NEC EXPRESS5800/R320d-M4 Configuration Guide Windows Server 2008 R2 model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC EXPRESS5800 server. March 2014 Revision 1.0 NEC Corporation CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 5 Front and Rear Views ........................................................................................................................... 5 Dimensions (mm) .................................................................................................................................. 7 CONFIGURATION DIAGRAM ......................................................................................... 8 SERVER CONFIGURATION ........................................................................................... 9 1 2 3 4 5 6 7 8 Base Models ................................................................................................................................... 9 2nd Processor ................................................................................................................................ 9 Memory ........................................................................................................................................... 9 Internal Hard Disk Drives ............................................................................................................ 11 Optical Drive ................................................................................................................................. 11 PCI Card ........................................................................................................................................ 11 6.1 LAN Controller ..................................................................................................................... 11 6.2 Fibre Channel / SAS Controller ........................................................................................... 12 Other Add-in Components .......................................................................................................... 12 7.1 Input Devices ....................................................................................................................... 12 Add-on Components ................................................................................................................... 13 8.1 17-inch LCD Console Drawer .............................................................................................. 13 8.2 KVM Switch ......................................................................................................................... 13 8.3 Flash FDD............................................................................................................................ 13 8.4 Operating System ................................................................................................................ 14 TM 8.5 Active Upgrade ................................................................................................................. 14 8.6 Tower Conversion Kit ........................................................................................................... 14 8.7 External Tape Drives ........................................................................................................... 14 REFERENCES............................................................................................................... 17 Server Management ............................................................................................................................ 17 Supported PCI Cards and Installable Slots ...................................................................................... 18 Notes for using Hyper-V ..................................................................................................................... 19 Copyright Notice and Liability Disclaimer ........................................................................................ 20 REVISION HISTORY ..................................................................................................... 21 NEC Corporation Revision 1.0, March 2014 2 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Technical Specification Key Features TM Fault tolerant technology based on GeminiArchitecture Full manageability by integrated EXPRESSSCOPE Engine 3 High performance with the latest Intel® Xeon® processor E5-2600 v2 product family Up to 256GB of high speed DDR3L-1600 memory Specification Model R320d-M4 Part Number Processor N8800-185F Type Intel® Xeon® processor E5-2670 v2 Clock speed 2.50 GHz Logical Number of Processors Cache 1 or 2 Cores and Threads 10C / 20T TM Chipset Memory Internal Storage Expansion Slots [free] Video 25 MB Intel® C602 Chipset with GeminiEngine Type DDR3L-1600 Registered DIMM with ECC Memory Clock 1600MHz Logical Standard Capacity Logical Maximum Capacity Memory protection 0GB Standard Capacity 0GB Maximum Logical Capacity Disk Controller 9.6 TB (8 x 1.2TB) RAID SAS : RAID 1 (Standard) Hot Plug Supported Optical Disk Drive DVD Super Multi drive Optical Drive Bays [free] Logical Disk Drive Bays [free] Standard 1 [0] Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color Supported 800 x 600 / 16.7M, 1024 x 768 / 16.7M, 1280 x 1024 / 65K 256GB (16 x 16 GB) ECC, x4 SDDC SAS: 6Gb/s (Standard) 1 8 [8] Total: 4 slots available 2 Low-profile PCIe x4 Gen 2 (x8 connector) 2 Full-height PCIe x8 Gen 2 (x8 connector) Interfaces 1 VGA (15-pin mini D-sub, 1 rear per system) 4 USB2.0 (1 front, 3 rear per system) 4 10GBASE-T LAN connector (RJ-45, 2 rear per module) 4 1000BASE-T LAN connector (RJ-45, 2 rear per module) 2 Management LAN connector (RJ-45, 1 rear per module) Server Management EXPRESSSCOPE Engine 3 Power Supply 2 x 800 Watt (1 per module, 80 PLUS® Platinum certified) 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz NEC Corporation Revision 1.0, March 2014 3 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Model Power (Max. Config, Consumption Operating) Dimensions (W x D x H ) 1 R320d-M4 1,300 VA / 1,290 Watt 483.0 x 736.0 x 178 mm / 19.0 x 29.0 x 7.0 in (4U) Weight (Minimum / Maximum) 45 kg / 51 kg, 99.21 lbs. / 112.44 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, BSMI, CCC, UL, CB, RoHS Operating Systems Microsoft Windows Server® 2008 R2 Enterprise SP1 Writing software is not provided for this DVD drive. NEC Corporation Revision 1.0, March 2014 4 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model External Views Front and Rear Views Front View B A C D E F G H I J A N B K L M P Q R O S T U Legend A. Drive Bays L. CPU Fault LED B. UID Button M. Memory Fault LED C. DVD Super Multi Drive N. Module Power LED D. System Power LED O. SAFE TO PULL LED E. System Status LED P. PRIMARY LED F. System FT LED Q. IO Module Fault LED G. UID LED R. Fan Fault LED H. USB Connector S. PSU Fault LED I. Pull-out Tab T. DC Power Fault LED J. Power Button U. Temperature Fault LED K. Module ID LED NEC Corporation Revision 1.0, March 2014 5 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Rear View B C D D E E A F H I J G Legend A. 1 USB Connectors F. AC Inlet B. Management LAN Connector G. PCI Slots (Low-Profile) C. Module ID LED H. PCI Slots (Full-Height) D. Data LAN Connectors (10GBase-T) I. Serial Port Connector E. Data LAN Connectors (1000Base-T) J. VGA Connector 1 For service personnel only. NEC Corporation Revision 1.0, March 2014 6 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Dimensions (mm) Rack mount 748.5 736 177 448 485 688.5 Tower Conversion (Optional) 220 804 592 327 NEC Corporation Revision 1.0, March 2014 7 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Configuration Diagram Server CHASSIS REAR CHASSIS FRONT HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay Backplane CPU/IO Module HDD Bay Optical Drive Bay CPU/IO Module PCIe 2.0 x8 (x8 socket) FH DIMM #8 DIMM #7 DIMM #6 DIMM #5 DIMM #9 DIMM #10 DIMM #11 DIMM #12 HDD Bay HDD Bay PCI Riser Cooling Fan #1 - #4 Processor CHASSIS FRONT HDD Bay #1 #2 #3 #4 Drive Cage HDD Bay DIMM DIMM DIMM DIMM HDD Bay CHASSIS REAR HDD Bay CPU/IO module #0 : Power Supply #16 #15 #14 #13 DIMM DIMM DIMM DIMM #1 #2 #3 #4 HDD Bay DIMM DIMM DIMM DIMM HDD Bay Processor PCIe 2.0 x4 (x8 socket) LP PCIe 2.0 x4 (x8 socket) LP HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay Drive Cage HDD Bay PCIe 2.0 x8 (x8 socket) FH DIMM #8 DIMM #7 DIMM #6 DIMM #5 DIMM #9 DIMM #10 DIMM #11 DIMM #12 HDD Bay PCI Riser Cooling Fan #1 - #4 Processor HDD Bay CPU/IO module #1 : Processor PCIe 2.0 x4 (x8 socket) LP PCIe 2.0 x4 (x8 socket) LP Power Supply Legend: NEC Corporation DIMM DIMM DIMM DIMM #16 #15 #14 #13 Minimum required components Revision 1.0, March 2014 Standard components 8 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Server Configuration 1 Base Models Product Name / Description Part Number EXPRESS5800/R320d-M4 no RAM, no 2.5-inch HDD Including: Intel Xeon Processor E5-2670 v2, 1 x DVD Super Multi, EXPRESSBUILDER DVD N8800-185F 2 2nd Processor Available logical sockets: 1 Product Name / Description Part Number Intel® Xeon® Processor E5-2670 v2 2nd Processor Kit : 2.50 GHz / 10C-20T / 25 MB, 2 processors included N8801-047 3 Memory Available logical slots: 8 per processor Product Name / Description Part Number 4GB DDR3-1600 REG Memory Kit : 2 x 1 x 4GB DIMM included N8802-060 32GB DDR3-1600 REG Memory Kit : 2 x 4 x 8GB DIMM included N8802-061 64GB DDR3-1600 REG Memory Kit : 2 x 4 x 16GB DIMM included N8802-062 NOTE: Minimum one memory kit must be installed. NEC Corporation Revision 1.0, March 2014 9 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Memory Configuration Guideline See the table below for the number of memory kits required in accordance with logical main memory size and number of logical processors. Memory configurations which are not listed below are not supported in the system. Number of Logical Processors 1 Logical Main Memory Size 4GB 2 1 4GB 32GB 64GB 1 - - 8GB 2 - - 12GB 3 - - 16GB 4 - - 20GB 5 - - 24GB 6 - - 28GB 7 - - 32GB 8 - - - 1 - 48GB 4 1 - 64GB - 2 - 64GB - - 1 96GB - 1 1 128GB - - 2 1 - - 2 - - 4GB 1 8GB 1 12GB 1 Number of Memory Kits Required 1 3 - - 16GB 4 - - 24GB 6 - - 32GB 8 - - 40GB 10 - - 48GB 12 - - 56GB 14 - - 64GB 16 - - - 2 - 96GB 8 2 - 128GB - 4 - - - 2 192GB - 2 2 256GB - - 4 Interleave is not supported. NEC Corporation Revision 1.0, March 2014 10 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model 4 Internal Hard Disk Drives Available bays: 8 Product Name / Description Part Number 600GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 600GB N8850-047 900GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 900GB N8850-048 1.2TB 10K Hot Plug 2.5-inch SAS HDD : 1 x 1.2TB N8850-051 146.5GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 146.5GB N8850-049 300GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 300GB N8850-050 NOTE: Hard drives must be installed in identical pairs to configure RAID 1. Required System Disk Capacity See the table below for minimum required system disk capacity to store whole memory dump data. It is recommended to install hard drives providing the minimum required system disk capacity to reduce the time to resynchronize after a hard drive replacement. Memory Size Required System Disk Capacity Up to 28GB 32GB to 64GB 96GB to 192GB 256GB 146.5GB 300GB 600GB 900GB 5 Optical Drive Available bays: 1 Product Name / Description Part Number Internal DVD Super Multi Drive : 1 x DVD Super Multi drive, not including writing software (Standard) 6 PCI Card 6.1 LAN Controller Category Product Name / Description Part Number LAN Controller 1000BASE-T 2ch board kit : 2 x GbE NIC Intel® Gigabit ET Dual Port Server Adapter 10GBASE-T 1ch Adapter Kit : 2 x 10GbE NIC Intel® X540-T1 NOTE: - Up to one controller per module - Installation in full height slots only supported on R320d-M4 - FCoE functionality is not supported N8804-009 N8804-011 NOTE: For iSCSI (data) connection, only 1000BASE-T ports (Including standard LAN ports) are supported. NEC Corporation Revision 1.0, March 2014 11 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model 6.2 Fibre Channel / SAS Controller Category Product Name / Description Part Number Fibre Channel Controller Fibre Channel board kit (8Gbps) : 2 x FC Controller QLogic QLE2560 8Gbps Fibre Channel Adapters NOTE: Installation in full height slots only supported on R320d-M4 N8803-038 SAS Controller SAS Controller : 1 x SAS Controller LSI SAS9212-4i4e Host Bus Adapter NOTE: Up to one controller per module N8803-039 NOTE: For supported NEC Storage products to connect with N8803-038, contact your sales representative or refer to the NEC Storage WEB site. (http://www.nec.com/global/prod/storage/) 7 Other Add-in Components 7.1 Input Devices Category Product Name / Description Part Number Keyboard USB Keyboard N8870-002AF Mouse USB Optical Wheel Mouse N8870-012 Cable USB cable : 1.5m USB extension cable K410-177(1A) NEC Corporation Revision 1.0, March 2014 12 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model 8 Add-on Components 8.1 17-inch LCD Console Drawer Category Drawer w/ KVM Switch Product Name / Description Part Number Drawer 17inch LCD Console Unit (1U/8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height N8143-77F Cable Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2m 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1port) K410-118(1A) Drawer Drawer w/o KVM Switch Keypad K410-118(03) K410-118(05) N8143-76F N8143-84F N8143-85 N8143-87 8.2 KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch N8191-12F Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 K410-118(1A) Cable KVM Cascading K410-118(03) K410-118(05) K410-119(1A) 8.3 Flash FDD Order the Flash FDD if you need to prepare an alternative for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-86 NEC Corporation Revision 1.0, March 2014 13 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model 8.4 Operating System Product Name / Description Part Number Microsoft Windows Server® 2008 R2 Enterprise (1-2 Processor, 25CAL Version): English UL0999-436EN Chinese Traditional UL0999-436CT Chinese Simplified UL0999-436CS Korean UL0999-436KR NOTE: Service Pack1 is not included in these products. Service Pack1 needs to be applied separately. 8.5 Active UpgradeTM Product Name / Description Part Number Active Upgrade for ft UL1535-001E 8.6 Tower Conversion Kit Product Name / Description Part Number Tower Conversion Kit 23 inch height pedestal with front bezel N8843-004 8.7 External Tape Drives 8.7.1 Tape Drive Selection Refer to the section in accordance with your type of tape drives. LTO NEC Corporation LTO3 SAS Refer to 8.7.2 LTO4 SAS Refer to8.7.2 LTO5 SAS Refer to 8.7.2 LTO6 SAS Refer to 8.7.2 Revision 1.0, March 2014 14 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model 8.7.2 LTO / SAS Category Product Name / Description Part Number Controller Required N8803-039 External Cable Required SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8, LP/FH NOTE: Up to one controller per module External SAS cable 2 m, for Tape Drive Enclosure connection Tape Enclosure Required 2U Tape Drive Enclosure 4 x 5-inch media bays, two internal SAS cables included N8141-59F Power Module Recommended Power Supply 1 x non-hot plug power supply unit for redundant configuration N8181-54F Internal Cable Internal SAS cable 2 m, for 2U Tape Drive Enclosure internal connection NOTE: Required when three or more SAS connections (including other general purpose servers) to the N8141-59F K410-249(00) Drive 2 bays available Internal LTO (SAS) LTO3, Half height, Native capacity 400GB Internal LTO (SAS) LTO4, Half height, Native capacity 800GB Internal LTO (SAS) LTO5, Half height, Native capacity 1500GB Internal LTO (SAS) N8151-102 K410-191(02) N8151-90 N8151-103 N8151-106 LTO6, Half height, Native capacity 2.5 TB 8.7.3 Notes for Double Backup In a single backup configuration, in case a CPU/IO module or backup device fails, backup is not possible until the failed part is repaired or replaced. If this does not meet your system requirements, consider a double backup configuration. Refer to the following notes on double backup configuration. When configuring two sets of a SAS controller, a SAS cable and a backup device, two backup devices are recognized separately by the OS. When scheduling an automatic backup job, make a job for each backup device so that the other backup device can backup in case one device fails. With BrightStor ARCserve Backup, backup is not executed if you enter an asterisk (*) in the group box under the destination tab when defining a job. Be sure to create two backup jobs by correctly selecting the device group for the group box, and entering an asterisk (*) or the name of the media in the media box. NEC Corporation Revision 1.0, March 2014 15 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model 8.7.4 Supported Backup Software See the table below for the supported backup software on NEC EXPRESS5800/R320d. Tape drive Product Name / Description Backup software Part Number ARCserve Backup Exec ARCserve r16.5 Backup Exec 2012 WS2008R2 WS2008R2 Internal LTO (SAS) LTO3, Half height, Native capacity 400 GB N8151-102 *a1 *b1 Internal LTO (SAS) LTO4, Half height, Native capacity 800 GB N8151-90 *a1 *b1 N8151-103 *a1 *b1 N8151-106 *a1 *b1 Internal LTO (SAS) LTO5, Half height, Native capacity 1.5 TB Internal LTO (SAS) LTO6, Half height, Native capacity 2.5 TB *a1: Do not disable the tape driver on the device manager. *b1: Do not install the Symantec driver. Apply the driver which comes with the tape drive. NOTE: Disaster Recovery Option is not supported on the ft server system. It is not supported to backup from NEC Express5800/ft series to a backup device directly using NetBackup. However, NEC Express5800/ft series can be a backup-client machine of NetBackup. NEC Corporation Revision 1.0, March 2014 16 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Temperature/voltage/power/ fan /degeneration (memory/hard drive) Hardware event log collection Boot monitoring Booting, BIOS/POST stall, OS stall, shutdown Alerting HW error, Boot error and OS panic (by SNMP, E-Mail) Remote KVM POST/BIOS setup, DOS utility (via LAN) Panic screen, Boot screen Text-based screen (OS console) GUI-based screen (OS console) Remote control Remote reset/power on-off/ dump (via LAN) OS shutdown Remote media (CD/DVD/FD) Server Management Command Line Protocol (DMTF compliant) Remote control via Web browser (without dedicated app) Remote batch Scheduling (without UPS) Others Set automatic IP address via DNS/DHCP Remote wakeup Wake On LAN, Wake On Ring Centralized management Industry standard Monitoring and control of multiple servers IPMI 2.0 Hardware monitoring NEC Corporation Revision 1.0, March 2014 17 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Supported PCI Cards and Installable Slots Part Number Slots Notes Slot # : #1 #2 #3 #4 PCI Slot: x4 x4 X8 X8 Card height: LP LP FH FH Slot type: x8 x8 x8 x8 N8804-009 1000BASE-T 2ch board kit N8804-011 10GBASE-T 1ch board set - - N8803-038 N8803-039 1 Product Name Fibre Channel board kit SAS board 1 1 Max. 1 1 1 1 1 Max. 1 Not installable when using Tower Conversion Kit. NEC Corporation Revision 1.0, March 2014 18 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Notes for using Hyper-V Brief system interruption during synchronization process In the synchronization process of CPU modules, a memory copy is performed to duplex memory on both CPU modules. Most of the memory area can be copied without interrupting the system through the so-called brownout copy method, and just a small portion requires the system to stop. However, with Hyper-V, the system cannot use the brownout copy method. Therefore, the system does not respond for a longer period of time during the synchronization process of the CPU modules than without Hyper-V. See the table below for the reference values of interruption during re-synchronization of CPU/IO modules in a Hyper-V system. It is recommended that your system design take the interruption into account. Model / Memory Size 8GB 16GB 64GB 128GB 256GB R320d-E4 2 sec 3 sec 10 sec 18 sec 36 sec R320d-M4 2 sec 3 sec 8 sec 14 sec 27 sec About Guest OS Guest operating systems supported on NEC Express5800/ft series are the same as other general purpose servers. Refer to the Microsoft web site for Supported Guest Operating Systems on Hyper-V. Backup When using Hyper-V on a FT server, prepare a separate server for backup in the same way as for other general purpose servers with Hyper-V. For backup patterns, refer to each backup software company's web site. NEC ESMPRO Agent For monitoring guest operating systems, NEC ESMPRO Agent for Guest OS is required. Contact your sales representative for this software. Active Upgrade A team assigned to the virtual network by Hyper-V Virtual Network Manager cannot be used in Active Upgrade. To use Active Upgrade, at least one team that is not assigned to virtual network is required. NEC Corporation Revision 1.0, March 2014 19 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 1.0, March 2014 20 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-M4 / Windows Server 2008 R2 model Revision History Revision Date Description 1.0 2014.3.18 Initial release NEC Corporation Revision 1.0, March 2014 21