MORNSUN D050303M-1W

D_M-1W Series
1W,FIXED INPUT,1000V ISOLATED & UNREGULATED
TWIN OUTPUT DC-DC CONVERTER
multi-country patent protection
FEATURES
● Small footprint
● SIP package
● Temperature range: -40°C~+85°C
● 1KVDC isolation
● No Heat sink required
● No external component required
● Internal SMD Construction
● Industry standard pinout
● RoHS Compliance
RoHS
PRODUCT PROGRAM
Input
Part
Number
D030505M-1W
Output
Voltage (VDC)
Nominal
Range
3.3
2.97-3.63
D050303M-1W
5
Voltage
(VDC)
4.5-5.5
D050505M-1W
Efficiency
(%, Typ)
Current (mA)
Max.
Min.
5
100
10
70
3.3
100
10
62
5
100
10
71
APPLICATIONS
The D_M-1W Series are specially designed
for applications where a group of polar power
supplies are isolated from the input power
supply in a distributed power supply system on
a circuit board.
COMMON SPECIFICATIONS
These products apply to:
1) Where the voltage of the input power supply
is fixed (voltage variation ≤ ±10%);
2) Where isolation is necessary between input
and output (isolation voltage ≤1000VDC);
3) Where the regulation of the output voltage
and
the
output
ripple noise
Item
Test Conditions
Min.
Typ.
Storage humidity range
are not
demanding.
Operating temperature
Storage temperature
Lead temperature
Short circuit protection*
frequency analog circuits, and IGBT power
Cooling
device driving circuits.
Case material
-55
125
1.5mm from case for 10 seconds
MORNSUN Science& Technology co.,Ltd.
Address: 2th floor 6th building, Hangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
Fax: 86-20-38601272
http://www.mornsun-power.com
℃
300
15
25
1
S
Free air convection
Plastic(UL94-V0)
1.4
Weight
Rated Power
Product Series
The 2nd Output Voltage
The 1st Output Voltage
Input Voltage
Package Style
%
85
MTBF
MODEL SELECTION
D050505M-1W
Units
95
-40
Temp. rise at full load
Such as: purely digital circuits, ordinary low
Max.
g
3500
K hours
*Supply voltage must be discontinued at the end of short circuit duration.
ISOLATION SPECIFICATIONS
Item
Test Conditions
Isolation voltage (Vin/Vout)
Tested for 1 minute and 1mA max 1000
Min.
Isolation voltage (Vo1/Vo2)
Tested for 1 minute and 1mA max 1000
Isolation resistance (Vin/Vout)
Test at 500VDC
1000
Isolation resistance (Vo1/Vo2)
Test at 500VDC
1000
Typ.
Units
VDC
MΩ
Isolation capacitance(Vin/Vout)
30
Isolation capacitance(Vo1/Vo2)
30
The copyright and authority for the interpretation of the products are reserved by Mornsun
Max.
Specifications subject to change without notice.
D_M-1W
A/0-2009
Page 1 of 2
pF
OUTPUT SPECIFICATIONS
Item
Test Conditions
Output power
Line regulation
Load regulation
TYPICAL CHARACTERISTICS
Min.
Typ.
Max.
Units
1
W
0.1
±1.5
For Vin change of 1%
10% to 100% load (3.3V output)
10% to 100% load(5V output)
Output voltage accuracy
15
20
12.8
15
%
See tolerance envelope graph
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
75
Switching frequency
Full load, nominal input
130
±0.03
%/℃
100
mVp-p
KHz
*Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of
Power Converter section, application notes.
Operating Temp.(oC)
APPLICATION NOTE
RECOMMENDED CIRCUIT
Requirement on output load
To ensure this module can operate efficiently and reliably, During operation, the minimum
output load is not less than 10% of the full load, and that this product should never be
operated under no load! If the actual output power is very small, please connect a resistor
L
+Vo1
L
C
Vin
DC DC
C
0V1
+Vo2
L
GND
C
0V2
with proper resistance at the output end in parallel to increase the load, or use our company’s
products with a lower rated output power.
Recommended circuit
If you want to further decrease the input/output ripple, an “LC” filtering network may be
(Figure 1)
+Vo1
Vin
REG
0V1
connected to the input and output ends of the DC/DC converter, see (Figure 1).
It should also be noted that the inductance and the frequency of the “LC” filtering network
DC
DC
+Vo2
GND
0V2
should be staggered with the DC/DC frequency to avoid mutual interference. However, the
capacitance of the output filter capacitor must be proper. If the capacitance is too big, a
startup problem might arise. For every channel of output, provided the safe and reliable
operation is ensured, the recommended capacitance of its filter capacitor sees (Table 1).
+Vo1
REG
Vin
0V1
DC
DC
+Vo2
REG
GND
0V2
(Figure 2)
Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection
is a linear voltage regulator with overheat protection that is connected to the input or output
end in series (Figure 2).
Overload Protection
Under normal operating conditions, the output circuit of these products has no protection
EXTERNAL CAPACITOR TABLE (TABLE 1)
Vin(VDC)
Cin(uF)
Cout(uF)
Vout(VDC)
3.3/5
4.7
3.3/5
4.7
It’s not recommended to connect any external
capacitor in the application field with less than 0.5
watt output.
against overload. The simplest method is to connect a self-recovery fuse in series at the
input end or add a circuit breaker to the circuit.
No parallel connection or plug and play
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
D_M-1W
A/0-2009
Page 2 of 2
OUTLINE DIMENSIONS & PIN CONNECTIONS
RECOMMENDED FOOTPRINT
0.30 [0.012]
MECHANICAL DIMENSIONS
16.50 [0.650]
(Bottom View)
2
3
4
5
6
2.54 [0.100]
12.70 [0.500]
1
2
3
4
5
6
2.54 [0.100]
0.90 [0.035]
1
0.90 [0.035]
6.00 [0.236]
∅1.00 [∅ 0.039]
12.70 [0.500]
2.54 [0.100]
7.50 [0.295]
(Side View)
0.50 [0.020]
TUBE OUTLINE DIMENSIONS
4.10 [0.161]
9.40 [0.370]
0.50 [0.020]
Note:
Uni t:m m [i nch]
P i n section tolerances: ±0.10m m[0.004i nch]
General tol erances: ±0.25m m [ ±0.010i nch]
12.20 [0.480]
16.70 [0.657]
F OOTPRINT DETAILS
Function
Pi n
Vi n
1
GND
2
0V1
3
Vo1
4
0V2
5
Vo2
6
0.60 [0.024]
4.70 [0.185]
Note:
Unit :mm[inch]
General tolerances: ±0.50mm[±0.020inch]
L=530mm[20.866inch] Tube Quantity: 30pcs
L=220mm[8.661inch] Tube Quantity: 11pcs
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
3. In this datasheet, all the test methods of indications are based on corporate standards.