Click Here to download this file: http://www.murata-ps.com/data/power/cps/cdc_ehs20-012.pdf

E Class Converters
EHS20 – 1.2V Model
OBSOLETE PRODUCT
Model
Parameter
1.2V
Output Voltage Setpoint
Units
1.18 – 1.22
Vdc
0.1% / 0.2%
% Vo
Output total regulation
1.16 – 1.24
Vdc
Output adjust (note 4)
90-110
%Vo,nom
Line/Load Regulation
Max
Remote-sense Comp.
Output Ripple & Noise (note 2)
10%
Max
Output Current
Efficiency (48V, Full load, 25C)
Typ
External Capacitance
Transient Response (typ) (note 3)
25% step, 1A/μs
V
mVp-p
0-20
A
85%
%
1,000-10,000
μF
ΔVo
150
mV
Ts
400
μs
1.5 – 1.8
V
25
A
Over-voltage trip point (latching)
Over-current trip point (non-latching)
100
Typ
All specifications, waveforms, charts at Ta=25C, Vin=48V, unless otherwise specified
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
1
EHS20-012-6200991518
E Class Converters
Murata Power Solutions
EHS20 – 1.2V Model
Parameter
Input
Conditions
Input Voltage (Vin)
Reflected Ripple Current
Inrush Transient
Input Voltage Transient
Undervoltage Lockout
Isolation
Temperature
Protection
Over-voltage lockout
Input-Output
Resistance; input-output
Operating Ambient
Storage
Over-Temperature
Physical Information Dimensions
MTBF
Safety
Min.
Typ.
Max.
Units
36
48
25
75
0.2
Vdc
‘mA p-p
A2s
100
V
35
34
81
Vdc
Vdc
Vdc
Vdc
Mohm
°C
°C
See note (1)
100mS 10% duty
cycle
Turn-on
(non-latching)Turn-off
(non-latching)Turn-off
(non-latching)Measured on PCB
32
31
77
1500
10
-40
-40
90
125
130
°C
2.30”L x 0.82” W x 0.37”H (58.4 x 20.8 x 9.3 mm)
Calculated at 40C ambient, (Bellcore)
1,000,000 Hrs
EHS15/20 Series
Demonstrated at 40C ambient with 90% confidence: 2,800,000 Hrs
Complies with IEC/EN/CSA/UL 60950, provides basic insulation, input to output.
c-UL-us (US and Canada) recognized, TUV certified (Bauart).
www.murata-ps.com/support
2
EHS20-012-6200991518
E Class Converters
Murata Power Solutions
EHS20 – 1.2V Model
EHS20-012 Thermal Derating
EHS20-012 Thermal Derating
Airflow from Vin to Vo, Tj = 120ºC
Airflow from Vo(-) to Vo(+), Tj= 120ºC
25
25
20
Output Current [A]
Output Current [A]
20
15
10
400 LFM
300 LFM
200 LFM
100 LFM
15
10
5
25
35
45
55
65
75
400 LFM
300 LFM
200 LFM
100 LFM
5
85
25
Ambient Temperature [ºC]
35
45
55
65
Ambient Temperature [ºC]
75
85
EHS20-012 Enable with Pre-Bias
EHS20-012 Efficiency
95
90
85
Efficiency [%]
80
75
70
65
Vin=36V
Vin=48V
Vin=75V
60
55
Output Voltage @ 0.2 V/div., 2 ms/div.
Prebias voltage =0.6 Vdc. Input Voltage 48 V
Load = 0 A, Load capacitance = 10000 uF.
50
45
40
4
6
8
10
12
14
16
18
20
22
24
Iout [Adc]
5.10 Vnom ( 100
Rup
%)
0.6 %
Where
%
( Vout
: 1.2V model
510
Rup (1.2 V)
10.2
K
%
Vnom) 100
1000
and, Vout = Target output voltage
Vnom
Rdown ( % )
510
Where
10.2 K
%
%
Resistance (Kohms
Trim Up/Down Formula
EHS20-012 Trim-up and Trim-down Resistance
Rdown (1.2 V)
100
( Vnom Vout ) 100
Vnom
10
0%
2%
4%
6%
Delta (%)
8%
10%
www.murata-ps.com/support
3
EHS20-012-6200991518
E Class Converters
Murata Power Solutions
EHS20 – 1.2V Model
EHS20- 012 Startup Sequence from Enable
EHS20- 012 Startup Sequence from Vin
Top Trace: Vout @ 0.5 V/div.
Bot. Trace: Vin @ 50V/div.
Horiz. @ 50 ms/div.
Load: 20 A. Turn-on delay: 110mS
Top Trace: Vout @ 0.5 V/div.
Bot. Trace: Venable @ 2 V/div.
Horiz. @ 5 ms/div.
Load: 20 A, 10000 uF
Turn-on delay: 4.38 ms
EHS20-012 Transient Response 50-75% step ,1A/μs
EHS20-012 Transient Response 50- 25% step, 1A/μs
CH1: Vout AC coupled
CH2 : Step up Current (2A/div)
CH1: Vout AC coupled
CH2 : Step down Current (2A/div)
EHS20- 012 Input Reflected Ripple Current
EHS20-012 Output Ripple Voltage, Io=20A
Input Current @ 5 mA/div., 20 us/div. (9.2 mApp)
Input Voltage: 48 V, Load Current: 20 A
Note: see test circuit on following page.
www.murata-ps.com/support
4
EHS20-012-6200991518
E Class Converters
Murata Power Solutions
EHS20 – 1.2V Model
Notes:
1.
Input Reflected Ripple is specified when measured with the filter shown below
is
ic
L2
Vin
1 2u F
2 2 0 uF ,
E S R < 0.1 O h m s
@ 1 00 k H z
33uF,
E S R < 0 .7 O hm s
@ 1 0 0 kH z
DC-DC
Converter
RTN
2.
Output Ripple and noise is specified when measured with a 10uF tantalum and a 1uF ceramic
capacitor at the converter output pins
3.
Transient response is specified with a 470uF tantalum capacitor at the output of the converter
4.
Trim resistor connection: Rtrim-up connected from Vo adj to Vo(+), Rtrim –down connected from
Vo adj to Vo(-).
EHS20-012 Enable Pin Connection Table
NEGATIVE LOGIC VERSION
POSITIVE LOGIC VERSION
Note:
ENABLE POWER SUPPLY
0V < Venable < 0.8V
(internal pull-up > 50Kohms @
5V)
2.5V < Venable < 15V
(external pull-up > 1Kohms)
DISABLE POWER SUPPLY
2.5V < Venable < 15V
(external pull-up > 1Kohms)
0V < Venable < 0.8V
(internal pull-up > 50Kohms @
5V)
Power Supply has internal pull-up resistor. Enable pin is in a valid “high” state if left open-circuit.
Safety considerations
The EHS series of converters are certified to IEC/EN/CSA/UL 60950. If this product is built into information technology
equipment, the installation must comply with the above standard.
An external input fuse (5A to 30A recommended), must be used to meet the above requirements.
The output of the converter [Vo(+)/Vo(-)] is considered to remain within SELV limits when the input to the converter
meets SELV or TNV-2 requirements.
The converters and materials meet UL 94V-0 flammability ratings.
www.murata-ps.com/support
5
EHS20-012-6200991518
E Class Converters
Murata Power Solutions
EHS20 – 1.2V Model
Part Number Designations
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
6
EHS20-012-6200991518