English Datasheet

PRODUCT DATASHEET
PRC30 Multifunction
Process Calibrator
Precision source and measure for thermocouples
(8-Types), mA, mV, and V devices
Applications include:
• Lab and Field Calibration and Verification Operations
of Sensors, Thermocouple Probes, Controllers, Panel
meters & Testing tools.
• Temperature Control Process Troubleshooting
• Process devices calibration and simulation:
Transducers, Transmitters, Indicators, Controllers,
and Recorders
• Field test and service
• Bench research and development
Features
•
Palm-sized double molded housing and
large dot-matrix backlit LCD
•
Measures DC process signals
•
High accuracy calibration function simulates precision
thermocouple outputs for use in calibrating thermometers,
transmitters, controllers or recorders
•
Up to five user adjustable calibration presets
•
Displays output in terms of millivolts or temperature
based on thermocouple tables
•
24V Loop Power
•
Zero adjustment, auto zero when power on
and change mode
•
Standard banana I/O ports and mini thermocouple inputs
•
Large battery bank for extended work cycle
•
External power adapter for continuous work cycle
Complete with test leads, alligator clips, Thermocouple
calibration cable with subminiature connector, universal
calibration cable with subminiature terminal, 100V-240V
AC Universal Adaptor with 4 plugs, six 1.5V AA batteries,
and hard carrying case
Ordering
PRC30 .................Multifunction Process Calibrator
PRC30-NIST ........PRC30 with Certificate of Calibration Traceable to NIST
Specifications subject to change without notice. Copyright © 2012-2014 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form.
Rev. 4/2/14
www.extech.com
Specifications
Range
Basic Accuracy
Current
0 to 24mA, -25% to +125%
±(0.01% + 1 digit)
Max. Load
1000Ω @ 24mA
DC Source
Voltage
0 to 2000mV, 0 to 20V
±(0.01% + 1 digit)
mV/Temp
-5 to 55mV
±(0.01% + 1 digit)
Type J
-58 to 1832°F (-50 to 1000°C)
±(0.05% + 2°F or 1°C)
Type K
-58 to 2498°F (-50 to 1370°C)
±(0.05% + 2°F or 1°C)
Type T
-184 to 752°F (-120 to 400°C)
±(0.05% + 2°F or 1°C)
Type E
-58 to 1382°F (-50 to 750°C)
±(0.05% + 2°F or 1°C)
Type C, R, S
32 to 3182°F (0 to 1750°C)
±(0.05% + 2°F or 1°C)
Type N
-58 to 2372°F (-50 to 1300°C)
±(0.05% + 2°F or 1°C)
DC Measure
Current
0 to 50mA, -25% to +230%
±(0.01% + 1 digit)
Voltage
0 to 1999mV / 2 to 20V
±(0.01% + 1 digit) / auto range
mV/Temp
-10 to 60mV
±(0.01% + 1 digit)
Type J
-58 to 1832°F (-50 to 1000°C)
±(0.05% + 1.8°F or 1°C)
Type K
-58 to 2498°F (-50 to 1370°C)
±(0.05% + 1.8°F or 1°C)
Type T
-184 to 752°F (-120 to 400°C)
±(0.05% + 1.8°F or 1°C)
Type E
-58 to 1382°F (-50 to 750°C)
±(0.05% + 1.8°F or 1°C)
Type C, R, S
32 to 3182°F (0 to 1750°C)
±(0.05% + 2°F or 1°C)
Type N
-58 to 2372°F (-50 to 1300°C)
±(0.05% + 2°F or 1°C)
Loop Power
24V
Meter Dims (LxWxH)
6.3" x 3.2" x 1.7" (159 x 80 x 44mm)
Meter Wt
8.4oz (236g) - not including battery weight