 60A 120A Z = 25W 5A E = Economy xx Output Power /Current C = Commercial I = Industrial OC to 85C Vout < 5V R = 600 W 120A L = 200 W 40 A Options/Specials 00-99 = Customer special, unique label or testing, non-safety related changes, d and e are optional for specials Test Report No: 090-501807-000 Date, 2011-05-31 Page 3 of 5 TUV SOD AMERICA INC • 10 Centennial Drive • Peabody, MA 01960 USA • www.TUVamerica.com Attachment to Certificate U8V 10 11 21433 259 C.) u- America CC VI-200 Series c-) MODULE SAFETY INSTRUCTION SHEET • 1. O 3. Input Voltage: Nameplate rating is the nominal input voltage. Vicor guarantees continuous operation over the entire specified voltage range. Baseplate Grounding: A ground connection from baseplate to earth / chassis ground is required if baseplate is operator accessible. Max Temperature: Keep the maximum baseplate temperature at 85°C or less measured at the 4. center of the module or the middle mounting slot (negative pin side). Do not exceed 85°C under any condition. Overtemperature: If the baseplate temperature exceeds 85°C the module may shutdown. Cool 5. module down and recycle the input power to restore operation. If the internal temperature of the module exceeds 95°C the module may be damaged. Output Voltage Trimming: The module has a maximum allowable Trim of 110% of rated output 2. C.) I— CC uu voltage. Do not exceed maximum power output of the module. When trimmed down the maximum output current remains constant. Secondary outputs: 48V and below comply with SELV. Outputs 52V to 95Vdc do not meet SELV requirements. Fusing Requiremnts: To meet safety requirements, each module input requires a fuse as follows: 6. I- r LL • L I) e VI K A • 7. Series Fuse VI xOx xx 12A / 125V VI xNx xx 8A / 125V VI-xVx-xx VI-xlx-xx VI-xWx-xx VI-x2x-xx VI-x3x-xx 12A 12A 12A 8A 8A / / / / / 125V 125V 125V 125V 125V VI-x4x-xx VI-xTx-xx VI-x5x-xx VI-x6x-xx VI-x7x-xx - • H 1 1 .1. Fuse Series - - - 6A / 125V Buss PC iron 5A - Buss PC-iron 5A Buss PC-Tron 3A Buss PC-Tron 3A H 1 1 .1. Refer to Vicor's Applications Manual for information on proper use of modules. 8. .? • UJ C.3 LL. CC LLI C.) • Test Report No: 090-501807-000 Date, CIC 2011-05-31 Page 4 of 5 TUV SOD AMERICA INC • 10 Centennial Drive • Peabody, MA 01960 USA • www.TUVamerica.com Attachment to Certificate U8V 10 11 21433 259 Mega / Master Series America MODULE SAFETY INSTRUCTION SHEET 1. Input Voltage: Nameplate rating is the nominal input voltage. Vicor guarantees continuous operation over the entire 2. specified voltage range. Baseplate Grounding: A ground connection from baseplate to earth / chassis ground is required if baseplate is operator accessible. 3. Max Temperature: Keep the maximum baseplate temperature at 85°C or less measured at the center of the supply or the 4. Over temperature: If the baseplate temperature exceeds 85°C the supply may shutdown. Cool supply down and recycle the input power to restore operation. If the internal temperature of the supply exceeds 95°C the supply may be damaged. Output Voltage Trimming: The module has a maximum allowable Trim of 110% of rated output voltage. Do not exceed middle mounting slot (negative pin side). Do not exceed 85°C under any condition. 5. maximum power output of the module. When trimmed down the maximum output current remains constant. 6. rLH-UIMIU ► Vi 7. Secondary outputs: 48V and below comply with SELV. Outputs 52V to 95Vdc do not meet SELV requirements. Fusing Requirements: To meet safety requirements the input requires a fuse as follows: Nominal Input Voltage (Range) Max P-out (Pout/module) 150Vdc (100-375) 300Vdc (200-400) 150Vdc (100-200) 110Vdc (66160) 72Vdc (55-100) 48Vdc (36-76) 48Vdc (42-60) 36Vdc (21-56) 24Vdc (18-36) 24Vdc (21-32) 24Vdc (10-36) 12Vdc (10-20) Mega / Master Series Model Number Input Fuse (Max) Input Fuse (Max) Input Fuse (Max) 3 module Config: N, Q, R 2 module Config: M, P 1 module Config: L (100W) VI-x7xxx-xxxx PC-Tron 5A PC-Tron 5A PC-Tron 3A 600W (200W) VI-x6xxx-xxxx PC-Tron 5A PC-Tron 5A PC-Tron 3A 600W (200W) VI-x5xxx-xxxx 10A, 125V 8A, 125V PC-Tron 5A 450W (150W) VI-xTxxx-xxxx 10A, 125V 8A, 125V PC-Tron 5A 600W (200W) VI-x4xxx-xxxx 15A, 125V 10A, 125V 6A, 125V 600W (200W) VI-xNxxx-xxxx 20A, 125V 15A, 125V 8A, 125V 600W (200W) VI-x3xxx-xxxx 25A, 125V 15A, 125V 8A, 125V 300W (100W) VI-x2xxx-xxxx 25A, 125V 15A, 125V 8A, 125V 450W (150W) VI-xWxxx-xxxx 25A, 125V 20A, 125V 12A, 125V 450W (150W) VI-xlxxx-xxxx 25A, 125V 20A, 125V 12A, 125V 225W (75W) VI-xVxxx-xxxx 25A, 125V 20A, 125V 12A, 125V 225W (75W) VI-xOxxx-xxxx 25A, 125V 20A, 125V 12A, 125V 300W 8. Refer to Vicor's Applications Manual for information on proper use of modules. Test Report No: 090-501807-000 Date, 2011-05-31 Page 5 of 5 TON/ SOD AMERICA INC • 10 Centennial Drive • Peabody, MA 01960 USA • www.TUVamerica.com