Model 4238 Instruction Manual

IM-360
INSTALLATION & OPERATING
INSTRUCTIONS
Model 4238
GaAs Switched
Programmable Attenuators
This documentation may not be reproduced in any form, for any
purpose unless authorized in writing by Aeroflex / Weinschel, Inc..
© Aeroflex / Weinschel, Inc.
Frederick, Maryland
2002, 2006, 2008, 2013
REV. D, 2/14/2013
IM-360
GENERAL
This manual provides general installation instructions and wiring data to be used as an aid in
installing the Aeroflex / Weinschel Model 4238
Series GaAs Switched Programmable Attenuators
into any subsystem or application. Also included
are specifications and other technical data to help
in the installation and operation of your 4238
Series Programmable Attenuator.
CONTROL CONFIGURATION: Units are supplied with a built-in TTL interface.
Each unit is supplied with a mating 10 pin connector (Amp 746285-1). Refer to
connector pin/wiring for mating details. Two wires are specified for supply voltage
and ground. The remaining wires will accept TTL control signals to activate or deactivate a particular attenuation cell. A TTL high will energize a cell to the high
attenuation state, whereas a TTL low will maintain a cell in its zero attenuation
state.
CELL CONFIGURATION
The table below list all the standard attenuation ranges and cell configurations for
Aeroflex / Weinschel Model 4238 Series GaAs Switched Programmable
Attenuators. Note the dash number is the attenuation value of your attenuator.
Model
Number
NO.
Cells
Attenuation
Range/Steps
(dB)
4238-103
8
103/1
4238-63.75
8
63.75/0.25
2
Cell
Increments
(dB)
1, 2, 4, 8, 16, 24, 48
0.25, 0.5, 1, 2, 4, 8, 16, 32
GaAs Switched Programmable Attenuators
INSTALLATION
MOUNTING: Each Programmable Attenuator is supplied with two #4-40 UNC-2B
X3.0 [0.12] mounting holes on either side of the attenuator. There are also two
#2-56 UNC-2B X 3.0 [0.12] on the top and bottom of the attenuator which allows
the attenuator to be mounted in any direction.
RF CABLE INSTALLATION: Care should be taken to prevent strain on the interconnecting cables, since damage here may not always be apparent. Check the
attaching RF cables and the SMA connectors for signs of cracked insulation
and/or bent or worn pins prior to connection. Tests show that connectors must be
clean for accuracy and stability. This requires an inspection and cleaning of each
connector immediately before use. When cleaning precautions are observed regularly, connectors can maintain their stability for over several thousand
connection cycles. Aeroflex / Weinschel recommends a torque value of 7 to 10
inch pounds when connecting any RF cable to the attenuator's RF connectors.
CONTROL CONNECTOR PIN/WIRING: The table below shows the connectors
contact pin numbering scheme and the signal designator for signal present at
each contact pin.
Control Connector J3 Pin Locations:
J3
TTL Conn
4238-63.75
PIN No. (J3)
dB (Cell)
PIN 2
PIN 1
4238-103
dB (Cell)
1
0.25
1
2
0.50
2
3
1
4
4
2
8
5
4
16
6
8
24
7
16
48
8
32
NC*
9
+5V
+5V
10
COM
COM
NC = Not Connected
* For Factory use only.
3
IM-360
SPECIFICATIONS
NOMINAL IMPEDANCE:
50 Ω
FREQUENCY RANGE:
10 MHz to 2.5 GHz, usable dc to 10 MHz with
reducded specifications
SWR (Maximum):
0.01 - 0.20
0.20 - 2.5
MONOTONICITY:
10 MHz to 2.5 GHz
1.75
1.40
CELL
0.25
0.50
1
2
4
8
16
24
32
48
dB
+0.15
+0.15
+0.2
+0.2
+0.2
+0.2
+0.3
+0.4
+0.6
+0.8
INCREMENTAL ATTENUATION ACCURACY:
0.01 - 1.0
INSERTION LOSS, Maximum (dB):
1.0 - 2.0
2.0 - 2.5
6.75
8.25
9.25
3rd ORDER INTERMODULATION (IM3): -60 dBm typical, measured with two +27 dBm
tones @ 869 MHz (f1) and 894 MHz (f2), the IM3 frequeny being 847 MHz (2fl-f2).
IP3 (input) = +65 dBm
The input IP3 is derived from the following relationship:
IP3 = 3(Pin-α)-IM3 + α
2
where α = the insertion loss (dB) at the IM3 frequency; Pin=single tone input power (dBm).
INPUT POWER RATING:
+30 dBm
OPERATING VOLTAGE:
+5 to +15 V
OPERATING CURRENT:
25 mA typical
TEMPERATURE RANGE (Operating):
0°C to +70°C
TEMPERATURE COEFFICIENT:
0.002 dB/dB/°C
CONNECTORS:
SMA female connectors - mate nondestructively with
MIL-C-39012 connectors.
CONTROL CONNECTOR: AMP-Latch 10 pin ribbon cable connector mates with
AMP P/N 746285-1 (supplied with each unit)
WEIGHT:
4
4238-X
150 g (5.3 oz)
GaAs Switched Programmable Attenuators
PHYSICAL DIMENSIONS:
J1
J2
J3
NOTE:
All dimensions are given in mm (inches) and are maximum, unless otherwise specified.
IM-360
Aeroflex / Weinschel Warranty
PRODUCTS: Aeroflex / Weinschel warrants each product it manufactures to be
free from defects in material and workmanship under normal use and service anywhere in the world. Weinschel's only obligation under this Warranty is to repair or
replace, at its plant, any product or part thereof that is returned with transportation charges prepaid to Aeroflex / Weinschel by the original purchaser within ONE
YEAR from the date of shipment.
The foregoing Warranty does not apply to, and in Aeroflex / Weinschel's sole opinion, products that have been subject to improper or inadequate maintenance,
unauthorized modifications, misuse, or operation outside the environmental specifications for the product.
SOFTWARE PRODUCTS: Aeroflex / Weinschel software products are supplied
without representation or Warranty of any kind. Aeroflex / Weinschel, therefore,
assumes no responsibility and will not accept liability (consequential or otherwise)
arising from the use of program materials, disk, or tape.
The Warranty period is controlled by the Warranty document furnished with each
product and begins on the date of shipment. All Warranty returns must be authorized by Aeroflex / Weinschel prior to their return.
Aeroflex / Weinschel's Quality System Certified to:
6
GaAs Switched Programmable Attenuators
CONTACTING Aeroflex/ Weinschel
In the event you're having difficulty or believe that the components are defective,
please contact Weinschel immediately. An apparent malfunction may be
corrected over the phone by contacting the Customer Service Department at
Weinschel. DO NOT send the product back to the factory without prior authorization (RMA number). When it is necessary to return an item, state the symptoms
or problems, catalog and type number of the attenuator, and date of original purchase. Also write the company name, your name, and phone number on an index
card. Then attach the card to the attenuator to be returned.
For more information or any questions about your Programmable Step
Attenuators and/or other Aeroflex / Weinschel products, contact the Sales
Department at Aeroflex / Weinschel.
7
IM-360
5305 Spectrum Drive, Frederick, Maryland 21703-7362
TEL: (301) 846-9222, 800-638-2048, FAX: (301) 846-9116
Web: www.aeroflex.com/weinschel, e-mail: [email protected]
© 2002, 2006, 2008, 2013 Aeroflex / Weinschel, Inc.