T4J Series Datasheet

T4J – Medical Series
HRC4000 Implantable Non Life Support and Non Implantable Life Support
The AVX T4J series is designed for use in Implantable - Non-Life
support or Non-Implantable - Life support medical applications.
These components are screened using our newly designed
Q-Process to effectively remove components that may experience parametric shifts through customer processing or display
instability through life testing.
LEAD-FREE COMPATIBLE
COMPONENT
For RoHS compliant products,
please select correct termination style.
FEATURES
• Dedicated to medical applications
• HRC4000 - Implantable, Non-Life support
- Non-Implantable, Life support
• -55 to +125°C operation temperature
• Basic reliability better than 0.1%/1000hours
• Custom DCL / ESR options on selected parts
T4J Standard – Standard option DCL and ESR limits including Q-Process screening.
T4J Custom – A custom option where specific DCL and ESR parameter limits can be
agreed based Q-Process statistical screening. DCL down to 0.005CV on selected codes
L
W
APPLICATIONS
• Medical, Implantable - Non-Life support and Non-Implantable - Life support
H
For additional information on Q-process please consult the AVX technical publication “Reaching the
Highest Reliability for Tantalum Capacitors” (see the link: http://www.avx.com/docs/techinfo/Qprocess.pdf)
A
S
A
W1
CASE DIMENSIONS: millimeters (inches)
MARKING
A, B, C, D, E, U CASE
AVX LOGO
Polarity
Band
(Anode+)
Capacitance Value in pF
227 = 220µF
227 A
XXXXX
Rated Voltage Code
A = 10V
ID Code
Code
EIA
Code
EIA
Metric
L±0.20
(0.008)
W+0.20 (0.008)
–0.10 (0.004)
H+0.20 (0.008)
–0.10 (0.004)
W1±0.20
(0.008)
A+0.30 (0.012)
–0.20 (0.008)
S Min.
A
1206
3216-18 3.20 (0.126)
1.60 (0.063)
1.60 (0.063)
1.20 (0.047)
0.80 (0.031)
1.10 (0.043)
B
1210
3528-21 3.50 (0.138)
2.80 (0.110)
1.90 (0.075)
2.20 (0.087)
0.80 (0.031)
1.40 (0.055)
C
2312
6032-28 6.00 (0.236)
3.20 (0.126)
2.60 (0.102)
2.20 (0.087)
1.30 (0.051)
2.90 (0.114)
D
2917
7343-31 7.30 (0.287)
4.30 (0.169)
2.90 (0.114)
2.40 (0.094)
1.30 (0.051)
4.40 (0.173)
E
2917
7343-43 7.30 (0.287)
4.30 (0.169)
4.10 (0.162)
2.40 (0.094)
1.30 (0.051)
4.40 (0.173)
U
2924
7361-43 7.30 (0.287)
6.10 (0.240)
4.10 (0.162)
3.10 (0.120)
1.30 (0.051)
4.40 (0.173)
W1 dimension applies to the termination width for A dimensional area only.
CAPACITANCE AND RATED VOLTAGE, VR (VOLTAGE CODE) RANGE (LETTER DENOTES CASE SIZE)
Capacitance
μF
Code
1.0
105
1.5
155
2.2
225
3.3
335
4.7
475
6.8
685
10
106
15
156
22
226
33
336
47
476
68
686
100
107
150
157
220
227
330
337
470
477
680
687
6.3V (J)
A
A
B
B
B/C
B/C
B/C
D
D
E
E
U
10V (A)
A
A
B
B
C
C
C
D
D
E
E
U
Available Ratings
Engineering samples - please contact manufacturer
*Codes under development
Please contact the factory for codes not listed in the table.
62
Rated Voltage DC (VR ) to 85°C (Voltage Code)
16V (C)
20 (D)
25 (E)
A*
B
B
B
C
C
D
D
E
E
U
A*
B
B
B/C
C
C
D
D
E
E
A
B
B
B
C
C
C
D
D
D
35 (V)
A
B
B
B
C
C
C
D
D
E
50V (T)
C
C
C
C
D
D
E
Note: Voltage ratings are minimum values. AVX reserves the right to supply higher
ratings in the same case size, to the same reliability standards with customer
written approval.
042016
T4J – Medical Series
HRC4000 Implantable Non Life Support and Non Implantable Life Support
HOW TO ORDER
T4J
E
336
Type
Case Size
See table above
K
Capacitance
Tolerance
Code
K = ±10%
pF code:
1st two digits represent
significant figures
3rd digit represents multiplier
(number of zeros to follow)
035
Rated DC
Voltage
006 = 6.3Vdc
010 = 10Vdc
016 = 16Vdc
020 = 20Vdc
025 = 25Vdc
035 = 35Vdc
050 = 50Vdc
C
L
Q
4
^
00
Standard or Packaging
Termination
Suffix
Inspection
Reliability
Qualification
Low ESR R = 7" Reel
Level
Grade
Level
7 = 100% Tin
00 = Standard
Range
L = Lab Inspection Q = Q-Process 4 = HCR4000 9 = Gold Plated
XX = Custom
B = Bulk
C = Std ESR
Screening
H = SnPb Non RoHS
L = Low ESR
H,9 = (Contact
Manufacturer)
Non RoHS
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Leakage Current DCL:
Rated Voltage (VR)
Category Voltage (VC)
Surge Voltage (VS)
Surge Voltage (VS)
Temperature Range:
Reliability:
042016
All technical data relate to an ambient temperature of +25ºC
1 μF to 680 μF
±10%
0.01CV (Custom potential down to 0.005CV available upon request)
85°C:
6.3
10
16
20
25
35
50
125°C:
4
7
10
13
17
23
33
85°C:
8
13
20
26
32
46
65
125°C:
5
8
13
16
20
28
40
-55°C to +125°C
0.1% / 1000hrs at 25°C, VR with 0.1Ω/V series impedance, 90% confidence level
63
T4J – Medical Series
HRC4000 Implantable Non Life Support and Non Implantable Life Support
RATINGS & PART NUMBER REFERENCE
AVX
Part No.
Case Capacitance
Size
(μF)
Rated
Rated
Category Category
Voltage Temperature Voltage Temperature
(V)
(ºC)
(V)
(ºC)
T4JA106K006CLQ4^00
T4JA156K006CLQ4^00
T4JB226K006CLQ4^00
T4JB336K006CLQ4^00
T4JB476K006CLQ4^00
T4JC476K006CLQ4^00
T4JB686K006CLQ4^00
T4JC686K006CLQ4^00
T4JB107K006CLQ4^00
T4JC107K006CLQ4^00
T4JD157K006CLQ4^00
T4JD227K006CLQ4^00
T4JE337K006CLQ4^00
T4JE477K006CLQ4^00
T4JU687K006CLQ4^00
A
A
B
B
B
C
B
C
B
C
D
D
E
E
U
10
15
22
33
47
47
68
68
100
100
150
220
330
470
680
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
6.3
85
85
85
85
85
85
85
85
85
85
85
85
85
85
85
T4JA685K010CLQ4^00
T4JA106K010CLQ4^00
T4JB156K010CLQ4^00
T4JB226K010CLQ4^00
T4JC336K010CLQ4^00
T4JC476K010CLQ4^00
T4JC686K010CLQ4^00
T4JD107K010CLQ4^00
T4JD157K010CLQ4^00
T4JE227K010CLQ4^00
T4JE337K010CLQ4^00
T4JU477K010CLQ4^00
A
A
B
B
C
C
C
D
D
E
E
U
6.8
10
15
22
33
47
68
100
150
220
330
470
10
10
10
10
10
10
10
10
10
10
10
10
85
85
85
85
85
85
85
85
85
85
85
85
T4JB685K016CLQ4^00
T4JB106K016CLQ4^00
T4JB156K016CLQ4^00
T4JC226K016CLQ4^00
T4JC336K016CLQ4^00
T4JD476K016CLQ4^00
T4JD686K016CLQ4^00
T4JE107K016CLQ4^00
T4JE157K016CLQ4^00
T4JU227K016CLQ4^00
B
B
B
C
C
D
D
E
E
U
6.8
10
15
22
33
47
68
100
150
220
16
16
16
16
16
16
16
16
16
16
85
85
85
85
85
85
85
85
85
85
T4JB475K020CLQ4^00
T4JB685K020CLQ4^00
T4JB106K020CLQ4^00
T4JB106K020LLQ4^00
T4JC106K020CLQ4^00
T4JC156K020CLQ4^00
T4JC226K020CLQ4^00
T4JD336K020CLQ4^00
T4JD476K020CLQ4^00
T4JE686K020CLQ4^00
T4JE107K020CLQ4^00
B
B
B
B
C
C
C
D
D
E
E
4.7
6.8
10
10
10
15
22
33
47
68
100
20
20
20
20
20
20
20
20
20
20
20
85
85
85
85
85
85
85
85
85
85
85
64
6.3 Volt @ 85°C
4
125
4
125
4
125
4
125
4
125
4
125
4
125
4
125
4
125
4
125
4
125
4
125
4
125
4
125
4
125
10 Volt @ 85°C
7
125
7
125
7
125
7
125
7
125
7
125
7
125
7
125
7
125
7
125
7
125
7
125
16 Volt @ 85°C
10
125
10
125
10
125
10
125
10
125
10
125
10
125
10
125
10
125
10
125
20 Volt @ 85°C
13
125
13
125
13
125
13
125
13
125
13
125
13
125
13
125
13
125
13
125
13
125
DCL
Max.
(μA)
DF
Max.
(%)
ESR
Max.
@ 100kHz
(mΩ)
MSL
0.6
0.9
1.4
2.1
2.8
3.0
4.0
4.3
3.0
6.3
9.5
13.9
20.8
29.6
42.8
6
6
6
6
8
6
8
6
10
6
6
8
8
8
12
1500
1500
600
600
1500
300
900
300
1400
300
200
200
200
200
250
0.7
1
1.5
2.2
3.3
4.7
6.8
10.0
15.0
22.0
33.0
47.0
6
6
6
6
6
6
6
6
8
8
8
12
1.1
1.6
2.4
3.5
5.3
7.5
10.9
16.0
24.0
35.2
1.0
1.4
1.0
1.0
2.0
3.0
4.4
6.6
9.4
13.6
20.0
100kHz RMS Current (mA)
25ºC
85ºC
125ºC
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
224
224
376
376
238
606
307
606
246
606
866
866
908
908
812
201
201
339
339
214
545
277
545
222
545
779
779
817
817
731
89
89
151
151
95
242
123
242
99
242
346
346
363
363
325
2000
2000
700
700
300
300
300
150
150
150
150
200
3
3
3
3
3
3
3
3
3
3
3
3
194
194
348
348
606
606
606
1000
1000
1049
1049
908
174
174
314
314
545
545
545
900
900
944
944
817
77
77
139
139
242
242
242
400
400
420
420
363
6
6
6
6
6
6
6
6
6
12
1200
1200
1200
350
350
200
200
150
150
200
3
3
3
3
3
3
3
3
3
3
266
266
266
561
561
866
866
1049
1049
908
240
240
240
505
505
779
779
944
944
817
106
106
106
224
224
346
346
420
420
363
6
6
6
6
6
6
6
6
6
6
6
1000
1000
1000
500
500
500
500
250
250
200
200
3
3
3
3
3
3
3
3
3
3
3
292
292
292
412
469
469
469
775
775
908
908
262
262
262
371
422
422
422
697
697
817
817
117
117
117
165
188
188
188
310
310
363
363
042016
T4J – Medical Series
HRC4000 Implantable Non Life Support and Non Implantable Life Support
AVX
Part No.
Case Capacitance
Size
(μF)
Rated
Rated
Category Category
Voltage Temperature Voltage Temperature
(V)
(ºC)
(V)
(ºC)
T4JA155K025CLQ4^00
T4JB225K025CLQ4^00
T4JB335K025CLQ4^00
T4JB475K025CLQ4^00
T4JC685K025CLQ4^00
T4JC106K025CLQ4^00
T4JC156K025CLQ4^00
T4JD226K025CLQ4^00
T4JD336K025CLQ4^00
T4JD476K025CLQ4^00
A
B
B
B
C
C
C
D
D
D
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
25
25
25
25
25
25
25
25
25
25
85
85
85
85
85
85
85
85
85
85
T4JA105K035CLQ4^00
T4JA105K035LLQ4^00
T4JB155K035CLQ4^00
T4JB225K035CLQ4^00
T4JB335K035CLQ4^00
T4JC475K035CLQ4^00
T4JC685K035CLQ4^00
T4JC106K035CLQ4^00
T4JD156K035CLQ4^00
T4JD226K035CLQ4^00
T4JE336K035CLQ4^00
A
A
B
B
B
C
C
C
D
D
E
1.0
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
35
35
35
35
35
35
35
35
35
35
35
85
85
85
85
85
85
85
85
85
85
85
T4JC105K050CLQ4^00
T4JC155K050CLQ4^00
T4JC225K050CLQ4^00
T4JC335K050CLQ4^00
T4JD475K050CLQ4^00
T4JD685K050CLQ4^00
T4JE106K050CLQ4^00
C
C
C
C
D
D
E
1
1.5
2.2
3.3
4.7
6.8
10
50
50
50
50
50
50
50
85
85
85
85
85
85
85
25 Volt @ 85°C
17
125
17
125
17
125
17
125
17
125
17
125
17
125
17
125
17
125
17
125
35 Volt @ 85°C
23
125
23
125
23
125
23
125
23
125
23
125
23
125
23
125
23
125
23
125
23
125
50 Volt @ 85°C
33
125
33
125
33
125
33
125
33
125
33
125
33
125
DCL
Max.
(μA)
DF
Max.
(%)
ESR
Max.
@ 100kHz
(mΩ)
MSL
0.4
0.6
0.8
1.2
1.7
2.5
3.8
5.5
8.3
11.8
6
6
6
6
6
6
6
6
6
6
3000
2000
2000
2000
600
600
600
400
400
400
0.4
0.2
0.5
0.8
1.2
1.6
2.4
3.5
5.3
7.7
11.6
6
6
6
6
6
6
6
6
6
6
6
0.5
0.8
1.1
1.7
2.4
3.4
5.0
4
6
6
6
4.5
4.5
4.5
100kHz RMS Current (mA)
25ºC
85ºC
125ºC
3
3
3
3
3
3
3
3
3
3
158
206
206
206
428
428
428
612
612
612
142
186
186
186
385
385
385
551
551
551
63
82
82
82
171
171
171
245
245
245
3000
1000
2500
2500
2500
600
600
600
400
400
250
3
3
3
3
3
3
3
3
3
3
3
158
274
184
184
184
428
428
428
612
612
812
142
246
166
166
166
385
385
385
551
551
731
63
110
74
74
74
171
171
171
245
245
325
1500
1500
1500
1500
600
600
400
3
3
3
3
3
3
3
271
271
271
271
500
500
642
244
244
244
244
450
450
578
108
108
108
108
200
200
257
Moisture Sensitivity Level (MSL) is defined according to J-STD-020.
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is
measured at rated voltage after 5 minutes.
The EIA & CECC standards for low ESR Solid Tantalum Capacitors allow an ESR movement to 1.25 times catalogue limit post mounting.
042016
65
T4J – Medical Series
HRC4000 Implantable Non Life Support and Non Implantable Life Support
QUALIFICATION TABLE
TEST
Endurance
Storage Life
Temperature
Stability
T4J HRC4000 (Temperature range -55ºC to +125ºC)
Characteristics
Determine after application of rated voltage for 2000
Visual examination
no visible damage
+48/-0 hours at 85±2ºC and then leaving 1-2 hours
DCL
1.25 x initial limit
at room temperature. Also determine of 125ºC temΔC/C
within ±10% of initial value
perature, category voltage for 2000 +48/-0 hours
DF
initial limit
and then leaving 1-2 hours at room temperature.
Power supply impedance to be ≤0.1Ω/V.
ESR
1.25 x initial limit
Visual examination
no visible damage
DCL
1.25 x initial limit
125ºC, 0V, 2000h
ΔC/C
within ±10% of initial value
DF
initial limit
ESR
1.25 x initial limit
Step
Temperature°C
Duration (min)
+20ºC -55ºC +20ºC +85ºC
1
+20±2
15
DCL
IL*
n/a
IL*
10 x IL*
2
-55+0/-3
15
ΔC/C
n/a
+0/-10% ±5% +10/-0%
3
+20±2
15
4
+85+3/-0
15
DF
IL*
1.5 x IL*
IL*
1.5 x IL*
Condition
5
6
Surge
Voltage
+125+3/-0
+20±2
15
15
Test temperature: 125ºC+3/0ºC
Test voltage: Category voltage at 125ºC
Surge voltage: 1.3x category voltage at 125ºC
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6min; 30 sec charge,
5min 30 sec discharge
ESR
+125ºC +20ºC
12.5 x IL* IL*
+12/-0% ±5%
2 x IL*
IL*
1.25 x IL* 2.5 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL*
Visual examination
no visible damage
DCL
initial limit
ΔC/C
within ±5% of initial value
DF
initial limit
ESR
1.25 x initial limit
*Initial Limit
LOT ACCEPTANCE TESTING
TEST
Lot
Acceptance
Test
66
T4J HRC4000 (Temperature range -55ºC to +125ºC)
Characteristics
25 Pieces from each lot
DCL
initial limit
• Read and Record Initial Electricals
ΔC/C
within ±5% of initial value
• Bake Out @ 125ºC for 2 Hours
• Mount using AVX recommended profile
DF
initial limit
• Read and Record Post Mounting Electricals
ESR
1.25 x initial limit
• Life Test: 6 hours, 2/3 R.V., 125ºC
• Read and Record Post Electricals
0 Failures Allowed
Condition
042016