B 10 10 34962 104

CERTIFICATE
America
No. B 10 10 34962 104
Holder of Certificate: SynQor Inc.
155 Swanson Road
Boxborough, MA 01719-1316
USA
Production
Facility(ies):
34962
Certification Mark:
Product:
IT Equipment
Power Interface Module
Model(s):
1Q65033QMA10
(see certificate attachment for license conditions)
Parameters:
36-75 V DC
Rated Input Voltage:
10 A
Rated Input Current:
300 Watts max.
Rated Output Current:
IPXO
Degree of Protection:
(See attachment for additional rating information.)
Tested according to:
EN 60950-1/A1:2010
The product was tested on a voluntary basis and complies with the essential requirements. The
certification mark shown above can be affixed on the product. It is not permitted to alter the
certification mark in any way. In addition the certification holder must not transfer the certificate
to third parties. See also notes overleaf.
Test report no.:
Date,
090-700863-000
2010-10-21
Page 1 of 2
422877
TUV SOD AMERICA INC • 10 Centennial Drive • Peabody, MA 01960 USA • www.TUVamerica.com
Attachment to Certificate No.: B 10 10 34962 104
Company:
SynQor Inc.
155 Swanson Road
Boxborough, MA 01719-1316 USA
America
Rating Information:
36-75 Vdc, 7.5 A, 400 LFM
48 Vdc, 10 A, 950 LFM
Outputs:
IMP 3.3 Vdc 3.6 A, 5.0 Vdc, 150 mA
License Conditions:
When installed in the end product, consideration shall be given to the following:
1. The units should be installed per the manufacturer's specification.
2. Maximum output power is specified at 25°C and 950 LFM at normal voltage of 48 VDC,
3. Maximum output power is specified at 25°C and 400 LFM at normal voltage of 36-75 VDC.
4.
Abnormal and Component Failure Tests were conducted with the power supply input protected by a
3 AG 15 A, 250 V fuse. If a fuse rated greater than 3AG 15 A is used, additional testing may be required.
5. If the input meets all of the requirements for SELV (V < 60), the outputs may be considered SELV.
Output voltages remain within SELV limits.
11111:3
R=.-3
6. These units are intended to be supplied from an isolated source of supply, such as a battery, or a
source which meets the requirements for basic (ELV) or reinforced (SELV) insulation from primary
(mains) circuitry, depending on output type desired.
Test Report No.: 090-700863-000
Date: 2010-10-21
Page 2 of 2
TON/ SOD AMERICA INC • 10 Centennial Drive • Peabody, MA 01960 USA • www.TUVamerica.com
TEA/c)