Download Datasheet ABB-STAL Condensing turbine (PDF).

Energy
Data Record for Used Industrial Steam Turbines / Turbosets
Turbine
Original Equipment Manufacturer (OEM):
ABB-STAL
Turbine model: VAX LT10
Machine No.:
Year of manufacture: 1998
Design output (MW)
[at best turbine efficiency]:
Maximum output (MW): 5640kW
Steam consumption at design output (kg/kWh):
1)
_
Steam consumption at max. output (kg/kWh):
Max. main steam temperature (°C) : 148°C
Main steam temperature (°C)1): 145°C
Main steam pressure (bar g)1): 4,2 Bar(a), max4,5 Bar(a)
Main steam flow (t/h)1): 36t/h
Exhaust steam temperature (°C)1): 30°C
Exhaust steam flow (t/h)1):
Exhaust steam pressure (bar): 0,023 Bar(a)
Extraction pressure (bar g)2):
Extraction flow (t/h)2):
Speed (rpm): 5050rpm
Allowable frequency range (Hz): 50Hz
Direction of rotation:
Exhaust steam nozzle (downward, upward, right, left or axial):
Non-drive end of turbine (HP/LP end):
Package (yes/no), if yes, please state configuration (turbine, gear unit, generator, compressor): Yes; Turbine,
Gear unit, Generator and condensor
In case of package, is integral lube oil system provided? (yes/no): Yes
or extract from Operating Manual
Load points
1
2
3
Main steam parameters
Main steam flow (t/h)
Extraction pressure (bar)
Extraction flow (t/h)
Exh. steam pressure (bar)
Exh. steam temp. (°C)1)
Terminal output (kW)
Turbine condition
Last minor overhaul:
Last major overhaul: 2010
Operating hours: *56000h
Date of turbine shutdown and preservation details: 2012 it was shut down. A dryer is installed.
Expected to be available as from: August 27, 2013
1) in accordance with turbine design
2) where applicable
Siemens AG
Energy Sector; Management: Michael Süss
Energy Service Division; Management: Randy Zwirn
Oil & Gas and Industrial Applications Services; Management: Willibald Meixner
Frankenstr. 70-80
90461 Nuremberg
Germany
Phone: +49 (911) 4130 0
Fax: +49 (911) 4130 440
Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Gerhard Cromme; Managing Board: Peter Löscher, Chairman, President and Chief Executive
Officer; Roland Busch, Brigitte Ederer, Klaus Helmrich, Joe Kaeser, Barbara Kux, Hermann Requardt, Siegfried Russwurm, Peter Y. Solmssen, Michael Süss
Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin Charlottenburg, HRB 12300; Munich, HRB 6684
WEEE Reg. No. DE 23691322
SCF 04/2011 V08.12
Page 1 of 3
Energy
Are spare parts available? If yes, which ones?
Some spare parts availible
Turbine control and protection system
Original Equipment Manufacturer (OEM): ABB
Hydraulic or electronic: Electronic
Overspeed protection system (hydraulic [bolt]/electronic): Yes, Turloop
Axial shaft position monitoring system (hydraulic [nozzle]/electronic): Yes, Bently&Nevada
_
Vibration monitoring system (yes/no): Yes, , Bently&Nevada
Actuators for control and stop valve(s) (HP/LP hydraulic system): HP hydraulic system
Magnet wheel installed on turbine shaft (yes/no, if yes, please state number of teeth):
Electrohydraulic converter installed (yes/no): Yes
Condenser:
Original Equipment Manufacturer (OEM):
Condenser model:
Condensing capacity (t/h):
Condenser pressure (bar):
3
Cooling water flow (m /h):
Cooling water velocity (m/s):
Cooling water inlet temperature (°C):
Thermal capacity (MW):
Supply lines:
Complete operating documentation available (yes/no):
Complete machine file available (yes/no):
Is the driven machine also available for purchase (yes/no):
SCF 04/2011 V08.12
Page 2 of 3
Energy
_
Driven generator
Machine No.:
Original Equipment Manufacturer (OEM): ABB
Rating (MVA): 6,15 MVA
Generator type (cooling system):
Generator model: AMS 800 SA
Voltage (kV): 11,0kV
Frequency (Hz): 50Hz
Current (A): 323 A
Power factor (cos phi): 0,80
Speed (rpm): 1500 rpm
Design: e.g. B3
Insulation class: F
Type of enclosure:
Cooling water inlet temperature (°C): Max 30°C
Cooling water flow (m3/h): 29,0 m3/h
Compound excitation (… V - … A):
Generator condition
Last minor overhaul:
Last major overhaul: 2009
Operating hours:56000h
Date of turbine shutdown and preservation details:
Expected to be available as from:
Gear unit:
Original Equipment Manufacturer (OEM): FlenderGraffenstaden
Rating (HP)
Gear unit model: TX4,5/3
Speed (rpm):5050/1500 rpm
Complete scope of supply available for purchase:
·
Note: Operating hours estimated to 56000h. Since start 1998 it has produced 155 937 MWh, around 800
starts
·
·
·
·
·
·
·
·
Size (footprint) / dimensions:
Please provide photographs of the turboset / turbine separately in electronic form.
SCF 04/2011 V08.12
Page 3 of 3