SPECIFICATIONS
Part
Number
Vin
Nom.
(VDC)
Vout
(VDC)
Iout
Max.
(mA)
Iout
Min.
(mA)
Effi.
Typ.
(%)
CTDD2408MF-0505-SU6K-2
CTDD2408MF-0512-SU6K-2*
CTDD2408MF-0515-SU6K-2
5
5
5
4.5-5.5
4.5-5.5
4.5-5.5
5
12
15
400
167
133
40
17
13
76
79
78
CTDD2408MF-1205-SU6K-2*
CTDD2408MF-1212-SU6K-2*
CTDD2408MF-1215-SU6K-2
12
12
12
10.8-13.2
10.8-13.2
10.8-13.2
5
12
15
400
167
133
40
17
13
76
80
79
CTDD2408MF-2405-SU6K-2*
CTDD2408MF-2412-SU6K-2*
CTDD2408MF-2415-SU6K-2*
24
24
24
21.6-26.4
21.6-26.4
21.6-26.4
5
12
15
400
167
133
40
17
13
77
80
78
Input Range
(VDC)
*Designing.
RoHS
Compliant
ISOLATION SPECIFICATIONS
Item
Test Condition
MIN
Isolation Voltage
Tested for 1 min. & 1mA Max. 6000
Isolation Resistance
Test at 500VDC
TYP
MAX
Units
VDC
1000
MΩ
Isolation Capacitance
10
pF
OUTPUT SPECIFICATIONS
Item
Test Condition
MIN
Output Power
TECHNOLOGIES
W
±1.2
%
Load regulation
10% to 100% load(5V output)
12.8
15
%
10% to 100% load(12V output)
6.8
15
%
10% to 100% load(15V output)
6.3
15
%
Output voltage accuracy
See tolerance envelope graph
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
150
Switching frequency
Full load, nominal input
50
0.03
%/°C
200
mVp-p
KHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter. Section, application notes.
TYPICAL CHARACTERISTICS
Tolerance Derating Graph
Tolerance Envelope Graph
Output Voltage(%)
+10%
-5%
Nominal
Voltage
Typic
a
l Load
Line
+2.5%
-2.5%
-7.5%
10%
50%
100%
Output Current(%)
Manufacturer of Passive Components
800-684-5322 Inside US
949-453-1811 Outside US
Copyright © 2009 by CT Magnetics, DBA Central Technologies. All rights reserved.
CT Magnetics reserves the right to make improvements or change specifications without notice
Output Power (%)
120
02.18.09
CENTRAL
Units
2
For Vin change of 1%
CHARACTERISTICS
Short Circuit Protection: Continuous, automatic recovery
Temperature Rise at Full Load: 25°C Max. 15°C Typ.
Cooling: Free air convection
Operating Temperature Range: -40°C to +85°C
Storage Temperature Range: -55°C to +125°C
Lead Temperature: 260°C Max. (1.5mm from case for 10
seconds)
Storage Humidity Range: 95% Max.
Case Material: Plastic (UL94-V0)
MTBF: 3,500,000 hours
Weight: 3.8g Typ.
Miscellaneous: RoHS Compliant.
MAX
Line regulation
FEATURES
Efficiency: To 80%
Temperature Range: -40°C to +85°C
Isolation: 6KVDC
Package: UL94-V0
Miscellaneous: No heat sink required. No external component
required. Industry standard pinout. SMD Package. Continuous
short circuit protection. Internal SMD Construction.
Samples available.
TYP
0.2
100
80
60
Safe Operating Area
40
20
0
-40
0
85 105 120
40
Ambient Temperature (°C)
DC/DC Converters
ctparts.com
CTDD2408MF-SU6K-2 Series
Fixed Input Isolated & Unregulated
2W Output, Single Output
OUTLINE DIMENSIONS & PIN CONNECTIONS
8.00
(0.315)
7.50
(0.295)
23.86 (0.940)
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm(0.1inch)
(Side View)
13.70
(0.540)
18.50(0.728)
3.04
(0.120)
2.54
(0.100)
16
16
10 9
1
7 8
2.00
(0.079)
10 9
(Top View)
1
78
1.00
(0.039)
15.24(0.600)
FOOTPRINT DETAILS
Pin
Function
1
GND
7
NC
8
NC
+Vo
9
10
-Vo
16
Vin
NC:No Connection
0.25
(0.010)
A
13.10
(0.516)
18.50(0.728)
0.50
(0.020)
A
5.0MAX
Note:
Unit: mm(inch)
Pin section: 0.60*0.25mm(0.010inch)
Pin tolerance: ±0.10mm(±0.004inch)
General tolerance: ±0.25mm(±0.010inch)
1.35
(0.053)
02.18.09
CENTRAL
TECHNOLOGIES
Manufacturer of Passive Components
800-684-5322 Inside US
949-453-1811 Outside US
Copyright © 2009 by CT Magnetics, DBA Central Technologies. All rights reserved.
CT Magnetics reserves the right to make improvements or change specifications without notice
DC/DC Converters
ctparts.com
CTDD2408MF-SU6K-2 Series
Fixed Input Isolated & Unregulated
2W Output, Single Output
APPLICATION NOTES
L On Output Load
Requirement
To ensure this module can operate efficiently and reliably, a minimum load is
specified for this kind of DC/DC converter in addition to a maximum load (namely full
Output Voltage Regulation and Over-voltage
Protection Circuit
The simplest device for output voltage regulation,
load). During operation, make sure the specified range of input voltage is not exceeded,
over-voltage and over-current protection is a linear
the minimum output load is not less than 10% of the full load, and that this product
voltage regulator with overheat protection that is
should never be operated under no load! If the actual output power is very small,
connected to the input or output end in series (Figure
please connect a resistor with proper resistance at the output end in parallel to increase
2).
the load, or use our company's products with a lower rated output power.
Vin
+Vout
REG
DC DC
GND
0V
REG
Vin
Recommended testing and application circuit
If you want to further decrease the input/output
GND
ripple, an "LC" filtering network may be connected to
+Vout
DC DC
0V
(Figure 2)
the input and output ends of the DC/DC converter, see
Overload Protection
Under norm al operating conditions, the output
(Figure 1).
L
L
+Vo
Vin
DC DC
Cin
circuit of these products has no protection against
overload. The simplest method is to connect a
Cout
G ND
self-recovery fuse in series at the input end or add a
0V
circuit breaker to the circuit.
(Figure 1)
It should also be noted that the inductance and the
No parallel connection or plug and play.
frequency of the "LC" filtering network should be
staggered with the DC/DC frequency to avoid mutual
Note:
1. All specifications measured at Ta=25°C, humidity<75%,
nominal input voltage and rated output load unless
otherwise specified.
2. Only typical models listed, other models may be different,
please contact our technical person for more details.
3. Operation under minimum load will not damage the
converter; However, they may not meet all specification
listed.
interference. However, the capacitance of the output
filter capacitor must be proper. If the capacitance is
too big, a startup problem might arise. For every
channel of output, provided the safe and reliable
operation is ensured, the recommended capacitance
of its filter capacitor sees (Table 1).
EXTERNAL CAPACITOR TABLE (Table 1)
Vin
(VDC)
5
Cin
(uF)
4.7
Single Vout
(VDC)
5
Cout
(uF)
10
12
2.2
12
2.2
24
1
15
1
It's not recommend to connect any external capacitor in the
application field with less than 0.5 watt output.
02.18.09
CENTRAL
TECHNOLOGIES
Manufacturer of Passive Components
800-684-5322 Inside US
949-453-1811 Outside US
Copyright © 2009 by CT Magnetics, DBA Central Technologies. All rights reserved.
CT Magnetics reserves the right to make improvements or change specifications without notice