PRODUCT DATASHEET PRC30 Multifunction Process Calibrator Precision source and measure for thermocouples (8-Types), mA, mV, and V devices Applications include: • Lab and Field Calibration and Verification Operations of Sensors, Thermocouple Probes, Controllers, Panel meters & Testing tools. • Temperature Control Process Troubleshooting • Process devices calibration and simulation: Transducers, Transmitters, Indicators, Controllers, and Recorders • Field test and service • Bench research and development Features • Palm-sized double molded housing and large dot-matrix backlit LCD • Measures DC process signals • High accuracy calibration function simulates precision thermocouple outputs for use in calibrating thermometers, transmitters, controllers or recorders • Up to five user adjustable calibration presets • Displays output in terms of millivolts or temperature based on thermocouple tables • 24V Loop Power • Zero adjustment, auto zero when power on and change mode • Standard banana I/O ports and mini thermocouple inputs • Large battery bank for extended work cycle • External power adapter for continuous work cycle Complete with test leads, alligator clips, Thermocouple calibration cable with subminiature connector, universal calibration cable with subminiature terminal, 100V-240V AC Universal Adaptor with 4 plugs, six 1.5V AA batteries, and hard carrying case Ordering PRC30 .................Multifunction Process Calibrator PRC30-NIST ........PRC30 with Certificate of Calibration Traceable to NIST Specifications subject to change without notice. Copyright © 2012-2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. Rev. 4/2/14 www.extech.com Specifications Range Basic Accuracy Current 0 to 24mA, -25% to +125% ±(0.01% + 1 digit) Max. Load 1000Ω @ 24mA DC Source Voltage 0 to 2000mV, 0 to 20V ±(0.01% + 1 digit) mV/Temp -5 to 55mV ±(0.01% + 1 digit) Type J -58 to 1832°F (-50 to 1000°C) ±(0.05% + 2°F or 1°C) Type K -58 to 2498°F (-50 to 1370°C) ±(0.05% + 2°F or 1°C) Type T -184 to 752°F (-120 to 400°C) ±(0.05% + 2°F or 1°C) Type E -58 to 1382°F (-50 to 750°C) ±(0.05% + 2°F or 1°C) Type C, R, S 32 to 3182°F (0 to 1750°C) ±(0.05% + 2°F or 1°C) Type N -58 to 2372°F (-50 to 1300°C) ±(0.05% + 2°F or 1°C) DC Measure Current 0 to 50mA, -25% to +230% ±(0.01% + 1 digit) Voltage 0 to 1999mV / 2 to 20V ±(0.01% + 1 digit) / auto range mV/Temp -10 to 60mV ±(0.01% + 1 digit) Type J -58 to 1832°F (-50 to 1000°C) ±(0.05% + 1.8°F or 1°C) Type K -58 to 2498°F (-50 to 1370°C) ±(0.05% + 1.8°F or 1°C) Type T -184 to 752°F (-120 to 400°C) ±(0.05% + 1.8°F or 1°C) Type E -58 to 1382°F (-50 to 750°C) ±(0.05% + 1.8°F or 1°C) Type C, R, S 32 to 3182°F (0 to 1750°C) ±(0.05% + 2°F or 1°C) Type N -58 to 2372°F (-50 to 1300°C) ±(0.05% + 2°F or 1°C) Loop Power 24V Meter Dims (LxWxH) 6.3" x 3.2" x 1.7" (159 x 80 x 44mm) Meter Wt 8.4oz (236g) - not including battery weight Specifications subject to change without notice. Copyright © 2012-2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. www.extech.com