NEC EXPRESS5800/R320d-E4 Configuration Guide Windows Server model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC EXPRESS5800 server. April 2015 Revision 4.0 NEC Corporation CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 5 Front and Rear Views ........................................................................................................................... 5 Dimensions (mm) .................................................................................................................................. 7 CONFIGURATION DIAGRAM ......................................................................................... 8 SERVER CONFIGURATION ........................................................................................... 9 1 2 3 4 5 6 7 8 Base Models ................................................................................................................................... 9 2nd Processor ................................................................................................................................ 9 Memory ........................................................................................................................................... 9 Internal Hard Disk Drives ............................................................................................................ 11 Optical Drive ................................................................................................................................. 12 PCI Card ........................................................................................................................................ 12 6.1 LAN Controller ..................................................................................................................... 12 6.2 Fibre Channel / SAS Controller ........................................................................................... 12 Other Add-in Components .......................................................................................................... 12 7.1 Input Devices ....................................................................................................................... 12 Add-on Components ................................................................................................................... 13 8.1 17-inch LCD Console Drawer .............................................................................................. 13 8.2 KVM Switch ......................................................................................................................... 13 8.3 Flash FDD............................................................................................................................ 14 8.4 Operating System ................................................................................................................ 14 TM 8.5 Active Upgrade ................................................................................................................. 14 8.6 Tower Conversion Kit ........................................................................................................... 14 8.7 External Tape Drives ........................................................................................................... 15 REFERENCES............................................................................................................... 18 Server Management ............................................................................................................................ 18 Supported PCI Cards and Installable Slots ...................................................................................... 19 Notes for using Hyper-V ..................................................................................................................... 20 Copyright Notice and Liability Disclaimer ........................................................................................ 22 REVISION HISTORY ..................................................................................................... 23 NEC Corporation Revision 4.0, April 2015 2 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Technical Specification Key Features TM Fault tolerant technology based on GeminiArchitecture Full manageability by integrated EXPRESSSCOPE Engine 3 High performance with the latest Intel® Xeon® processor E5-2600 v2 product family Up to 256GB of high speed DDR3L-1600 memory Specification Model R320d-E4 Part Number Processor N8800-184F Type Intel® Xeon® processor E5-2620 v2 Clock speed 2.10 GHz Logical Number of Processors Cache 1 or 2 Cores and Threads 6C / 12T TM Chipset Memory Internal Storage Expansion Slots [free] Video 15 MB Intel® C602 Chipset with GeminiEngine Type DDR3L-1600 Registered DIMM with ECC Memory Clock 1600MHz Logical Standard Capacity Logical Maximum Capacity Memory protection 0GB Standard Capacity 0GB Maximum Logical Capacity Disk Controller 9.6 TB (8 x 1.2TB) RAID SAS : RAID 1 (Standard) Hot Plug Supported Optical Disk Drive DVD Super Multi drive Optical Drive Bays [free] Logical Disk Drive Bays [free] Standard 1 [0] Controller (VRAM) Integrated in Server Management Controller (32MB) Resolution / Color Supported 800 x 600 / 16.7M, 1024 x 768 / 16.7M, 1280 x 1024 / 65K 256GB (16 x 16 GB) ECC, x4 SDDC SAS: 6Gb/s (Standard) 1 8 [8] Total: 2 slots available 2 Low-profile PCIe x4 Gen 2 (x8 connector) Interfaces 1 VGA (15-pin mini D-sub, 1 rear per system) 4 USB2.0 (1 front, 3 rear per system) 4 1000BASE-T LAN connector (RJ-45, 2 rear per module) 2 Management LAN connector (RJ-45, 1 rear per module) Server Management EXPRESSSCOPE Engine 3 Power Supply 2 x 800 Watt (1 per module, 80 PLUS® Platinum certified) 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz NEC Corporation Revision 4.0, April 2015 3 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Model Power (Max. Config, Consumption Operating) Dimensions (W x D x H ) 1 R320d-E4 1,300 VA / 1,290 Watt 483.0 x 736.0 x 178 mm / 19.0 x 29.0 x 7.0 in (4U) Weight (Minimum / Maximum) 45 kg / 51 kg, 99.21 lbs. / 112.44 lbs. Temperature, Relative Humidity (non-condensing) Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% Regulatory and Safety FCC, CE, BSMI, CCC, UL, CB, RoHS Operating Systems Microsoft Windows Server® 2008 R2 Enterprise SP1 Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Writing software is not provided for this DVD drive. NEC Corporation Revision 4.0, April 2015 4 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model External Views Front and Rear Views Front View B A C D E F G H I J A N B K L M P Q R O S T U Legend A. Drive Bays L. CPU Fault LED B. UID Button M. Memory Fault LED C. DVD Super Multi Drive N. Module Power LED D. System Power LED O. SAFE TO PULL LED E. System Status LED P. PRIMARY LED F. System FT LED Q. IO Module Fault LED G. UID LED R. Fan Fault LED H. USB Connector S. PSU Fault LED I. Pull-out Tab T. DC Power Fault LED J. Power Button U. Temperature Fault LED K. Module ID LED NEC Corporation Revision 4.0, April 2015 5 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Rear View B C D D A F E F G H Legend 1 A. USB Connectors E. AC Inlet B. Management LAN Connector F. PCI Slots (Low-Profile) C. Module ID LED G. Serial Port Connector D. Data LAN Connectors H. VGA Connector 1 For service personnel only. NEC Corporation Revision 4.0, April 2015 6 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Dimensions (mm) Rack mount 748.5 736 177 448 485 688.5 Tower Conversion (Optional) 220 804 592 327 NEC Corporation Revision 4.0, April 2015 7 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Configuration Diagram Server CHASSIS REAR CHASSIS FRONT HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay Backplane CPU/IO Module HDD Bay Optical Drive Bay CPU/IO Module HDD Bay HDD Bay DIMM #8 DIMM #7 DIMM #6 DIMM #5 DIMM #9 DIMM #10 DIMM #11 DIMM #12 Cooling Fan #1 - #4 Processor CHASSIS FRONT HDD Bay #1 #2 #3 #4 Drive Cage HDD Bay DIMM DIMM DIMM DIMM HDD Bay CHASSIS REAR HDD Bay CPU/IO module #0 : Power Supply #16 #15 #14 #13 DIMM DIMM DIMM DIMM #1 #2 #3 #4 HDD Bay DIMM DIMM DIMM DIMM HDD Bay Processor PCIe 2.0 x4 (x8 socket) LP PCIe 2.0 x4 (x8 socket) LP HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay HDD Bay Drive Cage HDD Bay DIMM #8 DIMM #7 DIMM #6 DIMM #5 DIMM #9 DIMM #10 DIMM #11 DIMM #12 Cooling Fan #1 - #4 Processor HDD Bay CPU/IO module #1 : Processor PCIe 2.0 x4 (x8 socket) LP PCIe 2.0 x4 (x8 socket) LP Power Supply Legend: NEC Corporation DIMM DIMM DIMM DIMM #16 #15 #14 #13 Minimum required components Revision 4.0, April 2015 Standard components 8 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Server Configuration 1 Base Models Product Name / Description Part Number EXPRESS5800/R320d-E4 no RAM, no 2.5-inch HDD Including: Intel Xeon Processor E5-2620 v2, 1 x DVD Super Multi, EXPRESSBUILDER DVD N8800-184F 2 2nd Processor Available logical sockets: 1 Product Name / Description Part Number Intel® Xeon® Processor E5-2620 v2 2nd Processor Kit : 2.10 GHz / 6C-12T / 15 MB, 2 processors included N8801-046F 3 Memory Available logical slots: 8 per processor Product Name / Description Part Number 4GB DDR3-1600 REG Memory Kit : 2 x 1 x 4GB DIMM included N8802-060 32GB DDR3-1600 REG Memory Kit : 2 x 4 x 8GB DIMM included N8802-061 64GB DDR3-1600 REG Memory Kit : 2 x 4 x 16GB DIMM included N8802-062 NOTE: Minimum one memory kit must be installed. NEC Corporation Revision 4.0, April 2015 9 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Memory Configuration Guideline See the table below for the number of memory kits required in accordance with logical main memory size and number of logical processors. Memory configurations which are not listed below are not supported in the system. Number of Logical Processors 1 Logical Main Memory Size 4GB 2 1 4GB 32GB 64GB 1 - - 8GB 2 - - 12GB 3 - - 16GB 4 - - 20GB 5 - - 24GB 6 - - 28GB 7 - - 32GB 8 - - - 1 - 48GB 4 1 - 64GB - 2 - 64GB - - 1 96GB - 1 1 128GB - - 2 1 - - 2 - - 4GB 1 8GB 1 12GB 1 Number of Memory Kits Required 1 3 - - 16GB 4 - - 24GB 6 - - 32GB 8 - - 40GB 10 - - 48GB 12 - - 56GB 14 - - 64GB 16 - - - 2 - 96GB 8 2 - 128GB - 4 - - - 2 192GB - 2 2 256GB - - 4 Interleave is not supported. NEC Corporation Revision 4.0, April 2015 10 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model 4 Internal Hard Disk Drives Available bays: 8 Category Product Name / Description Part Number SAS HDD 600GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 600GB N8850-047 900GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 900GB N8850-048 1.2TB 10K Hot Plug 2.5-inch SAS HDD : 1 x 1.2TB N8850-051 146.5GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 146.5GB N8850-049 300GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 300GB N8850-050 200GB Hot Plug 2.5-inch SSD: 1 x 200GB N8850-052 SAS SSD NOTE: Hard drives must be installed in identical pairs to configure RAID 1. Required System Disk Capacity See the table below for minimum required system disk capacity to store whole memory dump data. It is recommended to install hard drives providing the minimum required system disk capacity to reduce the time to resynchronize after a hard drive replacement. (For Microsoft® Windows Server® 2008 R2 Enterprise SP1) Memory Size Up to 28GB 32GB to 48GB 56GB to 64GB 96GB to 192GB 256GB Required System Disk Capacity HDD SSD 146.5GB 300GB 200GB Not supported 600GB 900GB (For Microsoft® Windows Server® 2012 Standard / Datacenter) Memory Size Up to 24GB 28GB to 40GB 48GB to 64GB 96GB 128GB to 256GB Required System Disk Capacity HDD SSD 146.5GB 300GB 200GB Not supported 600GB 900GB Notes for BTO with SSD The smallest capacity HDD/SSD is installed in the 1st HDD bay (as system disk) at factory. If you use 200GB SSD as system disk and want to use 146.5GB HDD as data disk, order the 146.5GB HDD separately and install it later. When the operating system is Windows Server 2008 R2 and the memory size is 56GB or more, system disk capacity should be at least 300GB. In that case, BTO with SSD is not possible. If you want to use 200GB SSD as data disk in such a system, order the 200GB SSD separately and install it later. When the operating system is Windows Server 2012 and the memory size is 48GB or more, system disk capacity should be at least 300GB. In that case, BTO with SSD is not possible. If you want to use 200GB SSD as data disk in such a system, order the 200GB SSD separately and install it later. NEC Corporation Revision 4.0, April 2015 11 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model 5 Optical Drive Available bays: 1 Product Name / Description Part Number Internal DVD Super Multi Drive : 1 x DVD Super Multi drive, not including writing software (Standard) 6 PCI Card 6.1 LAN Controller Category Product Name / Description Part Number LAN Controller 1000BASE-T 2ch board kit : 2 x GbE NIC Intel® Gigabit ET Dual Port Server Adapter 10GBASE-T 1ch Adapter Kit : 2 x 10GbE NIC Intel® X540-T1 NOTE: - Up to one controller per module - FCoE functionality is not supported N8804-009 N8804-011 NOTE: For iSCSI (data) connection, only 1000BASE-T ports (Including standard LAN ports) are supported. 6.2 Fibre Channel / SAS Controller Category Product Name / Description Part Number Fibre Channel Controller Fibre Channel board kit (8Gbps) : 2 x FC Controller QLogic QLE2560 8Gbps Fibre Channel Adapters N8803-038 SAS Controller SAS Controller : 1 x SAS Controller LSI SAS9212-4i4e Host Bus Adapter NOTE: Up to one controller per module N8803-039 NOTE: For supported NEC Storage products to connect with N8803-038, contact your sales representative or refer to the NEC Storage WEB site. (http://www.nec.com/global/prod/storage/) 7 Other Add-in Components 7.1 Input Devices Category Product Name / Description Part Number Keyboard USB Keyboard N8870-002AF Mouse USB Optical Wheel Mouse N8870-012 Cable USB cable : 1.5m USB extension cable K410-177(1A) NEC Corporation Revision 4.0, April 2015 12 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model 8 Add-on Components 8.1 17-inch LCD Console Drawer Category Drawer w/ KVM Switch Drawer Cable Drawer w/o KVM Switch Drawer Keypad Product Name / Description Part Number 17inch LCD Console Unit (1U/8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height 17-inch LCD Console Drawer (8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height, black Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2m 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m, black 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m, black Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1port) Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-108F 17inch LCD Console Drawer (1port) N8143-77F N8143-106F K410-118(1A) K410-118(03) K410-118(05) N8143-76F N8143-105F N8143-84F N8143-108F N8143-85 N8143-87 N8143-109 N8143-111 8.2 KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch Server Switch Unit (8 server) 1U USB 8 port KVM switch, black Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A N8191-12F Cable NEC Corporation KVM Revision 4.0, April 2015 N8191-14F K410-118(1A) 13 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Cascading Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 K410-118(03) K410-118(05) K410-119(1A) 8.3 Flash FDD Order the Flash FDD if you need to prepare an alternative for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-96 8.4 Operating System Product Name / Description Part Number Microsoft Windows Server 2012 Standard (2CPU, 2VM) with Windows Server 2008 R2 downgrade rights, English For Windows Server 2008 R2 Enterprise installation UL1045-001E NOTE: Please note that this product can only be sold to users upon their requests. Access the following website and agree to the terms and conditions for this product before ordering. http://www.nec.com/en/global/prod/express/fault_tolerant/w2012/downFT.html For Microsoft® Windows Server® 2012 Standard / Datacenter, there is no special license for FT servers. Please arrange it locally, or contact your sales representative for the availability of this operating system from NEC in your region. 8.5 Active UpgradeTM Product Name / Description Part Number Active Upgrade for ft NOTE: Supported on Microsoft® Windows Server® 2008 R2 Enterprise SP1 only UL1535-001E 8.6 Tower Conversion Kit Product Name / Description Part Number Tower Conversion Kit 23 inch height pedestal with front bezel N8843-004 NEC Corporation Revision 4.0, April 2015 14 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model 8.7 External Tape Drives 8.7.1 Tape Drive Selection Refer to the section in accordance with your type of tape drives. LTO NEC Corporation LTO3 SAS Refer to 8.7.2 LTO4 SAS Refer to 8.7.2 LTO5 SAS Refer to 8.7.2 LTO6 SAS Refer to 8.7.2 Revision 4.0, April 2015 15 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model 8.7.2 LTO / SAS Category Product Name / Description Part Number Controller Required N8803-039 External Cable Required SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8, LP/FH NOTE: Up to one controller per module External SAS cable 2 m, for Tape Drive Enclosure connection Tape Enclosure Required 2U Tape Drive Enclosure 4 x 5-inch media bays, two internal SAS cables included, black N8141-75F Power Module Recommended Power Supply 1 x non-hot plug power supply unit for redundant configuration N8181-54F Internal Cable SAS Cable For 2U Tape Drive Enclosure internal connection NOTE: Required when three or more SAS connections (including other general purpose servers) to the N8141-75F K410-335(00) Drive 2 bays available Internal LTO (SAS) LTO3, Half height, Native capacity 400GB, black Internal LTO (SAS) LTO4, Half height, Native capacity 800GB, black Internal LTO (SAS) LTO5, Half height, Native capacity 1500GB, black Internal LTO (SAS) N8151-126 K410-191(02) N8151-127 N8151-128 N8151-129 LTO6, Half height, Native capacity 2.5 TB, black 8.7.3 Notes for Double Backup In a single backup configuration, in case a CPU/IO module or backup device fails, backup is not possible until the failed part is repaired or replaced. If this does not meet your system requirements, consider a double backup configuration. Refer to the following notes on double backup configuration. When configuring two sets of a SAS controller, a SAS cable and a backup device, two backup devices are recognized separately by the OS. When scheduling an automatic backup job, make a job for each backup device so that the other backup device can backup in case one device fails. With BrightStor ARCserve Backup, backup is not executed if you enter an asterisk (*) in the group box under the destination tab when defining a job. Be sure to create two backup jobs by correctly selecting the device group for the group box, and entering an asterisk (*) or the name of the media in the media box. NEC Corporation Revision 4.0, April 2015 16 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model 8.7.4 Supported Backup Software See the table below for the supported backup software on NEC EXPRESS5800/R320d. For Microsoft® Windows Server® 2008 R2 Enterprise SP1 Tape drive Backup software ARCserve Product Name / Description Part Number Backup Exec ARCserve r16.5 Backup Exec 2012 Backup Exec 2014 WS2008R2 WS2008R2 WS2008R2 Internal LTO (SAS) LTO3, Native capacity 400 GB N8151-102/126 *a1 *b1 *b1 Internal LTO (SAS) LTO4, Native capacity 800 GB N8151-90/127 *a1 *b1 *b1 N8151-103/128 *a1 *b1 *b1 N8151-106/129 *a1 *b1 *b1 Internal LTO (SAS) LTO5, Native capacity 1.5 TB Internal LTO (SAS) LTO6, Native capacity 2.5 TB *a1: Do not disable the tape driver on the device manager. *b1: Do not install the Symantec driver. Apply the driver which comes with the tape drive. NOTE: Disaster Recovery Option is not supported on the ft server system. It is not supported to backup from NEC Express5800/ft series to a backup device directly using NetBackup. However, NEC Express5800/ft series can be a backup-client machine of NetBackup. For Microsoft® Windows Server® 2012 Standard / Datacenter Tape drive Backup software ARCserve Product Name / Description Part Number Backup Exec ARCserve r16.5 Backup Exec 2012 Backup Exec 2014 WS2012 WS2012 WS2012 Internal LTO (SAS) LTO3, Native capacity 400 GB N8151-102/126 *a1 - *b1 Internal LTO (SAS) LTO4, Native capacity 800 GB N8151-90/127 *a1 - *b1 N8151-103/128 *a1 - *b1 N8151-106/129 *a1 - *b1 Internal LTO (SAS) LTO5, Native capacity 1.5 TB Internal LTO (SAS) LTO6, Native capacity 2.5 TB *a1: Do not disable the tape driver on the device manager. *b1: The BackupExec 2012 is not supported as media server on WS2012. NOTE: Disaster Recovery Option is not supported on the ft server system. It is not supported to backup from NEC Express5800/ft series to a backup device directly using NetBackup. However, NEC Express5800/ft series can be a backup-client machine of NetBackup. NEC Corporation Revision 4.0, April 2015 17 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Temperature/voltage/power/ fan /degeneration (memory/hard drive) Hardware event log collection Boot monitoring Booting, BIOS/POST stall, OS stall, shutdown Alerting HW error, Boot error and OS panic (by SNMP, E-Mail) Remote KVM POST/BIOS setup, DOS utility (via LAN) Panic screen, Boot screen Text-based screen (OS console) GUI-based screen (OS console) Remote control Remote reset/power on-off/ dump (via LAN) OS shutdown Remote media (CD/DVD/FD) Server Management Command Line Protocol (DMTF compliant) Remote control via Web browser (without dedicated app) Remote batch Scheduling (without UPS) Others Set automatic IP address via DNS/DHCP Remote wakeup Wake On LAN, Wake On Ring Centralized management Industry standard Monitoring and control of multiple servers IPMI 2.0 Hardware monitoring NEC Corporation Revision 4.0, April 2015 18 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Supported PCI Cards and Installable Slots Part Number Slots Slot # : #1 #2 PCI Slot: x4 x4 Card height: LP LP Slot type: x8 x8 N8804-009 1000BASE-T 2ch board kit N8804-011 10GBASE-T 1ch board set N8803-038 N8803-039 1 Product Name Fibre Channel board kit SAS board Notes Max. 1 1 1 1 1 Max. 1 Not installable when using Tower Conversion Kit. NEC Corporation Revision 4.0, April 2015 19 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Notes for using Hyper-V Brief system interruption during synchronization process In the synchronization process of CPU modules, a memory copy is performed to duplex memory on both CPU modules. Most of the memory area can be copied without interrupting the system through the so-called brownout copy method, and just a small portion requires the system to stop. However, with Hyper-V, the system cannot use the brownout copy method. Therefore, the system does not respond for a longer period of time during the synchronization process of the CPU modules than without Hyper-V. See the table below for the reference values of interruption during re-synchronization of CPU/IO modules in a Hyper-V system. It is recommended that your system design take the interruption into account. Model / Memory Size 8GB 16GB 64GB 128GB 256GB R320d-E4 2 sec 3 sec 10 sec 18 sec 36 sec R320d-M4 2 sec 3 sec 8 sec 14 sec 27 sec About Guest OS Guest operating systems supported on NEC Express5800/ft series are the same as other Express5800 Servers. The tables below show the supported guest OS. For Windows Server 2008 R2 Hyper-V OS Windows Server 2012 (x64) *1 Edition SP Standard / Datacenter RTM Windows Server 2008 R2 (x64) Standard / Enterprise RTM/SP1 Windows Server 2008 (x86/x64) Standard / Enterprise RTM/SP2 Windows Server 2003 R2 (x86/x64) Standard / Enterprise SP2 Windows Server 2003 (x86/x64) Standard / Enterprise SP2 Server / Advanced Server SP4 Pro RTM Windows 7 (x86/x64) Professional RTM/SP1 Windows Vista (x86/x64) Business SP1/SP2 Windows XP (x64) Professional SP2 Professional SP2/SP3 SUSE Linux Enterprise Server 10 (x86/x64) - SP3 Red Hat Enterprise Linux 5.2 - 5.5 (x86/x64) - - Windows 2000 *2 Windows 8 (x86/x64) Windows XP (x86) *1 *2 *3 *1: KB2744129 must be applied on the host OS. *2: Microsoft support has already ended since July 13, 2010. *3: Must be installed with the sp4-applied media NEC Corporation Revision 4.0, April 2015 20 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model For Windows Server 2012 Hyper-V OS Edition SP Windows Server 2012 R2 (x64) Standard / Datacenter RTM Windows Server 2012 (x64) Standard / Datacenter RTM Windows Server 2008 R2 (x64) Standard / Enterprise RTM/SP1 Windows Server 2008 (x86/x64) Standard / Enterprise SP2 Windows Server 2003 R2 (x86/x64) Standard / Enterprise SP2 Windows Server 2003 (x86/x64) Standard / Enterprise SP2 Windows 8 (x86/x64) Pro RTM Windows 7 (x86/x64) Professional RTM/SP1 Windows Vista (x86/x64) Business SP2 Windows XP (x64) Professional SP2 Windows XP (x86) Professional SP3 Backup When using Hyper-V on a FT server, prepare a separate server for backup in the same way as for other general purpose servers with Hyper-V. For backup patterns, refer to each backup software company's web site. NEC ESMPRO Agent For monitoring guest operating systems, NEC ESMPRO Agent for Guest OS is required. Contact your sales representative for this software. Active Upgrade (For Windows Server 2008 R2 only) A team assigned to the virtual network by Hyper-V Virtual Network Manager cannot be used in Active Upgrade. To use Active Upgrade, at least one team that is not assigned to virtual network is required. NEC Corporation Revision 4.0, April 2015 21 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 4.0, April 2015 22 CONFIGURATION GUIDE – NEC EXPRESS5800/R320d-E4 / Windows Server model Revision History Revision Date Description 4.0 2015.4.28 New products added: 17-inch LCD Console Drawer (8port) N8143-106F 17inch LCD Console Unit 1U N8143-105F 17inch LCD Console Drawer (1port) N8143-108F Keyboard Unit (JP) N8143-109 Keyboard Unit (UK) N8143-111 Server Switch Unit (8 server) N8191-14F Flash FDD N8160-96 2U Tape Drive Enclosure N8141-75F SAS cable K410-335(00) Internal LTO (SAS) N8151-126/ N8151-127/ N8151-128/ N8151-129 Discontinued products removed: Flash FDD N8160-86 2U Tape Drive Enclosure N8141-59F Internal SAS cable K410-249(00) Internal LTO (SAS) N8151-102/ N8151-90/ N8151-103/ N8151-106 3.0 2014.12.2 New products added: WS2012 Standard with WS2008R2 downgrade right UL1045-001E Discontinued products removed: WS2008R2 Enterprise English UL0999-436EN WS2008R2 Enterprise Chinese Traditional UL0999-436CT WS2008R2 Enterprise Chinese Simplified UL0999-436CS WS2008R2 Enterprise Korean UL0999-436KR Others: Required System Disk Capacity updated Supported Backup Software information updated 2.0 2014.6.16 New products added: 200GB Hot Plug 2.5-inch SSD N8850-052 Others: Windows Server 2012 supported 1.0 2014.3.18 Initial release NEC Corporation Revision 4.0, April 2015 23