English Datasheet

PRODUCT DATASHEET
EX850 TRMS 1000A AC/DC
Clamp Meter for Android™
Monitor Readings via Bluetooth®
Clamp meter transmits readings to Android
smartphones and tablets
View key electrical readings taken by the EX850 at a safe distance
on your Android device. Power up equipment from remote switches
or use your Android to show readings to a customer/manager.
Download the Extech ExView™ EX850 App
at play.google.com
Features
•
Integrated Bluetooth® connects with most Android
devices to transmit readings for remote viewing
•
Works with free Android App to display large, easyto-read values for: AC/DC voltage, AC/DC current,
capacitance, resistance, frequency, diode test, and
temperature (Type-K & infrared), up to 30’ (10m) away
•
Non-contact IR Thermometer design with laser pointer
•
CAT IV safety rating for industrial applications
•
True RMS Current and Voltage measurements
•
Peak hold captures inrush currents and Transients
•
1.7" (43mm) jaw opening for conductors up to
750MCM or two 500MCM
•
4000 count backlit display
•
Autoranging with manual range button
•
Data Hold, Min/Max and Auto Power off
•
Complete with CAT IV test leads, 9V battery,
CAT IV -600V safety rating for added protection and True RMS
feature gives you accurate readings of non-sinusoidal waveforms.
Built-in IR Thermometer with laser pointer is an excellent
troubleshooter for locating hot spots and overheating motors.
general purpose Type K probe, and pouch case
See back page for meter specifications
Android & Google Play are trademarks of Google Inc. The Android robot is reproduced or modified from work created
and shared by Google and used according to terms described in the Creative Commons 3.0 Attribution License.
Specifications subject to change without notice. Copyright © 2012-2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form.
Rev. 11/15/13
www.extech.com
Specifications
Range
Basic Accuracy
AC/DC Current
0.1 to 1000A
±2.8%
AC/DC Voltage
0.1mV to 1000V
AC: ±1.5%; DC: ±2.8%
Resistance
0.1 to 40MΩ
±1.5%
Capacitance
0.001nF to 40,000μF
±3.0%
Frequency
0.001kHz to 4kHz
±1.5%
IR Temperature
-58 to 518ºF (-50 to 270ºC)
±2.0% rdg or ±4ºF/±2ºC
Type K Temperature
-4 to 1400ºF (-20 to 760ºC)
±(3%rdg+9°F/5ºC)
Continuity
Yes
Inrush
Yes
Diode
Yes
Dimensions/Weight
10.6x4.3x2" (270x110x50mm)/ 13.6oz (386g)
Ordering
EX850 ............... True RMS 1000A AC/DC Clamp Meter for Android™
Specifications subject to change without notice. Copyright © 2012-2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form.
www.extech.com