C1005B C1005B-Series THERMAL CIRCUIT PROTECTORS The C1005B-Series offers the functionality of a switch and circuit breaker in a single compact package, which fits an industry standard .550 x 1.125 mounting hole. This combo device eliminates the need for both a switch and thermal circuit protector on customer panels. By using only this multipurpose product, wiring and assembly costs are greatly reduced, while at the same time, valuable panel real estate is saved. The C1005B-Series is available lighted or unlighted, in a variety of colors, with solder lug or .250 tabs. Current ratings range from 7-16 amps@125 and 250 VAC and up to 32 VDC. Product Highlights: .550 x 1.125 mounting hole (14mm x 28.6mm) Ratings from 7-16A Standard Reset/Off Legend Curved Rocker & Angular Bezel .250 Tabs or Solder Lug Terminations 65°C Max Operating Temperature 1000 AIC Interrupting Capacity 1500 VAC Dielectric Strength 100M ohms @500VDC Insulation Resistance Compact Space-Saving Envelope UL1077, UL1363, IEC 60934 Typical Applications: Household Appliances Commercial Appliances Transportation Marine Telecommunications Power Strips Audio-visual Equipment Medical equipment Power supplies Generators Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: [email protected] Application Support: [email protected] Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com 2 | C1005B-Series - Ordering Scheme, Time Delay, Dimensional Specifications C1005B 3 B 15 1 B R 3 1 Series 2 3 4 Illumination Termination Current Rating 5 Contact Material 6 Bezel Legend 7 Rocker Color 8 Lamp Voltage 1 SERIES C1005B 5 CONTACT MATERIAL 1 1 Silver Cad Oxide (switch), Silver plated copper (breaker) 2 ILLUMINATION 2 Non-Lighted 3 Lighted 6 BEZEL LEGEND IMPRINT B Black Bezel with white legend W White Bezel with black legend C Gray Bezel with black legend 3 TERMINATION A Solder Lug B .250 Tab 4 CURRENT RATING (AMPERES) 07 7 amps 08 8 amps 09 9 amps 10 10 amps 11 11 amps 12 13 14 15 16 7 ROCKER COLOR R Red G Green U Blue T Clear Note: RESET OFF Legend is standard. 12 amps 13 amps 14 amps 15 amps 16 amps 8 LAMP VOLTAGE 3 Neon Lamp 125/250 VAC 9 Non-lighted Notes: 1. Silver cad oxide switch and breaker contacts are available as a special order. Specify 3 for selection 5 Dimensional Specifications: in. [mm] 1.280 [32.5] 1.125 [28.6] .669 [17] .858 [21.8] PANEL CUT OUT .550 [14] .07 [1.79] .921 [23.4] .236 [6] .472 [12] .0315 [.8] .394 [10] .394 [10] .248 [6.17] 1.102 [28] .532 [13.5] Time Delay Percentage of Rated Current Overload Trip Time 100% No Trip 150% Trip in 1 hr 200% 4.0 ~ 40 sec. 300% 0.9 ~ 8.0 sec. 400% 0.42 ~ 5.0 sec. 500% 0.25 ~ 3.0 sec. 600% 0.01 ~ 1.8 sec. Trip Time in Seconds Time Trip Factor 1 -10 °C x 1.70 -5 °C x 1.60 0 °C x 1.50 5 °C x 1.40 10 °C x 1.30 15 °C x 1.20 20 °C x 1.10 25 °C x 1.00 Time Trip Factor 1 30 °C x 0.90 35 °C x 0.85 40 °C x 0.80 45 °C x 0.75 50 °C x 0.70 55 °C x 0.65 60 °C x 0.60 *Manufacturer reserves the right to change product specification without prior notice. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Notes: 1. Trip Time factor is a guideline that indicates ambient temperature effect on trip times at various overload values. Reps & Contact | 3 Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest Alaska, Hawaii « NORTHERN Hanna Lind Ltd. Melody Emery Sierra Bridge Marketing Omega Limited Dy-tronix Inc. LD. Allen Norris DM Assoc East Pacent DM Assoc TSI North TSI WEST Signal Enterprises Luscombe Engineering Pinnacle Marketing Sunbelt Components « South America DM Mexico Mexico SOUTHEAST ProRep Solutions « Matrix LATIN AMERICA Americas Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: [email protected] Northern Region Sales Office: [email protected] Southeast Region Sales Office: [email protected] Midwest Region Sales Office: [email protected] West Region Sales Office: [email protected] Latin America Sales Office: [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China: [email protected] Shanghai, China: [email protected] Pune, India: [email protected] Kaohsiung, Taiwan: [email protected] Yokohama, Japan: [email protected] Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: [email protected] Germany: [email protected] France: [email protected] www.carlingtech.com REV_06_2016