Click Here to download this file: http://www.murata-ps.com/data/power/cps/cdc_qhs55-012.pdf

Q-ClassConverters
QHS55-012 Model
OBSOLETE PRODUCT
Model
Parameter
1.2V
Output Voltage Setpoint
Line/Load Regulation
Max
Output total regulation
Output adjust
Remote-sense Comp.
Units
1.18 – 1.22
Vdc
0.1%, 0.2%
% Vo
1.16 – 1.24
Vdc
90-110
%Vo,nom
10%
V
Max
100
Min
0.1
A
Max
55
A
Efficiency (48V, Full load, 25C)
Typ
86.5%
%
External Capacitance
Max
40,000
μF
ΔVo
150
μs
Output Ripple & Noise (note 2)
Output Current
Transient Response (typ) (note3)
mVp-p
mV
25% step, 1A/μs
Over-voltage trip point -static
-dynamic
Ts
300
max
1.45 – 1.65
1.8
V
Over-current trip point
Typ
66
A
All specifications at Ta=25C, Vin=48V, 300 LFM unless otherwise specified
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
Technical enquiries email: [email protected], tel: +508 339 3000
1
QHS55-012_6201051522_C01_22/04/08
Q-ClassConverters
Murata Power Solutions
QHS55-012 Model
Parameter
Input
Isolation
Temperature
Protection
Conditions
Input Voltage (Vin)
Reflected Ripple Current (see note 1)
Input Current
Inrush Transient
Input Voltage Transient 100mS 10% duty cycle
Undervoltage Lockout
Turn-on
Turn-off
Over-voltage lockout
Turn-off
Turn-on
Input-Output
Resistance; input-output
Operating Ambient
Storage
Over-Temperature
Safety
Typ.
Max.
Units
36
--
48
--
32
31
76
75
1500
10
-40
-40
75
10
3
0.2
100
35
34
80
79
---
85
125
Vdc
mA p-p
A
A2s
V
Vdc
Vdc
Vdc
Vdc
Vdc
Mohm
°C
°C
--
120
--
Deg C
Measured on PCB
Physical Information Dimensions
MTBF(Bellcore)
Min.
2.28”L x 1.45” W x 0.47”H (57.91 x 36.83 x 11.8 mm)
Calculated at 40C ambient, 100% Iomax:
1,000,000 Hrs
The QHS55-012 Complies with IEC/EN/CSA/UL 60950, provides basic insulation, input to
output. c-UL-us (US and Canada) recognized. TUV (Bauart) approved.
QHS55-012 Thermal Derating TJ = 120ºC
Airflow Parallel To Vin to Vout
60
55
50
Output Current [A]
45
40
35
30
25
100 LFM
200 LFM
20
300 LFM
400 LFM
15
Poly. (100 LFM)
10
5
0
25
35
45
55
65
75
85
Ambient Temperature [ºC]
www.murata-ps.com/support
2
QHS55-012_6201051522_C01_22/04/08
Q-ClassConverters
Murata Power Solutions
QHS55-012 Model
x
Pin Assignments
Pin #
1
2
3
Description
Vin (+)
Enable
Vin(-)
Pin #
4
5
6
Description
Vout(-)
Sense Vo adj
Pin #
7
8
Description
Sense +
Vo (+)
Notes:
1. Input Reflected Ripple is specified when measured with the filter shown below.
is
ic
L2
Vin
12uF
220uF,
ESR<0.1 Ohms
@ 100kHz
33uF,
ESR<0.7 Ohms
@ 100kHz
DC-DC
Converter
RTN
2. Output Ripple and noise is specified when measured with a 10uF tantalum and a 1uF ceramic
capacitor at the converter output pins.
3. Transient response is specified without a capacitor at the output of the converter.
4. The Enable signal is Logic Low. It is referenced to Vi-. The pin should be tied to Vi- if it is not
used. Isink = 0.1mA max, Voff = 15V max.
www.murata-ps.com/support
3
QHS55-012_6201051522_C01_22/04/08
Murata Power Solutions
Q-ClassConverters
QHS55-012 Model
EFFICIENCY
Output Ripple and Noise
Io=55A BW 100MHz
Vin:75V
Vin:48V
Vin:36V
Output Voltage Response to Step Load
(30A, -15A load step, di/dt = 1A/us, Tamb=25C,
Output Voltage Response to Step Load
(30A, +15A load step, di/dt = 1A/us, Tamb=25C,Vin=48V)
www.murata-ps.com/support
4
QHS55-012_6201051522_C01_22/04/08
Q-ClassConverters
Murata Power Solutions
QHS55-012 Model
Input Reflected Ripple :
Vin=48V, Iout=55A, 25C
Scale: 0.5mA/mV
Startup Characteristics
Vin = 48V Iout = 55A Local O/P Sensing
Vin = 48V Iout = 0A Local O/P Sensing
Vout
Enable
Turn-Off Characteristic
Pre-Bias Startup Characteristic
Vin = 48V Iout=0A, Cout=5000uF Pre-bias of 0.8V
Vin = 48V Iout = 55A
Vout
Enable
www.murata-ps.com/support
5
QHS55-012_6201051522_C01_22/04/08
Q-ClassConverters
Murata Power Solutions
QHS55-012 Model
Conducted EMI Characteristic with
external filter as specified
VREF 0.6125
Vout
1.2
QHS55-012 Trim-up Resistance (kOhm)
1000
5.11 Vout
( 100
%)
VREF %
Rdown
511
511
10.22
Resistance (kOhm)
Rup
%
10.22
%
100
10
0
2
4 Delta % 6
8
10
Safety considerations
The QHS series of converters comply with IEC/EN/CSA/UL 60950, providing basic insulation, input to output and is
c-UL-us (US & Canada) certified. TUV approved. If this product is built into information technology equipment, the
installation must comply with the above standard. An external input fuse (5A to 30A recommended) must be used to
meet the above requirements. The output of the converter [Vo(+)/Vo(-)] is considered to remain within SELV limits when
the input to the converter meets SELV or TNV-2 requirements.
www.murata-ps.com/support
6
QHS55-012_6201051522_C01_22/04/08
Murata Power Solutions
Q-ClassConverters
QHS55-012 Model
Part Number Designations
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
7
QHS55-012_6201051522_C01_22/04/08